Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Allergy 53 (1998), S. 0 
    ISSN: 1398-9995
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The nasal mucociliary clearance is an important defense mechanism of the upper respiratory tract. It is known to be influenced by many pharmacologic substances. We investigated the effects of three topical intranasal antiallergic formulations containing disodium cromoglycate (DNCG), dimethindene maleate (DMM), and azelastine-HCL (AZL) on nasal ciliary beat frequency (CBF) in vitro. Nasal ciliated cells were harvested from 16 healthy volunteers. Cells were diluted 1:10 in culture medium and incubated with a placebo formulation (PLAC), containing 0,022% benzalkonium chloride, which was part of all formulations, a registered 2% formulation of DNCG, a 0.1% formulation of DMM, and a registered 0.1% formulation of AZL. After an incubation period of 20 min, CBF was registered by a photoelectric measurement device. Under control conditions (CONTROL), CBF was 11 4±1 3 Hz. PLAC reduced CBF to 9.7±2.3 Hz (NS). DNCG reduced CBF t o 9.7±2 Hz (NS). DMM reduced CBF to 7.2+1.7 Hz F〈0.O5 vs CONTROL, NS vs PLAC), and AZL reduced CBF to 0.9+1.8 Hz P ≤ 0.05 vs CONTROL, P ≤ O.001 vs DNCG, P 〈 0.001 vs PLAC). In conclusion, a possible influence of antiallergic intranasal formulations on nasal ciliary function has to be considered in clinical application.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    HNO 47 (1999), S. 294-295 
    ISSN: 1433-0458
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Direkte Lautheitsskalierung ; Hörfeldskalierung ; Lautheitswahrnehmung ; Recruitment ; Akustikusneurinom ; Key words Category loudness scaling ; Hearing field audiometry ; Sound perception ; Recruitment ; Acoustic neuroma
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Category loudness scaling was used to investigate the loudness perception of 31 patients with a cochlear hearing loss (Group 1) by comparing the results with those found in 15 patients with retro-cochlear hearing loss caused by an acoustic neuroma (Group 2). Narrow-band noise signals at four different frequencies (0.5 to 4.0 kHz) were used. In the cochlear hearing-impaired subjects the slopes of the level-loudness functions tended to increase with increasing hearing loss, indicating positive recruitment, whereas the much shallower slopes associated with retro-cochlear lesions were presumed to reflect negative recruitment. The graphic representation of the iso-loudness functions revealed a different dynamic range between Group 1 and 2 with the ability to discriminate small differences of stimulus levels reduced in the presence of an acoustic neuroma. Category loudness scaling has been shown to be a valuable tool describing the individual perception of sound in a qualitative and quantitative manner. Furthermore, the method can be employed as an indicator of recruitment without any restrictive preconditions. For this reason the categorial loudness scaling can be a desirable method for supplementing the audiological diagnosis of a retro-cochlear hearing impairment through the frequency-specific description of a usable hearing-field and its dynamic range.
    Notes: Zusammenfassung Die Hörfeld- bzw. Hörflächenskalierung erlaubt es, die subjektive Empfindungsgröße „Lautheit” individuell, frequenzspezifisch und quantitativ zu erfassen. Ziel der Arbeit ist, den aktuellen Wissensstand zur Lautheitswahrnehmung bei retrokochleären Läsionen zu ergänzen. Mit Hilfe des Testmaterials der Würzburger-Hörfeldaudiometrie zur kategorialen Lautheitsskalierung wurde die Lautheitsempfindung dreier Probandengruppen miteinander verglichen: 1. kochleäre Hörstörung, 2. intrameatal lokalisiertes Akustikusneurinom, 3. tonaudiometrische Hörschwelle besser als 10 dB. Die Hörfeldskalierung erfolgte jeweils monaural über Kopfhörer für Rauschimpulse der Mittenfrequenzen 500, 1000, 2000 und 4000 Hz im Pegelbereich zwischen 20 und 90 dB HL. Da die Lautheitsurteile primär vom Hörverlust in der Prüffrequenz, jedoch weniger von der Hörminderung in den Nachbarfrequenzen bestimmt sind, wurde die Klassifikation der Skalierungsergebnisse entsprechend dem Hörverlust in der Testfrequenz vorgenommen. Mit zunehmendem kochleären Hörverlust zeigten die gemittelten Pegellautheitsfunktionen in der graphischen Darstellung einen deutlich steileren Verlauf als bei Probanden mit tonaudiometrisch sehr geringem Hörverlust. Dieses Ergebnis kann im Sinne eines Recruitments gewertet werden. Im Vergleich dazu zeigte der Graph der hörverlustbezogenen Pegellautheitsfunktionen bei Akustikusneurinom einen deutlich flacheren Verlauf. In den Isolautheitskurven wurde zudem ein unterschiedlicher Dynamikbereich deutlich: bei bestehender retrokochleärer Läsion war die Diskriminationsfähigkeit kleiner Pegelunterschiede eines Stimulus herabgesetzt. Der klinische Nutzen der Hörfeldskalierung liegt in der Möglichkeit, das Ausmaß eines Lautheitsausgleichs unmittelbar zu erfassen. Bei nachgewiesener retrokochleärer Hörstörung eröffnet sie Möglichkeiten einer differenzierten Beschreibung des überschwelligen Gehörs mit entsprechender frequenzspezifischer Beurteilung der Restdynamik und ergänzt damit das Testrepertoire zur Beurteilung der Hörfähigkeit bei retrokochleären Läsionen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-0711
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-0711
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-0711
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Paukenröhrcheninfektion ; Otorrhö ; Pseudomonas aeruginosa ; Staphylococcus aureus ; Silikonröhrchen ; Goldröhrchen ; Key words Tympanostomy tubes ; Postoperative otorrhea ; Silicon tubes ; Gilded silver tubes ; Staphylococcus aureus ; Pseudomonas aeruginosa
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Otorrhea is the most common complication after tympanostomy tube insertions. In Germany there are currently two commonly used types of tympanostomy tubes: silicon tubes (ST) and gilded silver tubes (GT). Previously published in vitro studies by Tajima uncovered a positive correlation between the silicon concentration in culture fluid and the rate of growth of Staphylococcus aureus. Our study retrospectively evaluates the types of bacteria and rates of otorrhea after ST and GT insertions. The present study was undertaken to determine which of these tubes had a higher incidence of otorrhea and then whether silicon tubes stimulated the growth of certain types of bacteria, such as Staphylococcus aureus. In all, 186 ST and 59 GT were placed in 245 ears of 144 children. Both ST and GT were separated into three groups: first insertion of a tympanostomy tube, second implantation and insertion of a tympanostomy tube in an infected ear in the course of a mastoidectomy. No differences between ST and GT in causing otorrhea were found in the three groups. Nevertheless, ST in comparison to GT was associated with a higher incidence of infections with Pseudomonas aeruginosa. In contrast, a higher incidence of Staphylococcus aureus related to ST could not be proved. Twenty percent of the ears with mastoiditis were found to have Pseudomonas aeruginosa, but none of these ears implanted with a GT developed postoperative otorrhea. Our findings show that GT should be used when a ventilation tube is used during a mastoidectomy. Further, it is tenable to implant only GT because postoperative otorrhea in many cases is caused by insufficient water protection and water isfrequently polluted with Pseudomonas aeruginosa.
    Notes: Zusammenfassung Häufigste Komplikation nach Paukenröhrcheneinlage ist die postoperative Otorrhö. Zur Paukendrainage werden in Deutschland vielfach Silikonröhrchen (SR) und Goldröhrchen (GR) benutzt. Interessant sind diesbezüglich In-vitro-Untersuchungen, bei denen eine steigende Silikonkonzentration im Nährmedium das Wachstum von Staphylococcus aureus stimulierte. Wir haben deshalb die Otorrhöhäufigkeit und das Keimspektrum von SR und GR retrospektiv untersucht. Ziel war es zu klären, ob SR mit einem höheren Infektionsrisiko behaftet sind oder ob sie das Wachstum bestimmter Keimarten begünstigen. Innerhalb von 2 Jahren wurden bei 144 Kindern 186 SR und 59 GR implantiert und in folgende 3 Untergruppen eingeteilt: Ersteinlage, Rezidiveinlage und Implantation in ein infiziertes Ohr bei Mastoidektomie. In allen 3 Gruppen fand sich zwar kein Unterschied bezüglich der Otorrhoehäufigkeit; SR waren jedoch signifikant häufiger mit Pseudomonas aeruginosa infiziert als GR (p=0,025). Bei 20% der Ohren mit Mastoiditis ergab der intraoperative Abstrich eine Infektion mit Pseudomonas aeruginosa. All diese infizierten, mastoidektomierten Ohren wurden mit GR versorgt. Keines dieser Ohren zeigte jedoch postoperativ eine Infektion mit Pseudomonas aeruginosa. Im Rahmen einer Mastoidektomie sollten daher unbedingt GR implantiert werden, die einen protektiven Effekt gegenüber Pseudomonas aeruginosa zeigen. Unter dem Aspekt, daß die durch mangelnden Wasserschutz bedingten Paukenröhrcheninfektionen recht häufig sind und Pseudomonas aeruginosa typischerweise im feuchten Milieu vorkommt, ist eine generelle GR-Implantation zur Paukendrainge durchaus zu vertreten.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    HNO 45 (1997), S. 385-388 
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Langsame Augenfolgebewegungen ; Blickfolgeprüfung ; Glatte Blickfolge ; Zentral-vestibuläre Störung ; Pendelblickfolgetest ; Key words Central vestibular disease ; Smooth pursuit eye movements ; Pendular eye-tracking test
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Testing gaze movements is very important for the detection of central vestibular diseases. The intent of this study was to clarify the pathological importance of partially disturbed and completely disturbed smooth pursuit movements. One hundred patients were analyzed and curves of smooth pursuit movements were classified into three groups of different deformations: i.e, regular, partially disturbed and completely disturbed movements. The correlation index of each curve was then calculated. In 16 patients qualitative analysis showed a completely disturbed result in the smooth pursuit test. Nine of the patients (56.3%) showed morphological signs of a central disease. Twenty-nine patients yielded a partially disturbed test result and in 2 of them (6.9%) a central pathological illness was uncovered. Patients with completely disturbed smooth pursuits showed the highest average binocular correlation index (1.44). Others with partially disturbed results gave an index of 1.24, while persons with regular smooth pursuits yielded a value of 1.17. Because of the scattering seen, it was not definitely possible to attach a correlation index to central disease. On the other hand, an index higher than 1.3 should arouse suspicion for a central illness. Only completely disturbed smooth pursuit movements frequently appear in connection with central diseases. As a rule, a partially disturbed result does not indicate diseases of the central nervous system.
    Notes: Zusammenfassung Die Prüfung der willkürlichen langsamen Augenfolgebewegungen liefert wichtige Hinweise zur Aufdeckung zentral vestibulärer Störungen. Ziel war es zu klären, ob neben der komplett gestörten auch einer partiell gestörten Blickfolgebewegung ein Krankheitswert zukommt. Retrospektiv wurde bei 100 Patienten die Blickfolgeprüfung analysiert. Die einzelnen Kurvenverläufe wurden den 3 Gruppen der regelrechten, der partiell gestörten und der komplett gestörten Blickfolge zugeordnet und anschließend der Übereinstimmungsquotient errechnet; 16 Patienten zeigten qualitativ eine komplett gestörte Blickfolge, und bei 9 von ihnen (56, 3%) ließ sich ein morphologisches Korrelat im Sinne einer zentralen Erkrankung finden. Bei 29 Patienten ergab sich eine partiell gestörte Blickfolge, und nur bei 2 von ihnen (6,9%) fand sich eine zentrale Pathologie. Durchschnittlich fand sich der höchste beidäugig gemessene Übereinstimmungsquotient mit 1,44 in der Gruppe mit komplett gestörter Blickfolge. In der Gruppe mit partiell gestörten Augefolgebewegungen lag er bei 1,24 und in der mit regelrechter Blickfolge bei 1,17. Nur eine komplett gestörte Blickfolge korreliert in den meisten Fällen mit einer zentralen Erkrankung. Partiell gestörte Augenfolgebewegungen haben in der Regel keine pathologische Bedeutung.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Tinnitus ; Direkte Lautheitsskalierung ; Hörfeldskalierung ; Lautheitswahrnehmung ; Key words Free-field audiometry ; Loudness scaling ; Sound perception
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary We used free-field audiometry to investigate the loudness perception of unilateral high-frequency tinnitus in 16 “normal-hearing” ears by comparing the results with loudness scaling in 20 normally hearing ears without any tinnitus. Narrow-band noise signals at four different frequencies from 500 to 4000 Hz were employed. The parameters used included the slope m of the loudness function and the level Lm (corresponding to the loudness perception of “medium loud”) as well as the suitability of fit (ΔFIT). The results showed that in subjects with tinnitus the slope of the mean loudness level tended to decrease at 4000 Hz. The dynamic range of ears affected by tinnitus was restricted for stimulation with noise signals at 1000, 2000 and 4000 Hz. The parameters of ΔFIT fitted to the loudness functions were increased in the whole frequency range of 500–4000 Hz, indicating that loudness scaling was not as reliable for normal hearing ears when influenced by tinnitus. Tinnitus masking was based on the finding that external sound could change tinnitus loudness. Our results showed that the loudness perception of external sound was influenced by tinnitus. This change in loudness perception seemed to be not restricted to the frequency range of the tinnitus.
    Notes: Zusammenfassung Die übliche spezielle audiologische Diagnostik bei Tinnitus liefert wenige Informationen darüber, wie sich bei Ohrgeräuschpatienten allgemein die Lautheitsempfindung mit Änderung des Schallpegels verhält. Mit Hilfe des Testmaterials der Würzburger-Hörfeld-Audiometrie zur kategoriellen Lautheitsskalierung sollte die Lautheitsempfindung normalhörender Tinnituspatienten – außerhalb der subjektiv empfundenen Tonhöhe des Ohrgeräusches – mit der von ohrgesunden Personen verglichen werden. Die Hörfeldskalierung erfolgte bei 20 normalhörenden Erwachsenen und 16 ebenfalls normalhörenden Probanden mit einem einseitigen und hochfrequenten Tinnitus für Schmal- bandrauschimpulse der Mittenfrequenzen 500, 1000, 2000 und 4000 Hz im Pegelbereich zwischen 20 und 90 dB HL. Normalhörende mit einem begleitenden Ohrgeräusch zeigten, für Stimuli der Mittenfrequenz 4000 Hz, im gesamten Pegelbereich systematisch leisere Skalierungsergebnisse. So zeigten die Isolautheitskurven für die Lautheitsempfindungen „mittellaut“ und „sehr laut“ eine Einschränkung des Dynamikbereichs bei 1000, 2000 und 4000 Hz. Im gesamten Frequenzbereich fielen die Skalierungsergebnisse bei den Probanden mit einem Tinnitus unsicherer aus. Von der Tinnitusmaskierung her ist es bekannt, daß externe Schallsignale die Tinnituswahrnehmung beeinflussen. Unsere Ergebnisse zeigen, daß ein Ohrgeräusch aber auch seinerseits mit der Lautheitswahrnehmung von Schallreizen interferiert. Der Tinnitus selbst scheint eine Art maskierende Wirkung auf das Hören auszuüben, indem es externen Schallreizen etwas von ihrer Lautheit nimmt. Die veränderte Lautheitswahrnehmung geht über den Tinnitusfrequenzbereich hinaus.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    HNO 46 (1998), S. 762-765 
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Aneurysma ; Mittelohrchirurgie ; Komplikationen ; Gefäßmißbildungen ; Paracentese ; Key words Intraperitoneal aneurisms ; Middle ear surgery ; Myringotomy ; Complication ; Vascular malformations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Aneurysms of the temporal part of the carotid artery are unusually rare. The literature contains only a few previous reports dealing with hemorrhage from such malformations. In the present case massive bleeding occurred from a right-sided intrapetrous aneurym after myringotomy, which was performed as treatment for bilateral secretory otitis media. Due to the absence of any specific symptoms and the masking effect of middle ear glue preoperative identification of the aneurysm was not possible. Subsequent angiography showed the large fusiform extension of the intrapetrous aneurysm as well as multiple intracranial aneurysms. Leakage from the aneurism was closed definitively with muscle, fascia lata and a gelatin-resorcin-formalin-glue (Cardial®). In order to apply the tissue patch the hypotympanic site of the aneurism was exposed using a posterior otosurgical approach. Due to extensive intracranial collateralization to the vertebral arteries bleeding persisted even after ligation of both carotid arteries. Temporary cardiac asystole was then induced to allow safe closure of the aneurysm. Following surgery the patient sustained loss of hearing in her ear and a partial peripheral facial palsy.
    Notes: Zusammenfassung Aneurysmen der petrösen A. carotis interna sind extrem selten. Die wenigen publizierten Fälle waren Zufallsbefunde und überwiegend durch schwere Hämorrhagien bei Ohroperationen oder tubogene Epistaxis gekennzeichnet. In dem vorliegenden Fall trat nach einer Parazentese, die wegen adenoidassoziierter Paukenergüsse durchgeführt wurde, eine massive Blutung aus einem fusiformen Aneurysma der A. carotis interna auf. Die neuroradiologische Diagnostik ergab multiple, weitere intrakranielle Aneurysmen. Das petröse Aneurysma wurde über einen otochirurgischen Zugang mittels eines speziellen Gefäßwandklebers (Cardial) in gezielt herbeigeführter Asystolie, die wegen eines ausgeprägten, intrakraniellen Kollateralkreislaufes erforderlich war, verschlossen. Es kam zu keinen neurologischen Defiziten, allerdings resultierten eine Taubheit und eine angedeutete Fazialisparese. Der Bericht erweitert die einschlägige Literatur um eigene Erfahrungen in der Diagnostik und Therapie des blutenden, petrösen Karotisaneurysmas.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...