Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Anatomy and embryology 199 (1999), S. 519-527 
    ISSN: 1432-0568
    Keywords: Key words Morphology ; Embryo culture ; Lipid droplet ; Development
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  The ultrastructure of bovine morulae and blastocysts developed from in vitro-matured and -fertilized oocytes in a serum-supplemented medium was compared with that of morulae and blastocysts collected non-surgically from superovulated cows. In the in vivo-derived morulae, two characteristic cells types could be identified by the electron-density of their cytoplasm and by their ultrastructural features. One type appeared light in color with low electron-dense cytoplasm. These cells were located in the peripheral layer of the cluster of blastomeres, possessed numerous cellular organelles such as mitochondria and Golgi apparatus and had microvilli projecting into the perivitelline space. The other cell type was distinguished by cytoplasm that stained more densely than that of the lighter-appearing cells. The darker-appearing cells generally possessed fewer organelles than the lighter cells, but many lysosome-like structures were present in the cytoplasm. The in vitro-developed morulae also contained two types of cells similar to those observed in the in vivo morulae. However, most of the in vitro-developed cells possessed numerous lipid droplets and contained fewer lysosome-like structures than the cells of the in vivo-derived morulae. The blastocysts, both in vivo and in vitro, showed a clear differentiation of trophoblast cells and inner cell mass (ICM)-cells. In the in vivo-derived blastocyst, the apical membrane of trophoblast cells was covered with large, numerous microvilli and well-developed junctional complexes were observed. Lipid droplets were present in the cytoplasm of trophoblast and ICM-cells but were not abundant. In vitro-developed blastocysts showed less well-developed junctional complexes between trophoblast cells, less well-developed apical microvilli on the trophoblast cells, and contained large numbers of lipid droplets. This accumulation of lipid droplets was higher in the trophoblast cells than in the ICM-cells. The zonae pellucidae of in vitro-developed embryos were thinner than that of the in vivo-derived embryos. This study demonstrates conspicuous differences in the ultrastructural features between the in vivo-derived and in vitro-developed embryos, suggesting that the ultrastructure may reflect the various physiological anomalies observed in previous studies.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1041
    Keywords: Key words Hypercholesterolaemia ; Pravastatin ; Mevalonate; cholesterol synthesis ; circadian rhythm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract In order to determine whether there is a difference in the effect of the hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase inhibitor pravastatin on cholesterol synthesis between the morning and the evening, we studied the 24-h profile of mevalonate in plasma and urine in 11 subjects with heterozygous familial hypercholesterolaemia. In study 1, eight subjects with familial hypercholesterolaemia took pravastatin (20 mg) once in the morning, and another 20-mg dose in the evening after a 1-week wash-out period. In study 2, five subjects with familial hypercholesterolaemia took pravastatin (20 mg per day) in the morning on 3 consecutive days and on 3 days in the evening after a 1 day wash-out. Plasma mevalonate concentrations were reduced at 9 h and 5 h after pravastatin administration in the morning and the evening, respectively. Urinary mevalonate excretion was significantly reduced at 4–8 h after pravastatin administration in the morning (51 vs 19 nmol ⋅h−1) and at 4–16 h after pravastatin administration in the evening (56 vs 27 nmol ⋅h−1). Daily urinary mevalonate excretion was equally and significantly reduced by pravastatin in the morning or evening. In conclusion, we found that morning and evening administration of pravastatin caused equal reductions in plasma and urinary mevalonate concentrations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1041
    Keywords: Hypercholesterolaemia ; Pravastatin ; Mevalonate ; cholesterol synthesis ; circadian rhythm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract In order to determine whether there is a difference in the effect of the hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase inhibitor pravastatin on cholesterol synthesis between the morning and the evening, we studied the 24-h profile of mevalonate in plasma and urine in 11 subjects with heterozygous familial hypercholesterolaemia. In study 1, eight subjects with familial hypercholesterolaemia took pravastatin (20 mg) once in the morning, and another 20-mg dose in the evening after a 1-week wash-out period. In study 2, five subjects with familial hypercholesterolaemia took pravastatin (20 mg per day) in the morning on 3 consecutive days and on 3 days in the evening after a 1 day wash-out. Plasma mevalonate concentrations were reduced at 9 h and 5 h after pravastatin administration in the morning and the evening, respectively. Urinary mevalonate excretion was significantly reduced at 4–8 h after pravastatin administration in the morning (51 vs 19 nmol · h−1) and at 4–16 h after pravastatin administration in the evening (56 vs 27 nmol · h−1). Daily urinary mevalonate excretion was equally and significantly reduced by pravastatin in the morning or evening. In conclusion, we found that morning and evening administration of pravastatin caused equal reductions in plasma and urinary mevalonate concentrations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    s.l. ; Stafa-Zurich, Switzerland
    Materials science forum Vol. 105-110 (Jan. 1992), p. 1745-1748 
    ISSN: 1662-9752
    Source: Scientific.Net: Materials Science & Technology / Trans Tech Publications Archiv 1984-2008
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0942-0940
    Keywords: Keywords: Anterior choroidal artery; peripheral aneurysm; intraventricular haemorrhage; choroid plexus cyst
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary This report describes a rare case of a distal anterior choroidal artery aneurysm which developed intraventricular haemorrhage without subarachnoid haemorrhage as shown on computerized tomographic (CT) scan. A 69-year-old hypertensive man suddenly became unconscious. An emergency CT scan showed a severe intraventricular haemorrhage and a small round low-dense lesion within the haematoma at the right trigone. The haematoma with obstructive hydrocephalus made the lateral ventricles larger on the right than on the left. CT scan could not detect any subarachnoid haemorrhage. Right interal carotid angiography revealed a saccular aneurysm at the plexal point of the right anterior choroidal artery. We approached the aneurysm and the small round lesion through the trigone via a right temporo-occipital corticotomy. We could clip the aneurysmal neck and remove the intraventricular haematoma and the papillary cystic mass (corresponding to the small round lesion on CT scan) totally in one sitting. Histological examination revealed the aneurysm to be a true one and the papillary cystic mass to be a choroid plexus cyst.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Molecular microbiology 10 (1993), S. 0 
    ISSN: 1365-2958
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Biology , Medicine
    Notes: We previously isolated two distinct Saccharomyces cerevisiae myo-inositol transporter genes, ITR1 and ITR2 (Nikawa et al., 1991). Here, we studied the regulation of their expression by measuring steady-state mRNA levels and β-galactosidase activities of lacZ fusion genes under different conditions. The results show that the expression of the two ITR genes is differently regulated: ITR1 was repressed by inositol and choline whereas ITR2 was constitutive. Deletion analysis of the ITR1 upstream region and comparison with the upstream regions of other genes involved in phospholipid synthesis indicate that the octamer sequence 5′-TTCACATG-3′ is important for the expression and inositol/choline regulation of the ITR1 gene.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of oral rehabilitation 20 (1993), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A new portable system for measuring nocturnal tooth contacts has been devised. This system was suitable for patients to take home and record tooth contacts by themselves. A micro photo sensor using optical fibres was applied to detect tooth contacts. The sensor and the target were accurately fixed to opposed molars, respectively on the same side, with removable metal attachments. Patients were instructed to set the attachment to their tooth each experimental night. In the present study, data was assembled for four or five nights in three subjects who were free of masticatory pain and dysfunction. Each subject showed an individual tooth contact pattern. It is suggested that this new system is useful and convenient for measuring nocturnal tooth contacts.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of oral rehabilitation 18 (1991), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The occlusal tooth contact patterns in patients with temporomandibular dysfunction and normal subjects were studied under a range of conditions using a newly devised radiotelemetry system. The patterns in the patient group were completely different from those in the control group. During rest or work, the patients showed higher values for total number and time of tooth contacts, as well as several contacts of extended duration. Moreover, many of the tooth contacts during swallowing were plural contacts in the patient group. These results suggest that patients with temporomandibular dysfunction exhibit increased tonus of jaw-closing muscles, which is probably due to occlusal disharmonies and psychological stress.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 26 (1999), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The purpose of this article is to review the literature concerning the ideal chewing pattern for best chewing performance. We conclude that at this time there is not one ideal chewing pattern which can be used clinically or in research to assess the health of the mastication apparatus nor to predict chewing performance. It is clear that human masticatory behaviour is one of the most complex human behaviours. Chewing is under the control of the central pattern generator located in the brain stem but is influenced by dental and temporomandibular joint morphology. The most important portion of the chewing cycle is the area entering and leaving the intercuspal position where gliding contacts occur. Maximal chewing capability will likely occur when the chewing pattern follows the dental anatomy unique to the individual. The chewing cycle appears to increase the lateral component of its movement when increased chewing efficiency is required. These situations include increased hardness or the size of bolus, the position of the bolus and the results of the proceeding chewing stroke. The chewing pattern for any one cycle is influenced by a number of factors, thus it is not surprising that the question of the ideal chewing pattern remains unresolved.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of oral rehabilitation 23 (1996), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary A new system for measuring threedimensional deformation has been developed. The main components of the system are a fixed TV camera and vertically scanning projectors. The advantages of the system are: (1) since there is no mechanical contact between the object and the sensing unit, hardness and form of the object do not have to be considered; (2) the system does not need any precise geometry except for the reproducibility of the vertical scanning stage; (3) the time required for one measurement is extremely short; and (4) the system is not expensive. From the basic experiments for testing accuracy, this system has about ± 30 μm range deviation against 1000 μm deformation of the object. The system has been applied to investigate the influence of various impression procedures for a removable partial denture on the displacement of the simulated soft mucosal tissue. It is revealed that deformation forms are expressed precisely. Our results suggest that this measurement system is quite useful for research in dentistry and that it could be widely applied.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...