Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Journal of sol gel science and technology 8 (1997), S. 547-552 
    ISSN: 1573-4846
    Schlagwort(e): silicon alkoxide ; phase separation ; double pore structure ; liquid chromatography ; Van Deemter equation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Abstract Silica gels retaining double pore structure in the size ranges of micrometer and nanometer have been applied to the rod-shaped monolithic column for liquid chromatography. The macropore structure was designed by controlling the phase separation process induced by the hydrolysis and polycondensation of alkoxysilane, whereas the mesopore structure was tailored by the solvent exchange treatments on wet gels. The size exclusion chromatograms on polystyrene standards exhibited almost similar features for octadecyl-modified rod and conventional packed beads columns. The dependence of plate height on the velocity of mobile phase determined for amylbenzene was by far weaker in the rod column than in the packed beads column, suggesting that additional geometrical factors should be considered in describing the separation mechanism in the rod column.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Journal of sol gel science and technology 13 (1998), S. 163-169 
    ISSN: 1573-4846
    Schlagwort(e): silica gels ; phase separation ; pore size distribution ; liquid chromatography
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Abstract Utilizing the concurrence of polymerization-induced phase separation and sol-gel transition in the hydrolytic polycondensation of alkoxysilanes, a well-defined macroporous structure is formed in a monolithic wet gel. By exchanging the fluid phase of the wet gel with an appropriate external solution, the nanometer-range structure of the wet gel can be reorganized into structures with larger median pore size essentially without affecting the macroporous framework. The double-pore structure thus prepared is characterized by open pores distributed in discrete size ranges of micrometers and nanometers. A new type of chromatographic column (silica rod) has been developed using monolithic double-pore silica instead of packed spherical gel particles. Typical silica rod columns had significantly reduced pressure drops and improved analytical efficiencies which do not deteriorate even at higher sample flow rates, both arising from a greater macropore volume than particle packed columns.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Journal of sol gel science and technology 8 (1997), S. 547-552 
    ISSN: 1573-4846
    Schlagwort(e): silicon alkoxide ; phase separation ; double pore structure ; liquid chromatography ; Van Deemter equation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Abstract Silica gels retaining double pore structure in the size ranges of micrometer and nanometer have been applied to the rod-shaped monolithic column for liquid chromatography. The macropore structure was designed by controlling the phase separation process induced by the hydrolysis and polycondensation of alkoxysilane, whereas the mesopore structure was tailored by the solvent exchange treatments on wet gels. The size exclusion chromatograms on polystyrene standards exhibited almost similar features for octadecyl-modified rod and conventional packed beads columns. The dependence of plate height on the velocity of mobile phase determined for amylbenzene was by far weaker in the rod column than in the packed beads column, suggesting that additional geometrical factors should be considered in describing the separation mechanism in the rod column.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...