Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 2208-2210 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A method for designing open gradient coils for magnetic resonance imaging using a simulated annealing optimization algorithm is described. The algorithm allows the current density toward the open end to be increased, compensating for the "missing" coil section. A semicylindrical transverse z gradient has been designed and built providing a gradient efficiency of 0.82 mT/m/A. The prototype provided good agreement with the theory over the central imaging region. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Cambridge : Cambridge University Press
    Bulletin of the School of Oriental and African Studies 61 (1998), S. 383-384 
    ISSN: 0041-977X
    Source: Cambridge Journals Digital Archives
    Topics: Ethnic Sciences , History
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Cambridge : Cambridge University Press
    Bulletin of the School of Oriental and African Studies 60 (1997), S. 402-402 
    ISSN: 0041-977X
    Source: Cambridge Journals Digital Archives
    Topics: Ethnic Sciences , History
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1573-6865
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary The purpose of this investigation was to examine critically the validity of a computerized quantitative microphotometric histochemical technique for the determination of succinate dehydrogenase (SDH) activity in skeletal muscle fibres. Sections from the anterior costal diaphragm were removed from Fischer-344 rats (n = 12) and assayed histochemically to determine SDH activity. The SDH activity in individual muscle fibres was computed using a computerized microphotometric histochemical technique which involves measurement of the optical density of deposited diformazan derived from nitroblue tetrazolium within the fibres. To validate the histochemical technique, whole muscle SDH activities were calculated from the histochemical procedure and were compared to SDH activities determined from whole muscle homogenates via a standard quantitative biochemical assay. The mean within-day variability of the computerized microphotometric histochemical technique of determining SDH activity was 6% (range = 0.5–10.9%) for an area containing ~50 fibres and 6.1% (range = 1.05–14.9%) for an individual muscle fibre. Similarly, the mean between-day variability of the microphotometric histochemical technique of determining SDH activity was 5.9% (range = 2.6–13.9%) for an area containing ~50 fibres and 6.6% (range = 2.2–13.9%) for an individual muscle fibre. The inter-class correlation coefficient between biochemically determined SDH activity and histochemically determined SDH activity was r = 0.83 (p 〈 0.05). Collectively, these data demonstrate that the quantitative histochemical technique of Blanco et al. (1988) is both valid and reliable in the determination of SDH activity in skeletal muscle fibres.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 52 (1984), S. 173-177 
    ISSN: 1439-6327
    Keywords: Anaerobic threshold ; Ventilatory threshold ; Exercise ventilation ; Gas exchange ; Blood lactate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Anaerobic threshold has been defined as the oxygen uptake ( $$\dot V_{{\text{O}}_{\text{2}} }$$ ) at which blood lactate (La) begins to rise systematically during graded exercise (Davis et al. 1982). It has become common practice in the literature to estimate the anaerobic threshold by using ventilatory and/or gas exchange alterations. However, confusion exists as to the validity of this practice. The purpose of this study was to examine the precision with which ventilatory and gas exchange techniques for determining anaerobic threshold predicted the anaerobic threshold resolved by La criteria. The anaerobic threshold was chosen using three criteria: (1) systematic increase in blood La (ATLa), (2) systematic increase in ventilatory equivalent for O2 with no change in the ventilatory equivalent for CO2 ( $${\text{AT}}_{\dot V_{\text{E}} } /\dot V_{{\text{O}}_{\text{2}} }$$ ), and (3) non-linear increase in expired ventilation graphed as a function of $$\dot V_{{\text{O}}_{\text{2}} }$$ ( $${\text{AT}}_{\dot V_{\text{E}} }$$ ). Thirteen trained male subjects performed an incremental cycle ergometer test to exhaustion in which the load was increased by 30 W every 3 minutes. Ventilation, gas exchange measures, and blood samples for La analysis were obtained every 3rd min throughout the test. In five of the thirteen subjects tested the anaerobic threshold determined by ventilatory and gas exchange alterations did not occur at the same $$\dot V_{{\text{O}}_{\text{2}} }$$ as the ATLa. The highest correlation between a gas exchange anaerobic threshold and ATLa was found for $${\text{AT}}_{\dot V_{\text{E}} } /\dot V_{{\text{O}}_{\text{2}} }$$ and was r=0.63 (P〈0.05). These data provide evidence that the ATLa and $${\text{AT}}_{\dot V_{\text{E}} }$$ do not always occur simultaneously and suggest limitations in using ventilatory or gas exchange measures to estimate the ATla.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1439-6327
    Keywords: Exercise ; Induced hypoxemia ; Incremental exercise ; Trained athletes ; Arterial oxyhemoglobin saturation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Recent evidence suggests that exercise-induced hypoxemia (EIH) may occur in healthy trained endurance athletes. However, at present, no data exist to describe the regularity of EIH in athletes or non-athletes. Therefore, the purpose of the present investigation was to determine the incidence of EIH during exercise in healthy subjects varying in physical fitness. Subjects (N=68) performed an incremental cycle ergometer test to volitional fatigue with percent arterial oxyhemoglobin saturation (%SaO2) measured min-by-min. For the purpose of data analysis subjects were divided into three groups according to their level of physical training: 1) untrained (N=16), 2) moderately trained (N=27), and 3) elite highly trained endurance athletes (N=25). EIH was defined as a %SaO2 of ≤91% during exercise. EIH did not occur in any of the untrained subjects or the moderately trained subjects. However, EIH occurred in 52% of the highly trained endurance athletes tested and was highly reproducible (r=0.95; P〈0.05). These findings further confirm the existence of EIH in healthy highly trained endurance athletes and suggests a rather high incidence of EIH in this healthy population. Hence, it is important that the clinician or physiologist performing exercise testing in elite endurance athletes recognize that EIH can and does occur in the elite endurance athlete in the absence of lung disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1439-6327
    Keywords: Electrolytes ; Fluid balance ; Glucose ; Exercise metabolism ; Blood pH
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The purpose of these experiments was to examine the influence of various fluid replacement drinks on exercise-induced disturbances in homeostasis during heavy exercise. Nine trained cyclists performed constant load exercise on a cycle ergometer to fatigue on three occasions with 1-week separating experiments. The work rate was set initially at ∼ 85% of $$\dot V_{o_{2{\text{ }}max} } $$ (range 82–88%) with fatigue being defined as a 10% decline in power output below the initial value. During each experiment subjects consumed one of the following three beverages prior to and every 15 min during exercise: (1) non-electrolyte placebo (NEP; 31 mosmol · kg−1); (2) glucose polymer drink containing electrolytes (GP; 7% CHO, 231 mosmol · kg−1), and (3) electrolyte placebo drink without carbohydrate (EP; 48 mosmol · kg−1). Both the GP and EP beverage contained sodium citrate/citric acid (C) as a flavoring agent while C was not contained in the NEP drink. Although seven of nine subjects worked longer during the GP and EP treatment when compared with the NEP trial, the difference was not significant (P〉0.05). No differences (P〉0.05) existed between the GP and EP treatments in performance time. Exercise changes in rectal temperature, heart rate, Δ % plasma volume and plasma concentrations of total protein, free fatty acids, glucose, lactate, potassium, chloride, calcium, and sodium did not differ (P〉0.05) between trials. In contrast, blood hydrogen ion concentration [H+] was significantly lower (P〈0.05) at 30 min of exercise during the GP and EP treatment when compared with the NEP run. These data provide evidence that electrolyte drinks do not minimize exercise-induced disturbances in blood-electrolyte concentrations during heavy execrcise when compared with nonelectrolyte drinks; however, these results suggest that fluid replacement beverages containing buffers (i.e. C) and/or electrolytes may minimize blood alterations in [H+] during intense exercise. Additional research is required to determine if the buffering influence of these beverages has an ergogenic benefit during heavy exercise.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 54 (1985), S. 306-308 
    ISSN: 1439-6327
    Keywords: Oxygen uptake kinetics ; $$\dot V_{{\text{O}}_{{\text{2max}}} }$$ ; Exercise metabolism ; Trained athletes ; Gas exchange
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Previous work has shown that when $$\dot V_{{\text{O}}_{\text{2}} }$$ kinetics are compared for endurance trained athletes and untrained subjects, the highly trained athletes have a faster response time. However, it remains to be determined whether the more rapid adjustment of $$\dot V_{{\text{O}}_{\text{2}} }$$ toward steady state in athletes is due to $$\dot V_{{\text{O}}_{{\text{2max}}} }$$ differences or training adaptation alone. One approach to this problem is to study the time course of $$\dot V_{{\text{O}}_{\text{2}} }$$ kinetics at the onset of work in athletes who differ in $$\dot V_{{\text{O}}_{{\text{2max}}} }$$ but have similar training habits. Therefore, the purpose of these experiments was to compare the time course of $$\dot V_{{\text{O}}_{\text{2}} }$$ kinetics at the onset of exercise in athletes with similar training routines but who differ in $$\dot V_{{\text{O}}_{{\text{2max}}} }$$ . Ten subjects ( $$\dot V_{{\text{O}}_{{\text{2max}}} }$$ range 50–70 ml · kg−1 · min−1) performed 6-minutes of cycle ergometer exercise at ∼50% $$\dot V_{{\text{O}}_{{\text{2max}}} }$$ . Ventilation and gas exchange were monitored by open circuit techniques. The data were modeled with a single component exponential function incorporating a time delay, (T D ); $$\Delta \dot V_{{\text{O}}_{{\text{2}}f} } = \Delta \dot V_{{\text{O}}_{2ss} } {\text{ (1}} - e^{ - t - T_D /_{\tau )} }$$ , where Τ is the time constant $$\Delta \dot V_{{\text{O}}_{{\text{2}}f} }$$ is the increase in $$\dot V_{{\text{O}}_{\text{2}} }$$ at time t and $$\Delta \dot V_{{\text{O}}_{{\text{2ss}}} }$$ is the steady-rate increment above resting $$\dot V_{{\text{O}}_{\text{2}} }$$ . Kinetic analysis revealed a range of $$\dot V_{{\text{O}}_{\text{2}} }$$ half times from 21.6 to 36.0 s across subjects with a correlation coefficient of r=−0.80 (p〈0.05) between $$\dot V_{{\text{O}}_{{\text{2max}}} }$$ and $$\dot V_{{\text{O}}_{\text{2}} }$$ half time. These data suggest that in highly trained indicivuals with similar training habits, those with a higher $$\dot V_{{\text{O}}_{{\text{2max}}} }$$ achieve a more rapid $$\dot V_{{\text{O}}_{\text{2}} }$$ adjustment at the onset of work.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Magnetic resonance materials in physics, biology and medicine 3 (1995), S. 49-55 
    ISSN: 1352-8661
    Keywords: biplanar B0 coils ; shielded design ; minimum energy ; minimum power
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics
    Notes: Abstract By extending the formalism previously developed for the design of unshielded, biplanar gradient coils, shielded biplanarB 0 coils optimized for homogeneity and either minimum energy or minimum power may be designed. We present results from an integrated approach to shielded biplanar coil design, the results of which are also applicable to gradient coils, enabling the design of shielded coils with a concomitant decrease in total inductance of the coil. Length constraints are also included in the integrated minimization procedure. Results from a preliminary design indicate that high-homogeneity, low-impedance, well-shielded coils result from this design approach.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...