Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of sol gel science and technology 8 (1997), S. 547-552 
    ISSN: 1573-4846
    Keywords: silicon alkoxide ; phase separation ; double pore structure ; liquid chromatography ; Van Deemter equation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Silica gels retaining double pore structure in the size ranges of micrometer and nanometer have been applied to the rod-shaped monolithic column for liquid chromatography. The macropore structure was designed by controlling the phase separation process induced by the hydrolysis and polycondensation of alkoxysilane, whereas the mesopore structure was tailored by the solvent exchange treatments on wet gels. The size exclusion chromatograms on polystyrene standards exhibited almost similar features for octadecyl-modified rod and conventional packed beads columns. The dependence of plate height on the velocity of mobile phase determined for amylbenzene was by far weaker in the rod column than in the packed beads column, suggesting that additional geometrical factors should be considered in describing the separation mechanism in the rod column.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of sol gel science and technology 13 (1998), S. 163-169 
    ISSN: 1573-4846
    Keywords: silica gels ; phase separation ; pore size distribution ; liquid chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Utilizing the concurrence of polymerization-induced phase separation and sol-gel transition in the hydrolytic polycondensation of alkoxysilanes, a well-defined macroporous structure is formed in a monolithic wet gel. By exchanging the fluid phase of the wet gel with an appropriate external solution, the nanometer-range structure of the wet gel can be reorganized into structures with larger median pore size essentially without affecting the macroporous framework. The double-pore structure thus prepared is characterized by open pores distributed in discrete size ranges of micrometers and nanometers. A new type of chromatographic column (silica rod) has been developed using monolithic double-pore silica instead of packed spherical gel particles. Typical silica rod columns had significantly reduced pressure drops and improved analytical efficiencies which do not deteriorate even at higher sample flow rates, both arising from a greater macropore volume than particle packed columns.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of sol gel science and technology 8 (1997), S. 547-552 
    ISSN: 1573-4846
    Keywords: silicon alkoxide ; phase separation ; double pore structure ; liquid chromatography ; Van Deemter equation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Silica gels retaining double pore structure in the size ranges of micrometer and nanometer have been applied to the rod-shaped monolithic column for liquid chromatography. The macropore structure was designed by controlling the phase separation process induced by the hydrolysis and polycondensation of alkoxysilane, whereas the mesopore structure was tailored by the solvent exchange treatments on wet gels. The size exclusion chromatograms on polystyrene standards exhibited almost similar features for octadecyl-modified rod and conventional packed beads columns. The dependence of plate height on the velocity of mobile phase determined for amylbenzene was by far weaker in the rod column than in the packed beads column, suggesting that additional geometrical factors should be considered in describing the separation mechanism in the rod column.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 22 (1980), S. 779-797 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A theoretical method for predicting the elution profile of a pulse response in an immobilized-enzyme column is proposed. The method is based on a mass balance model, which is extensively used in gel chromatography. To test the method, a pulse of sucrose solution was applied to a column of spherical acrylamide gel in which was entrapped invertase from yeast, and it was eluted with 0.05M acetate buffer at pH 5.0. The elution curves of the substrate and the product were in fairly good agreement with the theoretically calculated ones. The method was extended to the system of reversible as well consecutive reactions.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 1 (1968), S. 61-70 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The mass spectral fragmentations of stereoisomeric cyclohexane-1,2-diols, p-menthane-2,3-diols, 1-hydroxycarvomenthols and 4-hydroxymenthols are discussed.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Hydroxyapatite induction by a synthesized pure silica hydrogel was examined in various simulated body fluids (SBFs) having different magnesium, calcium, and phosphate ion concentrations as well as pH values. The silica hydrogel generated biologically active apatite on its surface by taking up calcium and phosphorous ionic groups from a surrounding SBF that was prepared to emulate the human plasma in inorganic composition. The induction period for apatite nucleation on the surface of the silica was largely decreased with the addition of a small amount of the calcium or phosphate ions to the SBF and with an increase in pH, but increased with the addition of magnesium ion. Bioactivity of bioactive materials like Bioglass® and glass-ceramic A-W was well interpreted in terms of the rate of apatite formation reflected in these results. Moreover, the results provide the basic knowledge for designing new bioactive materials. © 1993 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 93-99 
    ISSN: 0935-6304
    Keywords: HPLC ; monolithic column ; silica rod column ; fast separations ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The application of a new silica-based, monolithic-type HPLC-column for fast separations is presented. The column is prepared according to a new sol-gel process, which is based on the hydrolysis and polycondensation of alkoxysilanes in the presence of water soluble polymers. The method leads to “rods” made of a single piece of porous silica with a defined pore structure, i. e. macro- and mesopores. The main feature of silica rod columns is a higher total porosity, about 15% higher than of conventional particulate HPLC columns. The resulting column pressure drop is therefore much lower, allowing operation at higher flow rates including flow gradients. Consequently, HPLC analysis can be performed much faster, as it is demonstrated by various applications.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für die chemische Industrie 76 (1964), S. 792-793 
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...