Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Comparative Biochemistry and Physiology -- Part B: Biochemistry and 46 (1973), S. 15-18+IN1-IN2+19-35 
    ISSN: 0305-0491
    Keywords: Disc-electrophoresis ; ants ; haemolymph proteins ; larval development
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy Section 44 (1988), S. 1079-1086 
    ISSN: 0584-8539
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Electrochimica Acta 35 (1990), S. 769-770 
    ISSN: 0013-4686
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Applied Surface Science 62 (1992), S. 175-180 
    ISSN: 0169-4332
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    International Journal of Psychophysiology 12 (1992), S. 251-265 
    ISSN: 0167-8760
    Keywords: EMG ; Emotion ; Facial expression ; Facial feedback hypothesis ; HR ; Imagery ; SCL
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Medicine , Psychology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Supportive care in cancer 4 (1996), S. 320-321 
    ISSN: 1433-7339
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1433-0385
    Keywords: Key words: Thoracoabdominal aortic dissection ; Gastrointestinal ischemia ; Diagnosis ; Therapy. ; Schlüsselwörter: Thoracoabdominale Aortendissektion ; gastrointestinale Ischämie ; Diagnostik ; Therapie.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung. Die Fehlbeurteilung und unzureichende Wiederherstellung einer initialen oder nach primär alloplastischem Gefäßersatz persistierenden Organischämie bei der akuten thoracoabdominalen Aortendissektion stellt unverändert einen gravierenden Morbiditäts- und Letalitätsfaktor dar. Die abdominale Aortenfensterung stellt ein operatives Verfahren dar, das sich primär an dem morphologischen Substrat der Aortendissektion und der Auswirkung auf die arterielle Perfusion der Abdominalorgane orientiert. Vorgestellt werden 5 konsekutive Patienten (4 Männer, 1 Frau) mit akuter thoracoabdominaler Aortendissektion (2 Typ-A-, 3 Typ-B-Dissektionen) und assoziierter intestinaler, renaler, spinaler und peripherer Organischämie. Anhand einer primären oder sekundären abdominalen Aortenfensterung war es in allen Fällen möglich, ein Organversagen zu verhindern. Im postoperativen Langzeitverlauf sind alle Patienten nach 3 Jahren beschwerdefrei und rehabilitiert. Sekundärkomplikationen traten nicht auf. Wenn nach primärem prothetischen Aortenersatz bei akuter Typ-A- oder Typ-B-Dissektion eine durch arterielle Malperfusion verursachte abdominale Organischämie weiter besteht oder neu auftritt, sollte die abdominale Aortenfensterung sekundär ohne Zeitaufschub erfolgen. Bei akuten Typ-B-Dissektionen muß die Aortenfensterung als primäres Verfahren in Erwägung gezogen werden, wenn ein durch Ischämie bedingtes Organversagen zum prognostisch bestimmenden Faktor wird.
    Notes: Summary. Intestinal, renal, spinal or peripheral arterial ischemia or failure of branch artery recanalization following initial prosthetic repair of thoracoabdominal aortic dissection is still a problem, with high morbidity and mortality. Five consecutive patients with acute thoracoabdominal aortic dissection (two type A dissections, three type B dissections) suffering from concomitant intestinal, renal, spinal and acute peripheral arterial ischemia are reported. Considering the anatomical and pathophysiological basis of thoracoabdominal aortic dissection and concomitant organ ischemia, the aortic fenestration procedure as a primary or secondary operative approach succeeded in restoring blood flow in all cases without complications. Assessment of the long-term results after 3 years revealed that all patients are doing well without any residual complaints. We conclude that in the case of persistent or secondary onset of aortic branch artery ischemia following initial prosthetic repair of either type A or type B dissection, aortic fenestration can be recommended immediately as a staged operative approach. Primary abdominal aortic fenestration is justified in acute type B dissection when end-organ ischemia becomes the focus of clinical deterioration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 9 (1976), S. 373-379 
    ISSN: 1432-1041
    Keywords: Methyldigoxin ; repetitive doses ; bioavailability ; deep compartments ; oral and i.v. dose ; volunteers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary To obtain true half lives, glycoside elimination from six healthy subjects was studied for 14 days after multiple intravenous doses or oral administration of a daily maintenance dose of β-methyldigoxin 0.3 mg. After oral or intravenous administration of β-methyldigoxin ceased, the plasma concentrations declined from the 14th to the 16th days with a half life of 1.7 days. From the 16th to the 20th day a change from a shorter to a longer half life of 2.8 and 2.9 days was observed. Similar half lives were found in urine: after the last dose the initial slope from the 14th to the 16th day had a half life of 1.8 days, and the terminal slope had one of 3.2 days. The results indicate release of the glycoside from slowly equilibrating tissues.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Rechtsmedizin 10 (2000), S. 90-95 
    ISSN: 1434-5196
    Keywords: Schlüsselwörter Geschosse ; Verletzungen ; MRT ; Beurteilung ; Dokumentation ; Keywords Projectiles ; Injuries ; MRI ; Assessment ; Documentation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Description / Table of Contents: For the assessment of gunshot injuries, conventional X-ray examination, ultrasound and CT examinations are commonly used imaging techniques. With the exception of some authors, there is agreement that projectiles indicate a contraindication for MRI because of artificial imaging side-effects and the potential of secondary dislocation due to ferromagnetism. MRI testing was carried out on 56 projectiles for ferromagnetism and imaging quality in vitro and in pig carcasses with a 0.2 T and a 1.5T-MRI scanner. The image quality was compared to that of a CT scan. Projectiles with ferromagnetic properties can easily be distinguished from non-ferromagnetic ones by pretesting the motion of an projectile of the same type within the magnetic field of the MR scanner. When ferromagnetic projectiles were excluded, MRI yielded the more precise images compared to other imaging techniques. Projectile localization and associated soft tissue injuries were visualized without artifacts in all cases. When ferromagnetism is excluded MRI gives an excellent imaging procedure for the assessment and documentation of gunshot injuries. Therefore this imaging procedure may be also useful for medico-legal investigations.
    Notes: Zur Beurteilung des Ausmaßes von Schußverletzungen und zur Lokalisationsdiagnostik werden allgemein konventionelle Röntgenübersichtsaufnahmen sowie die Sonographie und die Computertomographie angewendet. Mit Ausnahme weniger Autoren wird generell davon ausgegangen, daß Projektile aufgrund der Generierung von Artefakten in der Bildgebung und der Gefahr einer sekundären Fremdkörperdislokation, bedingt durch den Ferromagnetismus, nicht mit der MRT beurteilt werden dürfen. 56 verschiedene Projektile wurden nach entsprechender Vortestung bezüglich ihrer Ferromagnetizität mit je einem 0,2-T- und 1,5-T-MRT-Gerät in vitro und anschließend in Schweinekadavern untersucht. Die Bildqualität wurde mit denen von CT-Bildern verglichen. Die ferromagnetischen Eigenschaften der Projektile können leicht beurteilt werden, indem man Vergleichsgeschosse desselben Typs in das Magnetfeld des MRT-Gerätes legt. Nach Ausschluß der Ferromagnetizität übertrifft die MRT alle anderen bildgebenden Verfahren. In allen Fällen gelang eine exakte Projektillokalisation sowie eine überlegene Darstellung der Weichteilverletzungen. Aufgrund der Ergebnisse ist die MRT, nach Ausschluß von ferromagnetischen Fremdkörpern, ein exzellentes Verfahren zur Beurteilung und Dokumentation von Schußverletzungen. Abhängig von den Fragestellungen kann dieses bildgebende Verfahren auch in der Rechtsmedizin eingesetzt werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Der Radiologe 40 (2000), S. 404-407 
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Intraorbitales Geschoßprojektil ; Diagnostik ; Magnet-Resonanz-Tomographie (MR) ; Key words Intraorbital gun-shot bullet ; Diagnostics ; Magnetic resonance tomography (MR)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Beside conventional X-ray examination, ultrasound and computer tomographic examination are accepted radiologic techniques to assess the extend of damage of intraorbital injuries. With the exception of a few reports in the literature there is agreement that intraorbital metallic foreign bodies and gun-shot bullets represent a contraindication for magnetic resonance (MR) imaging examination because of artificial imaging side effects and the potential of secondary dislocation of the metallic foreign body due to ferromagnetism. By means of the case reported here it is shown that this general opinion is not universally valid. Depending on the elemental metallic composition of foreign bodies and gun-shot bullets it is demonstrated that MR examination allows high-resolution illustration and in some cases is advantageous compared with other radiologic imaging techniques.
    Notes: Zusammenfassung Zur Beurteilung der Lokalisation und des Ausmaßes durch Fremdkörper verursachter intraorbitaler Verletzungen werden neben den konventionellen Röntgen-Übersichtsaufnahmen der Orbita die Sonographie und die Computertomographie als Methode der Wahl angewendet [2, 4, 5, 12–16, 19, 20, 22, 23]. Mit Ausnahme weniger Autoren besteht die Ansicht, daß metallische Fremdkörper und Geschoßprojektile wegen der Generierung von Artefakten in der Bildgebung und der Gefahr einer sekundären Fremdkörperdislokation aufgrund eines Ferromagnetismus nicht mit Hilfe der Kernspintomographie nachgewiesen bzw. lokalisiert werden dürfen [2–9, 19–23]. Anhand eines Fallberichtes soll gezeigt werden, daß die Verallgemeinerung dieser Ansicht nur eingeschränkt Berechtigung hat und das bei metallischen intrakorporalen Fremdkörpern je nach Art ihrer elementaren metalllischen Zusammensetzung die Kernspintomographie durchaus die Methode der Wahl bei der diagnostischen Bildgebung sein kann.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...