Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Radioimmunoassay  (2)
  • Asymmetric catalysis  (1)
  • Computed tomography  (1)
  • 1
    ISSN: 0040-4020
    Keywords: Allylic silane ; Allylic stannane ; Asymmetric catalysis ; Binaphthol-derived titanium dihalide ; Carbonyl-addition reaction ; Carbonyl-ene reaction ; Chiral titanium complex ; Diastereocontrol ; Enantiocontrol ; Glyoxylate
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Clinica Chimica Acta 158 (1986), S. 293-299 
    ISSN: 0009-8981
    Keywords: Diabetes mellitus ; Glucitollysine ; Nonenzymatically glycated albumin ; Radioimmunoassay
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1920
    Keywords: Dural arteriovenous malformation ; Posterior cranial fossa ; Varix ; Computed tomography ; Magnetic resonance imaging ; Thrombosed aneurysm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Dural arteriovenous malformations (AVMs) in the posterior cranial fossa are relatively infrequent. Intradural haemorrhage is one of their specific complications. Angiographic demonstration of varices or aneurysmal structures is one of the hallmarks of severe cases. We report a patient with posterior cranial fossa dural AVM associated with a varix mimicking a thrombosed aneurysm on CT and MRI. Internal carotid and vertebral angiography failed to demonstrate an aneurysm, but external carotid injection revealed a dural AVM affecting the sigmoid sinus, and a varix. The AVM was completely eliminated by embolization. When a dural AVM is suspected clinically selctive angiography should be performed to confirm the diagnosis even when CT or MRI do not show dilated vessels.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-0428
    Keywords: Radioimmunoassay ; glycation ; HbA 1c glucose ; glucitollysine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A competitive radioimmunoassay for the quantitative determination of glycated haemoglobin was developed. The antiserum, obtained by immunizing guinea pigs with reduced glycated human albumin, was capable of identifying and quantitating the glucitollysine residues of glycated Hb after reduction with sodium borohydride. To simplify the sample preparation we introduced trichloroacetic acid precipitation to remove unreacted sodium borohydride instead of using dialysis or gel filtration. Using this procedure, our radioimmunoassay became relatively simple and provided satisfactory within- and between-run (1.3–2.8% and 1.9–5.4% coefficient of variation, respectively). The radioimmunoassay method was compared to the measurement of HbA 1c by high performance liquid chromatography which is the most widely used method for quantitating glycated Hb. For this purpose glycated Hb was measured in normal glucose tolerance, impaired glucose tolerance, and diabetes mellitus groups based on WHO criteria. Both assays were able to discriminate between the normal and diabetic groups. In addition, while the determination of glycated Hb by the radioimmunoassay method was able to clearly discriminate between the normal and impaired glucose tolerance groups, the determination of HbA 1c by the high performance liquid chromatography method failed to discriminate between these two groups. Moreover, 15 of the 20 impaired glucose tolerance patients exceeded the upper normal range (mean normal values + 2 SD) in radioimmunoassay. But all 20 patients with impaired glucose tolerance were within the upper normal range in HbA 1c values. These results demonstrate that the measurement of glycated Hb by radioimmunoassay is more sensitive than the measurement of HbA 1c by high performance liquid chromatography since it can discriminate between the normal and impaired glucose tolerance groups.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...