Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-2161
    Keywords: Key words Femoral torsion ; Torsional difference ; Ultrasound ; Femoral fractures ; Anterior condylar line
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Objective. A torsional difference of more than 15° is found in up to 30% of patients following closed intramedullary nailing of femoral fractures. The diagnosis is usually established postoperatively by computed tomography. A torsional deformity of more than 15° should be corrected by early derotation. In order to enable an intraoperative control and possible correction to avoid a second operation for the patient, a new ultrasound-based method suitable for the intraoperative setting has been developed, using the anterior condylar line as a distal reference line. Design and patients. In a prospective study the torsional difference after closed intramedullary nailing of femoral fractures was measured postoperatively by ultrasound in 32 patients and compared with standard CT readings. Results. Torsional differences measured by ultrasound and CT showed a high correlation (r=0.8) and a median difference of less than ±3°. Conclusions. By the introduction of the anterior condylar line as a distal reference line femoral torsion can accurately be assessed by ultrasound in a position required for intraoperative control and possible correction.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1352-8661
    Keywords: magnetic resonance imaging ; surface coils ; MR-imaging technology ; tissue characterization ; skin ; wrist ; finger ; Achilles tendon
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics
    Notes: Abstract To investigate the application of a mini-coil surface system for high-resolution MRI, 60 volunteers were examined in a 1.5-T whole-body scanner. Two replaceable probe heads were available: a circular 2.5-cm coil and a quadratic 5-cm coil, both of which were placed directly on the skin. The skin layers, Achilles tendon and finger joints were examined with the 2.5-cm coil and a FOV of 25 × 25 mm2. A matrix of 256 × 256 pixels resulted in a pixel size of 0.098 × 0.098 mm2. For imaging of the carpal tunnel, the 5-cm coil was used in transverse orientation. The FOV was 50 × 50 mm2 so that a matrix of 256 × 256 pixels led to a pixel size of 0.195 × 0.195 mm2. The resulting spatial resolution permitted visualization of the epidermis, dermis and subcutis, resulting in clear definition of anatomical detail of the musculoskeletal system. MRI measurement of skin-layer thickness did not correlate with histometric data (p〈0.05). This discrepancy was due in part to shrinkage of the tumor specimen on histologic preparation. Other causes include the motion artifacts and the limited accuracy of determining thickness on the MRI display unit.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...