Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 11
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 1398-1402 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Axial energy spread and useful beam current of positive ion beams have been carried out using a radio frequency (rf)-driven multicusp ion source. Operating the source with a 13.56 MHz induction discharge, the axial energy spread is found to be approximately 3.2 eV. The extractable beam current of the rf-driven source is found to be comparable to that of filament-discharge sources. With a 0.6 mm diameter extraction aperture, a positive hydrogen ion beam current density of 80 mA/cm2 can be obtained at a rf input power of 2.5 kW. The expected source lifetime is much longer than that of filament discharges. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1657-1661 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We have developed a new magnetic monocusp ion source for single aperture applications such as neutron generators. Coupling solenoidal magnetic fields on both sides of a monocusp magnetic field has generated over 70% atomic deuterium ions at pressures as low as 0.4 Pa (3 mTorr). This article describes the performance and characteristics of the solenoidal and monocusp ion source. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1384-1386 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: High charge state ion beams are commonly used in atomic and nuclear physics experiments. Multiply charged ions are normally produced in an ECR or in an EBIS. Multicusp generators can confine primary electrons very efficiently. Therefore, the electrical and gas efficiencies of these devices are high. Since the magnetic cusp fields are localized near the chamber wall, large volumes of uniform and high density plasmas can be obtained at low pressure, conditions favorable for the formation of multiply charged state ions. Attempts have been made at LBNL to generate multiply charged ion beams by employing a 25-cm diam by 25-cm long multicusp source. Experimental results demonstrated that charge states as high as 7+ can be obtained with argon or xenon plasmas. Multiply charged metallic ions such as tungsten and titanium have also been successfully formed in the multicusp source by evaporation and sputtering processes. In order to extend the charge state to higher values, a novel technique of injecting high energy electrons into the source plasma is proposed. If this is successful, the multicusp source will become very useful for radioactive beam accelerators, ion implantation, and nuclear physics applications. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Radio-frequency (rf)-driven multicusp ion sources have been developed extensively at Lawrence Berkeley National Laboratory (LBNL) for many applications, each requiring specific source designs. These uses have ranged from large ion sources for neutral-beam injectors—several tens of centimeters in size—to small sources for oil-well logging neutron tubes—a few centimeters in diameter. The advantages associated with internal antenna, rf-driven ion sources include reliability, long component life, ease of operation, and the ability to generate plasmas free of the impurities commonly found in hot-filament discharge sources. We have investigated and characterized the performance of rf-driven sources with respect to the rf operating frequency and ion source size for hydrogen ion species and current density. Furthermore, we have included in this study the aspects of proper coupling of the rf generator to the antenna through an impedance matching network. Finally, critical issues pertaining to general rf operation including beam extraction, rf shielding, and cooling of transformer cores are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1249-1251 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source is planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 μm patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of a rf-generated plasma. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 64 (1993), S. 2729-2736 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Tokamak Fusion Test Reactor (TFTR) deuterium neutral beams have been operated unintentionally with significant quantities of extracted water ions. Water has been observed with an optical multichannel analyzer. These leaks were thermally induced with the contamination level increasing linearly with pulse length. Up to 6% of the beam current was attributed to water ions, corresponding to an instantaneous value of 12% at the end of a 1.5 s pulse. A similar contamination is observed during initial operation of ion sources exposed to air. Operation of new ion sources typically produces a contamination level of ∼2%, with cleanup to undetectable levels in 50–100 beam pulses. Approximately 90% of the water extracted from ion sources with water leaks was deuterated, implying that there is the potential for tritiated water production during TFTR's forthcoming DT operation. It is concluded that isotope exchange in the plasma generator takes place rapidly, most likely as the result of surface catalysis. The primary concern is with O implanted into beam absorbers recombining with tritium, and the subsequent retention of T2O on cryopanels.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 3701-3709 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A technique is described whereby the ion dumps inside the TFTR Neutral Beam Test Stand were used to measure thermal profiles of the full-, half-, and third-energy ions. 136 thermocouples were installed on the full-energy ion dump, allowing full beam contours. Additional linear arrays across the widths of the half- and third-energy ion dumps provided a measure of the shape, in the direction parallel to the grid rails, of the half- and third-energy ions, and, hence, of the molecular ions extracted from the source. As a result of these measurements, it was found that the magnet was more weakly focusing, by a factor of 2, than expected, explaining past overheating of the full-energy ion dump. Hollow profiles on the half- and third-energy ion dumps were observed, suggesting that extraction of D+2 and D+3 is primarily from the edge of the ion source. If extraction of half-energy ions is from the edge of the accelerator, a divergence parallel to the grid rails of 0.6°±0.1° is deduced. It is postulated that a nonuniform gas profile near the accelerator is the cause of the hollow partial-energy ion profiles, the pressure being depressed over the accelerator by particles passing through this highly transparent structure. Primary electrons reaching the accelerator produce nonuniform densities of D+2 through the ionization of this gas. D+3 is created through subsequent D+2-gas collisions. A technique of rastering the ion beam across the full-energy dump was examined as a means of reducing the power density. By unbalancing the currents in the two coils of the magnet, on a shot-by-shot basis, by up to a 2:1 ratio, it was possible to move the centerline of the full-energy ion beam sideways by ∼12.5 cm. The adoption of such a technique, with a ramp of the coil imbalance from 2:1 to 1:2 over a beam pulse, could reduce the full-energy ion dump power density by a factor of (approximately-greater-than)1.5.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 877-879 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Multicusp ion sources are capable of producing positive and negative ions with good beam quality and low energy spread. The ion energy spread of multicusp sources has been measured by three different techniques. The axial ion energy spread has been reduced by introducing a magnetic filter inside the multicusp source chamber which adjusts the plasma potential distribution. The axial energy spread is further reduced by optimizing the source configuration. Values as low as 0.8 eV have been achieved. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 989-991 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The upgrade of the Los Alamos Neutron Science Center (LANSCE) will require an ion source producing high intensity H− beams. The new LANSCE source in particular will need to generate 40 mA of H− beam current at a duty factor of 12% (1 ms pulse at 120 Hz). To achieve this, the present Los Alamos results were first reproduced employing a prototype surface conversion source similar to the existing LANSCE source. Using these results as a benchmark for further testing, it was discovered that by moving the filament cathode into the chamber's cusp-field, the H− ion yield was enhanced. Considering this result, two extension chambers were added with movable magnetic filters at each end of the source to further improve the H− beam current. In addition, construction has been started on a new prototype axial source which will enable more plasma ions to funnel across the filter field into the central region where the converter is located. Results of the magnetic filter operation as well as the new axial source design will be presented. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of organic chemistry 37 (1972), S. 3383-3384 
    ISSN: 1520-6904
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...