  • Biomechanics  (6)
  • Arthrodèse atlanto-axoïdienne postérieure  (1)
  • Calf spine  (1)
  • 1
    ISSN: 1432-0932
    Keywords: Key words Spine ; Biomechanics ; Implant testing ; In vitro testing ; Test standard
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract New implants and new surgical approaches should be tested in vitro for primary stability in standardized laboratory tests in order to decide the most appropriate approach before being accepted for clinical use. Due to the complex and still unknown loading of the spine in vivo a variety of different test loading conditions have been used, making comparison of the results from different groups almost impossible. This recommendation was developed in a series of workshops with research scientists, orthopedic and trauma surgeons, and research and development executives from spinal implant companies. The purpose was to agree on in vitro testing conditions that would allow results from various research groups to be compared. This paper describes the recommended loading methods, specimen conditions, and analysis parameters resulting from these workshops.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0932
    Keywords: Key words Cervical spine ; Biomechanics ; Flexibility ; Interbody fusion device
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Interbody fusion cages are small hollow implants that are inserted into the intervertebral space to restore physiological disc height and to allow bony fusion. They sometimes cause clinical complications due to instability, subsidence or dislocation. These are basic biomechanical parameters, which influence strongly the quality of a fusion device; however, only few data about these parameters are available. Therefore, the purpose of the present study was to investigate the primary stabilizing effect of four different cervical fusion devices in in vitro flexibility tests. Twenty-four human cervical spine segments were used in this study. After anterior discectomy, fusion was performed either with a WING cage (Medinorm AG, Germany), a BAK/C cage (Sulzer Spine-Tech, USA), an AcroMed cervical I/F cage (DePuy AcroMed International, UK) or bone cement (Sulzer, Switzerland). All specimens were tested in a spine tester in the intact condition and after implantation of one of the four devices. Alternating sequences of pure lateral bending, flexion-extension and axial rotation moments (± 2.5 Nm) were applied continuously and the motions in each segment were measured simultaneously. In general, all tested implants had a stabilizing effect. This was most obvious in lateral bending, where the range of motion was between 0.29 (AcroMed cage) and 0.62 (BAK/C cage) with respect to the intact specimen (= 1.00). In lateral bending, flexion and axial rotation, the AcroMed cervical I/F cages had the highest stabilizing effect, followed by bone cement, WING cages and BAK/C cages. In extension, specimens fused with bone cement were most stable. With respect to the primary stabilizing effect, cages, especially the AcroMed I/F cage but also the WING cage and to a minor extent the BAK/C cage, seem to be a good alternative to bone cement in cervical interbody fusion. Other characteristics, such as the effect of implant design on subsidence tendency and the promotion of bone ingrowth, have to be determined in further studies.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-0932
    Keywords: Key words Lumbar spine ; Metastases ; Corpectomy ; Vertebral body replacement ; Biomechanics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Metastatic spine lesions frequently require corpectomy in order to achieve decompression of the spinal cord and restoration of spinal stability. A variety of systems have been developed for vertebral body replacement. In patients with prolonged life expectancy due to an improvement of both systemic and local therapy, treatment results can be impaired by a loosening at the implant-bone interface or mechanical failure. Furthermore, early detection of a metastatic recurrence using sensitive imaging modalities like computed tomography (CT) and magnetic resonance imaging (MRI) is possible in these patients without artefact interference. The aim of our pilot study was to evaluate the clinical applicability and results of a new radiolucent system for vertebral body replacement in the lumbar spine. The system consists of bone-integrating biocompatible materials – a polyetherurethane/bioglass composite (PU-C) replacement body and an integrated plate of carbon-fibre reinforced polyetheretherketone (CF-PEEK) – and provides high primary stability with anterior instrumentation alone. In a current prospective study, five patients with metastatic lesions of the lumbar spine were treated by corpectomy and reconstruction using this new system. Good primary stability was achieved in all cases. Follow-up (median ¶15 months) using CT and MRI revealed progressive osseous integration of the PU-C spacer in four patients surviving more than 6 months. Results obtained from imaging methods were confirmed following autopsy by biomechanical investigation of an explanted device. From these data, it can be concluded that implantation of the new radiolucent system provides sufficient long-term stability for the requirements of selected tumour patients with improved prognosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-0932
    Keywords: Key words Biomechanics ; Stability ; Calf spine ; Spinal implants ; Transpedicular fixation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The Kluger internal fixator, with its artificial fulcrum outside the operative site, had to be extended for multisegmental use. Three different prototypes, called Central Bar (CB), Double Bar I (DB I) and Double Bar II (DB II) were designed, which were fully compatible with the existing reduction system. To evaluate the ability of these newly developed systems to provide primary stability in a destabilized spine, their stiffness characteristics and stabilizing effects were investigated in multidirectional biomechanical stability tests and compared with those of the clinically well-known Cotrel-Dubousset (CD) system. The investigations were performed on a spine tester using freshly prepared calf spines. The model tested was that of an intact straight spine followed by a defined three-column lesion simulating the most destabilizing type of injury. Pure moments of up to 7.5 Nm were continuously applied to the top of each specimen in flexion/extension, left/right axial rotation, and left/right lateral bending. Segmental motion was measured using a three-dimensional goniometric linkage system. Range of motion and stiffness within the neutral zone were calculated from obtained load-displacement curves. The DB II attained 112.5% (P = 0.26) of the absolute stiffness of the CD system in flexion and enhanced its stability in extension by up to 144.3% (P = 0.004). In axial rotation of the completely destabilized spine, this system achieved 183.3% of the stiffness of the CD system (P 〈 0.001), and in lateral bending no motion was measured in the most injured specimens stabilized by the DB II. The DB I, which was the first to be designed and was considered to provide high biomechanical stability, did not attain the stiffness standard set by the CD system in either flexion/extension or axial rotation of the most injured spine. The study confirms that it is worthwhile to evaluate in vitro the biomechanical properties of a newly developed implant before its use in patients, in order to refine weak construction points and help to reduce device-related complications and to better evaluate its efficacy in stabilizing the spine.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-0932
    Keywords: Biomécanique ; Rachis cervical ; Fracture de l'odontoïde ; Stabilité ; Ostéosynthèse de l'odontoïde par vis ; Biomechanics ; Cervical spine ; Odontoid fracture ; Stability ; Odontoid screw fixation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Fresh odontoid fractures of types II and III and in some cases nonunions of the odontoid can be repaired by direct anterior screw fixation preserving C1–C2 motion. The goal of this experimental study was to investigate the biomechanical stability of the fragment achieved by this direct odontoid osteosynthesis according to Böhler. Sixteen human C1–C2 segments with fractures of type II or type III were biomechanically tested in vitro under standardized conditions. Flexion and extension moments, anterior and posterior shear forces were applied, and the motion of the refixed odontoid fragment relative to C2 was determined. The results show that direct screw fixation of the odontoid under the experimental conditions provides sufficient stability for the dens fragment.
    Notes: Résumé Les fractures fraîches de l'odontoïde de type II et III et certains cas de pseudarthrose de l'odontoïde peuvent être réparés par une ostéosynthèse antérieure directe préservant la mobilité C1–C2. Le but de cette étude expérimentale était d'explorer la stabilité biomécanique permise par cette ostéosynthèse directe de l'odontoïde selon Böhler. 16 segments C1–C2 présentant des fractures de type II et III ont été testés in vitro dans des conditions bien définies. On a appliqué des moments de flexion et d'extension et des forces de cisaillement antérieur et postérieur et l'on a déterminé la mobilité du fragment odontoïdien refixé par rapport à C2. Les résultats ont montré que la fixation directe par vissage de l'odontoïde assure dans les conditions expérimentales une stabilité suffisante au fragment odontoïdien.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    European spine journal 3 (1994), S. 91-97 
    ISSN: 1432-0932
    Keywords: Biomechanics ; Spine tester ; Spinal stability ; Muscle simulation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We report a new apparatus to determine the quasistatic, three-dimensional, load-displacement characteristics of spines including muscle forces. The loading frame can be adapted to mono- and polysegmental specimens from the lumbar or cervical spine as well as to entire spines. Three force and three moment components can be applied in either direction individually or in combination with no constraint on the resulting motion; the loads can be applied at user-chosen rates of application and release with continuous recording of displacements, so as to study either creep or relaxation. The loads and displacement-measuring devices are computer-controlled. Thus, this testing device provides a tool for many kinds of stability tests and for basic research of spine biomechanics. A first experiment shows that the application of muscle forces significantly affects the load-deformation characteristics and intradiscal pressure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1432-0932
    Keywords: Biomécanique ; Rachis cervical ; Fracture de l'odontoïde ; Instabilité atlanto-axoïdienne ; Arthrodèse atlanto-axoïdienne postérieure ; Biomechanics ; Cervical spine ; Odontoid fracture ; Atlantoaxial instability ; Posterior atlantoaxial fusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Unstable C1-C2 segments are generally treated surgically. Depending on the indication a direct screw fixation of the odontoid or a C1-C2 arthrodesis is a possible technique. In this experimental in vitro study the three different atlantoaxial fusion techniques by Gallie, Brooks, and Magerl were compared biomechanically. Sixteen human C1-C2 segments with odontoid fractures of type II and III were investigated under standardized conditions. Flexion and extension moments, anterior, and posterior shear forces, left and right torsional moments were applied, and the motion of C1 relative to C2 was determined. The results of this investigation show clearly that the segments treated with the technique by Magerl with transarticular screws achieved the highest stiffness, compared to the wiring methods of Brooks and Gallie. These differences were most evident for posterior shear forces and for torsional moments. For these load conditions the ratio of stiffness Magerl: Brooks: Gallie was about 10:2:1. Significant differences for the plastic deformation of the differently fixed C1-C2 segments were found within the first few load/unload cycles, which give information about the relationship between primary and long-term stability.
    Notes: Résumé L'instabilité C1-C2 est le plus souvent traitée chirurgicalement. Selon l'indication, peuvent être proposées soit une ostéosynthèse par vissage direct de l'odontoïde, soit une arthrodèse C1-C2. Dans cette étude expérimentale in vitro, on a comparé au plan biomécanique, les trois différentes techniques d'arthrodèse atlanto-axoïdiennes, selon Gallie, Brooks et Magerl. 16 segments C1-C2 présentant des fractures de type II et III ont été testés in vitro dans des conditions bien définies. On a appliqué des moments de flexion et d'extension, des forces de cisaillement antérieur et postérieur et des moments de torsion vers la droite et vers la gauche, et l'on a analysé la mobilité de C1-C2. Les résultats de cette investigation ont clairement démontré que les segments traités par la technique de Magerl avec des vis transarticulaires, présentaient la plus grande rigidité, en comparaison des méthodes de cerclage de Brooks et de Gallie. Ces différences étaient plus évidentes dans le cas du cisaillement postérieur et de la torsion. Dans ces conditions de contrainte, le rapport de rigidité Magerl/Brooks/Gallie était de 10/2/1. Des différences significatives de déformation plastique ont été retrouvées entre les différentes fixations C1-C2 au cours des premiers cycles de mise en charge et décharge, qui renseignent sur la relation entre la stabilité primaire et à long terme.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...