Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Artikel: DFG Deutsche Nationallizenzen  (62)
Datenquelle
  • Artikel: DFG Deutsche Nationallizenzen  (62)
Materialart
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Science Ltd
    British journal of dermatology 145 (2001), S. 0 
    ISSN: 1365-2133
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Background Contact allergy to topical corticosteroids on patch testing is well recognized, but the clinical significance is uncertain. Objectives To determine the clinical relevance of contact allergy to topical corticosteroids. Methods Seven patients hypersensitive to both budesonide and nickel repeatedly applied budesonide, betamethasone valerate or the common base for both corticosteroids to areas of experimentally induced nickel dermatitis. Nineteen controls allergic to nickel, but not budesonide went through the same procedure. Results Seventy-one per cent of the budesonide-allergic individuals experienced distant ipsilateral flares of toxicoderma-like eruptions, in addition to a severe deterioration of the experimental dermatitis treated with budesonide, i.e. increased erythema, and abundant papules and vesicles. The areas of dermatitis in all of the 19 controls healed uneventfully. Conclusions The clinical relevance of a contact allergy to budesonide was thus substantiated.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    British journal of dermatology 135 (1996), S. 0 
    ISSN: 1365-2133
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: In a double blind experimental study, 20 patients with a contact allergy to gold sodium thiosulphate were challenged intramuscularly with the chemically similar gold sodium thiomalate and with placebo. The most spectacular clinical reaction in the 10 patients given the active agent, was an epidermal and dermal flare up of healed patch-test reactions to the gold salts, as well as a high, but transient, rise in body temperature. Previous intradermal tests were similarly reactivated. In addition, toxicoderma-like rashes were observed in several cases, but a flare up of a previous contact dermatitis site was seen in one patient only. The specificity of the positive provocations was demonstrated.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 1600-0536
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: The aim of this study was to identify the chemicals responsible for the sensitivity of a 44-year-old woman to her own perfume, but showing negative patch test results to the fragrance mix. For this purpose, the perfume concentrate from the eau de toilette was chemically fractionated. Each fraction obtained was afterwards tested on the patient using a ROAT and/or a patch test. Only 1 fraction gave a positive ROAT result. This fraction was analyzed and found to contain coumarin and ethyl vanillin. Coumarin, one of the most widely used fragrance compounds that is not present in the fragrance mix, was confirmed as being the sensitizer.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1600-0536
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Deodorants are one of the most frequently-used types of cosmetics and are a source of allergic contact dermatitis. Therefore, a gas chromatography - mass spectrometric analysis of 71 deodorants was performed for identification of fragrance and non-fragrance materials present in marketed deodorants. Futhermore, the sensitizing potential of these molecules was evaluated using structure activity relationships (SARs) analysis. This was based on the presence of 1 or more chemically reactive site(s), in the chemical structure, associated with sensitizing potential. Among the many different substances used to formulate cosmetic products (over 3500), 226 chemicals were identified in a sample of 71 deodorants. 84 molecules were found to contain at least 1 structural alert, and 70 to belong to, or be susceptible to being metabolized into, the chemical group of aldehydes, ketones and α,β-unsaturated aldehydes, ketone or esters. The combination of GC-MS and SARs analysis could be helpful in the selection of substances for supplementary investigations regarding sensitizing properties. Thus, it may be a valuable tool in the management of contact allergy to deodorants and for producing new deodorants with decreased propensity to cause contact allergy.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 39 (1998), S. 0 
    ISSN: 1600-0536
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Copenhagen : Munksgaard International Publishers
    Contact dermatitis 42 (2000), S. 0 
    ISSN: 1600-0536
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: This study investigated the stability of tixocortol pivalate, budesonide, and hydrocortisone-17-butyrate (Hc-17-B) when present in a mix with petrolatum and when the corticosteroids were kept separately in petrolatum. The concentrations chosen for the corticosteroids were the same as those used in a study within the European Environmental Contact Dermatitis Research Group (EECDRG), in which 2 corticosteroid mixes (1 with a high concentration and 1 with a low concentration) and the 3 individual constituents, each at 2 concentrations, were patch tested. Ethanolic solutions of each corticosteroid, as well as 2 mixtures of these 3 corticosteroids, were also made up at corresponding concentrations. The preparations were kept at room temperature, refrigerated, and deep frozen, and repeatedly for 1 year, investigations to check stability by high performance liquid chromatography were carried out. A decrease of 〈inlineGraphic alt="leqslant R: less-than-or-eq, slant" extraInfo="nonStandardEntity" href="urn:x-wiley:01051873:COD42003144:les" location="les.gif"/〉20% of the initial value at time 0 was used as the threshold for stability. The petrolatum preparations and the ethanolic solutions of budesonide and tixocortol pivalate were stable for at least the whole investigative period, irrespective of storage conditions, while Hc-17-B 1.0% in ethanol kept deep frozen was stable at least during the same period. The latter corticosteroid when kept at room temperature was stable for 3 months only.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 40 (1999), S. 0 
    ISSN: 1600-0536
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Budesonide is advocated as a marker molecule for corticosteroid contact allergy. When patch testing corticosteroids, one must consider their sensitizing potential but also their anti-inflammatory properties, as well as the possibility of different time courses for such properties. The dose-response relationship for budesonide was therefore investigated with regard to dose, occlusion time, and reading time. 10 patients were patch tested with budesonide in ethanol in serial dilutions from 2.0% down to 0.0002% with occlusion times of 48, 24, and 5 h. Readings were on D2, D4, and D7. The 48-h occlusion picked up most positive reactors, 8/10. The D4 reading (48-h occlusion) detected most positive reactors, 8/10, and here 0.002% picked up most contact allergies. Late readings favoured high concentrations. The “edge effect” was noted for several concentrations at early readings. Due to the individual corticosteroid reactivity, the dose-response relationship and the time courses of the elicitation and the anti-inflammatory capacity, several features may be explained, i.e., that lower concentrations may detect budesonide allergy better at early readings, that patients with an “edge reaction” can have positive reactions to lower concentrations.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 38 (1998), S. 0 
    ISSN: 1600-0536
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    ISSN: 1600-0536
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Deodorants are one of the most frequently used types of cosmetics and side-effects from them are common. Recent studies relate perfume allergy to this type of product. 73 deodorants were analyzed by gas chromatography - mass spectrometry for the determination of the contents of 7 well-known fragrance allergens from the fragrance mix and 14 other commonly used fragrance materials. The deodorants were purchased at retail outlets in 5 European countries. It was found that in general, fragrance mix ingredients were more frequently present in vapo- and aerosol sprays than in roll-on products. The levels of the fragrance mix substances ranged from 0.0001–0.2355%. The products investigated contained cinnamic aldehyde and isoeugenol less frequently (17% and 29% respectively), and eugenol and geraniol most frequently (57% and 76% respectively). The 14 other fragrance materials were found in 40–97% of the deodorants, with hedione and benzyl acetate the most frequently found substances. The concentration of these 14 substances ranged from 0.0001–2.7%. It is concluded that the levels of cinnamic aldehyde and isoeugenol found in the deodorants could prove to be relevant for elicitation of contact dermatitis. No conclusions could be drawn about the other fragrance mix constituents, as threshold levels in sensitized individuals have not been investigated. Furthermore, all of the fragrance materials investigated were frequently found in deodorants and, apart from the fragrance mix ingredients, the extent of problems with sensitization to these fragrance materials is largely unknown.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    ISSN: 1600-0536
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Fragrances are one of the major causes of allergic contact dermatitis from use of cosmetics. The aim of the current study was to assess the possible exposure of infants and children to fragrance allergens from cosmetic products and “toy-cosmetics”. 25 children's cosmetics or toy-cosmetic products were analysed by gas chromatography - mass spectrometry. Target substances were the fragrance allergens from the fragrance mix and 14 other fragrance substances, most of which have been described as contact allergens. The fragrance mix ingredients were either not present in children's shampoos/shower gels and cream/lotions, or they were present in fairly low concentrations. In hydro-alcoholic products, such as eau de parfum, eau de toilette, several ingredients of the fragrance mix were found: geraniol was present in 7/7 products, hydroxycitronellal in 6/7 and isoeugenol in 2/7 products. Isoeugenol was present in a maximum concentration of 0.07%. In one cosmetic-toy, cinnamic alcohol was present at 3.7% which exceeds the current industry guideline for safe products by a factor of 5. In all types of products other fragrance allergens were frequently found. In conclusion, children are already exposed at an early age to well-known allergens, sometimes at concentrations which are considered to be unsafe. As contact allergy usually persists for life, manufacturers of children's cosmetics should be aware of their special responsibility and apply the highest possible safety standards.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...