Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Absolutely calibrated measurements of the neutron yield are important for the evaluation of the plasma performance such as the fusion gain Q in D-D operating tokamaks. The time-resolved neutron yield is measured with 235U and 238U fission chambers and 3He proportional counters in the JT-60U tokamak. The in situ calibration was performed by moving the 252Cf neutron source toroidally through the JT-60 vacuum vessel. Detection efficiencies of three 235U and two 3He detectors were measured for 92 locations of the neutron point source in toroidal scans at two different major radii. The total detection efficiency for the torus neutron source was obtained by the averaging the point efficiencies over the whole toroidal angle. The uncertainty of the resulting detection efficiency for the plasma neutrons is estimated to be ±11%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 5270-5278 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Absolutely calibrated measurements of the neutron yield are important for the evaluation of plasma performance such as the fusion gain Q in D–D operating tokamaks. The time-resolved neutron yield is measured with 235U and 238U fission chambers and 3He proportional counters in the JT-60U tokamak. The in situ calibration was performed by moving the 252Cf neutron source toroidally through the JT-60 vacuum vessel. Detection efficiencies of three 235U and two 3He detectors were measured for 92 locations of the neutron point source in toroidal scans at two different major radii. The total detection efficiency for the torus neutron source was obtained by averaging the point efficiencies over the whole toroidal angle. The uncertainty of the resulting detection efficiency for the plasma neutrons is estimated to be ±11%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford [u.a.] : International Union of Crystallography (IUCr)
    Acta crystallographica 48 (1992), S. 1237-1239 
    ISSN: 1600-5759
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford [u.a.] : International Union of Crystallography (IUCr)
    Acta crystallographica 48 (1992), S. 964-965 
    ISSN: 1600-5759
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford [u.a.] : International Union of Crystallography (IUCr)
    Acta crystallographica 48 (1992), S. 1152-1154 
    ISSN: 1600-5759
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Journal of neural transmission 90 (1992), S. 125-136 
    ISSN: 1435-1463
    Keywords: Nefiracetam (DM-9384) ; oxiracetam ; indeloxazine ; monoamines
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The effects of acute and chronic administration of nefiracetam, a pyrrolidone derivative, on monoaminergic neurotransmitter systems in the mouse hippocampus, frontal cortex, hypothalamus, and striatum were studied. The levels of monoamines and of their metabolites were measured by high performance liquid chromatography with electrochemical detection on the first, 7th, and 14th days after nefiracetam was given. The neurochemical effects of nefiracetam were compared with those of oxiracetam and indeloxazine. Acute administration of nefiracetam (10 mg/kg, po) and oxiracetam (10 mg/ kg, po) had no effect on the levels of noradrenaline (NA), dopamine (DA), or 5-hydroxytryptamine (5-HT), or on the levels of their metabolites, 3-methoxy-4-hydroxyphenylglycol (MHPG), 3,4-dihydroxyphenylacetic acid (DOPAC), homovanillic acid (HVA), and 5-hydroxyindoleacetic acid (5-HIAA), in any of the regions examined. In contrast, a single dose of indeloxazine (10 mg/kg, po) decreased the levels of MHPG, DOPAC, and 5-HIAA in all regions examined. After chronic administration of nefiracetam (10 mg/kg, po, once daily), the levels of MHPG, DOPAC, and 5-HIAA were higher than control in all regions on the 14 th day only. Oxiracetam (10 mg/kg, po, once daily) similarly increased the levels of MHPG, DOPAC, and 5-HIAA in the hippocampus, frontal cortex, and striatum, but not in the hypothalamus. Conversely, indeloxazine (10 mg/ kg, po, once daily) decreased the levels of MHPG and 5-HIAA in all regions and the levels of DOPAC and HVA in the hippocampus and striatum as measured on the 7 th and 14 th days. These results show that nefiracetam has a delayed effect on brain monoaminergic metabolism, and that its effects are similar to those of oxiracetam, but clearly different from those of indeloxazine.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1435-1463
    Keywords: Amino acid neurotransmitters ; HPLC-ECD ; mouse brain ; electroconvulsive shock
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary For simultaneous assay of the five neurotransmitter amino acids, Asp, Glu, Gly, Tau, and GABA in brain tissues, a very rapid and simple chromatographic method using high-performance liquid chromatography with electrochemical detection in combination with o-phthalaldehyde derivatization is described. Because the present method permits the determination of these five amino acids within less than five minutes in one chromatographic run, up to 100 samples a working day can be analyzed using an autosampler. Withinrun coefficients of variation for these five amino acids were less than 2% (n=20). The quantitative detection limit was 2.5 pmol for the 5 amino acids. The present method has been applied to the measurement of the five amino acid neurotransmitter levels in several discrete brain regions of mice treated with and without electroconvulsive shock.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1432-0533
    Keywords: High molecular weight neurofilament ; Phosphorylation ; Peripheral nervous system ; Amyotrophic lateral sclerosis ; Multiple system atrophy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Using monoclonal antibody (Ta-51) that specifically binds phosphorylated high molecular weight neurofilament (pNFH) proteins, we investigated the occurrence of perikaryal pNFH in the spinal ventral horn motoneurons, intermediolateral column (ILC) neurons, sympathetic ganglion neurons and dorsal root ganglion (DRG) neurons obtained from patients with amyotrophic lateral sclerosis (ALS) and multiple system atrophy (MSA) and from control cases. In the controls, a system-dependent variation in perikaryal Ta-51 immunoreactivity was observed. Very few ventral horn cells and ILC neurons were stained with Ta-51, while large population of DRG neurons and sympathetic neurons were Ta-51 positive. The incidence of perikaryal immunoreactivity in the ventral horn cells was significantly increased in ALS and MSA. Some ILC neurons in ALS were Ta-51 positive and their incidence was significantly higher than that of the controls. These data suggest that both ILC neurons and ventral horn cells are affected with respect to pNFH metabolism in ALS and MSA. No significant difference was, however, detected in the Ta-51 immunoreactivity of both DRG and sympathetic ganglion neurons in ALS and MSA as compared with the controls.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...