Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 210 (1966), S. 37-37 
    ISSN: 1435-1536
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Zusammenfassung In vielen Arbeiten über die Relaxationsspektroskopie von Hochpolymeren wird lediglich die Temperatur und nicht die Frequenz in großen Bereichen variiert. Dies reicht bei systematischer Änderung der chemischen Struktur vielfach bereits aus, um bestimmte Dispersionsgebiete den Bewegungen bestimmter Atomgruppen zuzuordnen. Weitergehende Aussagen über den Mechanismus der Umlagerungsprozesse, insbesondere über die Wechselwirkung zwischen verschiedenen Platzwechselprozessen und über kooperative Effekte erhält man jedoch nur dann, wenn die Messungen über größere Frequenzbereiche ausgedehnt und die Änderungen des Relaxationszeitenspektrums als Funktion von Temperatur und Druck untersucht werden. Möglichkeiten und Grenzen dieses Verfahrens werden diskutiert.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Archives of orthopaedic and trauma surgery 66 (1969), S. 347-354 
    ISSN: 1434-3916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Par le traitement conservateur (par médicaments ou bien physiothérapeutique) des irritations de la circulation artérielle on obtient un soulagement subjectif. Il résulte du fait que le courant sanguin est économisé par un changement de la hémodynamique et du métabolisme des muscles. Ce changement ne constiste pas toujours dans une augmentation du courant sanguin musculaire, au contraire parfois le courant fut nettement détérioré. De l'autre côté il faut se méfier des dérangements trophiques de la peau. Le traitement physiothérapeutique est récommandé déjà pendant l'état I d'après Fontaine.
    Abstract: Zusammenfassung 1. Die konservative Behandlung einschließlich der physikalischen Behandlung der chronisch-arteriellen Durchblutungsstörung führt zu einer Besserung der Beschwerden durch eine Ökonomisierung des in der Extremität zur Verfügung stehenden Blutstromzeitvolumens, ohne daß durch die Therapie die Gesamtdurchblutung in allen Fällen gesteigert werden kann. Diese Ökonomisierung erfolgt vor allem durch eine Änderung der Blutstromverteilung, der Hämodynamik und des Stoffwechsels im Muskel. 2. Die konservative Behandlung muß die Gefahr trophischer Störungen der Haut berücksichtigen und entsprechend dosiert werden. Zur Kontrolle der Behandlung eignet sich der Rolltest nach Ratschow. 3. Die medikamentöse und physikalische Therapie kann auch dann erfolgreich sein, wenn Untersuchungen eine Minderung der Muskeldurchblutung ergeben haben. 4. Die aktive Übungsbehandlung ist bereits im symptomlosen Stadium I nach Fontaine indiziert.
    Notes: Summary Conservative treatment of chronic arterial occlusion disease in the lower extremities causes a subjective improvement by economising the blood flow in the legs without necessarily increasing the general blood flow. This economising is mainly due to changes of the hemodynamic and of the muscle metabolism. During conservative treatment the possibility of a decreasing blood flow in the skin has to be considered. Medicamentous and physical therapy can be used yielding subjective improvement, even in case of objective stated reduction of muscle blood flow due to this therapy. Active exercises are indicated already in the symptomless stage I according to of chronic arterial occlusion disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of thermal analysis and calorimetry 35 (1989), S. 443-457 
    ISSN: 1572-8943
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die isotherme Differentialthermoanalyse ist als Methode zur Abschätzung der thermooxidativen Beständigkeit von Polyolefinen seit längerem bekannt. In der vorliegenden Arbeit wird über isotherme DTA-Messungen an Proben aus vernetztem Polyäthylen im Temperaturbereich von 230°C bis 120°C berichtet, wobei Oxidationsinduktionszeiten bis zu 3590 Stunden gemessen wurden. Die Auftragung der Oxidationsinduktionszeiten in Arrhenius-Diagrammen zeigte für vernetztes Polyäthylen keine für Extrapolationszwecke geeignete Linearität des Logarithmus der Oxidationsinduktionszeiten über der reziproken absoluten Temperatur über weitere Bereiche der Meßzeiten bzw. Prüftemperaturen. Die thermoanalytisch bestimmten Oxidationsinduktionszeiten stimmten mit dem Steilabfall der Reißdehnung in Ofenalterungsversuchen überein während der über den Gelgehalt ermittelte Vernetzungsgrad vom thermooxidativen Abbau nicht signifikant beeinflußt wurde. Somit können aufwendige Ofenalterungsversuche durch experimentell einfache isotherme DTA-Versuche ersetzt werden. Die Messung der thermooxidativen Restbeständigkeit im isothermen DTA-Versuch bei erhöhter Prüftemperatur ermöglicht einen wesentlich deutlicheren Einblick in den thermooxidativen Schädigungszustand eines Polyolefins während der Induktionsperiode des thermooxidativen Abbaus als die Messungen des Vernetzungsgrades oder der Reißdehnung. Die Abnahme der thermooxidativen Restbeständigkeit erfolgt im Fall des vernetzten Polyäthylen in allen Fällen linear über der Alterungszeit.
    Abstract: Резюме Методом изотермичес кого ДТА изучена термоокислительная стабильность двух ви дов сшитого полиэтил ена в температурном интервале 120–230°. Времен а индукции термоокислительног о разрушения полимера были измерены в интер вале от 2 минут до 3590 часов. Индукционное время окисления и мех аническое повреждение в опытах по старению с овпадали во всем измеренном температурном интер вале. Степень сшивани я не сильно затрагивалась окислительной реакц ией. Аррениусовские графики данных ДТА показали перегиб при 150°, в связи с чем не представилось возможным провести э кстраполяцию от крат ковременных опытов при повышенных темпе ратурах до низких тем ператур и более длинных периодов вре мени. Термоаналитиче ски измеренная остаточн ая термоокислительная стабильность уменьш алась линейно с временем старения и п оказала большое расх ождение результатов.
    Notes: Abstract Isothermal differential thermal analysis has been used to study the thermooxidative stability of two grades of crosslinked polyethylene in the temperature range from 120°C to 230°C. Induction times of thermooxidative degradation were measured from 2 minutes up to 3590 hours. Oxidation Induction time and mechanical failure in oven ageing experiments coincided over the measured temperature range. The degree of crosslinking was not strongly affected by the oxidative reaction. The Arrhenius-plots of DTA results showed curvature at 150°C, so straight line extrapolations from short-term experiments at elevated temperatures to low temperatures and long times are not possible. Thermoanalytically measured residual thermooxidative stability decreased linearly with ageing time and showed great scattering of the results.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Journal of thermal analysis and calorimetry 35 (1989), S. 481-496 
    ISSN: 1572-8943
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Diffusion des phenolischen Antioxidanten 1, 3, 5-Tris (3,5-ditert.butyl-4-hydroxybenzyl)mesitylen (IRGANOX 1330) in zusammengepreßten, isotaktischen Polypropylenfolien wurde mittels isothermer Differentialthermoanalyse (DTA) über einen Temperaturbereich von 80°C bis 120°C untersucht. Die isothermen DTA-Messungen zeigten einen klaren Zusammenhang zwischen Oxidationsinduktionszeit und Oxidationsmaximumszeit und der Konzentration des Antioxidanten. Über die Bestimmung der Oxidationsmaximumszeiten von Folienstapeln aus isotaktischem Polypropylen war es möglich, die Diffusionskonstanten und Aktivierungsenergie der Diffusion von IRGANOX 1330 in iPP zu bestimmen. Um den Einfluß der Kristallstruktur auf die Diffusion von Stabilisatoren zu ermitteln, wurdedie gleiche Methode bei gepreßten Platten angewendet. Die Gefügestruktur (Kristallinitätsgrad und Sphärolithgröße) der Platten und Folien wurde mittels dynamischer DTA und Polarisationsmikroskop untersucht.
    Abstract: Резюме Методом изотермичес кого ДТА в интервале температур 80–120° изучена диффузия фенольного антиокис лителя 1, 3, 5-трис- /3, 5-ди-трет. бутил-4-оксибе нзил/мезитилена /Ирга нокс 1330/ в пресованных листах изотактического пол ипропилена / и-ПП/. Измерения показали я сную зависимость меж ду индукционным времен ем окисления и максимал ьным временем окисле ния/оба определяются изотермическим ДТА/и концентрацией стабилизатора. Путем измерения макс имального времени ок исления через стопку пластин изотактичес кого полипропилена, представилось возмо жным вычислить коэффицие нты диффузии и энерги ю активации процесса Диффузии антиокисли теля в и-ПП. Этот же сам ый метод был использован для измерения коэффи циентов диффузии антиокислителя Игранокс 1330 в прессован о-отлитых пластинах изотактического полипропилена. Влиян ие морфологической с труктуры и-ПП на процесс диффузии был изучен п утем измерения степе ни кристалличности пленок и пластин изот актического полипро пилена и определения размера сферулитов.
    Notes: Abstract The diffusion of the phenolic antioxidant 1, 3, 5-tris (3,5-ditert. butyl-4-hydroxybenzyl)mesitylene (IRGANOX 1330) in compressed sheets of isotactic polypropylene (iPP) was investigated over the temperature range from 80°C to 120°C by isothermal differential-thermal-analysis (DTA). The measurements showed a clear relation between oxidation induction time and oxidation maximum time, (both determined by isothermal DTA) and the concentration of stabilizer. It was possible to calculate the diffusion co-efficients and the activation energy of diffusion of IRGANOX 1330 in iPP by measuring the oxidation maximum times across stacks of isotactic polypropylene sheets. The same method was employed to measure the diffusion coefficient of IRGANOX 1330 in compressionmolded plates of iPP. The influence of the morphological structure of iPP on the diffusion process was investigated by measuring the cristallinity degree of iPP-films and-plates and the determination of the dimensions of the spherulites.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 257 (1979), S. 673-688 
    ISSN: 1435-1536
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Summary By relaxation and creep measurements on Polymethylmethacrylate (PMMA) and Polyvinylchloride (PVC) in the linear viscoelastic region below the glass transition temperature it is shown, that at different temperatures measured dispersion curves of the Young's Modulus can be shifted to a master curve to the first approximation, if it is used for the horizontal shifting parallel to the frequency axis a simple shifting principle based on the Eyring rate theory combined with an empirical vertical shifting. The molecular interpretation of this method to construct master curves and the technical importance of this method is discussed.
    Notes: Zusammenfassung Durch relaxationsspektroskopische Untersuchungen an Polymethylmethacrylat (PMMA) und an Polyvinylchlorid (PVC) im linearen hartelastischen Bereich wird nachgewiesen, daß die bei verschiedenen Temperaturen gemessenen Dispersionskurven des Elastizitätsmoduls sich in erster Näherung zu einer reduzierten Kurve vereinen lassen, wenn für die Horizontalverschiebung parallel zur Frequenzachse ein auf der Eyringschen Platzwechseltheorie basierendes einfaches Verschiebungsprinzip angewendet und gleichzeitig eine empirische Vertikalverschiebung vorgenommen wird. Die molekulare Deutung dieses Verfahrens zur Konstruktion von reduzierten Kurven und dessen technische Bedeutung werden diskutiert.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 258 (1980), S. 9-23 
    ISSN: 1435-1536
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Zusammenfassung Es wird über Messungen des dynamischen Elastizitätsmoduls und Schubmodells von Polymethacrylsäuremethylester (PMMA) im Frequenzbereich von 10−3 Hz bis 10−1 Hz und im Temperaturbereich von −20°C bis +100°C bei Spannungsamplituden bis zu 4 kN/cm2 berichtet. Das gemessene nichtlineare viskoelastische Verhalten wird hinsichtlich einer nichtlinearen Elastizität und hinsichtlich nichtlinearer Effekte, die durch eine Verschiebung der Relaxationszeiten nach der Platzwechseltheorie verursacht sind, diskutiert.
    Notes: Summary Measurements of the dynamic Youngs modulus and shear modulus of Polymethylmethacrylate (PMMA) in the frequency range from 10−3 cps to 10−1 cps and in the temperature range from −20°C to 100°C up to stress amplitudes of 4 kN/cm2 are presented. The measured nonlinear viscoelastic behavior is discussed with regard to nonlinear elasticity and nonlinear effects caused by the shift of relaxation times due to the reaction rate theory.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Archives of orthopaedic and trauma surgery 75 (1973), S. 226-238 
    ISSN: 1434-3916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Klinische Beobachtungen funktioneller und morphologischer Veränderungen nach Patellaquerfrakturen werden mit experimentellen und theoretischen biomechanischen Untersuchungsergebnissen verglichen. Auf die Besonderheiten der Belastung der Patella beim aktiven und passiven Bewegen mit und ohne Belastung, im Stehen und im Liegen sowie bei verschiedenen Gelenkstellungen wird hingewiesen. Eine gleichmäßige Biegebeanspruchung der Patella, insbesondere beim Bewegen, fehlt, so daß die Wirkung der einfachen Zuggurtungsosteosynthese nicht vorausgesehen werden kann. Die zusätzliche Anwendung von Kirschner-Drähten ist daher fast immer erforderlich. Auch die passiven Bewegungen des Kniegelenkes ohne Schwerkrafteinwirkung erfordern eine feste Osteosynthese wegen der Krafteinwirkung durch den serienelastischen Zug des M. quadriceps. Beim Gehen auf ebener Strecke kann die Zugbelastung der Patella sehr gering sein. Auch der pathologisch veränderte Patellagleitweg bleibt daher subjektiv unauffällig. Unter Berücksichtigung biomechanischer Überlegungen werden klinische Behandlungsmethoden und Ergebnisse besprochen. Trophische Störungen können die Behandlungsergebnisse nachteilig beeinflussen. Sie sind durch die geeignete Operationstechnik unter Verwendung von wenig Osteosynthesematerial und durch Verkürzung der Zeit vollkommener Ruhigstellung zum großen Teil vermeidbar.
    Notes: Summary Clinical observations of functional and morphological changes in consequence to patella fracture are compared with experimental and theoretical investigations. Traction and flexion force influencing on the fractured patella during active and passive exercises, in different knee positions, is discussed. Even in transverse fracture the approximate rate of flexion force in patella can rarely be controlled. Therefore difficulties exist in the estimation of the mechanical effect of osteosynthesis by anterior wire suture without splinting with length of Kirschner-wires. During walking on a plane way the forces influencing patella function are less in comparison to sitting etc. Clinical treatments and results are discussed from a point of view of M. biomechanical factor, which is not the only important one. Trophic disturbances can be avoided by careful method of operation using a small quantity of osteosynthesis material and by short complete immobilisation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1435-1536
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Rheologica acta 26 (1987), S. 548-559 
    ISSN: 1435-1528
    Keywords: Injection molding ; skin layer ; crystallization kinetics ; chainorientation ; polypropylene
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Abstract The thickness of highly oriented skin layers is determined on 2-mm-thick plates injected under different processing conditions by birefringence measurements. Two technical polypropylene types of different molar mass distributions are used. Measurements on samples injected with and without pressure hold after filling make it possible to decide between chain orientation caused during injection and chain orientation caused by the pressure hold after filling. Different models for the calculation of the oriented layer thickness are discussed. The results reveal that the highly oriented skin layers are already formed during the filling phase and that thickness is probably determined through the opposing development of stress-induced crystallization and relaxation. Further measurements indicate that at the injection molding without pressure hold after filling, the melt can relax between the skin layers and can be strongly supercooled before it crystallizes.
    Notes: Zusammenfassung An 2 mm dicken unter verschiedenen Bedingungen spritzgegossenen Platten aus zwei Polypropylentypen mit unterschiedlicher Molmassenverteilung wird durch Messung der optischen Doppelbrechung die Dicke der hochorientierten Randschichten bestimmt. Durch solche Messungen an Platten, die mit und ohne Nachdruck gespritzt wurden, lassen sich die während der Füllphase von den während der Nachdruckphase entstandenen Orientierungsanteilen trennen. Möglichkeiten der theoretischen Berechnung der Randschichtdicke werden diskutiert. Hieraus ergibt sich, daß die hochorientierten Randschichten bereits während des Füllvorganges entstehen und deren Dicke vermutlich durch die Konkurrenz zwischen scherinduzierter Kristallisation und Relaxation bestimmt wird. Beim Spritzen ohne Nachdruck kann die Schmelze in der Mitte der Platte zwischen den Randschichten relaxieren und stark unterkühlt werden, bevor sie kristalliert, wie durch zusätzliche Messungen nachgewiesen wurde.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1435-1528
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Zusammenfassung Eine einfache Meßanordnung wird beschrieben, mit der sowohl die dynamische wie auch die statische Bestimmung des Elastizitätsmoduls und des Schubmoduls hochpolymerer Stoffe durchgeführt werden kann. Meßergebnisse werden mitgeteilt und diskutiert. Schrifttum
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...