Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 76 (1994), S. 4705-4712 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Carrier concentration and mobility of unintentionally doped InP layers, grown directly on Si using metal-organic vapor-phase epitaxy, have been studied. The formation of antiphase domains (APDs) was found to depend on annealing of the Si substrate in an AsH3 flow prior to epitaxial growth. Dislocation densities determined by the wet chemical delineation technique were (8±1)×107 cm−3, seemingly uncorrelated to APDs in the layers. In addition to a shallow donor and a compensating acceptor, a deep donor was observed affecting the temperature dependence of the free-electron concentration between 77 and 300 K. The electron mobility in this temperature range could be described in terms of the scattering mechanisms which are dominant in homoepitaxial InP, namely, scattering due to polar optical phonons, to ionized impurities, and to space charges. Electron scattering due to either of these mechanisms was strongly influenced by the occurrence of antiphase boundaries (APBs). The space-charge density as well as the degree of compensation of the epitaxial layers increases with the density of APBs. Degraded 300 K mobilities were obtained indicating the effect of local stress at the APB.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 101 (1994), S. 10481-10484 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: We calculate the modifications of the unimolecular rate constants for free metallic clusters due to thermally exited electronic degrees of freedom. The effect is essentially taken into account by substituting Helmholtz's free energy of the electronic system for the ground state energy. The activation energy pertaining to the electronic ground states of the mother and daughter cluster is then replaced by the first difference in Helmholtz's free energy. © 1994 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary. The clinical significance of placental perforation and bloodstained amniotic fluid was studied in a group of 7238 Danish women undergoing mid-trimester amniocentesis for prenatal diagnosis under ultrasound guidance. The risk of spontaneous abortion was significantly increased both in pregnancies where the placenta was perforated and in those with blood-stained amniotic fluid. The risk estimate nearly doubled after placental perforation and more than doubled with a bloody tap. It is concluded that for women at relatively low risk of a fetal genetic abnormality, the indication of the amniocentesis should be reconsidered if a placental perforation is unavoidable.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 65 (1994), S. 2615-2622 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A computer controlled acquisition and evaluation system for electrostatic probes is presented. Fully automatic evaluation of the probe characteristics yields electron temperature, plasma potential, and density during the recording. Two-dimensional probe positioning is accomplished with stepping motors. The system is characterized by 12-bit probe current resolution and extremely wide probe voltage range (±130 V). It is tested in a collisionless argon magnetoplasma and compared to standard wave diagnostic techniques for magnetized plasmas, i.e., the resonance cone technique. The influence of the probe radius on the electron current in a magnetized plasma is studied experimentally. The two techniques yield identical density and temperature values within 20% accuracy and therefore show the reliable applicability of the automatic evaluation system.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 59 (1988), S. 1451-1456 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: By combining the time-of-flight or LIDAR principle with a Thomson backscatter diagnostic, spatial profiles of the electron temperature and density are measured in a magnetically confined fusion plasma. This technique was realized for the first time on the JET tokamak. A ruby laser (3-J pulse energy, 300-ps pulse duration, 0.5-Hz repetition rate) together with a 700-MHz bandwidth detection and registration system yields a spatial resolution of about 12 cm. A spectrometer with six channels in the wavelength range 400–800 nm gives a dynamic range of the temperature measurements of 0.3–20 keV. The stray light problem in the backscatter geometry is overcome by spectral discrimination and gating of the photomultipliers. A ruby filter in the spectral channel containing the laser wavelength allows calibration of the vignetting along the line of sight by means of Raman scattering, enabling the measurement of density profiles. The low level of background signal due to the short integration time for a single spatial point yields low statistical errors (ΔTe /Te ≈6%, Δne /ne ≈4% at Te =6 keV, ne =3×1019 m−3 ). Goodness-of-fit tests indicate that the systematic errors are within the same limits. The system is described and examples of measurements are given.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 60 (1989), S. 3265-3269 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The electronics for the microchannel plate photomultiplier tubes used in the LIDAR (Light Detection and Ranging) Thomson scattering diagnostic on the JET tokamak are described. It is shown how the microchannel plate photomultiplier tubes are gated with a very small coupling between gate signal and output, and how ≈300 V transient pulses with rise times of 230 ps are clipped to safe levels of ≈40 V.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The design of a photoemission microprobe beamline at the MAX laboratory is presented. The beamline will utilize the radiation from a 26 period undulator on the 550-MeV MAX storage ring. The beamline will be capable of providing about 1010 photons/s of monochromatized radiation (bandwidth better than 0.25 eV) in the energy range of 20 to 150 eV focused into a submicrometer focal spot. It will be used for scanning photoemission experiments with a lateral resolution better than 1 μm. The optical system is comprised of a plane-grating monochromator with a Kirkpatrick–Baez objective and a specially designed ellipsoidal focusing mirror.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    International journal of food science & technology 21 (1986), S. 0 
    ISSN: 1365-2621
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Anthocyanin extraction from elderberry pomace is improved by mechanical disintegration and use of aqueous HCl in place of acidified ethanol as extractant, with pH being important in determining extractant effectiveness. Extraction at low solvent:pomace ratios gives extracts of higher concentration and lower volume, but with reduced efficiency. Enzyme pretreatments do not improve extractability from exten-sively crushed pomace, and if of extended duration, can result in anthocyanin break-down. Vacuum evaporation of extracts gave little loss of anthocyanins, and combined with freeze drying, produced materials with high anthocyanin retention.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Scandinavian journal of immunology 33 (1991), S. 0 
    ISSN: 1365-3083
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The antibody response to Borrelia (B.) burgdorferi, and to measles virus as control antigen, was analysed by agarose isoelectric focusing (AIF) and immunoblot of joint fluid and serum from 10 patients with Lyme arthritis and 10 controls with rheumatoid arthritis. Among the Lyme arthritis patients, six had oligoclonal anti-B, burgdorferi IgG antibody bands in joint fluid and Corresponding serum, one patient had oligoclonal antibody bands in joint fluid only and also an elevated B. burgdorferi IgG in joint fluid to serum antibody ratio as evidence of intra-joint production of specific antibodies, and the remaining three patients were negative for oligoclonal-specific antibody bands. Absorption with B. burgdorferi imagen confirmed the specificity of the ofigoclonal antibody bands. They comigrated only partially on AIF with oligoclonal bands of total IgG and the specificity of most oligoclonal IgG in joint fluid and serum in Lyme arthritis remains undefined. Among the controls, no anti-B, burgdorferi IgG antibodies were detected by AIF and immunoblot. Instead. 9 of the 10 rheumatoid arthritis patients had oligoclonal anti-measles IgG antibody bands which were restricted to the joint fluid in three of them, indicating local production. We conclude that Lyme arthritis is often accompanied by an oligoclonal specific antibody response in joint fluid and serum simultaneously, and occasionally by intrasynovial synthesis of oligoclonal-specific antibodies.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Scandinavian journal of immunology 37 (1993), S. 0 
    ISSN: 1365-3083
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Pre- and post-treatment (up to 3–26 months after antibiotic therapy) humoral immune responses were investigated in five neuroborreliosis patients. Anti-Borrelia (B.) burgdorferi IgG and IgM antibodies in CSF and serum were quantitated by capture ELISA. Agarose gel isoelectric focusing (AIF) and protein blotting were used to detect oligoclonal IgG and IgM bands as well as oligoclonal anti-B. burgdorferi IgG and IgM antibodies. These latter components were visualized by transfer to antigen-coated membranes (immunoblot) and immunoenzymatic staining. By ELISA, intrathecal anti-B. burgdorferi IgG and IgM antibody synthesis was detected in all initial specimens and continued 3–26 months after antibiotic therapy in four and three cases, respectively. AIF with protein blotting showed oligoclonal bands of total IgG as well as total IgM in the initial CSF specimens of all patients and persistence of such components occurred in four and five cases, respectively. By AIF and immunoblot, oligoclonal anti-B. burgdorferi IgG and IgM antibody bands could be detected in the CSF of every patient. IgG antibody bands were present in all initial CSF samples. The first specimen of one patient was negative for IgM antibody bands but such components appeared 3 weeks later. Oligoclonal CSF anti-B. burgdorferi IgG antibody components persisted over the entire follow-up periods in all but one case where they disappeared 6 weeks after treatment. The oligoclonal IgM antibodies in CSF vanished in two cases (after being present up to 4 and 11 months after antibiotic therapy) while they persisted over the entire (3–6 months after antibiotic therapy) follow-up periods in three cases. The specificity of the IgM antibody immunoblot technique was corroborated by control experiments, including antibody absorption studies and use of 41 kDa flagellar antigen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...