Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (3)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 26 (1984), S. 491-498 
    ISSN: 1432-1041
    Keywords: theophylline ; computer simulation ; pharmacokinetics ; single-point dose prediction ; nomogram
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary A dosage prediction method to estimate theophylline clearance and dose requirement was evaluated in 22 outpatients with partly reversible obstructive airways disease. The steady state theophylline dose required to achieve a target concentration (Css) was predicted using a single serum theophylline determination 8 h after a single oral test dose. In 17 nonsmoking patients a mean absolute deviation of 8.2% (range 0.0–21.7%) between predicted and observed Css was found, and in 5 smoking patients the mean deviation was 34.0% (range 2.2–53.8%). In 17 healthy smokers the single-point method was found to predict theophylline clearance at a sampling time of 8 h with a prediction error of 11.3 (range 0.8–25.3%) compared to the clearance determination using the area under the curve. In addition, a numerical simulation program to assess the influence of absorption, elimination and sampling time on predictive accuracy showed that the method could be successfully applied to a patient population with elimination rate constants between 0.07 1/h and 0.25 1/h, allowing a mean prediction error of 15%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Conclusion All of the immunoassays tested were rapid and easy to perform. The precision of these tests was adequate and the results were comparable with those obtained by HPLC. The EMIT correlated best with HPLC and showed a high specificity. Normally encountered levels of other xanthines or uric acids apparently do not interfere with this assay.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 317 (1984), S. 677-677 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Conclusion Because of its high specifity, accuracy and precision the described HPLC method appears to be very useful for establishing the accuracy of other procedures in comparative studies or as confirmation analysis in cases of suspected interference. For routine monitoring of serum theophylline concentrations this procedure is less suitable due to the relatively short life time of the column. Further studies are in progress to develop a candidate reference method for the determination of theophylline based on this procedure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...