Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1459
    Keywords: Key words Multi-parametric ; Multiple sclerosis ; Magnetic ; resonance imaging ; Lesion volume ; Clinico-radiological correlation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Magnetic resonance imaging (MRI) is frequently used to monitor new treatments in multiple sclerosis (MS), but its role is limited by the uncertain relationship between MRI parameters and clinical disability. A brain MRI study using nine MRI parameters was undertaken in 15 MS patients with a wide spectrum of disability to evaluate the relationship between each parameter and disability. A strong correlation was found between disability (measured using Kurtzke’s EDSS) and total lesion load on both proton density (PD; r = 0.79) and T1 (r = 0.71) weighted sequences. There was also a strong correlation of disability with average lesion magnetisation transfer ratio (MTR; r = –0.74) and calculated T1 (r = 0.71) but not with calculated T2 or the average signal intensity of lesions on the conventional T1-weighted, PD-weighted and heavily T2-weighted images. Thus, four parameters which measured either the extent of lesions (PD lesion load) or their pathological severity (MTR, calculated T1, hypointense T1-lesion load) were correlated significantly with disability. While this suggests that such parameters will be useful in treatment trial monitoring, further multi-parameter MRI studies, of larger cohorts and using a wider range of techniques, are indicated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1920
    Keywords: Key words Magnetic resonance imaging ; Multiple sclerosis ; Pulse sequences ; Lesion load
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Changes on serial assessments of brain MRI lesion load are used for monitoring therapeutic efficacy in patients with multiple sclerosis (MS). We assessed the accuracy and reliability of conventional spin-echo (CSE) and fast spin-echo (FSE) sequences for measurement of lesion volume using a semiautomated contour technique. Cranial CSE and FSE examinations of 18 patients with secondary progressive MS were studied. The mean lesion load was slightly higher with the CSE sequence (p = 0.002). Intraobserver variability was significantly higher for FSE than for CSE, according to both the coefficient of variation between two measurements (mean 2.48 % and 1.35 % respectively, p 〈 0.05) and back-transformed 95 % limits of agreement (1.005–1.060 for FSE; 0.988–1.019 for CSE). Although FSE sequences are quicker and the total lesion volume measurements are similar to those obtained with CSE, the poorer reproducibility raises doubts about the use of FSE to replace CSE in clinical trials.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...