Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 98 (1991), S. 0 
    ISSN: 1471-0528
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Summary. Two observers made independent estimates of volume flow across all four heart valves in 27 fetuses using a combination of cross-sectional and Doppler echocardiography. There were considerable discrepancies between observers in volume flow estimation arising from inconsistency both in cross-sectional and in Doppler measurements. One observer also produced a second estimate by making new measurements from the original recordings. There was considerable within-observer variability which was mainly due to errors in cross-sectional measurements. The problems of applying this technique to fetal cardiac haemodynamics are discussed.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 95 (1988), S. 0 
    ISSN: 1471-0528
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 94 (1987), S. 0 
    ISSN: 1471-0528
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Summary. Serial haemodynamic investigations were performed in 15 women at 38 weeks gestation and then 2, 6, 12 and 24 weeks after delivery. Cardiac output was measured by Doppler and cross-sectional echocardiography at the aortic, pulmonary and mitral valves. Cardiac chamber size and ventricular function were investigated by M-mode echocardiography. Flow measurements at the three intracardiac sites correlated closely. Cardiac output fell from a mean of 7.421/min at 38 weeks to 4.961/min at 24 weeks after delivery, a fall of 33%. Most of this decrease (28%) had occurred by 2 weeks. This was associated with a 20% reduction in heart rate and an 18% reduction in stroke volume. By 2 weeks after delivery there was a significant decrease in left atrial dimension and left ventricular end-diastolic dimension. Left ventricular wall thickness and mass declined throughout the period of study as did aortic, pulmonary and mitral valve areas. M-mode derived indices of myocardial contractility were all significantly reduced by 2 weeks and thereafter showed no further change. No haemodynamic differences were found between lactating and non-lactating mothers.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 96 (1989), S. 0 
    ISSN: 1471-0528
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 96 (1989), S. 0 
    ISSN: 1471-0528
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Summary. Serial haemodynamic investigations were performed in 15 women delivered by elective caesarean section under epidural anaesthesia at 38–40 weeks gestation. Cardiac output was measured by Doppler and cross-sectional echocardiography at the aortic valve. No haemodynamic changes were demonstrable after attainment of surgical anaesthesia (T5 or above). Stroke volume increased 13% after delivery of the placenta and remained elevated until the end of the operation at which time cardiac output was 11% above pre-operative values. Stroke volume and cardiac output fell during the first postoperative day. Heart rate remained elevated at pre-operative values for 48 h after delivery. There was a fall in heart rate and cardiac output between the second and the sixth days after delivery. By 2 weeks after delivery cardiac output was 28% lower than pre-operative values. Compared with pre-operative values, diastolic blood pressure was lower on the first and second postnatal days.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 94 (1987), S. 0 
    ISSN: 1471-0528
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Summary. A non-invasive technique for the measurement of cardiac output in pregnancy by combined cross-sectional and Doppler echocardiography at three intracardiac sites is described. The validity of the technique for use during pregnancy is reviewed. Comparison with cardiac output determined simultaneously by the direct Pick technique in 15 non-pregnant subjects showed close agreement for all three measurement sites. Acceptable measurements were obtained from the aortic and pulmonary valves in all pregnant subjects and from the mitral valve in 84% of pregnant subjects. The within-patient intra-observer and hour-to-hour variabilities of cardiac output in pregnant and non-pregnant subjects were 〈5% of the mean for all three valves studied. Flow measurements at each of the three intracardiac sites correlated closely. The advantages and limitations of the technique for use during pregnancy are discussed.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 96 (1989), S. 0 
    ISSN: 1471-0528
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 65 (1989), S. 1858-1865 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: The drift velocity of electrons (w) in SiF4 and BF3 has been measured over the density-reduced electric field (E/N) range 0.5×10−17 V cm2 ≤E/N≤300×10−17 V cm2 using a pulsed Townsend experimental technique. The electron attachment (η/N) and ionization (α/N) coefficients have also been measured in SiF4 and BF3 over the E/N range 30×10−17 V cm2 ≤E/N≤300×10−17 V cm2 in the same experiment. The electron drift velocities in these two gases exhibit regions of negative differential conductivity (NDC) similar to but smaller in magnitude than those in CH4 and CF4 . The effective ionization coefficient (α¯/N) has been obtained from the η/N and α/N measurements in both gases, from which the high-voltage limiting electric field strengths (E/N)lim have been found to be 123×10−17 V cm2 for BF3 and 121×10−17 V cm2 for SiF4. The significance of these results in modeling gas discharges for a number of technological applications is indicated.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 63 (1988), S. 52-59 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: In general, the electron attachment rate constant ka (〈ε〉, T), as a function of the mean electron energy 〈ε〉 and temperature T for electronegative gases which attach electrons nondissociative ily, decreases greatly with T from room temperature to T(approximately-less-than)600 K, while the ka (〈ε〉, T) of electronegative gases which attach electrons dissociatively increases with increasing T. Based on recent studies at our laboratory on ka (〈ε〉, T), we investigated the variation with T (∼295–575 K) of the uniform field breakdown strength, (E/N)lim, for three classes of electronegative gases: (a) gases such as c-C4F8 (and c-C4F6, 1−C3F6) which attach strongly low-energy ((approximately-less-than)1 eV) electrons nondissociatively and for which ka (〈ε〉, T) decreases precipitously with T above ambient: (b) gases such as C2F6 and CF3Cl which attach electrons exclusively dissociatively and whose ka (〈ε〉, T) increases with T; and (c) gases such as C3F8 and n-C4F10 which attach electrons both nondissociatively and dissociatively over a common low-energy range and whose ka (〈ε〉, T) first decreases and then increases with T above ambient. The (E/N)lim(T) has been found to decrease significantly with T for (a), to decrease slowly with T for (c), and to increase slightly with T for (b). These changes in (E/N)lim follow those in ka (〈ε〉, T). A similar behavior is expected for other electronegative gaseous dielectrics in the respective three groups.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 60 (1986), S. 24-35 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: An improved pulsed Townsend technique for the measurement of electron transport parameters in gases is described. The accuracy and sensitivity of the technique have been investigated by performing, respectively, electron attachment coefficient measurements in pure O2 over a wide range of E/N at selected O2 pressures and by determining the electron attachment and ionization coefficients and electron drift velocity in CH4 over a wide E/N range. Good agreement has been obtained between the present and the previously published electron attachment coefficients in O2 and for the drift velocity measurements in CH4. The data on the electron attachment coefficient in CH4 (measured for the first time) showed that with the present improved pulsed Townsend method, electron attachment coefficients up to 10 times smaller than the ionization coefficients at a given E/N value can be accurately measured. Our measurements of the electron attachment and ionization coefficients in CH4 are in good agreement with a Boltzmann equation analysis of the electron gain and loss processes in CH4 using published electron scattering cross sections for this molecule.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...