Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Physics of Plasmas 6 (1999), S. 4739-4749 
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The electron beam generated in a self-modulated laser-wakefield accelerator is characterized in detail. A transverse normalized emittance of 0.06 π mm mrad, the lowest ever for an electron injector, was measured for 2 MeV electrons. The electron beam was observed to have a multicomponent beam profile and energy distribution. The latter also undergoes discrete transitions as the laser power or plasma density is varied. In addition, dark spots that form regular modes were observed in the electron beam profile. These features are explained by analysis and test particle simulations of electron dynamics during acceleration in a three-dimensional plasma wakefield. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Diamond, with its high radiation damage resistance, is an attractive alternative to silicon for neutron measurements in next step fusion experiments. A 200-μm-thick type IIa natural diamond with Ti/Au contacts was tested at the LAMPF-WNR facility by time-of-flight neutron energy identification. The crystal, having a carrier lifetime of up to 1 ns, was arranged in a low-energy-resolution, high-sensitivity proton recoil telescope consisting of a polyethylene radiator and a low-energy-proton Teflon filter. This arrangement is similar to the triton burnup monitor of Croft et al. [Rev. Sci. Instrum. 64, 1418 (1993)], where a silicon photodiode was used as a recoil proton detector. The observed sensitivity for 14 MeV neutrons (DT) is (1.25±0.15)×10−3 counts/neutron. However, a high contribution of neutron-induced events in the diamond, mainly carbon (A=12) recoils, was observed. A one-dimensional calculation for the detector response to carbon recoil and proton deposition is compared to the measurements. Poor energy resolution of the diamond detector precludes pulse height discrimination between direct 2.5 MeV neutrons events and proton events corresponding to 14 MeV neutrons. Therefore, an overall DT/DD neutron sensitivity ratio of only ∼6.5 is achieved. This value is much lower than the ratio of 540 reported by Croft et al. in their silicon (A=28) monitor.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 3010-3013 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Reactivities of bimetallic clusters can be controlled by varying their composition, making them potentially valuable as catalysts and for use in elucidating the reactivities of such subnanoscale surfaces. A dual rod laser vaporization source coupled to a fast flow reactor is developed for the study of bimetallic clusters and their reactions. In order to establish the versatility of the technique, the results of studies are presented in which Nb/Al clusters are formed in two plasmas induced by the second harmonic (532 nm photons) of a single Nd:YAG laser and then detected by a quadrupole mass spectrometer. The beam from the laser is split and then focused onto each rod, allowing the mixing ratio within the cluster to vary by altering the laser fluence on each rod. With a low fluence on the Nb rod and a high fluence on the Al rod, an Al rich cluster distribution is formed, NbAlm〈sup ARRANGE="STAGGER"〉− (m=2–20), and Alm〈sup ARRANGE="STAGGER"〉− (m=5–31). By increasing the fluence on the Nb rod and decreasing the fluence on the Al rod, a Nb rich cluster distribution is formed, NbnAlm〈sup ARRANGE="STAGGER"〉− (n=3–8 and m=1–3),NbnOAlm − (n=3–8 and m=1–5), andNbnO− (n=3–8). Additional characterization is also performed on V/Al clusters. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 60 (1986), S. 2596-2599 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We have demonstrated that InP:Fe photoconductive detectors are sensitive to radiation between 20 and 3000 eV. Within experimental error the measured response is flat in this energy range, in agreement with theory. This property, coupled with the simplicity and high speed (full width at one half maximum of less than 200 ps) of these devices, makes them very interesting for the measurement of pulsed vacuum ultraviolet and x-ray radiation and the total instantaneous integrated radiative power emitted from a pulsed source. Low fidelity response can occur in these devices for excitation times that are many times longer than the primary response time of the detector.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Genetics 20 (1986), S. 523-538 
    ISSN: 0066-4197
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Biology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 5516-5521 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Conductivity modulated devices, similar to photoconductors in operation, for use as radiation detectors were fabricated from polycrystalline chemical vapor deposited diamond films. These detectors were designed to operate under extremely high radiation fields with a large dynamic range in both response and speed. Two types of detectors were studied: a parallel-plate device and a surface device (SDT). The radiation used to excite these detectors was minimum ionizing electrons with an energy of 16 MeV and a nominal pulse width of less than 25 ps. The response time of all detectors was less than 45 ps. The sensitivity of the detectors was in the range 10−5–10−6 A/W. Over the operating range of the detectors, signal saturation was not observed because to the signal size was small in comparison to the applied bias voltage. The detectors appeared to be linear with dose and dose rate over two orders of magnitude, and for dose rates up to 1013 rad/s. Long-lived signal decay tails contributed to much less than 1% of the signal. The response of a SDT detector appeared to be independent of the orientation of the detector to the incident beam direction when the excitation source is minimum ionizing. It appears that the dose-rate linearity may be extended to a range greater than 1013 rad/s. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 56 (1985), S. 846-846 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Recently we have demonstrated that InP:Fe photoconductors are fast (FWHM∼150 ps), sensitive (2.7×10−3 A/W), and flat response soft x-ray detectors using synchrotron radiation from the Stanford Synchrotron Radiation Laboratory.1 We have applied these to the measurement of the radiation emitted by a collapsing annular gas (argon) puff z-pinch plasma. The detector was used in two modes of operation: (1) a filtered soft x-ray detector as a pinch diagnostic and (2) a fast unfiltered bolometer to measure the total radiated power as a function of time. We will compare the performance of the photoconductors to other common fast x-ray detectors and bolometers.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 2182-2183 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Photoconductors are very promising x/γ-ray detectors and x-ray bolometers for pulsed x/γ-ray measurements. They are fast, sensitive, and theoretically flat in spectral response for low energy x rays. We report our tests of InP:Fe, GaAs, and GaAs:Cr, both neutron damaged and undamaged, at Nova laser, Febetrons, and electron linear accelerators. The temporal and spectral responses are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 68 (1996), S. 3016-3018 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A quantitative measure of grain-boundary effects on the carrier transport properties in polycrystalline chemical-vapor-deposited diamond has been obtained using a 10-ns hard x-ray excitation source. Two device geometries were used to gain insight into the extent of grain-boundary effects: one having the applied electric field normal and the other parallel to the grain orientation. The applied electric field intensity was varied to adjust the mean-free carrier drift distance. The degradation in the carrier transport properties at an electric field intensity of 10 kV/cm by the grain-boundary appears to be approximately a factor of two in comparison to the intragrain carrier transport.© 1996 American Institute of Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Macromolecules 20 (1987), S. 2531-2535 
    ISSN: 1520-5835
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...