    ISSN: 1432-2161
    Keywords: Key words Acetabular labrum ; Magnetic resonance imaging ; hip ; Gadolinium ; Traction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Objective. The objective of this study was to evaluate the effects of continuous leg traction on contrast-enhanced MR imaging of the hip joint and to determine whether MR imaging under these conditions is useful for demonstrating acetabular labral tears. Design and patients. Nineteen hips underwent MR imaging with a T1-weighted spin-echo sequence, followed by MR imaging under continuous leg traction after intravenous injection of gadolinium-DTPA. Joint fluid enhancement and labral contour detection were evaluated. Eleven hips had labral tears shown by conventional arthrography, arthroscopy and macroscopic surgical findings. Assessment of labral tears by MR imaging was correlated with the diagnosis based on these standard techniques. Results and conclusions. Joint fluid enhancement was obtained in all hips at 30 min after injection. Superior and inferior labral surfaces were completely delineated in 1 hip on the unenhanced MR images, and in 7 and 13 hips, respectively, on the enhanced images under traction. The enhanced images under traction depicted 9 of the 11 labral tears. Comparison between the unenhanced image and the enhanced image under traction avoided mistaking undercutting of the labrum for a tear in 4 hips. Contrast-enhanced MR imaging under traction was valuable for detecting labral tears non-invasively and without radiation. Follow-up examinations using this method in patients with acetabular dysplasia can help to clarify the natural course of labral disorders and enable better treatment planning.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2161
    Keywords: Key words Elbow ; Ulnar collateral ligament ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Objective. The purpose of this study was to evaluate ulnar collateral ligament (UCL) injury of the elbow in throwing athletes by MRI and MR arthrography. Design. Ten elbows of throwing athletes were examined on both plain MRI and MR saline arthrography and the injuries subsequently surgically proven. Spin-echo (SE) T1-weighted and fast SE T2-weighted coronal images were obtained. Results. The UCL was unclear in all ten cases on T1-weighted MRI. In five cases an avulsion fracture was also found on T1-weighted MRI. On T2-weighted MRI, abnormal high-intensity areas were identified in or around the UCL. On T2-weighted MR arthrography images, extracapsular high-intensity areas, which represent extracapsular leakage, were found in four of five cases with avulsion fracture. At surgery, all these four cases showed avulsion fractures with instability; the other case had a fracture but it was stable and adherent to the humerus. On T2-weighted MR arthrography images, an extracapsular high-intensity area was found in one of the five cases without avulsion fracture. At surgery this patient had a complete tear of the UCL itself. Conclusion. MR arthrography provided additional information for evaluating the degree of UCL injury.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 1 (1968), S. 61-70 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The mass spectral fragmentations of stereoisomeric cyclohexane-1,2-diols, p-menthane-2,3-diols, 1-hydroxycarvomenthols and 4-hydroxymenthols are discussed.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 93-99 
    ISSN: 0935-6304
    Keywords: HPLC ; monolithic column ; silica rod column ; fast separations ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The application of a new silica-based, monolithic-type HPLC-column for fast separations is presented. The column is prepared according to a new sol-gel process, which is based on the hydrolysis and polycondensation of alkoxysilanes in the presence of water soluble polymers. The method leads to “rods” made of a single piece of porous silica with a defined pore structure, i. e. macro- and mesopores. The main feature of silica rod columns is a higher total porosity, about 15% higher than of conventional particulate HPLC columns. The resulting column pressure drop is therefore much lower, allowing operation at higher flow rates including flow gradients. Consequently, HPLC analysis can be performed much faster, as it is demonstrated by various applications.