Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 75 (1994), S. 3611-3618 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The effect of current, voltage, and magnetic field on the radial profile of ions sputtering a flat cathode has been studied in a hollow cathode enhanced magnetron discharge. The measurements of sputtering rate were made using a directional quartz crystal microbalance, translated parallel to the cathode. We find the radial sputtering profiles are determined by the plasma sheath thickness, which can be calculated using the Child–Langmuir law for collisionless space-charge limited current flow. A hollow cathode electron source was used to control the sheath thickness by increasing the current to the magnetron cathode at a given voltage and constant pressure (0.07 Pa). Uniformity of the radial profiles increases with decreasing sheath thickness (i.e., at lower voltages and higher current densities). The angular distribution of sputtered atoms was measured by changing the polar angle of the microbalance. The angular distributions are asymmetric on either side of the radial position where the ion current density to the cathode is maximum. We believe this is due to ions which impact the cathode at angles up to ≈10° from the normal, having been radially accelerated away from the position of maximum plasma density.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 89 (1982), S. 0 
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary. Guanosine 3′:5′-phosphate (cyclic GMP) in urine has been used to monitor the response of patients with ovarian cancer to treatment. Changes in the cyclic GMP level appear to correlate well with clinical status in that the disappearance of clinically detectable tumour is associated with a drop in the level whereas a tumour recurrence is associated with an elevation. Serially measured cyclic GMP is valuable for detecting a recurrence of tumour growth in patients in clinical remission and can predate any clinical signs by as much as 10 months. In patients who show no response to treatment, cyclic GMP levels in urine are elevated in the majority of specimens collected.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 89 (1982), S. 0 
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary. A case of extremely severe birth asphyxia is reported. In spite of successful resuscitation the arterial pH was still only 6.6 at the age of 1 h. Assessment at 3 years 10 months revealed that the child was not only completely normal, but was of superior intelligence. This case demonstrates the advisability of maintaining an optimistic approach even when very severe fetal acidosis is detected around the time of birth.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Biochemistry 21 (1982), S. 646-651 
    ISSN: 1520-4995
    Source: ACS Legacy Archives
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 65 (1994), S. 617-625 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: RELAX is a resonance ionization, time-of-flight mass spectrometer to which a cryogenic sample concentrator has been added. This has resulted in an increase in sensitivity by a factor greater than 100. The sample concentrator consists of a localized cold spot in the ion source, onto which the sample condenses, and a heating laser to release the condensed sample into the ionization region. The lifetime against detection of a sample atom is close to 20 min, which corresponds to a count rate of 1 cps from a sample of 1000 atoms, while the mass resolution is 300 (10% peak height). Sensitivity depends on the return time of sample atoms to the cold spot (10 s) and the fraction of these atoms subsequently ionized (∼1%). The minimum sample size which can be measured is limited only by blank, which is currently 2×10−15 cc STP total xenon and isotopically atmospheric (this can be attributed to the large aliquots of xenon admitted to the instrument during development, and so may be expected to decrease with time). The precision of abundance measurements has been improved by the incorporation of pulse height discrimination and pulse counting detection for the less abundant isotopes. The design, construction, and operation of the spectrometer in its new configuration are described with particular attention to abundance extraction. The effects of the sample concentrator on ionization efficiency and discrimination are discussed in detail, as are interferences from nonresonantly ionized hydrocarbons and the means of accounting for them.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 65 (1989), S. 3671-3679 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The Monte Carlo technique has been used to simulate the thermalization of sputtered atoms in the filling or background gas within a planar sputtering discharge. The model uses Thompson's theoretical distribution of the energy of atoms sputtered from the cathode surface together with an approximation to the 6–12 Lennard–Jones potential to describe collisions between sputtered atoms and background gas atoms. The diffusion of the thermalized atoms is included explicitly in the Monte Carlo calculations. The velocity distribution of sputtered atoms between the cathode and substrate is calculated, from which their average kinetic energy is determined as a function of the product Pd, where P is the background gas pressure and d is the distance from the cathode. Because of the effect of the finite cathode-substrate separation on back diffusion, it was found that PD, where D is the cathode-to-substrate separation, is an important parameter in describing thermalization and, consequently, the average energy of sputtered atoms throughout the discharge. These calculations are compared with theoretical analyses of other workers and show good agreement with experimental results.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 63 (1941), S. 1334-1335 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 24 (1952), S. 791-793 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 71 (1997), S. 3758-3760 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A large increase in the quantum efficiency (QE) and open-circuit voltage Voc of GaInAsSb thermophotovoltaic (TPV) devices is obtained by the use of an AlGaAsSb window layer compared with devices without a window layer. The TPV structure, grown on GaSb substrates by organometallic vapor phase epitaxy or molecular beam epitaxy, consists of a 1-μm-thick n-GaInAsSb base layer, a 3-μm-thick p-GaInAsSb emitter layer, a 100-nm-thick AlGaAsSb window layer, and a 25-nm-thick GaSb contacting layer. The band-gap energy of the lattice-matched GaInAsSb is 0.53–0.55 eV. The peak internal QE of the TPV cells with the window is 〉90%, compared with less than 60% for those without the window. At a short-circuit current density of ∼1000 mA/cm2, Voc of ∼300 meV is obtained for cells with the window layer, compared with less than 220 meV without the window layer. These increases are attributed to a substantial decrease in the surface recombination velocity with the window layer. Based on a standard calculation, the electron diffusion length in the p-GaInAsSb layer is at least 5 μm. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 69 (1996), S. 2804-2806 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Midinfrared InAs-based and GaSb-based semiconductor lasers with wavelengths from 3.3 to 4 μm have been used in a grating-tuned external cavity configuration. At 80 K, a tuning range up to ∼8% of the center wavelength has been obtained. Power of 0.2 W peak, 20 mW average has been demonstrated for multimode operation with ∼1–2 nm linewidth. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...