Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Anästhesie ; Aortenaneurysma ; Gefäßprothese ; Stent ; Komplikationen ; Key words Anaesthesia ; Aneurysm ; aortic ; Aorta ; Prostheses ; stents ; Complications
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Surgical treatment of aortic aneurysms carries significant cardiovascular risks. Transvascular insertion of endoluminal prostheses is a new, minimally invasive treatment for aortic aneurysms. The pathophysiology of this novel procedure, risks and benefits of different anaesthetic techniques, and typical complications need to be defined. Methods. With their informed, written consent, 19 male patients aged 48–83 years of ASA physical status III and IV with infrarenal (n=18) or thoracic (n=1) aortic aneurysms underwent 23 stenting procedures under general endotracheal (n=9), epidural (n=8), or local anaesthesia with sedation (n=6). Intra-anaesthetic haemodynamics, indicators of postoperative (p.o.) oxygenation and systemic inflammatory response, and perioperative complications were analysed retrospectively and compared between anaesthetic regimens. Results. Groups were well matched with regard to morphometry and preoperative risk profiles (Table 1). The use of pulmonary artery pressure monitoring, incidence of intraoperative hypotensive episodes, and p.o. intensive care was more frequent with general anaesthesia. Groups did not differ in total duration of anaesthesia care, incidence and duration of intraoperative hypertensive, brady-, or tachycardic periods, incidence of arterial oxygen desaturation, use of vasopressors, colloid volume replacements, or antihypertensives (Table 2). Postoperatively, all groups showed a similar, significant systemic inflammatory response, i.e., rapidly spiking temperature (p.o. evening: mean peak 38.5±1.0° C), leucocytosis, and rise of acute-phase proteins without bacteraemia (Table 3). During this period, despite supplemental oxygen, pulse oximetry revealed temporary arterial desaturation in 13 of 18 patients (70%) (Table 3). In 3 patients, hyperpyrexia was associated with intermittent tachyarrhythmias (n=3) and angina pectoris (n=1). There was no conversion to open aortic surgery, perioperative myocardial infarction, or death. Conclusions. Regional and local anaesthesia with sedation are feasible alternatives to general endotracheal anaesthesia for minimally invasive treatment of aortic aneurysms by endovascular stenting. However, invasive monitoring and close postoperative monitoring are strongly recommended with either method. Specific perioperative risks in patients with limited cardiovascular or pulmonary reserve are introduced by the abacterial systemic inflammatory response to aortic stent implantation. Hyperpyrexia increases myocardial and whole-body oxygen consumption, and can precipitate tachyarrhythmias. Hyperfibrinogenaemia may increase the risk of postoperative arterial and venous thromboses. Close monitoring of vital parameters and prophylactic measures, including oxygen supplementation, low-dose anticoagulation, antipyretics, and fluid replacement are warranted until this syndrome resolves.
    Notes: Zusammenfassung Die transvaskuläre Plazierung endoluminaler Gefäßprothesen mittels interventionell-radiologischer Methoden ist ein neues, minimal invasives Verfahren zur Therapie von Aortenaneurysmen. Wir analysierten retrospektiv die Praktikabilität verschiedener Anästhesieverfahren, die pathophysiologischen Auswirkungen des Eingriffs und typische Risiken. Bei 19 Patienten mit Aneurysmen der infrarenalen (n=18) oder der thorakalen Aorta (n=1) wurden in 23 Eingriffen aortale Stentprothesen implantiert. Die Eingriffe erfolgten in Allgemeinanästhesie (AA: n=9), in Periduralanästhesie (PDA: n=8) oder Lokalanästhesie (LA: n=6) mit Analgosedierung. Trotz erhöhten Überwachungsaufwands in der Gruppe AA ergaben sich keine Unterschiede in folgenden Parametern: Inzidenz und Dauer intraoperativer hypertensiver, brady- oder tachykarder Phasen; Einsatz von Vasopressoren, Antihypertensiva oder Volumenersatz. Hypotensive Episoden waren bei Allgemeinanästhesien häufiger. Postoperativ zeigten alle Patienten Anstiege der Körpertemperatur sowie laborchemischer Entzündungsparameter. Vom Anästhesieverfahren abhängige Unterschiede im Verlauf der Entzündungsreaktion waren nicht erkennbar. 13 von 18 Patienten zeigten passagere arterielle Desaturationen zwischen 83% und 95%. In 3 Fällen gingen Temperaturanstiege mit kardialen Komplikationen (Tachyarrhythmien, Stenokardie) einher. Perioperative Myokardinfarkte oder Todesfälle traten nicht auf. Zur endovaskulären Therapie ausgewählter Aortenaneurysmen sind neben der Allgemeinanästhesie auch die Regional- oder die Lokalanästhesie mit Analgosedierung praktikable, sichere Verfahren, sofern invasives Monitoring und engmaschige postoperative Überwachung gewährleistet sind. Die eingriffstypische abakterielle Entzündungsreaktion stellt für kardiopulmonal vorgeschädigte Patienten ein Risiko dar.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-055X
    Keywords: Schlüsselwörter ALV ; Rückgekoppelte Beatmung ; Beatmungsform ; Atmungsmechanik ; Künstliche Beatmung ; Beatmungsarbeit ; Nephrektomie ; Seitenlagerung ; Key words Adaptive lung ventilation ; Closed-loop control of ventilation ; Model of ventilation ; Pulmonary mechanics ; Artificial ventilation ; Work of breathing ; Nephrectomy ; Lateral decubitus position
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract The lateral decubitus position is the standard position for nephrectomies. There is a lack of data about the effects of this extreme position upon respiratory mechanics and gas exchange. In 20 patients undergoing surgery in the nephrectomy position, we compared a new closed-loop-controlled ventilation algorithm, adaptive lung ventilation (ALV), which adapts the breathing pattern automatically, to the respiratory mechanics with conventionally controlled mandatory ventilation (CMV). The aims of our study were (1) to describe positioning effects on respiratory mechanics and gas exchange, (2) to compary ventilatory parameters selected by the ALV controller with traditional settings of CMV, and (3) to assess the individual adaptation of the ventilatory parameters by the ALV controller. The respirator used was a modified Amadeus ventilator, which is controlled by an external computer and possesses an integrated lung function analyzer. In a first set of measurements, we compared parameters of respiratory mechanics and gas exchange in the horizontal supine position and 20 min after changing to the nephrectomy position. In a second set of measurements, patients were ventilated with ALV and CMV using a randomized crossover design. The CMV settings were a tidal volume of 10 ml/kg body weight, a respiratory rate of 10 breaths/min, an I:E ratio of 1:1.5, and an end-inspiratory pause of 30% of inspiratory time. With both ventilation modes FiO2 was set to 0.5 and PEEP to 3 cm H2O. During ALV a desired alveolar ventilation of 70 ml/kg KG·min was preset. All other ventilatory parameters were determined by the ALV controller according to the instantaneously measured respiratory parameters. Positioning induced a reduction of compliance from 61.6 to 47.9 ml/cm H2O; the respiratory time constant shortened from 1.2 to 1.08 s, whereas physiological dead space increased from 158.9 to 207.5 ml. On average, the ventilatory parameters selected by the ALV controller resembled very closely those used with CMV. However, an adaptation to individual respiratory mechanics was clearly evident with ALV. In conclusion, we found that the effects of positioning for nephrectomy are minor and may give rise to problems only in patients with restrictive lung disease. The novel ALV controller automatically selects ventilatory parameters that are clinically sound and are better adapted to the respiratory mechanics of ventilated patients than the standardized settings of CMV are.
    Notes: Zusammenfassung ALV stellt ein neues automatisches Beatmungsverfahren dar. Wir verglichen an 20 Patienten in Nephrektomielagerung ALV mit der konventionellen CMV-Beatmung. Ziele der Studie waren 1) Auswirkungen der Lagerung auf Atmungsmechanik und Gasaustausch festzustellen, 2) die vom ALV-Regler gewählten Beatmungsparameter mit den traditionell unter CMV eingestellten zu vergleichen und 3) die individuelle Anpassung der Beatmungsparameter unter ALV zu beurteilen. Zunächst wurden Atmungsmechanik- und Gasaustauschwerte in Rückenlage und 20 min nach Umlagerung verglichen. Danach wurden die Patienten nach einem randomisierten Crossover-Design sowohl ALV als auch CMV beatmet. Unter CMV wurde ein Atemzugvolumen von 10 ml/kg KG, eine Atmungsfrequenz von 10 AZ/min, ein I:E-Verhältnis von 1:1,5 und eine endinspiratorische Pause von 30% der Inspirationszeit eingestellt. Unter ALV wurde eine gewünschte alveoläre Ventilation von 70 ml/kg Körpergewicht und Minute vorgegeben. Nach Umlagerung nahm die Compliance von 61,6 auf 47,9 ml/cm H2O ab, die respiratorische Zeitkonstante verkürzte sich von 1,2 auf 1,08 s und der physiologische Totraum nahm von 158,9 auf 207,5 ml zu. Der ALV-Regler beatmete die Patienten mit Beatmungsparametern, die zwar im Mittel weitgehend identisch mit den unter CMV vorgegebenen waren, die aber eine individuelle Anpassung an die unterschiedliche Atmungsmechanik beobachten ließen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Herzanästhesie ; Herzchirurgie ; Qualitätssicherung ; Fremdblutverbrauch ; Eigenblutspende ; Key words Heart anesthesia ; Heart surgery ; Quality assurance ; donor blood ; Autotransfusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Allogeneic blood requirement in cardiac surgery shows a wide variation even for comparable procedures. The aim of the present study was to compare the intraoperative allogeneic blood requirement in defined cardiac operations among 12 cardiac centers in Germany. Method: A data set with 25 variables concerning the intraoperative course in adult cardiac patients with myocardial revascularization, valve replacement (aortic or/and mitral valve) or combined procedures was distributed to the participating centers. The data of all patients between January 1th 1998 and June 30th 1998 were included. Besides demographic data, the intraoperative transfusion of allogeneic and autologous blood, fresh frozen plasma and the concomitant hematocrit values were registered. Data were analyzed for all centers and separated for each center. Results: The data of 7.729 patients were analyzed. The intraoperative allogeneic blood requirement was 0.6±1.3 units for all patients. It varied among the centers from 0.25±0.6 units to 0.97±1.6 units (P〈0.05). The percentage of patients receiving allogeneic blood was 27% and differed among the centers from 17% to 35%. Female patients were transfused in 53% (36–39%) compared to male patients with 16% (9–20%) (P〈0.05). The rate of autologous blood predonation varied from 0.5% to 23%. Patients without autologous predonation were transfused in 28% compared to 4% in patients with predonation (P〈0.05). In patients with autologous predonation the intraoperative transfusion of allogeneic blood was significantly reduced (0.1±0.39 vs 0.6±1.4 units, P〈0.05). However, some centers with a high percentage of autologous predonation also demonstrated a high rate of perioperative allogeneic transfusion. Conclusion: The incidence of allogeneic blood transfusion in cardiac surgery depends on the institution and not on the surgical procedure. A common threshold value of hemoglobin for the transfusion of blood trigger even for comparable procedures could not be detected among the centers. Especially in female patients, there was a wide variation in allogeneic blood transfusion. Autologous blood predonation reduces blood requirement significantly, however, it is practiced with variing intensity. The data set did not include information about transfusion regimen in the postoperative period, thus, these data do not allow to draw conclusions for the whole perioperative period.
    Notes: Zusammenfassung Fragestellung: Der Blutverbrauch in der Herzchirurgie zeigt auch bei vergleichbaren Eingriffen eine weite Variationsbreite. Die vorliegende Studie untersucht den intraoperativen Fremdblutverbrauch und die Eigenblutspende bei definierten herzchirurgischen Eingriffen an 12 herzchirurgischen Kliniken. Methodik: Mit Hilfe eines vorgegebenen Datensatzes wurden 25 Variablen zum intraoperativen Verlauf bei erwachsenen Patienten mit den Operationen Myokardrevaskularisation, Klappenersatz (Aorten- oder/und Mitralklappenersatz) oder Kombinationseingriffen erfaßt. Die Datenerfassung schloß alle Patienten mit den vorgebenen Diagnosen vom 1.1. bis 30.6.1998 ein. Neben den demographischen Daten wurde der intraoperative Verbrauch von homologen und autologen Erythrozytenkonzentraten, sowie die prä- und intraoperative Hämoglobinkonzentration aufgenommen. Die Auswertung wurde für alle Zentren und nach Zentren getrennt durchgeführt. Ergebnisse: Die Daten von 7729 Patienten wurden erfaßt. Der intraoperative Fremdblutverbrauch für alle Operationen betrug im Mittel 0,6±1,3 Einheiten und variierte zwischen den Kliniken von 0,25±0,6 Einheiten bis 0,97±1,6 Einheiten (p〈0,05). Der Anteil der Patienten, die intraoperativ Fremdblut erhielten betrug 27% und bewegte sich zwischen 17% und 35%, bei weiblichen Patienten betrug der Anteil 53% (36–69%) im Vergleich zu männlichen Patienten mit 16% (9–20%) (p〈0,05). Der Prozentsatz von Patienten mit Eigenblutspende lag zwischen 0,5% und 23%. Intraoperativ erhielten 4% der Eigenblutpatienten zusätzlich Fremdblut, während 28% der restlichen Patienten Fremdblut transfundiert wurde (p〈0,05). Zwar zeigten die Eigenblutpatienten insgesamt einen signifikant geringeren Fremdblutverbrauch (0,1±0,39 vs 0,6±1,4 Einheiten, p〈0,05), doch war dieser Effekt innerhalb der einzelnen Zentren ausgeprägter: auch Zentren mit einem hohen Eigenblutanteil zeigten nicht unbedingt den geringsten Fremdblutverbrauch. Schlußfolgerungen: Die Inzidenz von intraoperativen Fremdblutgaben in der Herzchirurgie ist in erster Linie vom Zentrum und nicht von der zugrundeliegenden Erkrankung abhängig. In der klinischen Routine ist im Vergleich verschiedener Herzzentren kein einheitlicher Hämoglobinschwellenwert für die Transfusion auszumachen. Insbesondere bei weiblichen Patienten fand sich eine große Variationsbreite der intraoperativen Transfusionshäufigkeit. Die präoperative Eigenblutspende reduziert den intraoperativen Fremdblutverbrauch, wird aber mit unterschiedlicher Häufigkeit eingesetzt. Rückschlüsse auf den gesamten perioperativen Verlauf sind aufgrund vorliegender Daten nicht statthaft.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Hyperglykämie ; Hypoglykämie ; regionale Organdurchblutung ; Microspheres ; kardiopulmonale Reanimation (CPR) ; Key words Hyperglycaemia ; Hypoglycaemia ; Regional organ blood flow ; Microspheres ; Cardiopulmonary resuscitation (CPR)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Blood glucose alterations prior to cerebral ischaemia are associated with poor neurologic outcome, possibly due to extensive lactic acidosis or energy failure. Cerebral effects of hyper- or hypoglycaemia during cardiopulmonary resuscitation (CPR) are less well known. In addition, little information is available concerning cardiac effects of blood glucose alterations. The aim of this study was to evaluate the effects of pre-cardiac-arrest hypo- or hyperglycaemia compared to normoglycaemia upon haemodynamics, cerebral blood flow (CBF) and metabolism (CMRO2), and regional cardiac blood flow during CPR subsequent to 3 min of cardiac and respiratory arrest and after restoration of spontaneous circulation. Methods. After approval by the State Animal Investigation Committee, 29 mechanically ventilated, anaesthetised pigs were instrumented for haemodynamic monitoring and blood flow determination by the radiolabeled microsphere technique. The animals were randomly assigned to one of three groups: in group I (n=9) blood glucose was not manipulated; in group II (n=10) blood glucose was increased by slow infusion of 40% glucose to 319±13 mg/dl; in group III (n=10) blood glucose was lowered by careful titration with insulin to 34±2 mg/dl. After 3 min of untreated ventricular fibrillation and respiratory arrest, CPR (chest compressor/ventilator (Thumper®) and epinephrine infusion) was commenced and continued for 8 min. Thereafter, defibrillation was attempted, and if successful, the animals were observed for another 240 min. Cerebral perfusion pressure (CPP), CBF, CMRO2, coronary perfusion pressure (CorPP), and regional cardiac blood flow were determined at control, after 3 min of CPR, and at 10, 30, and 240 min post-CPR. Results. In group I, 4/9 animals (44%) could be successfully resuscitated; in group II 4/10 (40%); and in group III 0/10 (0%). Prior to cardiac arrest, mean arterial pressure, CPP, and CorPP in group III were significantly lower compared to groups I and II. In group I, CPP during CPR was 26±6 mmHg; CBF 31±9 ml/min/100 g CMRO2 3.8±1.2 ml/min/100 g; CorPP 18±5 mmHg; and left ventricular (LV) flow 35±15 ml/min/100 g. In group II: CPP=21±5; CBF 21±7; CMRO2 1.8±0.8; CorPP 16±6; and LV flow 22±9; and in group III: CPP 15±3; CBF 11±8; CMRO2 1.5±1.1; CorPP 4±2; and LV flow 19±10. During the 240-min post-resuscitation period, there were no differences in CBF, CMRO2, or LV flow between groups I and II. Conclusion. Hypoglycaemia prior to cardiac arrest appears to be predictive for a poor cardiac outcome, whereas hyperglycaemia does not impair resuscitability compared to normoglycaemia. In addition, hyperglycaemia did not affect LV flow, CBF, or CMRO2. However, it has to be kept in mind that haemodynamics and organ blood flow do not permit conclusions with respect to functional neurologic recovery or histopathologic damage to the brain, which is very likely to be associated with hyperglycaemia.
    Notes: Zusammenfassung Gegenstand der vorliegenden Untersuchung im Schweinemodell ist der Einfluß einer prä-ischämischen Normo-, Hyper- oder Hypoglykämie auf Hämodynamik, regionale Organdurchblutung und Reanimierbarkeit nach 3minüti-gem unbehandelten Herz-Kreislauf-Stillstand und anschließender kardiopulmonalen Reanimation (CPR). Hypoglykämie (Blutzuckerkonzentration von 34±2 mg/dl) war bereits vor der Reanimation mit einer deutlichen Beeinträchtigung hämodynamischer Parameter assoziiert. Keines der hypoglykämischen Tiere konnte erfolgreich reanimiert werden, im Gegensatz zu den hyper- (Blutzucker 319±13 mg/dl) bzw. normoglykämischen Tieren, die keinen Unterschied hinsichtlich der Erfolgsrate der Reanimation aufwiesen. Weder vor noch während oder nach Reanimation unterschieden sich hyper- und normoglykämische Tiere in bezug auf Hämodynamik oder regionale kardiale oder zerebrale Durchblutung. Somit bleibt festzuhalten, daß Hypoglykämie bei CPR mit einer schlechten kardialen Prognose assoziiert ist, während Hyperglykämie die kardiale Reanimation offenbar nicht beeinträchtigt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Lokalanästhetika: Bupivacain ; Toxizität: Lokalanästhetika ; Key words Anaesthetics ; local ; Bupivacaine ; Cerebroventricular perfusion ; Toxicity: local anaesthetics ; CNS effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Objectives: The cardiotoxic properties of bupivacain have been well documented under in-vitro, as well as under in-vivio conditions. A further mechanism of cardiovascular impairment by bupivacaine via the central nervous system gained investigational interest in animal studies. The aim of our study was to demonstrate the effect of a ventriculocisternal perfusion of bupivacain on systemic hemodynamic variabels and their reversability by wash-out with mock-CSF. Methods: After obtaining animal investional commitee consent, nine anaesthetized and relaxated pigs were prepared for a ventriculocisternal perfusion (VCP). Hemodynamic data were obtained by invasive blood pressure measurements in the high and low pressure system as well as cardiac output (thermodilution technique), intracranial pressure and electrocardiogram. Systemic vascular resistance and stroke volume were calculated using standard formulas. A second group of three animals were exposed to an intravenous infusion of the same dose of bupivacain over the same period of time to rule out direct cardiac effects. After instrumentation baseline data were obtained (KO 1) under VCP with mock-CSF for 30 minutes. The mock-CSF was replaced by 0,05% bupivacaine in mock-CSF and VCP was continued with 3 ml · h–1 for 20 minutes. After adminstration of 500 µg bupivacaine data were collected (BU). The bupivacaine solution was replaced by mock-CSF and after twenty minutes hemodynamic measurement were repeated (KO2). Results: The intravenous adminstration of 500µg bupivacaine had no effect on all measured variables. VCP of the same dose resulted in significant increase in heart rate, systolic, diastolic and mean arterial blood pressures. Left and right heart filling pressures as well as systemic vascular resistance were not affected while the stroke volume decreased. After continuation of VCP with mock-CSF hemodynamic changes were reversed. Discussion: Our results demonstrate that bupivacaine initiates an indirect cardiovascular stimulating effect of a VCP with 500 µg of bupivacaine via the central nervous system. The intravenous administration of the same dose had no effect. The centrally mediated cardiovascular effect of bupivacaine was reversed by wash-out with mock-CSF. The cardiovascular stimulation observed in this animal experiment may be of clinical relevance as a potential sign of toxic effects of bupivacaine on the CNS.
    Notes: Zusammenfassung Die in vitro nachweisbaren kardiotoxischen Eigenschaften des Bupivacains sind weitgehend bekannt, eine weitere, über das Zentralnervensystem vermittelte Beeinflussung des Herzkreislaufsystems wird dagegen diskutiert. Ziel dieser Studie war es, die Auswirkungen der zentral vemittelten Bupivacainwirkung auf systemische Kreislaufparameter und deren Reversibilität durch Auswaschung mit künstlichem Liquor (m-CSF) tierexperimentell zu untersuchen. Methodik: Dazu wurden nach Genehmigung durch die Tierschutzkommission 9 anästhesierte Jungschweine für eine ventrikulozisternale Perfusion (VCP) mit insgesamt 500 µg Bupivacain in m-CSF präpariert. Die Messungen umfaßten neben invasiv registrierten Blutdrücken im kleinen und großen Kreislauf Herzzeitvolumen, intrakraniellen Druck und Elektrokardiogramm. Der periphere Widerstand und das Schlagvolumen wurden berechnet. Zusätzlich wurde drei Tieren einer Kontrollgruppe Bupivacain 500 µg zum Ausschluß einer direkt kardialen Wirkung intravenös appliziert. Nach einer Stabilisierungsphase im Anschluß an die Präparation wurden Ausgangswerte unter einer VCP mit m-CSF erhoben (KO 1). Danach wurde die VCP über 20 min mit Bupivacain in m-CSF fortgeführt und eine weitere Messung angeschlossen (BU). Die dritte Messung erfolgte nach VCP nur mit m-CSF über 20 min (KO 2). Ergebnisse: Die ventrikulo-zisternale Perfusion von 500 µg Bupivacain führte zu einem Anstieg des systolischen, diastolischen und mittleren arteriellen Bludrucks, der Herzfrequenz und des Herzzeitvolumens. Die rechts- und linksventrikulären Füllungsdrücke sowie der periphere Widerstand blieben unbeeinflußt. Das Schlagvolumen nahm signifikant ab. Mit der Auswaschung (KO 2) waren alle Kreislaufeffekte vollständig reversibel. Bei der intravenösen Infusion der gleichen Bupivacainmenge traten keine Änderungen in den gemessenen Variablen auf. Schlußfolgerungen: Nach unseren Ergebnissen führte die VCP mit 500 µg Bupivacain im Gegensatz zur intravenösen Infusion zu einer signifikanten, zentral vermittelten Kreislaufstimulation, die unter Fortführung der VCP mit m-CSF durch eine Verdünnung oder Auswaschung innerhalb von 20 min vollständig reversibel ist. Den beobachteten Kreislaufeffekten könnte für die frühzeitige Erkennung einer unerwünschten Reaktion auf Bupivacain für die klinische Routine Bedeutung zukommen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Der Anaesthesist 46 (1997), S. 574-582 
    ISSN: 1432-055X
    Keywords: Sclüsselwörter Automatisches Anästhesieprotokoll ; Expertensysteme ; Wissenbasierte Systeme ; Datenbankstrukturen ; Qualitätssysteme ; EDV-Applikationen ; Key words Anaesthesia record systems,artificial intelligence, data base structures, computer application, man-machine interfacing, quality control
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract The introduction of electronic anaesthesia documentation systems was attempted as early as in 1979, although their efficient application has become reality only in the past few years. The advantages of the electronic protocol are apparent: · Continuous high quality documentation, · comparability of data due to the availability of a data bank, · reduction in the workload of the anaesthesist and · availability of additional data. Disadvantages of the electronic protocol have also been discussed in the literature. By going through the process of entering data on the course of the anaesthetic procedure on the protocol sheet, the information is mentally absorbed and evaluated by the anaesthesist. This information may, however, be lost when the data are recorded fully automatically – without active involvement on the part od the anaesthesist. Recent publications state that by using intelligent alarms and/or integrated displays manual record keeping is no longer necessary for anaesthesia vigilance. The technical design of automated anaesthesia records depends on an integration of network technology into the hospital. It will be appropriate to connect the systems to the Internet, but safety requirements have to be followed strictly. Concerning the database, client server architecture as well as language standards like SQL should be used. Object oriented databases will be available in the near future. Another future goal of automated anaesthesia record systems will be using knowledge based technologies within these systems. Drug interactions, disease related anaesthetic techniques and other information sources can be integrated. At this time, almost none of the commercially available systems has matured to a point where their purchase can be recommended without reservation. There is still a lack of standards for the subsequent exchange of data and a solution to a number of ergonomic problems still remains to be found. Nevertheless, electronic anaesthesia protocols will be required in the near future. The advantages of accurate documentation and quality control in the presence of careful planning outweigh cost considerations by far.
    Notes: Zusammenfassung Die Einführung automatischer Anästhesieprotokollsysteme wurde bereits 1979 versucht, wobei ein effizienter Einsatz erst in den letzten Jahren zur Realität wurde. Vorteile. Die Vorteile eines elektronischen Protokollsystems sind die kontinuierliche Dokumentation mit hoher Qualität, die Vergleichbarkeit der Daten aufgrund der Verfügbarkeit in einer Datenbank, die Verminderung des Arbeitsaufwandes f¨r den Anästhesisten und die Verfügbarkeit zusätzlicher Informationen. Nachteile. Durch das handschriftiliche Führen eines Anästhesieprotokolls findet eine Bewußtmachung des anästhesieologischen Verlaufs statt. Werden die Daten jedoch automatisch registriert, könnte die mentale Verarbeitung der Daten durch den Anästhesisten verloren gehen. Neue Publikationen zeigten jedoch, daß durch die Verwendung von “intelligenten” Alarmsystemen und Verbesserungen der grafischen Datenpräsentation die manuelle Datenaufzeichnung im Hinblick auf die Aufmerksamkeit des Anästhesisten nicht erforderlich ist. Technische Anforderungen. Das technische Design automatischer Anästhesieprotokollsysteme hängt von der Netzwerktechnologie des jeweiligen Krankenhauses ab. Unter Einhaltung entsprechender Sicherheitsmaßnahmen ist eine Verbindung zum Internet sinnvoll. Die Datenverwaltung sollte nach dem sog. Client Server Prinzip erfolgen. Standard in Bezug auf die Programmiersprache ist die sog. SQL (structured query language). In der nahen Zukunft werden aber auch “objektorientierte” Datenbanken mit noch größerer Flexibilität vorhanden sein. Ausblick. Derzeit kann der Kauf von keinem der kommerziell verfügbaren Systeme ohne Einschränkungen empfohlen werden. Es fehlen allgemeningültige Standards für den späteren Datentransfer und die Kosten-Nutzen Frage ist noch nicht gelöst. Die Vorteile der Dokumentation mit hoher Datenqualität und die bessere Information über den Zeit- und Resourcenverbrauch werden jedoch in den nächsten Jahren zu einer Einführung automatischer Anästhesieprotokollsysteme führen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1432-1238
    Keywords: Key words High-frequency oscillatory ventilation ; HFOV ; Mechanical ventilation ; Adults ; Pneumonectomy ; Postoperative period ; Pneumonia ; ARDS ; Oxygenation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract High frequency oscillatory ventilation (HFOV) was used in a patient who developed the acute respiratory distress syndrome 5 days following a right pneumonectomy for bronchogenic carcinoma. When conventional pressure-controlled ventilation failed to maintain adequate oxygenation, HFOV dramatically improved oxygenation within the first few hours of therapy. Pulmonary function and gas exchange recovered during a 10-day period of HFOV. No negative side effects were observed. Early use of HFOV may be a beneficial ventilation strategy for adults with acute pulmonary failure, even in the postoperative period after lung resection.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 25 (1999), S. 761-762 
    ISSN: 1432-1238
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Chemical Physics 92 (1985), S. 417-422 
    ISSN: 0301-0104
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Chemical Physics 80 (1983), S. 279-288 
    ISSN: 0301-0104
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...