Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Der Anaesthesist 44 (1995), S. 436-441 
    ISSN: 1432-055X
    Keywords: Schlüsselwörter: Spülflüssigkeit — Transurethrale Prostataresektion — Alkohol — TUR-Syndrom — Einschwemmung ; Key words: Irrigation — Prostatectomy — Ethanol — Fluid absorption
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract. The absorption of large volumes of irrigation fluid is a major problem in transurethral prostatic surgery (TUR-P). Various indicators have been tested to monitor fluid absorption with regard to continuous registration and sufficient accuracy. The volumetric fluid balance is not suitable as a routine method because of its inaccuracy. Easily accessible parameters are unspecific because of surgical bleeding (haematocrit [Hct]), or are interfered with by physiological counter-regulatory actions (serum sodium [Na] concentration). In 1986 Hulten et al. suggested adding 2% ethanol to the irrigation fluid as a marker and investigated it intermittently in the expired air with an alcohol-test appliance. In a prospective clinical study of 17 patients undergoing TUR-P under spinal anaesthesia, expiratory concentrations of alcohol that was added to the irrigation fluid (2% ethanol in Purisole, Fresenius, Bad Homburg) were monitored. Gas was continuously sampled from the nasopharynx through a nasal cannula and the ethanol concentration was measured using a modified diverting anaesthetic gas monitor (Normac, Datex, Helsinki) that allows continuous as well as early detection of the absorbed irrigation fluid with reliable accuracy for clinical use. In addition, at intervals of 10 minutes we measured blood alcohol, endtidal alcohol (Alcotest 7110, Drauml;ger, Lübeck), haematocrit, serum Na concentration, and blood gases. Sixty-eight measurements were obtained from the 17 patients. As shown in other studies, serum Na (r2 = 0.68) and Hct (r2 = 0.39) correlated poorly with the irrigation fluid as determined by serum alcohol levels. In contrast, the expiratory alcohol measurements with the alcotest 7110 (r2 = 0.93) and Normac devices (r2 = 0.85) were closely related. Continuous monitoring of the expiratory alcohol concentration with a Normac monitor closely reflects blood alcohol concentrations, and may hence serve as a useful semiquantitative monitor of irrigation fluid absorption during TUR-P.
    Notes: Zusammenfassung. Die Einschwemmung großer Volumina von Spülflüssigkeit stellt bei der transurethralen Prostataresektion das Hauptproblem dar. Bisher verwendete Methoden weisen die Einschwemmung unzureichend nach. Erstmals setzten Hulten et al. der Spülflüssigkeit 2%igen Alkohol zu und wiesen diesen exspiratorisch diskontinuierlich mittels eines Alkoholtestgeräts nach. In dieser Studie entnahmen wir 17 Patienten unter Spinalanästhesie über eine Nasensonde kontinuierlich Exspirationsluft aus dem oberen Nasen-Rachen-Raum, die wir mittels eines NormacTM-Anästhesiegasmonitors (Fa. Datex, Helsinki) auf Alkohol untersuchten. Es sollte festgestellt werden, ob diese Methode mit klinisch ausreichender Genauigkeit eine Einschwemmung des Alkohols, der der Spülflüssigkeit zugemischt wird, aufzeigen kann. Dazu wurden neben der kontinuierlichen exspiratorischen Alkoholmessung folgende Meßwerte erhoben: Blutalkoholspiegel, endexspiratorischer Alkohol mittels Alcotest 7110, Hämatokrit, Serumnatrium und Blutgasanalyse. Bei 17 Patienten wurden 68 Messungen durchgeführt (je ein Leerwert, in 10minütigem Abstand). Erwartungsgemäß korrelierten das Serum-Natrium (r2 = 0,68) und der Hämatokrit (r2 = 0,39) schlecht mit der durch Blutalkoholbestimmung ermittelten Einschwemmung. Die Ergebnisse der exspiratorischen Alkoholbestimmung mit dem Alcotest-Gerät (r2 - 0,93) und die kontinuierliche Messung mit dem Normac (r2 = 0,85) ergaben gute Übereinstimmungen mit den Blutalkoholkontrollen. Im klinisch interessanten Bereich ab 0,3‰ Blutalkoholspiegel (entsprechend 500 bis 1000 ml Einschwemmvolumen) erreicht das kontinuierliche Monitoring der exspiratorischen Alkoholkonzentration mit einem NormacTM eine ausreichende Genauigkeit und liefert früzeitig einen zuverlässigen Hinweis für eine Einschwemmung.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Key words High-frequency oscillatory ventilation ; HFOV ; Mechanical ventilation ; Adults ; Pneumonectomy ; Postoperative period ; Pneumonia ; ARDS ; Oxygenation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract High frequency oscillatory ventilation (HFOV) was used in a patient who developed the acute respiratory distress syndrome 5 days following a right pneumonectomy for bronchogenic carcinoma. When conventional pressure-controlled ventilation failed to maintain adequate oxygenation, HFOV dramatically improved oxygenation within the first few hours of therapy. Pulmonary function and gas exchange recovered during a 10-day period of HFOV. No negative side effects were observed. Early use of HFOV may be a beneficial ventilation strategy for adults with acute pulmonary failure, even in the postoperative period after lung resection.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 43 (1992), S. 445-447 
    ISSN: 1432-1041
    Keywords: Captopril ; Digitoxin ; impedance cardiography ; drug interaction ; healthy volunteers ; pharmacodynamics ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The chronic oral administration of 0.07 mg digitoxin o. d. for up to 58 days to 12 healthy volunteers caused a small drop in mean heart rate HR (95 % CI: −7.9 to −1.6 beats · min−1), in mean diastolic blood pressure (95 % CI: −8.3 to −0.4 mm Hg), shortening of the QTc-interval (95 % CI: −42 to −19 ms), shortening of the HR-corrected pre-ejection period PEPc (95 % CI: −16 to −1 ms) and electromechanical systole QS2c (95 % CI: −25 to −1 ms), and an increase in the impedance cardiographic Heather index (dZ/dtmax/RZ, 95 % CI: 0.3 to 4.3) relative to the baseline measurements before digitalisation. The concomitant administration of 25 mg oral captopril b. d. did not significantly alter these responses relative to the concomitant double-blind administration of placebo, nor did it alter the pharmacokinetic characteristics of plasma digitoxin at steady state. Thus, no relevant change in the pharmacokinetic and pharmacodynamic characteristics of chronically administered digitoxin were induced by concomitant treatment with captopril.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Intensivmedizin und Notfallmedizin 34 (1997), S. 432-441 
    ISSN: 1435-1420
    Keywords: Key words Emergency medical services ; cardiopulmonary resuscitation ; early defibrillation ; bystander CPR ; system analysis ; quality management ; Schlüsselwörter Rettungsdienst ; Rettungssystem ; kardiopulmonale Reanimation ; Frühdefibrillation ; Laienreanimation ; Qualitätsmanagement
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Ziel dieser Untersuchung war es zu klären, ob die Struktur des Mainzer Rettungssystems eine flächendeckende und fristgerechte Versorgung von Notfallpatienten gewährleistet. Darüber hinaus wurde der Einfluß infrastruktureller Faktoren des Stadtgebietes sowie der Reanimation durch Ersthelfer auf Struktur- und Ergebnisqualität untersucht. Das zu untersuchende System versorgt 190 000 Einwohner auf einer Fläche von 80 km2 mit Hilfe von 4 Rettungs- (RTW) und 1 Notarztwagen (NAW), die in einem gestaffelten System mit den Möglichkeiten eines Frühdefibrillationsprogramms für Rettungsassistenten eingesetzt werden. Im Zeitraum von 1.2.92 bis zum 1.7.93 wurden prospektiv 171 Patienten mit nicht traumatisch verursachten Herzkreislaufstillstand (HKS) in die Untersuchung aufgenommen. 24 dieser Patienten konnten nach Hause entlassen werden (14%), für Patienten mit der EKG-Diagnose ,,Kammerflimmern`` (n = 69) betrug die Entlassungsrate 28% (n = 19), was im internationalen Vergleich ein gut funktionierendes Rettungssystem indiziert. Die Fahrzeiten vom Eingang des Notrufs bis zur Ankunft vor Ort betrugen fünf Minuten für die RTW und acht für die NAW. Das sich daran anschließende Intervall vom Verlassen des Fahrzeugs bis zum Erreichen des Patienten betrug für beide Fahrzeuge 0,83 min. Diese kurze Intervall ist ein Indiz für das Fehlen von Hindernissen am Notfallort und die für Rettungsmannschaften günstige Infrastruktur der Stadt. Das homogene Stadtbild sichert einen schnellen Zugriff auf Notfallpatienten. Trotz der im Median kurzen Anfahrzeiten konnten für einzelne Stadtteile in der Stadtperipherie erhebliche Verzögerungen nachgewiesen werden. Dies stellt insbesondere ein Problem dar, wenn – wie bei immerhin 30% der Einsätze – dem NAW nicht der nächstgelegene RTW vorausgeschickt wird. Differenziert nach den äußeren Umständen des HKS zeigte sich ein signifikant kürzeres Zeitintervall ,,vor Ort – am Patienten`` für Patienen, welche auf offener Straße kollabierten, verglichen mit Patienten in geschlossenen Gebäuden. Dies spiegelt sich auch in der signifikant höheren Überlebenszeit dieser Patientengruppe wider. Als problematisch stellt sich die geringe Bereitschaft der Bevölkerung zur Ersten Hilfe dar. Drei Viertel der HKS wurden beobachtet; Erste Hilfe wurde jedoch in lediglich einem Viertel der Fälle geleistet, rund die Hälfte davon wiederum von Angehörigen eines medizinischen Berufs. Somit liegt die Laienreanimationsrate bei 13%. Insgesamt stellt das Mainzer Rettungssystem die flächendeckende fristgerechte Versorgung der Bevölkerung sicher. Durch folgende Veränderungen könnten Schwachstellen ausgeglichen und die Effektivität des Systems gesteigert werden: 1. Konsequente Umsetzung des gestaffelten Systems, u.U. unter Einbeziehung der KTW. 2. Umlegung einer Rettungswache in die Nähe des Autobahnrings in Sektor 4 oder 5. 3. Ausbildung und Einbeziehung von ,,First Respondern``, z.B. aus den Reihen der Feuerwehr. 4. Gezielte Information der Bevölkerung über die Rufnummer der Rettungsleitstelle. 5. Identifzierung und gezielte Schulung von Risikopatienten und deren Angehörige.
    Notes: Summary The objective of this study was to investigate whether the structure of the Mainz Emergency Medical Services (EMS) system warrants an adequate care of emergency patients a) within a certain time-frame, b) in any part of the city. We analyzed the influence of the city's infrastructural factors as well as bystander resuscitation upon structure and outcome elements of quality. The EMS system investigated serves a population of 190 000 in an 80 km2 area with four emergency ambulances manned with EMT-Ds and 1 physician-staffed Mobile Intensive Care Unit (MICU) in a two-tiered system. From February 1992 until July 1993 we prospectively collected data from 171 out-of-hospital cardiac arrests of non-traumatic etiology. Twenty-four of the patients were discharged from hospital (14%). Patients with ventricular fibrillation as first ECG-diagnosis had a 28% discharge rate (19 of 69). The time interval from call reception at the dispatch center until arrival of the emergency ambulance at the scene was 5 min, and 8 min for the MICU, respectively, which indicates a proper deployment of the vehicles. Both teams then took 0.83 min to reach the patient after leaving their vehicles, which indicates a suitable city structure for a swift patient access. Although short in median, single time intervals in peripheral parts of the city were delayed. This turned out to be a problem in cases when the MICU was not preceded by an emergency ambulance as first tier, which happened in 30% of the cases. Rescue teams had a significantly shorter access to patients collapsing in a public place as compared to patients collapsing at home (0.5 vs. 1 min, p = 0.01). Survival rates were also significantly higher in the first group (29 vs. 11%, p = 0.039). With a rate of 25% bystander resuscitation turned out to be a problem. Half of these bystanders were medical professionals, leaving a layperson resuscitation rate of 13%. With the following system changes the problems identified in our investigation could be solved, and the overall effectiveness of the system could be improved: 1) Consistent dispatch of the vehicles in a two-tiered manner. In cases when no emergency ambulance is available, basic ambulances should be dispatched as first tier. 2) Training and dispatch of ``first responders'' in peripheral parts of the city. 3) Recurrent information of the population concerning emergency telephone numbers. 4) Identification of risk patients and training of their spouses in resusci-tation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...