Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 19 (1981), S. 209-212 
    ISSN: 1432-1041
    Keywords: prednisone ; prednisolone ; azathioprine ; 11 β-hydroxydehydrogenase ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Clinical and pharmacokinetic observations suggest that azathioprine may diminish the plasma level of prednisolone. To study the extent of this possible interaction, and to define the underlying mechanism, total and unbound prednisolone and total prednisone concentrations were assessed in 11 subjects following an oral dose of prednisone once with and once without concomitant oral administration of azathioprine. Azathioprine did not affect the area under the plasma concentration-time curve of total and unbound prednisolone; furthermore, the interconversion of prednisone into prednisolone was not influenced by azathioprine.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 26 (1984), S. 505-511 
    ISSN: 1432-1041
    Keywords: prednisolone ; prednisone ; oral contraceptives ; 6β-hydroxylase ; transcortin ; protein-binding ; steroid metabolism ; pharmacokinetics ; drug interaction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The oestrogenic component of oral contraceptives affects the activity of liver enzymes and the concentrations of plasma proteins implicated in steroid metabolism and transport. The present study was designed to determine these effects on the kinetics of prednisone and prednisolone. After an oral dose of prednisone, women on oral contraceptive steroids (n=10) had higher mean (±SD) area under the plasma concentration versus time curves of total (428±67 µg/ml/min vs 188±28 µg/ml/min, p〈0.001) and unbound prednisolone (64±10 µg/ml/min vs 41±10 µg/ml/min, p〈0.001) than women not taking oral contraceptive steroids (n=10). The differences were attributable to a lower non-renal clearance of prednisolone and to a higher apparent systemic availability of the drug in contraceptive users than in the controls. The affinity of albumin and transcortin for prednisolone was lower in women on oral contraceptives than in controls (p〈0.001). Thus, altered kinetics and protein binding may account for the known increase in glucocorticoid efficacy by oestrogens.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1041
    Keywords: prednisolone ; hydrocortisone ; cushingoid syndrome ; pharmacokinetics ; renal transplant ; oral disease
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary To establish if the appearance of cushingoid side effects in patients taking exogenous glucocorticoids is related to the disposition and metabolism of these steroids and endogenous hydrocortisone, 15 stable renal transplant patients and 12 patients treated with prednisone for oral mucocutaneous vesiculo-erosive diseases were investigated. All 27 patients were given their usual prednisone dose orally on one occasion, and 24 were given the same amount of prednisolone intravenously on another occasion. Following dosing, plasma samples were obtained for determination of the areas under the plasma concentration time curves of total prednisolone, prednisone and hydrocortisone by high performance liquid chromatography, and of unbound prednisolone by equilibrium dialysis. The bioavailability of prednisone, the interconversion of prednisone into prednisolone, the clearance of total and unbound prednisolone, the prednisolone binding capacity of albumin and transcortin, and the affinity of albumin for prednisolone did not differ between the 14 patients without cushingoid side effects and the 13 cushingoid patients. Compared to those who had cushingoid features, patients who developed no side effects had a higher affinity constant for prednisolone binding to transcortin − 2.04±0.27 × 107 L/M vs. 1.34±0.16×107 (X±SE;P〈0.05), more frequently exhibited peak hydrocortisone levels within the normal range (6/14 vs 1/13), more often had measurable (〉10ng/ml) hydrocortisone in the plasma samples collected during the kinetic studies (123/291 vs 74/325;P〈0.001) and had higher areas under the plasma concentration time curve of hydrocortisone (median, range), i.e. 8081 ng/ml · min (0–21 637 ng/ml · min) vs 386 ng/ml · min (0–16 329 ng/ml · min;P〈0.005). The data suggest that endogenous hydrocortisone production is not as suppressed in patients with visible cushingoid signs as in noncushingoid patients, and that there is no significant difference in the pharmacokinetics of exogenous glucocorticoids between patients with and without cushingoid side effects.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1041
    Keywords: cefoperazone ; peritoneal dialysis ; pharmacokinetics ; terminal renal failure ; peritonitis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of cefoperazone after i.p. and/or i.v. administration were studied in 12 CAPD patients. After i.v. injection, the plasma half-life was 2.65±0.4 h, the total clearance amounting to 70.1±19.2 ml/min. Peritoneal clearance was calculated to be 6.9±1 ml/min. After peritoneal instillation, the bioavailability was 63.9±5%. After repeated i.p. administration, no accumulation of the drug in the body was observed. Thus, cefoperazone can be safely administered for the treatment of peritonitis in CAPD patients.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 36 (1989), S. 389-393 
    ISSN: 1432-1041
    Keywords: ornidazole ; haemodialysis ; pharmacokinetics ; renal function ; metabolism ; urine concentration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of ornidazole was studied in 6 patients treated by haemodialysis and in 8 subjects with a creatinine clearance between 4 and 99 ml/min × 1.73 m2. Blood and urine collections were performed for 72 h after i.v. and oral administration of 1.0 g ornidazole. Total body clearance, half-life, volume of distribution and systemic availability were independent of renal function and did not differ from previously reported values in normal volunteers. The haemodialysis clearance of ornidazole was 〉100% higher than the total body clearance. The renal clearance of ornidazole accounted for less than 7% of the total body clearance. The percentage of the dose of ornidazole recovered in urine as parent compound or as the biologically active metabolites [α-(chloromethyl)-2 hydroxymethyl-5 nitroimidazole-1 ethanol and 3-(2 methyl-5 nitroimidazole-1-yl)1,2 propanediol] decreased linearly with decreasing renal function. Although the sum of those three compounds recovered in urine accounted for less than 10% of the total dose of ornidazole administered, they yielded therapeutic concentrations (〉4 µg/ml) in urine over 24 h after dosing. Due to the peculiar pharmacokinetic behaviour of ornidazole, i.e. high haemodialysis clearance in the absence of significant renal clearance, no dosage adjustment is necessary while renal function declines, but an increased dose is mandatory while patients are on dialysis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 29 (1986), S. 697-701 
    ISSN: 1432-1041
    Keywords: tenoxicam ; renal insufficiency ; non-steroidal antiinflammatory agents ; protein binding ; metabolism ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of tenoxicam after a single oral dose of 20 mg has been studied in 12 patients with various degrees of decreased renal function. Unchanged tenoxicam and its 5′OH-metabolite in plasma and urine were determined by HPLC. The mean areas under the plasma concentration-time curve (138±53 µg/ml·h) and terminal half-lives in patients with impaired renal function did not differ from values previously reported in normal volunteers, nor did the peak concentration of tenoxicam. The half-life of 5′OH-tenoxicam and unchanged tenoxicam where the same. The urinary excretion of 5′OH-tenoxicam fell with decreasing renal function. Thus no dosage adjustment should be necessary and the usual daily dose of tenoxicam may be administered once daily also to patients with renal failure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 11 (1995), S. 191-198 
    ISSN: 1069-8299
    Keywords: triangulations ; mesh relaxation ; computational geometry ; planar mesh generation ; Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: Recent advances in planar mesh generation of arbitrary domains incorporate methods for placing points as well as connecting them into a triangulation. Postprocessing techniques such as Laplacian smoothing and mesh relaxation enhance the shape of triangles in these meshes but do not address the construction of meshes near boundaries or provide a criterion to determine the number of interior points of the initial triangulation. The paper addresses these issues by investigating the construction of degree-6 triangulations, the primary goal of the mesh relaxation method.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 36 (1993), S. 303-320 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: An efficient solution procedure for elasto-plastic analysis of Reissner-Mindlin plates has been proposed in this work. The main ingredients which render efficiency are: what appears to be an optimally tuned four-node plate element with assumed shear strains and incompatible bending modes; an elasto-plastic constitutive model given directly in terms of stress resultants; and efficient computation of plastic flow which simplifies to a solution of a single scalar equation and remaining state update computation. The performance of the element has been proved very satisfying in both elastic singularity-dominated and elasto-plastic problems.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 36 (1993), S. 3239-3258 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: We discuss both linear and geometrically non-linear finite element analysis of elastic beams, taking into account the shear deformation. In linear analysis, a novel shallow beam element formulaton is consistently derived, and the end result is more suitable for the finite element implementation than earlier attempts. The element is very resourceful for an explanation of membrane and shear locking phenomena and exploration of their possible remedies. In addition, it sheds some light on locking phenomena in non-linear analysis. In non-linear analysis, we discuss the finite element implementation of the finite strain beam theory of Reissner.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 31 (1991), S. 1121-1133 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: Given a list of points defining a domain boundary, a three-stage process is often used to triangulate a domain. First, an appropriate distribution of interior points is generated. Next the points are connected to form triangles. And, finally, the connectivity data are used to reposition the interior points using the Laplacian smoothing technique, thereby usually improving the shapes of the shapes of the triangles. This paper describes a new techniques for mesh improvement - adjusting the connection structure during the second stage of this process. The new scheme, which we call mesh relaxation, consists of a procedure for iteratively making the mesh topology more regular by edge swapping. For each interior edge, a relaxation index is computed that depends on the degrees of its end points and adjacent points. Any edge for which this index exceed a prescribed threshold will be swapped, i.e. replaced by a new edge connecting the adjacent points of the original edge. After all edge swaps are completed, Laplacian smoothing is applied to the mesh. Example show that, when the mesh point density varies smoothly and due care is taken in the vicinity of the boundary, mesh relaxation can dramatically increase the regularity of the mesh and produce improve triangle shapes.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...