Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0711
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Macromolecules 28 (1995), S. 6942-6949 
    ISSN: 1520-5835
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Macromolecules 28 (1995), S. 1825-1834 
    ISSN: 1520-5835
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Macromolecules 28 (1995), S. 6556-6564 
    ISSN: 1520-5835
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    s.l. ; Stafa-Zurich, Switzerland
    Materials science forum Vol. 225-227 (July 1996), p. 341-346 
    ISSN: 1662-9752
    Source: Scientific.Net: Materials Science & Technology / Trans Tech Publications Archiv 1984-2008
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1662-9752
    Source: Scientific.Net: Materials Science & Technology / Trans Tech Publications Archiv 1984-2008
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Lebensmittel-Untersuchung und -Forschung 205 (1997), S. 242-247 
    ISSN: 1431-4630
    Keywords: Key words Aluminium ; Wild mushrooms ; Cultivated Agaricus bisporus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract  The aluminium content in wild mushrooms (n = 271, 19 species) and in cultivated Agaricus bisporus (n = 15) was determined by graphite furnace atomic absorption spectroscopy. With an aluminium content of 30 – 50 μ/g dry matter (DM) Boletus and Xerocomus species, the most well-known and most popular mushrooms, proved to be poor in aluminium. Several species of the genus Suillus, Macrolepiota rhacodes, Hypholoma capnoides as well as individual samples of Russula ochroleuca and Amanita rubescens contained high aluminium concentrations of about 100 μg/g DM and more. Cultivated Agaricus bisporus had the lowest aluminium content, i. e. 14 μg/g DM. The site, its geological origin as well as the mushroom species influenced the aluminium content in the fruitbodies: these factors require further investigation. Mushrooms do not contribute significantly to aluminium intake by humans.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Autologe Transfusion ; maschinelle Autotransfusion ; Leukozyten-Depletionsfilter ; Osteosarkomzellen ; Tumorchirurgie ; Key words Autologous transfusion ; Intraoperative autotransfusion ; White blood cell depletion filter ; Osteosarcoma ; Tumor cells ; Tumor surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Intraoperative autotransfusion is contraindicated in cancer surgery because of the possible risk of systemic tumor spread. The aim of the present study was to investigate whether a cell saver in combination with a white blood cell depletion filter can remove osteosarcoma cells. Methods. A defined number of osteosarcoma cells from an established cell line were added to red cell concentrates and Ringer solution. The tumor cell concentration was 1000/ml in the first five experiments, 7111/ml in test no. 6, 1667/ml in test no. 7 and 167/ml in test no. 8. Following thorough mixing, each unit was processed separately by a cell saver (DIDECO BT 795/P) in its normal operation mode to produce a red cell concentrate. This red cell concentrate was filtered using a leukocyte depletion filter (PALL BPF 4). Samples were taken before and after processing with the autotransfuser and after filtration with the white cell depletion filter. Cytospin specimens from all samples were examined for osteosarcoma cells by three different methods (Papanicolaou stain, Vimentin antibodies, DNA analysis). Results. After processing with the autotransfuser, tumor cells were identified in the red cell concentrate. No osteosarcoma cells were evident after the combined use of cell saver and leukocyte depletion filter. Conclusion. The sole use of the autotransfuser DIDECO BT 795/P during osteosarcoma surgery is not recommended because of the potential danger of retransfusion of malignant cells. In combination with the leukocyte depletion filter PALL BPF 4, no osteosarcoma cells were identified in the red cell concentrate. Since the adhesiveness of tumor cells from established cell lines may be different from that of tumor cells in the intraoperative salvaged blood, further studies with blood from the surgical field are necessary to determine the efficacy of white cell depletion filters to eliminate osteosarcoma cells.
    Notes: Zusammenfassung Der Einsatz der Maschinellen Autotransfusion (MAT) wird in der orthopädischen Tumorchirurgie wegen der Gefahr einer systemischen Tumorzellaussaat als kontraindiziert angesehen. In dieser Studie wird untersucht, ob die MAT in Verbindung mit einem handelsüblichen Leukozyten-Depletionsfilter in der Lage ist, Osteosarkomzellen aus dem Wundblut zu eliminieren. Eine definierte Menge angezüchteter Osteosarkomzellen wird mit einem Erythrozytenkonzentrat und Ringerlösung vermischt. Dieser Versuchsansatz wird mit einem maschinellen Autotransfusionssytem aufbereitet und anschließend durch einen handelsüblichen Leukozyten-Depletionsfilter gefiltert. Standardisierte Proben werden nach der Papanicolaou-Klassifikation, immunzytochemisch (Vimentinexpression) und mit der DNA-Analyse auf Osteosarkomzellen untersucht. Nach der maschinellen Aufbereitung im Autotransfusionsgerät und der Passage des Leukozyten-Depletionsfilters konnten keine Osteosarkomzellen mehr nachgewiesen werden. Im Gegensatz hierzu wurden durch die alleinige Aufbereitung im Autotransfusionsgerät die Osteosarkomzellen nur unzureichend separiert. Obwohl mit den verwendeten Nachweisverfahren keine Tumorzellen im filtrierten Blut mehr nachgewiesen werden konnten, muß bei der Beurteilung der Eliminationsleistung des Leukozyten-Depletionsfilters berücksichtigt werden, daß diese Filter in ihrem eigentlichen Einsatzgebiet lediglich eine definierten Reduktion der Leukozyten bewirken. Darüber hinaus können Tumorzellen aus Zellkulturen ein besonderes Adhäsionsverhalten gegenüber künstlichen Oberflächen aufweisen. Weitere Untersuchungen mit Tumorzellen aus dem Wundblut sind daher notwendig, um den Stellenwert der Leukozyten-Depletionsfilter bei der Elimination von Osteosarkomzellen endgültig beurteilen zu können.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Der Anaesthesist 48 (1999), S. 3-8 
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Point-of-Care-Testing (POCT) ; Turn-Around-Time ; Zentrallabor ; Intensivstation ; Notfallaufnahme ; Key words Point-of-Care-Testing (POCT) ; Turn-Around-Time ; Central Laboratory ; Intensive Care Unit ; Emergency Room
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract After successful centralization of laboratory analyses since more than 30 years, advances in biosensors, microprocessors, measurement of undiluted whole blood and miniaturization of laboratory analyzers are leading nowadays more and more to a re-decentralization in the laboratory medicine. Point-of-care-testing (POCT), which is defined as any laboratory test performed outside central or decentralized laboratories, is becoming more and more popular. The theoretical advantages of POCT are faster turn-around-times (TAT), more rapid medical decisions, avoidance of sample identification and sample transport problems and the need of only small specimen volumes. These advantages are frequently mentioned, but are not associated with a clear clinical benefit. The disadvantages of POCT such as incorrect handling and/or maintenance of the analyzers by non-trained clinical staff, inadequate or even absent calibrations and/or quality controls, lack of cost-effectiveness because of an increased number of analyzers and more expensive reagents, insufficient documentation and difficult comparability of the obtained POCT-results with routine laboratory results, are strongly evident. According to the authors’ opinion the decision for the establishing of POCT has only to be made in a close co-operation between physicians and laboratorians in order to vouch for necessity and high quality of the analyses. Taking the local situation into consideration (24-h-central laboratory, etc.) the spectrum of parameters measured by means of POCT should be rigorously restricted to the vital functions. Such analytes should be: hemoglobin or hematocrit, activated whole blood clotting time, blood gases, sodium, potassium, ionized calcium, glucose, creatinine, ammonia and lactate.
    Notes: Zusammenfassung Nach erfolgreicher Zentralisierung der Laboranalytik seit mehr als 30 Jahren, führen Fortschritte bei Biosensoren, Mikroprozessoren, Messung in unverdünntem Vollblut und die Verkleinerung von Laboranalysen heute wieder immer mehr zu einer neuerlichen Re-Dezentralisierung in der Labormedizin. Das Point-Of-Care-Testing (POCT) wird nahe dem Patienten außerhalb von zentralen oder dezentralen Laboratorien durchgeführt. Die theoretischen Vorteile des POCT sind schnellere Turn-Around-Times (TAT), schnellere medizinische Entscheidungen, Vermeidung von Probenidentifizierungs- und Probentransportproblemen sowie die Notwendigkeit von nur kleinen Probenmengen. Diese Vorteile werden zwar oft hervorgehoben, gehen jedoch nicht mit einem klar erkennbaren klinischen Nutzen einher. Die Nachteile des POCT wie unsachgemäße Handhabung und/ oder Wartung der Analysengeräte durch das ungeschulte Stationspersonal, mangelnde oder fehlende Kalibration und/oder Qualitätskontrolle, Kosten durch Vorhaltung mehrerer Geräte und teurerer Reagenzien, insuffiziente Dokumentation und schwierige Vergleichbarkeit zwischen den POCT-Ergebnissen und den Routinelaborergebnissen, sind ebenfalls augenscheinlich. Nach Meinung der Autoren sollte die Entscheidung zur Etablierung eines POCT nur in engster Kooperation zwischen Klinikern und Labormedizinern erfolgen, um Sinnhaftigkeit und hohe Qualität der Analysen zu gewährleisten. Unter Berücksichtigung der lokalen Situation (24 h-Zentrallabor, etc.) sollte sich das Parameterspektrum des POCT streng auf vitale Funktionen beschränken. Die dafür notwendigen Analyte sollten sein: Hämoglobin oder Hämatokrit, Aktivierte Vollblut-Gerinnungszeit, Blutgase, Natrium, Kalium, ionisiertes Kalzium, Glukose, Ammoniak und Laktat.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Der Anaesthesist 45 (1996), S. 731-736 
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Isofluran ; Propofol ; Rückatmung ; Kosten ; Anästhesie ; Strumektomie ; Cholezystektomie ; Key words Isoflurane ; Propofol ; Anaesthesia ; Costs ; Thyroidectomy ; Cholecystectomy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Cost control is no longer an option, but a necessity. Propofol anaesthesia is expensive, however, the true differences in comparison to volatile anaesthetics (isoflurane) are not known. Methods. Sixty patients undergoing either thyroidectomy (n=30) or laparoscopic cholecystectomy (n=30) were randomly divided into 3 groups of 20 patients. In group I propofol and fentanyl were used for anaesthesia, in group II isoflurane (,standard` isoflurane anaesthesia), and in group III isoflurane using a low-flow system (fresh gas flow 2 l/min) was given. All patients were ventilated using 70% N2O in oxygen. Vecuronium was used in all cases for muscle relaxation. Isoflurane consumption was measured by weighing the isoflurane vaporiser. Results. Biometric data and time of administration of the anaesthetic were similar in the three groups. Propofol patients stayed significantly shorter than isoflurane patients in the postanaesthesia care unit (PACU). Costs of additional drugs (antiemetics, analgesics) in the PACU were least in the propofol patients. Costs were without differences between the propofol (78.30 DM/patient) and `standard' isoflurane groups (81.69 DM/patient). Patients in group III showed the lowest overall costs (57.46 DM/patient) (P〈0.05). Conclusion. A climate of cost-consciousness and cost-containment prevails at the present time. The costs of propofol and `standard' isoflurane anaesthesia were without differences; however, isoflurane used in a low-flow system had the lowest cost in this study. Doubts are justified, however, as to whether the choice of anaesthetic agents may considerably lower the costs of an anaesthesia department.
    Notes: Zusammenfassung Im Rahmen von Anästhesie und Intensivmedizin geraten Kostenaspekte immer mehr in den Mittelpunkt des Interesses. Propofol ist in vielen Zentren zur Narkosedurchführung etabliert, die höheren Kosten werden jedoch immer wieder als Argument gegen den Einsatz dieser Substanz angeführt. Der tatsächliche Kostenunterschied im Vergleich zu einer Narkose mit volatilen Anästhetika (z.B. Isofluran) ist jedoch nicht eindeutig belegt. 60 Patienten, die sich einer laparoskopischen Cholezystektomie (n=30) bzw. einer Strumektomie (n=30) unterziehen mußten, wurden prospektiv randomisiert und in 3 Gruppen zu je 20 Patienten aufgeteilt: in Gruppe I wurde die Narkose mit Propofol, Fentanyl und N 2 O durchgeführt, in Gruppe II kam Isofluran/N 2 O ohne Rückatmung zur Anwendung und in Gruppe III wurde Isofluran/N 2 O mit Rückatmung (Frischgasfluß 2 l/min) eingesetzt. Alle Patienten erhielten bedarfsadaptiert Vecuronium zur Muskelrelaxation. Der jeweilige Isofluranverbrauch wurde durch Wiegen des Isofluran-Einspritzers ermittelt. Die biometrischen Daten, perioperativen hämodynamischen Daten sowie die Operationszeiten und die Dauer der Narkosemittelzufuhr waren für alle drei Gruppen vergleichbar. Die Propofolpatienten verblieben signifikant kürzer im Aufwachraum als die Patienten der beiden Isoflurangruppen. Auch der Bedarf (und die Kosten) an Antiemetika und Analgetika im Aufwachraum lag in der Propofolgruppe niedriger als in den Isoflurangruppen. Die Anästhesiekosten pro Patient waren für die Propofol- (78,30 DM/Patient) und Isolfurangruppe ohne Rückatmung (81,69 DM/Patient) ohne signifikanten Unterschied. Die Patienten der Gruppe III (Isofluran mit Rückatmung) wiesen die signifikant niedrigsten Kosten auf (57,46 DM/Patient). Zusammenfassend läßt sich feststellen, daß die tatsächlichen Kosten der einzelnen Anästhesieverfahren (einschließlich Personal- und sonstigen Materialkosten) schwer zu definieren sind. Inwieweit die totalen Kosten im Krankenhaus bzw. in einer Anästhesieabteilung durch die Wahl des Anästhetikums wirksam zu senken sind, muß in größeren Untersuchungen überprüft werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...