Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • 1997  (2)
Material
Years
  • 1995-1999  (2)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 70 (1997), S. 529-531 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A bunch length monitor for ultrashort (90 fs to 1 ps) electron bunches using a coherent synchrotron radiation detection techniques has been developed in a collaboration between the Thomas Jefferson National accelerator Facility (Jefferson Lab) and the University of Virginia. The noninvasive, high-resolution, high-sensitivity, low-noise monitor employs a state-of-the-art "bandpass" GaAs Schottky whisker diode operated at room temperature. This letter presents the monitor's performance. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Radiation and environmental biophysics 36 (1997), S. 59-66 
    ISSN: 1432-2099
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Notes: Abstract A simplified method for the calculation of mammalian cell survival after charged particle irradiation is presented that is based on the track structure model of Scholz and Kraft [1, 2]. Utilizing a modified linear-quadratic relation for the x-ray survival curve, one finds that the model yields linear-quadratic relations also for heavy ion irradiation. If survival is calculated as a function of specific energy, z, in the cell nucleus – thus reducing the stochastic fluctuations of energy deposition – the increase in slope of the survival curve and therefore the coefficient β z can be estimated with sufficient accuracy from the initial slope, α z . This permits the tabulation of the coefficients α z for the particle types and energies of interest, and subsequent fast calculations of survival levels at any point in a mixed particle beam. The complexity of the calculations can thereby be reduced in a wide range of applications, which permits the rapid calculations that are required for treatment planning in heavy ion therapy. The validity of the modified computations is assessed by the comparison with explicit calculations in terms of the original model and with experimental results for track-segment conditions. The model is then used to analyze the influence of beam fragmentation on the biological effect of charged particle beams penetrating to different depths in tissue. In addition, cell-survival rates after neutron irradiation are computed from the slowing-down spectra of secondary charged particles and are compared to experimental observations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...