Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • Critically ill patients  (1)
  • Key words Coronary bypass surgery – diastolic function –¶echocardiography – time constant of relaxation  (1)
  • 1
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Gesamteiweiß ; Albumin ; Hypoalbuminämie ; Intensivpatienten ; Key words Total protein ; Hypoalbuminaemia ; Critically ill patients
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract In clinical practice, the administration of supplementary albumin often depends on the measured plasma concentration of total protein (TPC). A TPC of less than 5 g/dl is generally accepted as an indication for albumin therapy, assuming an albumin concentration of less than 2.5 g/dl. However, a physiological relation between TPC and albumin cannot be expected in critically ill patients, and thus, measurement of TPC may be misleading as an indicator for the use of albumin. Therefore, we investigated the sensitivity and specificity of TPC testing for diagnosing hypoalbuminaemia requiring treatment. Methods. In this prospective study, 210 consecutive patients were included. Protein electrophoresis was performed three times a week; the second electrophoresis was selected for evaluation. Applied statistical analysis revealed the number of positive total protein tests indicating hypalbuminaemia requiring treatment (sensitivity) and the number of negative with tolerably reduced albumin concentrations (specificity). Results. Of the investigated patients, 27.6% had normal TPCs between 6.2 and 8.0 g/dl. In 81.9% of cases an albumin concentration below 3.5 g/dl was found, while 43 patients had a concentration below 2.5 g/dl. The sensitivity and specificity of TPC measurement for the diagnosis of clinically relevant hypoalbuminaemia (albumin concentration 〈2.5 g/dl) was calculated at different cutoff points for total protein. With a TPC of 6.0 g/dl, the sensitivity was 0.96 and the specificity 0.44. With a cutoff point of 5.0 g/dl, the sensitivity was reduced to 0.65 and specificity increased to 0.86. Finally, with a TPC of 4.0 g/dl sensitivity was 0.25 and specificity almost 1. Conclusions. Depending on the cutoff point for TPC, a relevant albumin requirement would frequently not be detected. In other cases, a need for albumin would be assumed from a reduced TPC even though the albumin concentration still exceeded 2.5 g/dl. Therefore, determination of TPC is not a suitable indicator of the need for albumin replacement. As a result, we suggest routine determination of albumin concentrations instead of TPC.
    Notes: Zusammenfassung In der klinischen Routine wird die Substitution von Humanalbumin häufig von der Gesamteiweißkonzentration abhängig gemacht, obwohl ein konstantes Verhältnis beider Variablen nicht immer zu erwarten ist. In der vorliegenden Untersuchung wurde die Sensitivität und Spezifität der Gesamteiweißbestimmung im Hinblick auf einen therapiebedürftigen Albuminmangel bei Intensivpatienten untersucht. Als Ergebnis zeigte sich, daß die Bestimmung der Gesamteiweißkonzentration mit erheblichen Fehleinschätzungen der Albuminkonzentration verbunden ist. Bei einer Interventionsschwelle von 5,00 g/dl Gesamteiweiß betrug die Sensitivität 0,64 und die Spezifität 0,86. Dagegen betrug bei einer Gesamteiweißkonzentration von 4,00 g/dl die Sensitivität nur noch 0,25, die Spezifität jedoch annähernd 1. Abhängig von der variablen Interventionsschwelle bezüglich der Gesamteiweißkonzentration wird einerseits ein relevanter Albuminbedarf häufig nicht erkannt. Andererseits kann in einigen Fällen eine unnötige Substitution erfolgen. Daher ist der Gesmteiweißtest zur Indikationsstellung der Albuminsubstitution nicht geeignet. Die direkte Bestimmung der Albuminkonzentration ist kostengünstig und routinemäßig durchführbar und sollte im Sinne einer rationalen Diagnostik und Therapie den Gesamteiweißtest ersetzen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0930-9225
    Keywords: Schlüsselwörter Koronarchirurgie – Echokardiographie – Diastolische Ventrikelfunktion – Zeitkonstante der myokardialen Relaxation ; Key words Coronary bypass surgery – diastolic function –¶echocardiography – time constant of relaxation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary There is evidence that diastolic function is a major determinant of overall cardiac performance. Intraoperative use of transesophageal echocardiography (TEE) enables Doppler measurement of mitral inflow pattern (E/A ratio). The E/A ratio is suggested to be a reliable index of changes in myocardial relaxation. In the present study we compared the time course of the E/A ratio and the time constant of myocardial relaxation (τ) assessed by direct left ventricular pressure recordings in patients before and after cardiopulmonary bypass (CPB). After ethical approval, 12 patients undergoing CABG surgery were studied. Measurements of the E/A ratio and τ were performed after induction of anesthesia (I), immediately prior to CPB with the pericardium open (II), 5 min after CPB (III), and after sternal closure (IV). Time constant of myocardial relaxation was calculated as the reciprocal value of the slope of the left ventricular dP/dt and left ventricular pressure plot. The E/A ratio was significantly decreased at the end of surgery (IV). In contrast, τ was increased immediately after CPB, but decreased after sternal closure (IV). Cardiac index and heart rate both increased after CPB.¶ The results of the present study demonstrate that diastolic dysfunction occurred immediately after CPB, as indicated by an increase in the time constant of myocardial relaxation. However, τ improved rapidly to pre-CPB values. The E/A ratio alone failed to detect the initial post-CPB alteration in left ventricular relaxation.
    Notes: Zusammenfassung Die Entwöhnung von der extrakorporalen Zirkulation (EKZ) stellt weiterhin eine kritische Phase während kardiochirurgischer Operationen dar. Es werden regelhaft myokardiale Funktionsstörungen beobachtet, wobei die diastolische Funktion nur eingeschränkt zu beurteilen ist. Die Einführung der transösophagealen Echokardiographie (TEE) ermöglicht dopplersonographisch die Differenzierung zwischen maximalem früh- (E) und spätdiastolischem (A) Blutfluß vom linken Atrium in den Ventrikel. Das Verhältnis von E zu A (E/A-Ratio) wird als ein Maß für die frühe diastolische Relaxation des Myokards angesehen. Wir untersuchten ob Änderungen der E/A-Ratio vor und nach Herz-Lungen-Maschine (HLM) mit Änderungen der durch direkte linksventrikuläre Druckmessung bestimmten Zeitkonstanten (τ) der frühen myokardialen Relaxation korrespondieren. Es wurden 12 koronarchirurgische Patienten mit eingeschränkter linksventrikulärer Funktion untersucht. Linksventrikulärer Druck und Druckabfallsgeschwindigkeit wurden mit einem Mikromanometerkatheter registriert. Zur Berechnung von τ wurde LVP gegen –dP/dt aufgetragen und mittels linearer Regressionsanalyse die Steigung der resultierenden Geraden bestimmt. Aus dem reziproken Wert der Steigung ergibt sich τ. Zur Bestimmung der E/A-Ratio wurde die Meßkammer des gepulsten Dopplers zwischen den Spitzen der Segel der Mitralklappe plaziert und der Bluteinstrom kontinuierlich bestimmt. Der mittlere arterielle, zentralvenöse Blutdruck und der pulmonalkapilläre Verschlußdruck sowie Herzfrequenz (HF) und Herzindex (HI) wurden nach Narkoseeinleitung (I), Eröffnung des Perikards (II), Entwöhnung von der HLM (III) und nach Sternalverschluß (IV) bestimmt. Die E/A-Ratio war am Ende der Operation (IV) signifikant erniedrigt. Im Gegensatz dazu war die Zeitkonstante der myokardialen Relaxation (τ) unmittelbar nach Abgang von der HLM signifikant (III) erhöht. HI und HF waren post-EKZ erhöht. Der nach Entwöhnung von der HLM gefundene Anstieg von τ ist hinweisend für eine diastolische Funktionsstörung, welche allerdings bereits am Punkt IV nicht mehr signifikant unterschiedlich zum Ausgangswert war. Die E/A-Ratio war hingegen unmittelbar post-HLM nicht signifikant erniedrigt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...