Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Psychopharmacology 102 (1990), S. 379-382 
    ISSN: 1432-2072
    Keywords: Paroxetine ; Amitriptyline ; Electrocardiogram ; Blood pressure ; Systolic time intervals ; Plasma drug concentration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In a double-blind clinical study, electrocardiogram, blood pressure and systolic time intervals were measured in 40 depressive patients treated with either paroxetine (30 mg/day) or amitriptyline (150 mg/day) for 6 weeks. While amitriptyline significantly increased the heart rate, the QTc interval and the PEP/LVET ratio, paroxetine did not alter any of the cardiovascular parameters measured.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1434-601X
    Keywords: 25.70.-z ; 25.70.Lm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Events with 2, 3 and 4 heavy-fragments (A≧20) have been detected in the reactions100Mo+100Mo atE/A =18.7, 23.7 MeV and120Sn+120Sn atE/A=18.4 MeV. The experiments were performed with an array of 12 detectors which together covered a large fraction of the forward hemisphere and allowed a high detection efficiency for these events. Masses and energies of all fragments have been reconstructed by means of an improved version of the kinematic coincidence method. The probabilitiesP 3 andP 4 of producing 3- and 4-body events were found to depend mainly on the dissipated energy rather than on the bombarding energy, thus indicating that their origin lies more in the decay properties of the excited fragments than in the dynamics of the interaction. Emission of light particles from the composite system is shown to become more relevant with increasing bombarding energy and may explain the drop of theP 3 andP 4 curves at high energy losses. Small deviations of theP 3 andP 4 curves at 23.7A · MeV from those at lower bombarding energies were used to estimate the amount of a possible pre-equilibrium light particle emission as a function of impact parameter.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...