Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of the European Academy of Dermatology and Venereology 16 (2002), S. 0 
    ISSN: 1468-3083
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We present a case of a primary malignant fibrous histiocytoma of the skin (MFH) arising on chronic osteomyelitis in a 67-year-old woman. Although this condition seems to be a predisposing factor for the onset of the malignancy, MFH complicating chronic osteomyelitis is generally localized at the level of the bone tissue. In the case we report the neoplasm was primitively localized at the dermal and subcutaneous level and presented as a rapidly growing mass.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of the European Academy of Dermatology and Venereology 15 (2001), S. 0 
    ISSN: 1468-3083
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We describe the case of a 45-year-old man with atopy who developed marked inflammatory lesions on the bearded area of the face caused by Tricophyton rubrum, an anthropophilic fungus not frequently correlated with kerion of the face. After starting therapy with griseofulvin, he developed typical lesions of erythema nodosum on both legs. We discuss how these lesions could be correlated with the kerion of the face.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of the European Academy of Dermatology and Venereology 19 (2005), S. 0 
    ISSN: 1468-3083
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background  The 1- and the 2-euro coins consist of nickel alloys, which release nickel. The nickel released by far exceeds the amount allowed by the European Union Nickel Directive referring to products intended to come into direct and prolonged contact with the skin. As there is only temporary contact with the skin, the clinical relevance of nickel-containing coins with regard to nickel dermatitis is a matter of debate, although there is evidence that the nickel released from the coins affects some nickel-sensitive subjects through occupational exposure.Objectives  Our aim was to study skin reactivity to euro coins, and to correlate the frequency and intensity of coin patch test responses to sensitization thresholds to nickel.Patients and methods  Sixty-four nickel-sensitized and 30 non-nickel-sensitized subjects were patch tested with serial dilutions of nickel sulfate (5, 1, 0.5, 0.1, 0.05, 0.01 and 0.005% in distilled water) and with coins. Italian coins (500, 200, 100 and 50 lira) and euro coins (2 and 1 euros, 20 and 5 euro cents) were used for patch testing and compared.Results  The application of 1- and 2-euro coins to the skin induced eczematous reactions, being more frequent and intense in comparison with those provoked by other coins. A correlation between intensity of responses to coin patch tests and sensitization threshold to nickel was observed. Patients with the strongest reactions to 1- and 2-euro coins showed positive responses to the lowest nickel concentrations.Conclusions  The nickel content in euro coins represents a possible health hazard, especially for highly nickel-sensitive subjects. We recommend that nickel sulfate patch tests should be performed at different concentrations to determine sensitization thresholds at least in individuals with occupational exposure to coins.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Contact dermatitis 47 (2002), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Clinical and experimental dermatology 29 (2004), S. 0 
    ISSN: 1365-2230
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Clinical and experimental dermatology 29 (2004), S. 0 
    ISSN: 1365-2230
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0039-9140
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1365-2133
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background  Reactions to systemically administered corticosteroids are rare, despite their widespread use.Objectives  To identify alternative glucocorticoids for emergency use in patients with adverse reactions to systemic glucocorticoids.Methods  Ten patients were identified as having adverse reactions after the use of systemic corticosteroids. Skin prick tests and intradermal tests to hydrocortisone (HC) and methylprednisolone (MP), and intradermal tests to betamethasone and dexamethasone, were performed in all patients, and oral challenge tests to betamethasone (n=10) and deflazacort (n=6).Results  Skin prick tests were negative in all patients, whereas intradermal tests to HC and MP were positive in eight; two patients showed only an isolated cutaneous sensitivity to MP. Intradermal tests to betamethasone and dexamethasone were negative, and oral challenge tests were negative in all patients.Conclusions  Our results suggest the possibility of an IgE-mediated mechanism for allergic reactions to HC and MP, probably due, at least in part, to a steroid-glyoxal. We suggest that betamethasone and deflazacort could be reserved for emergency use in patients with adverse reactions to other corticosteroids.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    European journal of epidemiology 7 (1991), S. 699-701 
    ISSN: 1573-7284
    Keywords: Neisseria meningitidis ; Acute urethritis ; Oro-genital contact
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Isolation of N. meningitidis from the male urethra has become more common in recent years and this has been attributed to sexual activities and changes in social attitudes. We describe a further case of acute urethritis caused by transmission of N. meningitidis occurring after a single sexual contact (fellatio) in a heterosexual man. The urethritis was initially diagnosed as being caused by N. gonorrhoeae on a presumptive basis, then attributed to N. meningitidis serogroup Y. This case shows the need of accurate diagnostic procedures in all cases resembling gonococcal urethritis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 70 (1995), S. 379-386 
    ISSN: 1439-6327
    Keywords: Dynamic dynamometer ; Gravitational loads ; Force-velocity relationship ; Muscle power ; Muscle sex difference
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The validation of a new dynamometer for evaluation of dynamic muscle work is presented. The device was based on a precise measurement of load displacements of any machine using gravitational loads as external resistance. It allowed, through a sensor consisting of an infrared photo interrupter, the calculation of velocity, force and power during concentric, eccentric and stretch-shortening cycle activity. To validate the dynamometer 33 male and female track and field athletes (12 throwers and 21 jumpers) participated in the study. The throwers (4 women and 8 men) were asked to perform half-squat exercises on a slide machine with a load of 100% of the subject's body mass. The day-to-day reproducibility of half-squat exercises gave a correlation coefficient ofr = 0.88, 0.97 and 0.95 for average push-off force (AF), average push-off velocity (AV), and average push-off power (AP) respectively. Comparison of half-squat measurements was performed against jumping and running test evaluation by the jumpers (7 women and 14 men). The interrelationships among the different variables studied demonstrated a strong correlation between AF, AV and AP and sprinting and jumping parameters (r = 0.53−0.97;P 〈 0.05−0.001). Using values of AF, AV and AP developed in half-squat exercises executed with different loads, ranging from 35% to 210% of the subject's body mass, it was also possible to establish the force-velocity and power-velocity relationships for both male and female jumpers. In any individual case, the maximal error due to the measurement system was calculated to be less than 0.3%, 0.9% and 1.2% for AF, AV, and AP respectively. Given the accuracy of the ergometer, the high reliability found between 2 days of measurements, and the specificity of the results it is suggested that the dynamic dynamometer would be suitable for evaluation of athletes performing specific skills. In addition, because single and multiple joint movements involving appropriate muscle groups can be easily performed, physiological characteristics could be evaluated for both athletic and rehabilitation purposes. Therefore, because of its simplicity of use and application, and its low cost the dynamometer would be suitable for both laboratory and field conditions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...