Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 5252-5256 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: For plasma-assisted processing of future semiconductor devices, a new compact electron cyclotron resonance (ECR) plasma source has been specifically designed. The source is novel in that the magnets required for the production of ECR plasma are movable even in vacuum, and in situ monitoring of the discharge zone is also possible. Typical plasma characteristics were evaluated for nitrogen gas using Langmuir probe diagnostics and ion energy analysis. The measured plasma parameters include electron densities in excess of 1010 cm−3 and low ion energies (〈30 eV) with narrow distributions, which can be easily controlled by varying the discharge pressure and downstream position. Moreover, changing the aperture size of the discharge cavity enables one to control the relative ratio of the ionic and atomic species in the plasma. In determining plasma stability, changes in plasma parameters after plasma start-up were investigated. The results show a correlation between changes in the plasma potential and the total plasma optical emission. In situ monitoring of the total plasma emission is suggested as a simple means of providing valuable information in real time about physical plasma parameter changes during processing. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Suite 500, 5th Floor, 238 Main Street, Cambridge, Massachusetts 02142, USA : Blackwell Science Inc.
    International journal of gynecological cancer 5 (1995), S. 0 
    ISSN: 1525-1438
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Exfoliated cervical cells from 321 Japanese women were examined for human papillomavirus (HPV) DNA types 6, 11, 16, 18, 31, 33 and 35 using polymerase chain reaction (PCR) and dot-blot hybridization methods. HPV DNA was present in 9.3% of patients with normal cervixes, 72.7% of patients with cervical intraepithelial neoplasia (CIN) and 77.8% of patients with invasive carcinoma. Younger patients (〈inlineGraphic alt="leqslant R: less-than-or-eq, slant" extraInfo="nonStandardEntity" href="urn:x-wiley:1048891X:IJG05010045:les" location="les.gif"/〉29 years) with normal cervixes had a 18.5% incidence of HPV DNA, whilst similar older patients (〈inlineGraphic alt="geqslant R: gt-or-equal, slanted" extraInfo="nonStandardEntity" href="urn:x-wiley:1048891X:IJG05010045:ges" location="ges.gif"/〉50 years) had a 1.9% incidence, a significant difference (χ2= 6.478, P 〈 0.01). In the CIN I and II groups, an incidence of 11.1% of types 16 and 18 was found, while in the CIN III or invasive carcinoma group the incidence was 58.1%, again a significant difference (χ2 = 12.075, P 〈 0.01). Furthermore, persistence or progression of CIN showed a significant correlation with infections by types 16 and 33 (χ2= 4.904, P 〈 0.01). However, no significantly different incidence of HPV infection was found between the CIN and the invasive carcinoma groups. It is suggested that (a) younger patients with normal cervixes have a higher incidence of HPV infection than do older patients; (b) HPV types 16, 18 and 33 are important etiologic agents of CIN III and invasive carcinoma, as well as in the persistence and progression of CIN; (c) progression of CIN to invasive carcinoma may depend on factors other than HPV infection in the cervix.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1520-4804
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anatomia, histologia, embryologia 27 (1998), S. 0 
    ISSN: 1439-0264
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The nasopharynx and eustachian tube (auditory tube) were morphologically examined in the white rhinoceros. The narrow nasopharynx cavity was enlarged dorsoventrally. The most lateral part of both sides sharply rises in a dorsal direction and the volume is estimated at 173 cc. The eustachian tube is 145 mm in length from the auditory bulla to the nasopharynx. The hyaline cartilage is well-developed in the middle region of the eustachian tube wall. The results demonstrated that the white rhinoceros does not have a guttural pouch. We suggest that the occurrence of the guttural pouch may not be dependent on the phylogenetic status of perissodactyls such as horse, donkey and tapir.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford [u.a.] : International Union of Crystallography (IUCr)
    Acta crystallographica 54 (1998), S. 1527-1529 
    ISSN: 1600-5759
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1600-5775
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1435-1536
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1438-2199
    Keywords: Amino acids ; Adenosine ; Taurine ; Hippocampus ; Microdialysis ; Spreading depression
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The present study was designed to examine which type of adenosine receptors was involved in enhancement of high K+-evoked taurine release fromin vivo rat hippocampus using microdialysis. Perfusion with 0.5 or 5.0 mM adenosine enhanced high K+-evoked taurine release. Perfusion with 2μM R(−)-N6-2-phenylisopropyladenosine (PIA), a selective adenosine A1 receptor agonist, did not modulate taurine release. Perfusion with 1μM 1,3-dipropyl-8-cyclopentylxanthine (DPCPX), a selective adenosine A1 receptor antagonist, increased taurine release. On the other hand, perfusion with 20μM 2-[4-(2-carboxyethyl)phenethylamino]-5′-N-ethyl-carboxamideadenosine (CGS21680), a selective adenosine A2A receptor agonist, enhanced taurine release, while perfusion with 1 mM 3,7-dimethyl-propagylxanthine (DMPX), an adenosine A2 receptor antagonist, did not affect taurine release. These results demonstrate that adenosine enhances high K+-evoked taurine release via activation of adenosine A2A receptors from both neurons and glial cells ofin vivo rat hippocampus.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1433-2981
    Keywords: Cold storage ; Cold transport ; Dog ; Haematology ; Parameters ; Rat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A sample surveillance programme is scheduled to be conducted on measurement methods of haematology parameters which will include the participation of over 70 facilities. In preparation for that programme, a preliminary study was conducted, at five of the facilities, on the effects of cold storage and transport on rat and dog blood samples. The blood samples used in this study were taken from healthy, untreated rats and dogs from stocks held at each facility, and were anticoagulated with EDTA-2K. The blood samples were stored undisturbed at 4–10°C. The effects of transporting samples were also investigated by placing aliquots of the same samples in a cooler (4–13°C) containing a cold insulator. Red blood cell counts (RBC), total white blood cell counts (WBC), haematocrit (HCT), haemoglobin (HGB) and platelets (PLT) were measured twice for each sample, i. e., fresh and 24 hours later, and these results were compared. Although blood sampling conditions were similar for all facilities, each facility employed its own method with respect to the analysis. Automated haematology analysers used included the Toa Sysmex E4000/CS, Toa Sysmex E5000, Coulter S-Plus STRK, Technicon H*1 and Nihon Kohden MEK-4500. In the case of rat blood samples, measured values after undisturbed cold storage, fluctuating by −2 to +1% in comparison with values before storage. Measured values after cold transport fluctuated by −2 to +7% in comparison with those before transport. It was concluded, for rat blood samples, that neither storage condition had a significant effect on the results. In the case of dog blood samples, RBC, HCT and HGB values fluctuated by +1 to +2% and 0 to +2% in comparison with prestorage and pretransport values, respectively. They were not, therefore, significantly affected by undisturbed cold storage or cold transport. However, WBC values increased by +18% after undisturbed cold storage and by +18% after cold transport. Conversely, PLT values decreased by −20% both after undisturbed cold storage and cold transport. It is known that dog blood samples are affected by cold storage, and a similar trend was observed in this study. On the basis of these results, it was concluded that the distribution of rat blood samples for the conduct of a sample survey of analytical methods under cold storage is suitable, and that it will be necessary to have the samples prepared at a single facility.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1433-2981
    Keywords: Control survey ; Haematology ; Inter laboratory variation ; Rat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A survey was conducted to determine the accuracy and quality control of automated haematology analysers used in non-clinical toxicity studies. Pooled blood samples from male Sprague-Dawley rats were distributed to 98 laboratory facilities throughout Japan, the samples being delivered under refrigeration to each facility within 18 h of sample preparation. At each facility, the samples were analysed within 4 h of receipt. Commercially available normal human blood samples from a single lot were also analysed at the same time. Most haematological results were within the mean ±3SD (standard deviation), but some facilities gave either high or low values consistently for both human and rat samples. No facility gave high or low values to certain parameters sporadically, which suggests no problem with the accuracy of the equipment. However, it was suspected that there would be some problem in comparing analytical values determined in a unique way by specific equipment design. The use of certain equipment resulted, in rat haematocrit values in particular, being either too high or too low. In these cases, it was deemed necessary to make some adjustments or calibration changes. There were also platelet values with a ‘plus drift’ which was apparently due to contamination with, or failure to identify small red blood cells (RBC). There was no deviation in values which could be attributed solely to the mechanical operation of any of the analytical equipment. Non-standard, initial setting up of the equipment (originally intended for human use, but now used for a variety of animal species) has been recognised as the main cause for a wider range of the analytical values seen. The results of this survey suggest that it may be necessary to review equipment calibration at each facility, and to re-establish the historical background data.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...