Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Alpha-methyl-p-tyrosine  (1)
  • Polymer and Materials Science  (1)
Materialart
Erscheinungszeitraum
Schlagwörter
  • 1
    ISSN: 1432-2072
    Schlagwort(e): Morphine ; Analgesia ; Tolerance ; Apomorphine ; Alpha-methyl-p-tyrosine
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract In rats the development of one-trial tolerance to the analgesic action of i. p. administered morphine is disrupted by the postadministration of apomorphine (30 mg/kg at 5 min but not at 3 h) or alpha-methyl-p-tyrosine (200 mg/kg at 5 min and 3 h but not at 12 h). Diethyldithiocarbamate or propranol has no disruptive effect. It is suggested that development of tolerance to the analgesic effects of morphine is mediated by sequential time-dependent biochemical processes.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 0142-2421
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: The Design and construction of an ultrahigh vacuum multi-imaging scanning electron microscope is described. The microscope is designed to contain two field electron emission columns and can acquire simultaneous digital images from a 16-channel electron spectrometer, a four-quadrant back-scattered electron (BSE) detector, an Si(Li) x-ray detector, a SEM detector and the current flowing to ground through the sample. Because there is exact spatial registration between corresponding pixels in each of the images, it is possible to use the image set to make quantitative interpretations of the surface and subsurface chemistry. This is done using mathematical manipulations of the image set, together with models for the SEM, BSE and Auger signals. Techniques are described for setting up the alignment and characterizing the field of view and transmission function of the microscope and its spectrometer. Examples of multi-imaging from simple samples are given. The close coupling between the microscope and its control and interpretation computers provides considerable power for the analysis of inhomogeneous surfaces.
    Zusätzliches Material: 16 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...