Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 33 (2000), S. 851-854 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: In 1998, the combined Interferometer and Ultra Small Angle Neutron Scattering (USANS) instrument S18 at the 58 MW High Flux Reactor at the Institute Laue-Langevin in Grenoble (France) started operation. The instrument has been upgraded to allow more advanced neutron optics experiments for fundamental, nuclear and condensed matter physics. The new supermirror guide along with the two channel cut silicon perfect crystals, configured as an advanced high resolution Bonse-Hart camera, provides optimal intensity conditions. A large range of wavelengths is accessible by variations of the Bragg angle and by using different reflecting planes of a properly cut silicon monochromator block in combination with different channel-cut analyzer crystals. The fine adjustment analyzer system is achieved by an advanced piezo drive, which has an accuracy of 0.036 seconds of arc. The basic features of the USANS camera, which takes advantage of a new tail suppression method, and the results of various test measurements concerning intensities, long term stability and the accessible wavelength range will be presented. A high resolution position sensitive detector can either be used to analyze beam profiles or to perform neutron radiography experiments.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0898-6568
    Keywords: DNA synthesis ; K-ATPase activity ; Na ; Potassium ; arginine-vasopressin ; cell culture ; epithelial growth factor ; neuroglia ; protein synthesis
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    International Journal of Biochemistry 7 (1976), S. 287-292 
    ISSN: 0020-711X
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Journal of Chromatography B: Biomedical Sciences and Applications 230 (1982), S. 15-28 
    ISSN: 0378-4347
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Tetrahedron Letters 18 (1977), S. 1265-1268 
    ISSN: 0040-4039
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0090-6980
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Prostaglandins 21 (1981), S. 691-698 
    ISSN: 0090-6980
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1433-2965
    Keywords: Key words:Bone mineral density – Differential diagnosis – Fractures – Osteoarthritis – Osteoporosis – Vertebral deformity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract: Morphometric methods have been developed for standardized assessment of vertebral deformities in clinical and epidemiologic studies of spinal osteoporosis. However, vertebral deformity may be caused by a variety of other conditions. To examine the validity of morphometrically assessed vertebral deformities as an index of osteoporotic vertebral fractures, we developed an algorithm for radiological differential classification (RDC) based on a combination of quantitative and qualitative assessment of lateral spinal radiographs. Radiographs were obtained in a population of 50- to 80-year-old German women (n= 283) and men (n = 297) surveyed in the context of the European Vertebral Osteoporosis Study (EVOS). Morphometric methods (Eastell 3 SD and 4 SD criteria, McCloskey) were validated against RDC and against bone mineral density (BMD) at the femur and the lumbar spine. According to RDC 36 persons (6.2%) had at least one osteoporotic vertebral fracture; among 516 (88.9%) nonosteoporotics 154 had severe spondylosis, 132 had other spinal disease and 219 had normal findings; 14 persons (2.4%) could not be unequivocally classified. The prevalence of morphometrically assessed vertebral deformities ranged from 7.3% to 19.2% in women and from 3.5% to 16.6% in men, depending on the stringency of the morphometric criteria. The agreement between RDC and morphometric methods was poor. In men, 62–86% of cases with vertebral deformities were classified as nonosteoporotic (severe spondylosis or other spinal disease) by RDC, compared with 31–68% in women. Among these, most had wedge deformities of the thoracic spine. On the other hand, up to 80% of osteoporotic vertebral fractures in men and up to 48% in women were missed by morphometry, in particular endplate fractures at the lumbar spine. In the group with osteoporotic vertebral fractures by RDC the proportion of persons with osteoporosis according to the WHO criteria (T-score 〈−2.5 SD) was 90.0% in women and 86.6% in men, compared with 67.9–85.0% in women and 20.8–50.0% in men with vertebral deformities by various methods. Although vertebral deformities by most definitions were significantly and inversely related to BMD as a continuous variable in both sexes [OR; 95% CI ranged between (1.70; 1.07–2.70) and (3.69; 1.33–10.25)], a much stronger association existed between BMD and osteoporotic fractures defined by RDC [OR; 95% CI between (4.85; 2.30–10.24) and (15.40; 4.65–51.02)]. In the nonosteoporotic group individuals with severe spondylosis had significantly higher BMD values at the femoral neck (p 〈0.01) and lumbar spine (p 〈0.0004) compared with the normal group. On the basis of internal (RDC) and external (BMD) validation, we conclude that assessment of vertebral osteoporotic fracture by quantitative methods alone will result in considerable misclassification, especially in men. Criteria for differential diagnosis as used within RDC can be helpful for a standardized subclassification of vertebral deformities in studies of spinal osteoporosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1433-2965
    Keywords: Deformity Index ; Fracture assessment ; Osteoporosis ; Osteoporosis progression ; Spine ; Vertebra
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract There is no agreed definition for the assessment of vertebral fractures and deformities in patients with osteoporosis. Radiographs of 66 patients randomized for therapy with etidronate or placebo were analyzed at baseline and during follow-up (60/120/150 weeks) independently using two procedures. The first method of spinal deformity index (SDIG) and vertebral deformity score (VDSG) is based on a semiquantitative visual reading of each vertebra between T4 and L4. The second method of spine deformity index (SDIM) and vertebral deformity index (VDIM) is based on vertebral height measurements of T4 through L5 and each measurement from T5 to L5 (anterior, middle and posterior height) is related to T4 and compared with the respective T4-related normal range. There was good agreement between the mean vertebral deformation from T5 to L4 graded by VDSG and VDIM, with correlation coefficients betweenR=0.52 (p〈0.0001) andR=0.9 (p〈0.0001) respectively. Spinal deformation at baseline as measured by SDIM and SDIG was correlated withR=0.76 (p〈0.0001). For diagnosing a vertebra as fractured or not, VDIM reached a sensitivity of 82% and a specificity of 85% using VDSG as a standard, and on the other hand VDSG reached a sensitivity of 78% and a specificity of 88% in relation to VDIM. The changes in spinal deformation from week 0 to 150 were correlated withR=0.58 (p〈0.0002) between SDIM and SDIG. To detect vertebral fracture progression the sensitivity of VDIM was 74% and the specificity 86%, when changes in VDSG were used as a standard. On the other hand sensitivity for VDSG was 56% and specificity 95% to detect vertebral fracture progression, when changes in VDIM were used as a standard. The comparison of changes in spinal deformation in the etidronate and placebo group during the 3-year study demonstrated that changes in SDIM during follow-up confirmed the results found by the changes in SDIG. As an independent standard for vertebral deformity and fracture definition is not available, the present study does not allow a decision as to whether semiquantitative reading (SDIG) or vertebral height measurements (SDIM) are closer to the biological truth. We conclude that in clinical studies the assessment of vertebral fractures or deformations should be validated by the comparison between two different established techniques, performed independently.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1433-2965
    Keywords: Key words:: Osteoporosis – Pulmonary function, Quality of life – Vertebral fractures
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract: Vertebral deformation in spinal osteoporosis results in spinal and thoracic deformation, causing pain, disability and an overall decrease in quality of life. We sought to determine whether thoracic spinal deformation may lead to impaired pulmonary function. We studied expiratory relaxed vital capacity (VC) and forced expiratory volume in 1 s (FEV1) in 34 patients with spinal osteoporotic fractures and 51 patients with chronic low back pain (CLBP) due to reasons other than osteoporosis. Measurements of pulmonary function tests were calculated as a percentage of the normal range adjusting for age, sex, and height using the equations for normal values of the EKGS (Europäische Gesellschaft für Kohle und Stahl). Severity of osteoporosis was determined by calculation of the spine deformity index (SDI-total and SDI-anterior) on lateral radiographs of the spine and clinical measures of body stature (height reduction, distance from lowest ribs to iliac crest and distance from the occiput to the wall). Patients with osteoporosis had a lower vital capacity (%VC of the reference value) than patients with CLBP. The differences were more prominent (p〈0.05) when the previous body height, at age 25 years, was used as reference for calculation of VC (mean ± SD: 93.6%± 15.3% in patients with osteoporosis v 105.6%± 15.1% in patients with CLBP). FEV1 was significantly (p〈0.05) lower in patients with osteoporosis when previous body height was considered, in comparison with patients with CLBP (mean ± SD: 85.0%± 14.2% in patients with osteoporosis v 92.4%± 13.6% in patients with CLBP). In patients with osteoporosis VC (standardized on previous body height) was significantly negatively correlated with SDI-anterior (r=–0.4, p〈0.03). Furthermore, VC standardized on previous body height showed a weak but significant negative correlation with some clinical measures of osteoporosis (height reduction vs %VC: r=–0.34, p〈0.05; distance from the lowest ribs to iliac crest vs %VC: r= 0.35, p〈0.04). In conclusion, we found that pulmonary function is significantly diminished in patients with spinal osteoporotic fractures as compared with CLBP patients without evidence of manifest osteoporosis. Reduction of pulmonary function is correlated significantly with clinical and radiological measures of severity of spinal deformation due to osteoporotic fractures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...