Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 111 (1999), S. 10411-10414 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: Dissociative adsorption of H2 from a high-flux supersonic molecular beam on flat and vicinal Si(001) surfaces was investigated by means of optical second harmonic generation (SHG). The initial sticking coefficients for terrace adsorption varied between 10−8 and 10−4. They revealed a strongly activated dissociation process, both with respect to the kinetic energy of the incident molecules (70 meV≤Ekin≤380 meV) and the surface temperature (440 K≤Ts≤670 K). The results indicate that dynamical distortions of Si surface atoms can lower the effective adsorption barriers from 0.8±0.2 eV to almost negligible values. Previously proposed defect-mediated processes can be ruled out as a major adsorption channel. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-0385
    Keywords: Schlüsselwörter: Distraktionsosteogenese ; Regeneratkonsolidierung ; rekombinantes Wachstumshormon ; IGF-I ; Minischwein ; Biomechanik. ; Keywords: Distraction osteogenesis ; Recombinant growth hormone ; Insulin-like growth factor ; Regenerate strength ; Mechanical testing ; Micropig.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract. Distraction osteogenesis is a good model for evaluation of fracture healing with intramembranous bone formation. The purpose of the present study was to investigate whether homologous GH has a stimulating effect on bone healing in distraction osteogenesis. The left tibiae of 30 micropigs were osteomized and distracted with an external fixator 2 mm daily over a period of 10 days. Animals were killed after an additional healing time of 10 days. The treatment group received 100 μg r-pGH per kg bodyweight per day. A newly developed device allowed non-destructive torsional biomechanical evaluation of the regenerate strength as in vivo measurements. After killing, destructive torsional strength testing of the sites of distraction was performed. To determine the endocrine response to the administration of r-pGH, serum levels of IGF-I were determined. The non-destructive in vivo testing showed that torsional stiffness of the regenerate was significantly higher in the treatment group than in the control group. Final regenerate torsional failure load was 131 % higher and ultimate torsional stiffness was 231 % higher in the treatment group than in the control group. The mean serum level of IGF-I increased to 440 % of the preoperative base level in the treatment group and remained unchanged in the control group. Our data indicate that systemic administration of recombinant homologous growth hormone significantly accelerates ossification of bone regenerate in distraction osteogenesis.
    Notes: Zusammenfassung. Das Ziel der vorliegenden Untersuchung war es zu überprüfen, ob systemisch appliziertes spezies-spezifisches rekombinantes Wachstumshormon (GH) die Knochenheilung stimulieren kann. Hierfür wurde die linke Tibia von 30 Yucatan Minischweinen osteotomiert, über einen Halbringfixateur stabilisiert und 2 mm/Tag für 10 Tage distrahiert. Daran schloß sich eine 10tägige Konsolidierungsphase an. Die eine Hälfte der Tiere erhielt täglich subcutan rekombinantes porcines Wachstumshormon (r-pGH) 100 μg/kg KG, die andere Hälfte NaCl als Placebo injiziert. Mittels einer eigens entwickelten Meßvorrichtung konnte in-vivo im Zeitverlauf wiederholt die torsionale Steifigkeit der Regenerate bestimmt werden. Nach Tötung der Tiere wurde von den distrahierten Tibiae und den jeweiligen gesunden kontralateralen Tibiae die torsionale Bruchkraft in einer Materialprüfmaschine ermittelt. Um die endokrine Antwort der r-pGH-Applikation zu überprüfen, wurden die Serumspiegel von Insulin-like growth factor I (IGF-I) bestimmt. Während der gesamten Konsolidierungsphase zeigte die Versuchsgruppe signifikant höhere in-vivo Steifigkeitswerte als die Kontrollgruppe. Dabei lagen die Unterschiede zwischen 61 % (Tag 1), 101 % (Tag 4) und 81 % am Versuchsende (Tag 10 der Konsolidierungsphase). Die postmortale torsionale Bruchkraft im Vergleich zur gesunden kontralateralen Seite wies 64 ± 22,4 % in der hormonbehandelten Gruppe im Gegensatz zu 26 ± 12,9 % in der Kontrollgruppe auf. Die IGF-I Serumspiegel waren in der behandelten Gruppe um mehr als das 4 fache erhöht, während in der Kontrollgruppe keine signifikante Veränderung zu sehen war. Unsere Ergebnisse zeigen, daß die systemische Gabe von r-pGH eine starke Beschleunigung der Regeneratkonsolidierung bei der Callusdistraktion am Minischwein bewirkt. Diese knochenanabole Wirkung von GH könnte in der Zukunft eine Behandlungsoption bei der Distraktionsosteogenese darstellen und dazu beitragen, die Behandlungsdauer zu Gunsten des Patienten zu verkürzen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1433-0385
    Keywords: Schlüsselwörter: Frakturheilung ; biodegradierbar ; Poly(D ; L-Lactid) ; IGF-I ; TGF-β1. ; Keywords: Fracture healing ; Biodegradable ; Poly(D ; L-lactide) ; IGF-I ; TGF-β1.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract. In vitro and in vivo studies have demonstrated an osteoinductive effect of growth factors like IGF-I and TGF-β1. However, for therapeutic use in fracture treatment, the local application of these bioactive molecules is still an unsolved problem. The controlled release of growth factors from a biodegradable coating of osteosynthetic implants could stimulate fracture healing locally. Coated implants could stabilise the fracture and work as a local drug delivery system. Previous studies demonstrated a high mechanical stability of a thin 10 μm poly(D,L-lactide) (PDLLA) coating on metallic implants that withstands even an intramedullary insertion process. After an initial peak, 80 % of incorporated growth factors IGF-I and TGF-β1 were continuously released within 42 days. The effect of locally applied IGF-I and TGF-β1 from a biodegradable PDLLA coating of intramedullary implants on fracture healing were investigated in a rat model. A fracture of the right tibia of 5-month-old female Sprague-Dawley rats was stabilised with coated versus uncoated titanium K-wires. X-ray examinations and blood analysis were performed, body weight and body temperature monitored throughout the experimental period. After 42 days both tibiae were dissected for mechanical torsional testing and histomorphometric analyses. The results demonstrate a nearly completely consolidated fracture in the X-ray examinations, a significant higher maximum load and torsional stiffness in the biomechanical tests and a progressed remodeling in the histological and histomorphometric analyses after 42 days in the group treated with growth factors compared to the controls. Interestingly, the PDLLA coating itself had a positive effect on fracture healing even without incorporated growth factors. No systemic change of serum parameters including IGF-I and IGF binding proteins and no differences in body weight and body temperature were seen in any group. These findings suggest that the local application of growth factors from a biodegradable poly(D,L-lactide) coating of osteosynthetic implants accelerates fracture healing significantly without systemic side effects.
    Notes: Zusammenfassung. In zahlreichen in vitro und in vivo Studien konnte eine osteoinduktive Wirkung von Wachstumsfaktoren, wie IGF-I oder TGF-β1 nachgewiesen werden. Die lokale Applikation der Faktoren für einen therapeutischen Einsatz bei der Frakturheilung stellt jedoch ein Problem dar. Die kontinuierliche Freisetzung von Wachstumsfaktoren aus einer biodegradierbaren Beschichtung von Implantaten könnte die Frakturheilung lokal stimulieren. Das beschichtete Osteosynthesematerial würde einerseits die Fraktur stabilisieren und gleichzeitig als „Carrier“ für die lokale Freisetzung von Wirksubstanzen dienen. Vorversuche zeigten eine hohe mechanische Stabilität einer 10 μm dünnen Poly(D,L-Lactid)-Beschichtung (PDLLA) auf Metalloberflächen, die einer intramedullären Implantation zu 96 % standhielt. Nach einem initialen Peak wurden 80 % der eingearbeiteten Wachstumsfaktoren IGF-I und TGF-β1 kontinuierlich über einen Zeitraum von 42 Tagen aus der Beschichtung freigesetzt. An einem Rattenmodell wurde der Effekt der PDLLA-Beschichtung und der eingearbeiteten Wachstumsfaktoren auf die Frakturheilung untersucht. Eine Fraktur der rechten Tibia von 5 Monate alten weiblichen Sprague Dawley Ratten wurde mit beschichteten versus unbeschichteten Titan-Kirschner-Drähten stabilisiert. Es folgten radiologische Verlaufsuntersuchungen und die Analyse von Serumparametern. Das Körpergewicht und die Körpertemperatur wurden gemessen, um systemische unerwünschte Wirkungen zu erfassen. Nach 42 Tagen wurden die Knochen biomechanisch torsional getestet sowie histologisch und histomorphometrisch untersucht. Die Ergebnisse zeigten in der mit Wachstumsfaktoren behandelten Gruppe nach 42 Tagen in der radiologischen Untersuchung eine komplett durchbaute Fraktur, ein signifikant höheres maximales Drehmoment und eine signifikant höhere Torsionssteifigkeit in der biomechnischen Testung sowie histologisch ein fortgeschrittenes Remodeling im Vergleich zu den Kontrollgruppen. Die PDLLA-Beschichtung alleine, ohne eingearbeitete Wachstumsfaktoren, zeigte bereits einen positiven Effekt auf die Frakturheilung. Die Untersuchung der Serumparameter, des systemischen IGF-I und dessen Bindungsproteine sowie des Körpergewichts und der Körpertemperatur ergaben keine Unterschiede in den Gruppen. Die Untersuchungen belegen, daß die lokale Freisetzung von IGF-I und TGF-β1 aus einer biodegradierbaren PDLLA Beschichtung von Implantaten die Frakturheilung signifikant beschleunigt, wobei keine unerwünschten Wirkungen beobachtet werden konnten.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1433-044X
    Keywords: Schlüsselwörter Tibiakopffraktur ; Ilizarov-Hybrid-Fixation ; Supportive Osteosynthese ; Weichteilschaden ; Minimal-invasive Technik ; Key words Tibial plateau fractures ; Ilizarov hybrid fixation ; Supportive fixation ; Softtissue damage ; Minimal invasive technique
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Recent operative techniques with percutaneous screw fixation of the tibial plateau require a high level of patient compliance. Geriatric, non-cooperative patients and fractures with severe soft tissue injury have had to be excluded so far from this ther-apeutic regimen. Since September 1993, composite hybrid fixation, as a combination of ring fixation of the epimetaphyseal tibia with monolateral AO fixation of the tibial shaft, has been performed in 12 patients. The data were collected prospectively. Fractures were classified according to the AO and Moore classification; soft tissue damage was classified according to Tscherne and Gustilio. Fixation was performed with the cannulated AO system, 2.0 mm titanium K wires and 5.0 mm AO Schanz screws. In five patients, additional arthroscopic control of the reposition was performed. Average removal of the external fixator was 16 weeks postoperatively. Pin-tract infections occurred in all patients, mainly in the metaphyseal region. In one patient, a knee infection resulted from a subchondral intra-articular pin, which was treated by repetitive arthroscopic synovectomy. In two patients, a secondary loss of reposition (5 – 7° varus) occurred. Despite a high rate of soft tissue damage (8/12), no osteitis or nonunion occurred. As an alternative to extensive methods of ORIF, supportive composite hybrid fixation offers a new perspective of early functional treatment, weight bearing and a rare loss of reposition. It is favored in geriatric, non-cooperative patients and in fractures with severe soft tissue damage.
    Notes: Alternativ zu aufwendigen internen Stabilisierungsverfahren bietet die supportive Composite-Hybridfixation bei Tibiakopffrakturen eine neue Perspektive der frühfunktionellen Nachbehandlung mit seltenem Repositionsverlust bei frühzeitiger Vollbelastung. Sie wird bevorzugt bei geriatrischen und alkoholabhängigen Patienten sowie bei Frakturen mit höhergradigem Weichteilschaden eingesetzt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-0428
    Keywords: Dog ; insulin therapy ; mathematical model ; soluble insulin ; depot insulin ; absorption ; subcutaneous
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The appearance rate of insulin (calculated insulin secretion rate) in the circulating blood after subcutaneous injection was estimated in diabetic dogs from serial measurements of immunoreactive insulin concentrations using a simple mathematical model based on the insulin half-life and the distribution space. In the case of highly purified monocomponent porcine insulin, maximum concentrations occurred after 30–60 min. The duration of insulin appearance was dose-dependent and the rate of appearance could be described by a bi-exponential function. It was linearly dose-dependent but the effect on glycaemia showed saturation kinetics. The action of the injected dose on the fasting glycaemia diminished when the appearance rate became 〈0.3 mU · kg-1 · min-1. Fractional dose recovery was between 70% and 90% and was not different between depot and regular insulin. Appearance kinetics were not significantly affected by the initial glycaemia. The model presented provides a means for quantitative characterization of different insulin preparations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 372 (1987), S. 942-942 
    ISSN: 1435-2451
    Keywords: Stomach in man ; Blood vessels ; Peptic ulcer ; Menschliche Magen-Mucosa ; Angioarchitektur ; Ulcus ventriculi
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die Angioarchitektur menschlicher Magen Corpus Mucosa wurde an 14 Operationspräparaten im Rasterelektronenmikroskop und an Semidünnschnitten untersucht. Die Befunde zeigen erstmalig, dass die Mikrozirkulation in der Mucosa des Corpus ventriculi auf zwei übereinan-derliegenden Capillarebenen erfolgt. Dieses Prinzip gewährleistet eine luxuriöse Sauerstoffversorgung in allen Bereichen der Corpusschleimhaut. Es könnte einen protektiven Faktor hinsichtlich der geringen Ulcushäufigkeit im Corpus ventriculi darstellen.
    Notes: Summary The angioarchitecture of the gastric corpus mucosa in man was examined in 14 surgical specimens by scanning electron microscopy and semithin sections. The existence of two capillary layers in the gastric corpus mucosa is demonstrated. The distribution of the blood vessels leads to luxurious oxygenation throughout all layers in this area. This might be a protective factor being responsible for the low incidence of peptic ulcers in the corpus ventriculi.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1433-0385
    Keywords: Key words: Segmental bone defects ; Callus distraction ; Unreamed interlocking nails ; Bone transport. ; Schlüsselwörter: Knochensegmentdefekte ; Callusdistraktion ; ungebohrte Verriegelungsnägel ; Knochentransport.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung. Eine Behandlungsmethode bei Knochensegmentdefekten und Beinverkürzungen wird vorgestellt, die aus einer Osteotomie mit anschließendem Segmenttransport durch einen anteromedial (Tibia) oder lateral (Femur) angebrachten AO-Transportfixateur externe über einen ungebohrten Verriegelungsnagel besteht (Monorail-System). Zwanzig Patienten wurden mit diesem Verfahren bei unterschiedlichen Indikationsstellungen behandelt. Dreizehn wiesen einen Knochensegmentdefekt der Tibia und 3 Patienten des Femur auf, 3 Patienten hatten eine posttraumatische bzw. postinfektiöse Beinlängendifferenz und einer eine hypertrophe Pseudarthrose des Oberschenkels. Die Defektstrecken bzw. Beinlängendifferenz variierten zwischen 5 und 18,5 cm. Die durchschnittliche Transportzeit betrug 19,42 d/cm bei Tibiaschaftdefekten, 15,93 d/cm am Oberschenkel. Es traten 2 Systemversager auf, die eine Markraumphlegmone entwickelten und durch Verfahrenswechsel zum Ilizarov-Ringfixateur ausbehandelt wurden. Trotz Komplikationen beim Monorail-Verfahren kam es in keinem Fall zur nachfolgenden Amputation der Extremität. Das Monorail-Distraktionssystem ist bei genauer Indikationsstellung eine Alternative zu anderen Callusdistraktionsverfahren, insbesondere dem Ilizarov-Ringfixateur. Ein Algorithmus bei Knochensegmentdefekten ohne Infekt unter Berücksichtigung von Weichteilschäden mit und ohne neurovasculäre Komponenten ist erstellt.
    Notes: Summary. A treatment protocol is demonstrated, consisting of an osteotomy, either proximal or distal, of the bone defect with subsequent segmental transport via an anteromedially (tibia) or laterally (femur) mounted AO external fixation over an unreamed interlocking nail (monorail system). Twenty patients were treated by this method with indications as follows: 13 had a segmental bone defect of the tibia, 3 of the femur. Three patients showed post-traumatic and postinfectious leg-length discrepancies and one was treated for hypertrophic non-union of the femur. Defect distance varied between 5 and 18.5 cm and average time for transport was 19,42 days/cm for the tibial shaft, 15,93 days/cm for the femur. Two patients developed deep infection, which required change of treatment, removing the monorail system and application of an Ilizarov apparatus. Despite complications using the monorail system, all patients healed and no amputations were required. The monorail system can be used as an alternative to the Ilizarov method under certain criteria of patient selection; these criteria are shown by an algorithm for segmental bone defects without infection, respecting the soft-tissue status with or without neurovascular compromise.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1433-044X
    Keywords: Schlüsselwörter Ilizaroz-Ringfixateur ; Steifigkeit ; Frakturheilung ; Präoperative Planung ; Key words Ilizarov ring fixator ; Stiffness ; Fracture healing ; Pre-operative planing
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Using a mechanical testing procedure, various fixator constructs were tested in vitro. In addition, the influence of the passive soft tissue structures on the fixation stiffness was determined. An increased number of Schanz' screws or Kirschner wires led to a comparable increase in stiffness than that observed with an increasing screw or wire diameter. In consequence, larger diameters should be preferred over an additional screw or wire where clinically applicable. With diaphyseal telescoping rods only the axial stiffness decreased. As expected, large ring diameters as well as titanium wires reduced stiffness components. Bracing the outer rings caused a reduction of the overall stiffness. Asymmetric pre-tensioning of the K-wires resulted in a significant reduction of tension in the neighboring wire. Removal of the soft tissues reduced stiffness to a similar extend as experienced in a fibula defect situation. The study demonstrates the correlation between design parameters, passive soft tissues and fixation stiffness and presents guidelines for an optimized fixator design.
    Notes: Zusammenfassung Mit Hilfe eines mechanischen Testverfahrens wurden nach Variation ausgewählter Gestaltparameter klinisch eingesetzte Fixateurkonfigurationen in vitro untersucht. Zusätzlich wurde der Einfluss der passiven Weichteile an humanen Präparaten ermittelt. Eine Erhöhung der Anzahl der Schanz-Schrauben bzw. der Kirschner-Drähte bewirkte eine vergleichbare Steigerung der Steifigkeit wie eine Erhöhung des Durchmessers der Schrauben bzw. Drähte. Wo klinisch zulässig, sind daher größere Durchmesser anstelle einer höheren Anzahl der Schrauben bzw. Drähte zu empfehlen. Eine Reduzierung des Ringdurchmessers führte zu einer Steifigkeitszunahme. Bei Verwendung von diaphysären Transportspindeln nahm allein die Axialsteifigkeit ab. Wie erwartet, verringerten Titandrähte im Vergleich zu CoCr-Drähten fast alle Steifigkeitskomponenten. Nach gegenseitigem Verspannen der äußeren Ringebenen nahm die Gesamtsteifigkeit ab. Ein asymmetrisches Vorspannen der Kirschner-Drähte bewirkte einen Spannungsabfall im benachbarten Draht. Nach Entfernen des Weichteilmantels sank die gesamte Steifigkeit der Fixation im gleichen Ausmaß wie bei einem Defekt der Fibula. Die Studie zeigt die Zusammenhänge zwischen Gestaltparametern, passivem Weichteilmantel sowie Fixationssteifigkeit und gibt Richtlinien für die Fixateurgestaltung.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...