Notes:
The extent of high temperature (900-1,300°C), short time (〈1 s) SO2 capture was found to be limited by temperature-dependent losses in the porosity of calcium based sorbents. At 970°C these porosity losses were caused by CO2-activated sintering. Sulfation of the sorbents either prevented or reduced the extent of porosity losses. Differences in SO2 capture between hydroxides from different commercial sources, and significantly lower levels of capture by calcium carbonates compared to hydroxides were attributed to differences in particle size and the degree of porosity loss.