Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Herz-, Thorax- und Gefässchirurgie 13 (1999), S. 249-254 
    ISSN: 0930-9225
    Keywords: Schlüsselwörter Intraaortale Ballonpumpe – perioperatives low output Syndrom – mechanische Kreislaufunterstützung ; Key words Intraaortic balloon pump – perioperative low output syndrome – mechanical circulatory support
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary In a prospective study 97 patients with intraoperative low output syndrome, who were operated with heart-lung bypass and received an implantation of an intraaortic ballon pump, were analyzed. All operations were performed between July 1996 and July 1997. Sixty operations were elective and 37 patients were operated in an emergency situation. Twenty-nine of all patients died perioperatively. Sixty-eight patients could be discharged from the hospital. Patients who died perioperatively were significantly older, had a significantly lower LVEF pre- and perioperatively, had a higher catecholamines demand despite the IABP support, were anuric or nearly anuric, had a lower cardiac index, and the total bypass time was significantly longer. All five patients who had received mitral valve procedures died. We conclude that the success or failure of perioperative IABP support can be predicted early after implantation. In patients with low output syndrome despite the IABP support, an implantation of a ventricular assist system should be considered.
    Notes: Zusammenfassung In einer prospektiven Studie wurden von 7/96 bis¶7/97, 97 Patienten mit intraoperativem low output syndrome untersucht, bei denen zum Abgang von der Herzlungenmaschine eine IABP implantiert wurde. Dabei waren 60 dieser Operationen elektiv vorgenommen worden, bei 37 Fällen handelte es sich um Notfall-Eingriffe. Von den 97 Patienten verstarben 29 Patienten perioperativ. 68 Patienten konnten nach Hause entlassen werden. Patienten, die perioperativ verstarben, waren signifikant älter, hatten eine signifikant geringere LVEF prä- und intraoperativ, hatten einen signifikant höheren Katecholaminbedarf trotz IABP, waren an- oder oligourisch, hatten einen signifikant geringeren cardiac index nach IABP-Implantation und hatten eine signifikant längere „Maschinenzeit“ als Patienten, die sich durch den Einsatz der IABP erholten. Von 5 Patienten bei denen eine Mitralklappenoperation vorgenommen worden war und bei denen perioperativ eine IABP implantiert worden war, überlebte keiner den perioperativen Zeitraum. Wir folgern, der Erfolg oder Mißerfolg des Einsatzes einer IABP läßt sich intraoperativ schon frühzeitig absehen. Bei Patienten, die trotz IABP-Einsatzes ein low output syndrome bieten, ist frühzeitig die Implantation eines ventrikulären Assist Systems zu diskutieren.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0930-9225
    Keywords: Schlüsselwörter Plasmavolumen – Blutvolumen – Farbstoff-Verdünnungsmethode – Anästhesie – Hypotension – aortokoronarer ; Key words Anesthesia – blood volume – coronary artery bypass – hypotension – dye dilution technique – plasma volume
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Background: Hypotension during induction of anesthesia is frequently observed in patients undergoing coronary artery bypass grafting (CABG). On the other hand, a reduction of intravascular volume has been described in patients suffering from cardiovascular diseases. The aim of this study is to evaluate the influence of intrinsic volume deficit on the extent of arterial hypotension during induction of anesthesia. Therefore, according to the measured intravascular volume, the examined patients were divided into a normovolemic and a hypovolemic group. The hemodynamic changes have been compared between these two groups. Methods: Thirty-eight patients with normal left-ventricular function scheduled for CABG were investigated. Blood volume was calculated from hematocrit and plasma volume determined by the dye-dilution method with Indocyanine-green (ICG). According to the measured blood volumes the patients were divided into a hypovolemic (HV) and a normovolemic (NV) group of at least 13 patients per group. Twelve patients with intermediate blood volumes were not included in the statistical evaluation. Hemodynamic data were measured three times: before and after induction of anesthesia as well as after endotracheal intubation. Results: Due to division of the patients, body weight (BW) indexed blood volume (mean ± SD) was 68.5 ± 3.73 ml · kg;–1 in the NV group and 54.8 ± 4.86 ml · kg;–1 in the HV group (p 〈 0.001). At all measurements, heart rate was significantly lower and pulmonary capillary wedge pressur, pulmonary artery pressure, and central venous pressure significantly higher in the NV group than in the HV group. In contrast, the values of mean arterial pressure (MAP), systemic vascular resistance (SVR) and cardiac index (CI) did not differ significantly between both groups at any time. Correlation analysis revealed that the extent of arterial hypotension was mainly influenced from MAP before induction of anesthesia (r = 0.6674, p 〈 0.001). Conclusions: There is no difference in the decrease of MAP after induction of anesthesia between the hypovolemic and the normovolemic group. Arterial hypotension is caused mainly by pre-induction MAP which should be noted for treatment.
    Notes: Zusammenfassung In der vorliegenden Arbeit wurde der Einfluß des aktuellen intravasalen Volumendefizits auf den Abfall des arteriellen Blutdrucks während der Narkoseeinleitung bei Patienten zur aortokoronaren Venenbypass-Operation (ACVB) untersucht. Bei 38 Patienten mit normaler linksventrikulärer Funktion wurde vor Narkoseeinleitung das Plasmavolumen mit der Farbstoff-Verdünnungsmethode (Indozyanin-Grün) gemessen und das Blutvolumen mit Hilfe des Hämatokrits berechnet. Hämodynamische Messungen wurden sowohl vor und nach der endotrachealen Intubation durchgeführt. Entsprechend der gemessenen Blutvolumina wurde eine hypovolämische (HV) und eine normovolämische Gruppe (NV) mit je 13 Patienten gebildet. Die dazwischen liegenden 12 Patienten wurden nicht in die statistische Analyse mit einbezogen. In der Gruppe HV war das Blutvolumen mit 54,8 ± 4,86 ml · kg;–1 signifikant niedriger als in der Gruppe NV mit 68,5 ± 3,73 ml · kg;–1 (p 〈 0,001). Zu allen Meßzeiten war in der Gruppe HV der zentrale Venendruck, der pulmonalkapillare Wedge-Druck und der pulmonalarterielle Mitteldruck signifikant niedriger und die Herzfrequenz höher als in der Gruppe NV. Dagegen waren zu keinem Meßzeitpunkt der Herzindex, der systemische Gefäßwiderstand und der arterielle Mitteldruck signifikant unterschiedlich. Der MAP vor Narkoseeinleitung korrelierte mit dem Abfall des arteriellen Druckes während der Narkoseeinleitung (r = 0,6674, p 〈 0,001). Das Ausmaß der arteriellen Hypotension während der Narkoseeinleitung ist unabhängig vom präoperativen intravasalen Volumendefizit und wird hauptsächlich durch die Höhe des arteriellen Mitteldruckes vor Narkoseeinleitung bestimmt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Herz-, Thorax- und Gefässchirurgie 12 (1998), S. 54-57 
    ISSN: 0930-9225
    Keywords: Schlüsselwörter Herz-Lungen-Transplantation – Graft-versus-Host-Disease – zytolytische Therapie ; Key words heart-lung-transplantation – Graft-versus-Host-Disease – cytolytic therapy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary We report on a 28 year-old woman with congenitial ventricleseptum defect and Eisenmenger-reaction who developed acute GvHD on 10th postoperative day after successfull heart lung transplantation. The patient died on the 34th postoperative day of dissociated brain death after intracerebral bleeding.
    Notes: Zusammenfassung Wir berichten über eine 28-jährige Patientin, die aufgrund eines Ventrikelseptumdefektes (VSD) mit Eisenmengerreaktion und nachfolgender Herzinsuffizienz NYHA-Stadium IV herz-lungen-transplantiert wurde und an den Folgen einer akuten GvHD am 34. postoperativen Tag verstarb.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Herz-, Thorax- und Gefässchirurgie 13 (1999), S. 215-220 
    ISSN: 0930-9225
    Keywords: Schlüsselwörter Herz-Lungen-Maschine ; Sepsis ; Procalcitonin ; Key words Heart lung machine ; sepsis ; procalcitonin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The use of extracorporal circulation in open heart surgery causes profound stimulation of proinflammatory reaction. Therefore, timely diagnosis of infectious complications may become extremely difficult, and a more reliable marker of sepsis under these circumstances is needed.  We measured the new marker for sepsis Procalcitonin (PCT) in two distinct groups of patients exposed to extracorporeal circulatory devices. Group VAD consisted of 38 patients in end-stage heart failure supported with ventricular assist devices (VAD) Type Berlin Heart. Group EEC included 713 patients undergoing standard open heart surgery procedures. PCT was measured before operation and daily thereafter. PCT levels before operation were able to identify patients in cardiogenic shock who after device implantation died of infectious complications. Patients on VAD who showed elevated PCT levels before heart transplantation had a very unfavorable outcome. In the ECC group, none of the patients had elevated PCT levels before surgery. On day one after the procedure PCT was elevated in those patients who in their further postoperative course developed complications. Patients without PCT elevation after open heart surgery had an uncomplicated recovery.  Under the conditions of cardiogenic shock as well as the use of extracorporeal circulation, PCT is able to identify bacterial and fungal infections. It is helpful in evaluating the transplantability of patients on VADs. PCT seams to be unaffected by the use of extracorporeal circulatory circuits. However, a substantial number of patients exhibit PCT increase after ECC, and the PCT level has some prognostic value. The increase of PCT may be due to intestinal malperfusion.
    Notes: Zusammenfassung Der Einsatz der extrakorporalen Zirkulation führt zu einer erheblichen Stimulation der proinflammatorischen Reaktion. Dies kann bewirken, daß die zeitgerechte Diagnosestellung einer Infektion postoperativ erschwert wird und zeigt den Bedarf nach einem zuverläßigeren Sepsismarker in der postoperativen Phase nach herzchirurgischen Eingriffen.  Wir bestimmten den neuen Sepsismarker Procalcitonin (PCT) in zwei unterschiedlichen Patientengruppen, die jeweils dem Kontakt mit extrakorporalen Kreislaufsystemen ausgesetzt waren. Die erste Gruppe (VAD-Gruppe) bestand aus 38 Patienten mit terminalem Herzversagen, die mit einem ventrikulären Unterstützungssystem Typ Berlin Heart versorgt wurden. Die zweite Gruppe (EKZ-Gruppe) bestand aus 713 Patienten, die einem konventionellen herzchirurgischen Operationsverfahren unterzogen wurden. PCT wurde vor Operation und täglich nach der Operation gemessen. In der VAD-Gruppe waren die präoperativen PCT-Werte in der Lage, Patienten im kardiogenen Schock zu identifizieren, die nach der Operation an einer Infektion verstarben. Darüberhinaus hatten die Patienten, die vor Herztransplantation immer noch erhöhte PCT-Werte aufwiesen, eine schlechte Prognose nach Transplantation.  In der EKZ-Gruppe hatte kein Patient erhöhte PCT-Werte vor Operation. Patienten mit erhöhten Werten am ersten postoperativen Tag hatten eine hohe Inzidenz von Komplikationen in ihrem weiteren Verlauf, während Patienten ohne PCT-Erhöhung einen unkomplizierten Verlauf nahmen.  Sowohl bei Patienten mit kardiogenem Schock als auch nach Einsatz der Herz-Lungen-Maschine ist Procalcitonin in der Lage, bakterielle und pilzbedingte Infektionen zu identifizieren. Daher kann es zur Beurteilung der Transplantabilität von Patienten an Kreislaufunterstützungssystemen herangezogen werden. Der PCT-Wert scheint vom Blutkontakt zu Fremdoberflächen nicht beeinflußt zu werden. Allerdings zeigen eine Reihe von Patienten nach herzchirurgischen Routineeingriffen einen PCT-Verlauf. Die Komplikationsinzidenz ist in dieser Gruppe deutlich erhöht. Möglicherweise ist der PCT-Anstieg auf eine intestinale Minderperfusion während der extrakorporalen Zirkulation zurückzuführen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Herz-, Thorax- und Gefässchirurgie 14 (2000), S. 117-130 
    ISSN: 0930-9225
    Keywords: Schlüsselwörter Magnetresonanztomographie ; Künstliche Herzklappe ; Sicherheit ; Key words Magnetic resonance ; heart valve prosthesis ; safety
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The indications for magnetic resonance imaging (MRI) on prosthetic heart valve recipients remain critical. A generalized contraindication for MRI is doubtful. Some diagnostic questions such as interests in pathologies of the posterior cranial fossa, spinal abscesses, and internal derangements for the knee, strongly recommend the advantages of MRI versus all other radiological diagnostic techniques. MRI can directly affect patients with prosthetic valves in three ways by: 1) movement or dislodgment of the prosthesis, 2) heating, and 3) arrhythmias induced by electric currents, and indirectly by distortion of the image and its subsequent misinterpretation. Present literature that concerns the safety considerations of current values appears to be incomplete.    Therefore, a survey of twenty-five valve manufacturers with regard to compatibility, safety or contraindication for MRI on their respective prosthetic heart valves was performed in 1998. Those manufacturers who distribute most of the valves in Europe confirmed the safety of MRI. However, some gave their assurances based on inadequate data, or assigned all responsibility to the physician. Some companies did not give any assurance for MRI safety or failed to respond to our enquiry. Two valve manufacturers warned against performing MRI on certain prostheses. Based on our 1998 questionnaire, the technical issues, the clinical circumstances, the prerequisites and criteria for and the definition of safety standards for MRI on prosthetic heart valve recipients are presented in this paper.
    Notes: Zusammenfassung Die Indikationen zur Magnetresonanztomographie (MRT) bei Trägern künstlicher Herzklappen sind kritisch. Eine generelle Kontraindikation gegen die MRT ist zweifelhaft. Einige diagnostische Fragestellungen wie Prozesse in der hinteren Schädelgrube, Spinalabszesse und bei Beschwerden im Inneren des Knies lassen sich durch die MRT besser untersuchen als mit anderen radiologischen Verfahren. Die MRT kann Träger künstlicher Herzklappen auf dreierlei Weise direkt beeinträchtigen: 1) Bewegung und Dislozierung der Klappenprothese, 2) Erwärmung und 3) Induktion von Arrhythmien durch elektrische Ströme, und indirekt durch eine Verzerrung des MRT-Bildes mit der Gefahr einer diagnostischen Fehlinterpretation. Die gegenwärtige Literatur über Sicherheitsaspekte der MRT bei Trägern künstlicher Herzklappen erscheint nicht ausreichend.    Deshalb wurde 1998 eine Umfrage unter fünfundzwanzig Herstellern künstlicher Herzklappen durchgeführt bezüglich der Kompatibilität, Sicherheit, oder der Kontraindikation der MRT ihrer jeweiligen Klappenprothese. Die in Europa führenden Klappen-Hersteller bescheinigten eine MRT-Sicherheit. Einige Firmen stützten ihre Aussagen auf nicht einzusehende Untersuchungen, oder übertrugen die Verantwortung auf den Arzt, der die MRT durchführt. Andere Firmen gaben keine MRT-Sicherheitsgarantie oder antworteten nicht. Zwei Klappenhersteller warnten explizit vor der MRT bei bestimmten Prothesentypen. Aufbauend auf unsere Umfrage wird ein Überblick über die technischen Aspekte, die klinischen Umstände und die Voraussetzungen für MRT-Sicherheitsstandards bei Trägern künstlicher Herzklappen gegeben.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Herz-, Thorax- und Gefässchirurgie 14 (2000), S. 89-90 
    ISSN: 0930-9225
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Herz-, Thorax- und Gefässchirurgie 12 (1998), S. 121-129 
    ISSN: 0930-9225
    Keywords: Schlüsselwörter Aorta – Verkalkung – Röntgen – Computertomographie – Herzchirurgie ; Key words Aorta – calcification – radiography – computed – tomography – cardiac surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Purpose: Severe aortic calcification may complicate or even preclude cannulation of the ascending aorta, cross clamping, and insertion of bypass grafts. We set out to determine the incidence of aortic calcifications and to define predictors of operative complications. Methods: In a prospective evaluation of 100 consecutive candidates for open-heart surgery, we checked the pa and lateral chest radiographs for 11 indicators of aortic calcification. Patients with severe calcification were referred for spiral computed tomography (CT) with 3-dimensional reconstruction of aortic calcifications and echocardiography. Results: Evidence of aortic calcification was found in 70 patients (70%). In 4 patients, intraoperative complications due to aortic calcification were encountered. In one patient, surgery could not be completed. All 4 patients displayed linear calcifications of the ascending aorta on the lateral chest film. In another patient with CT proof of a completely calcified ascending aorta, aortic valve replacement was not attempted. In patients without linear calcifications of the ascending aorta, cardiopulmonary bypass could be instituted without problems. Radiographic features on the pa film were less sensitive and not specific for intraoperative complications. Echocardiography detected the lesion in 4/5 cases of severe calcification, but underestimated the extent of disease in 3 patients. CT predicted the intraoperative findings accurately in all 5 cases. Conclusions: Linear calcification of the ascending aorta on lateral chest radiographs is a both sensitive and specific predictor of intraoperative complications. 3D spiral CT facilitates surgical planning in such pateints. Careful preoperative screening may help to avoid exposing inoperable patients to the risk of thoracotomy.
    Notes: Zusammenfassung Zielsetzung: Verkalkungen der thorakalen Aorta können die Kanülierung oder das Abklemmen der Aorta aszendens und die Anlage von aortokoronaren Bypassgefäßen erschweren oder sogar verhindern. Ziel unserer Untersuchung war es, die Häufigkeit aortaler Verkalkungen bei herzchirurgischen Patienten zu erfassen und Kriterien zu bestimmen, die operative Komplikationen vorhersagen lassen. Methodik: In einer prospektiven Untersuchung wurden die p.a. und seitlichen Röntgen-Thoraxbilder von 100 konsekutiven Patienten (mittleres Alter: 65 Jahre, Spanne 43–87 Jahre, 34 Frauen) auf 11 Kriterien einer Aortensklerose hin untersucht. Alle Patienten waren für einen operativen Eingriff am offenen Herzen vorgesehen. Patienten mit Zeichen einer fortgeschrittenen Aortensklerose wurden zusätzlich mit der Spiral-Computertomographie (CT) und der Echokardiographie untersucht. Die CT-Abbildungen wurden durch dreidimensionale Rekonstruktionen ergänzt. Egebnisse: Bei 70 Patienten fanden sich Zeichen der Aortensklerose (70%). Intraoperative Komplikationen traten bei 4 Patienten ein. Bei einem Patienten konnte die geplante Operation nicht durchgeführt werden. Alle vier Patienten zeigten im seitlichen Röntgenbild des Thorax lineare Verkalkungen der Aorta aszendens. Bei einer fünften Patientin mit computertomographisch bestätigter weitgehender Verkalkung der Aorta aszendens wurde der geplante Aortenklappenersatz wegen dieses Befundes abgelehnt. Patienten ohne lineare Verkalkungen der Aorta aszendens im seitlichen Röntgenbild konnten ausnahmslos ohne Probleme operiert werden. Die Zeichen einer Aortensklerose im p.a. Röntgenbild waren in Bezug auf operative Komplikationen weniger sensitiv und weniger spezifisch. Echokardiographisch wurde die Aszendenssklerose in vier von fünf Fällen diagnostiziert, das Ausmaß der Verkalkung jedoch in drei Fällen unterschätzt. Die CT gab in allen fünf Fällen die operativ gefundenen Verhältnisse wieder. Schußfolgerungen: Lineare Verkalkungen der Aorta aszendens im seitlichen Röntgenthoraxbild stellen einen hochsensitiven und spezifischen Indikator zu erwartender operativer Komplikationen dar. Die 3D-Spiral-CT ermöglicht bei solchen Patienten eine weitgehende Operationsplanung. Eine aufmerksame präoperative Untersuchung herzchirurgischer Patienten auf Verkalkungen der thorakalen Aorta erlaubt es, inoperablen Patienten die Thorakotomie zu ersparen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Herz-, Thorax- und Gefässchirurgie 12 (1998), S. 140-143 
    ISSN: 0930-9225
    Keywords: Schlüsselwörter Heparinreduzierte Thrombozytopenie – künstliche Unterstützungssysteme – Orgaran – Herztransplantation ; Key words Heparin-induced thrombozytopenia – assist device – Orgaran – heart transplantation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Heparin-induced Thrombocytopenia (HIT) is a life threatening complication of anticoagulatory therapy with Heparin. We report on a 35 year old patient suffering from cardiomyopathy for whom a biventricular assist device (Berlin Heart) became necessary. This patient developed a HIT Type II postoperatively and was treated with Orgaran, an effective Heparin substitute in a patient with HIT Type II. After 213 days with the biventricular assist device our patient sucessfully underwent orthotopic heart transplantation with Orgaran. This medication can also be administered to assist device patients and can also be used as an anticoagulant during cardiopulmonary bypass.
    Notes: Zusammenfassung Eine heparininduzierte Thrombozytopenie (HIT) ist eine lebensgefährliche Komplikation bei einer antikoagulatorischen Therapie mit Heparin. Wir berichten von einem 35jährigen Patienten, der an einer dilatativen Kardiomyopathie litt und bei dem, infolge einer akuten kardialen Dekompensation, ein biventrikuläres Unterstützungssystem (BVAD, Berlin Heart) implantiert werden mußte. Dieser Patient entwickelte postoperativ eine HIT Typ II und mußte mit Orgaran (Orgaran; Danaparoid Org 10172, AKZO-Organon, Niederlande) behandelt werden. Schließlich konnte der Patient nach 213 Tagen mit mechanischer Kreislaufunterstützung erfolgreich mit Orgaran an der HLM transplantiert werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0930-9225
    Keywords: Schlüsselwörter Vorhofflimmern – Maze-Operation – chirurgische Therapie ; Key words atrial fibrillation – maze procedure – surgical therapy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary This case report describes a 62 years old patient who suffered from therapy resisten atrial fibrillation for 12 years. She underwent “Cox/Maze-III-Procedure” during a mitral valve reconstruction and a stable sinus rhythm was achieved. Two years after operation she has been in a stable sinus rhythm. Transesophageal echocardiography revealed normal cardiac dimensions and function with coordinated atrioventricular contractility. Therefore the therapy with anticoagulants and antiarrhythmics could be discontinued.
    Notes: Zusammenfassung Diese Fallvorstellung beschreibt der Verlauf einer 62jährigen Patientin mit seit 12 Jahre bestehendem, therapieresistentem Vorhofflimmern. Während einer Mitralklappenrekonstruktion erhielt sie eine “Cox/Maze-III-Operation”. Zwei Jahre postoperativ befindet sie sich im stabilen Sinusrhythmus. Es bestehen weder subjektive Beschwerden noch ließen sich Arrhythmien im Langzeit- und Belastungs-EKG nachweisen. In der transösophagealen Echokardiographie zeigte sich eine normale Herzgröße und -funktion mit koordinierten atrioventrikulären Kontraktionen, so daß die antikoagulative und antiarrhythmische Therapie beendet werden konnte.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-1238
    Keywords: Key words Cardiopulmonary bypass ; Coronary artery bypass graft ; Valve surgery ; Thoracic aortic surgery ; Prognosis ; Hypotension ; Systemic inflammatory response syndrome (SIRS) ; Procalcitonin ; Endotoxin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: To investigate procalcitonin (PCT) levels in patients undergoing cardiopulmonary bypass (CPB) in order to assess the prevalence and prognostic capacity of elevated PCT levels following CPB in open heart surgery.¶Design: prospective observational study in consecutive patients.¶Setting: Twenty-four-bed ICU, department of thoracic and cardiovascular surgery, university hospital.¶Patients: Seven hundred and twenty two patients, 691 of whom underwent CPB, i. e., 476 had coronary bypass surgery (CABG), 130 valve replacement, 34 combined CABG and valve replacement, and 23 thoracic aortic surgery.¶Interventions: Standard perfusion techniques were used with cardioplegic arrest and mild hypothermia (28–32 °C). With the exception of thoracic aortic procedures, full–flow perfusion was performed.¶Measurements and results: PCT was measured prior to surgery and daily thereafter until ICU discharge or death. PCT significantly increased at day 1 postoperatively compared to baseline values (0.25 ± 1.65 vs 6.49 ± 22.0 ng/ml, p 〈 0.005). However, in 55.1 % of patients PCT was below 1.0 ng/ml. In 12.8 % of CABG patients PCT was increased to 〉 5.0 ng/ml, compared to 39 % in valve patients and 35 % of patients with aortic surgery. An elevated PCT level 〉 1.0–5.0 ng/ml at day 1 was highly predictive of mortality (P 〈 0.03, vs 〈 1.0 ng/ml), with an additional accuracy when levels 〉 5.0 ng/ml were measured (P 〈 0.002 vs 〈 1.0 ng/ml).¶Conclusions: These results provide evidence that PCT might serve as an early prognostic marker in patients undergoing CPB in open heart surgery. It may be worth considering immunomodulating approaches in patients presenting elevated PCT levels in the early phase after CPB.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...