Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1540-8183
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The occlusion of patent ductus arteriosus (PDA) by Gianturco coils has been performed in a growing number of patients since its introduction at the beginning of this decade. The procedure is considered to be effective and safe. Yet embolization of the coil into the pulmonary artery system and residual shunting are typical complications. In some cases a coil loop may protrude into the aortic or pulmonary artery lumen and thus may result in flow disturbances. We report a case of thrombus formation on an intraaortic coil loop after retrograde embolization of a PDA in an adult.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of interventional cardiology 5 (1992), S. 0 
    ISSN: 1540-8183
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Balloon angioplasty of the coarctation of the aorta can result in intimal or medial or even adventitial dissections as demonstrated by in vitro studies and animal experiments. As a typical sign of stretching of the aortic wall, patients complain of pain during the angioplasty procedure. In the literature, aortic wall rupture and ventricular fibrillation during the procedure are reported. Additional sudden deaths can occur within 40 hours after the procedure. Mortality ranges from 0.1% to 2.5%. By transesophageal echocardiography, monitoring of balloon angioplasty, control of the positioning of the balloon, and control of the results and detection of complications are possible. Intimal as well as medial dissections can be detected with observed healing for intimal but also medial dissections. In order to avoid the patient's discomfort, intraaortic ultrasound will be used in the future, when major methodological improvements are done. Computed tomography demonstrates medial dissections but is not able to visualize intimal dissections. Using computed tomography and magnetic resonance after angioplasty of the coarctation of the aorta, irregularities are described in up to 17% of the patients. For angiography, a low detection rate of medial dissections has to be expected, when not biplane angiographies of the whole thoracic aorta are performend. Medial dissections can be seen, but intimal dissections are missed. In conclusion, a review of the literature demonstrates a high incidence of intimal and medial dissections after angioplasty of the coarctation of the aorta with spontaneous healing in most patients. As is the way with coronary angioplasty, aortic wall ruptures are rare, but stand-by surgery is necessary.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of cardiac surgery 9 (1994), S. 0 
    ISSN: 1540-8191
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The classical triad of sudden devastating chest pain, electrocardiographic absence of acute myocardial Infarction, and Identification of an upstream flap in the ascending aorta by transesophageal echocardlography (TEE) Indicates aortic type A dissection requiring emergent surgery. Among 34 patients presenting with clinical signs and symptoms of an aortic dissection, three did not show the mandatory flap in the upstream aorta. The only echocardlographic finding was aortic wall thickening Indicating an intramural hematoma. Two of these patients showed early aortic ectasia and one showed a pericardial effusion. Despite the missing flap echocardiographlcally, surgery was performed in all three patients. The surgical approach was the same as that for patients with a type A dissection. Two patients are doing well after the procedure, and one patient died after reoperation. The postoperatlve histologic work-up confirmed that there was no intimal tear or dissection of the intimal layer. We conclude that the echocardiographic finding of an Intramural hematoma combined with typical clinical signs of chest pain, with myocardial infarction ruled out, requires emergent surgical intervention. (J Card Surg 1994;9:508–515)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Contact dermatitis 47 (2002), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: In-stent restenosis is a complication which impairs the success of coronary stenting. Recently, it was supposed that a delayed hypersensitivity reaction to nickel and molybdenum might be one of the triggering factors in in-stent restenosis. We have analyzed the data collected in our centre with respect to this hypothesis. Altogether, 34 patients were investigated (24 male, 10 female). Patch tests were performed with the standard series of the German Contact Dermatitis Research Group and a metal series containing the metal components of 316 L stainless steel. A positive patch test reaction to nickel was observed in 4 (11.8%) patients. None of the patients showed sensitization to the other metals. Retrospective analysis was performed in 20 patients: 2 of these patients had a positive patch test reaction to nickel, one of whom had an in-stent restenosis, and the other not. Restenoses were predominantly observed in patients with negative patch test reactions to nickel (6/18 patients). Out of the patients who were investigated prospectively only one showed sensitization to nickel. Restenosis was observed in 2 patients: neither patient had nickel allergy. Although it still cannot be excluded that metal allergy may play a role in the restenosis process in coronary stenting, there is at present little evidence for it.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0022-2828
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    The international journal of cardiovascular imaging 2 (1986), S. 21-30 
    ISSN: 1573-0743
    Keywords: transesophageal echocardiography ; valve surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary In 17 patients (10 patients with mitral insufficiency, 5 patients with tricuspid regurgitation, 2 patients with mitral stenosis) the result of valve reconstruction was evaluated by intraoperative two-dimensional transesophageal contrast-echocardiography (TEE). Therefore, 1–2 cc of an agitated contrast-medium (GelifundolR) were injected into the left or right ventricle. The result of reconstruction was assessed by the extent of regurgitant microbubbles into the left or right atrium. A successful valve repair could be demonstrated in 15 patients without or with only minimal regurgitation of contrast-fluid. In one patient residual severe mitral insufficiency after valve reconstruction could only be detected when valve function was examined by contrast-TEE in the beating heart. An intraoperative decision for valve replacement was made. In another patient, mild to moderate residual mitral incompetence was shown; no further surgical intervention was done. By TEE the function of reconstructed valves can be examined under physiological conditions in the beating heart. Surgeons can obtain additional intra-operatively information and certainty about the result of reconstruction and an early decision for valve replacement can be made if necessary.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1573-0743
    Keywords: myocardial perfusion ; coronary flow reserve ; densitometry ; digital subtraction angiocardiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary From densitometric evaluation of digital subtraction cineangiocardiograms the parameter ‘Mean Rise Time’ (MRT), defined as the time from the onset of local myocardial contrast medium opacification to the point of maximal opacification can be derived; this parameter revealed a close correlation with the results on myocardial perfusion obtained by Thallium-201 scintigraphy. A prolonged ‘Mean Rise Time’ was indicative of an impairment of myocardial perfusion. We have developed a heart-phase gated real-time digitization procedure and computer-supported method for the densitometric estimation of the MRT to obtain information about the effect of coronary balloon dilatation on myocardial perfusion before and after stimulation of coronary flow reserve by Moxaverin. In 22 patients with single vessel coronary artery disease Moxaverin caused a significant prolongation of the post-stenotic MRT (2.3±1.2s (mean ± s.d.) vs. 2.9±1.1s, p〈0.05), while after successful dilatation of the obstructive lesion a significant shortening of the MRT was found after stimulation of the coronary flow reserve (2.5±1.2s vs. 1.9±0.9s, p〈0.05). A highly significant decrease in MRT after Moxaverin was measured post-dilatation in comparison to the initial pre-dilatation results (2.9±1.1s vs. 1.9±0.9s, p〈0.005); this shows that the effect of successful balloon dilatation on the post-stenotic myocardial perfusion can be described very well by this parameter. These results demonstrate that information about post-stenotic myocardial perfusion during interventional heart catheterization can be obtained from digital densitometry.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    The international journal of cardiovascular imaging 3 (1988), S. 111-116 
    ISSN: 1573-0743
    Keywords: coronary angiography ; low and high definition video systems ; digital imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We evaluated the requirements on spatial resolution of digital imaging equipment in the cardiac catheterization laboratory. Fifty cinefilms of the heart as the biological object and one film of a lead — ladder — pattern as an objective test were used. The patient films were examined for the visibility of the left ventricular angiogram, coronary arterial tree, coronary artery lesions, branching of septal arteries and the number of septal arteries. All films were viewed three times: with a 625 line TV-system, with a 1249 line TV-system and with a cineprojector. It was found that two application areas with different demands on the spatial and temporal resolution can be distinguished: 1) low spatial resolution and high temporal resolution, e.g. left ventriculography; and 2) high spatial resolution and low temporal resolution, e.g. coronary arteriography. For the diagnostic assessment of the state of the coronary system, the spatial resolution provided by the 1249 line TV-system was sufficient. Exceeding this resolution by using cinefilm quality provided no additional diagnostic information. A frame rate lower than 50 frames per second for coronary arteriography seems possible.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1432-0584
    Keywords: Intracoronary stenting ; Aggressive anticoagulation ; Subacute occlusion ; Bleeding complication ; Prothrombin fragment 1+2
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Patients with intracoronary stent implantation are treated with aggressive anticoagulant and antiplatelet therapy consisting of high-dose heparin, phenprocoumon, acetylsalicylic acid, dipyridamole, and the infusion of dextran to prevent a subacute thrombotic occlusion of the stented segment. In an effort to optimize this treatment by reducing both imminent bleeding complications and subacute thrombotic occlusion, the concentrations of prothrombin fragment 1+2 (F1+2) were determined after intracoronary Palmaz-Schatz stent implantation in 19 consecutive patients. The F1+2 concentrations after stent implantation and before the initiation of oral anticoagulant therapy (OAT) were 0.35 nm/l and 0.25–0.53 nm/l (median and 25th–75th percentile), versus 0.74 nm/l and 0.52–0.78 nm/l, in healthy subjects and 0.61 nm/l and 0.30–1.02 nm/l in 15 patients with ongoing proximal DVT. Nine days after initiation of OAT, F1+2 concentrations in both patient groups had not yet reached levels observed in patients with OAT in the stable state (0.16 nm/l, 0.12–0.26 nm/l;n=76;P〈0.0001 compared with healthy subjects; INR 2.0–4.5). Despite an INR greater than 2.0, accompanying heparinization was terminated on day 9. In two stented patients a minor bleeding complication arose after the removal of the arterial catheter. Subacute thrombotic occlusions were not observed. Since F1+2 concentrations did not exceed the upper limit of normal range (1.11 nm/l) in any of the 19 patients, the therapeutic regimen was not changed. Monitoring F1+2 may thus be helpful in introducing a more individual treatment if aggressive anticoagulation has to be performed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 13 (1978), S. 103-111 
    ISSN: 1432-1041
    Keywords: Digitoxin ; β-acetyldigoxin ; plasma levels ; cardiac performance ; dose-effect relationship ; 86-Rb-erythrocyte assay ; systolic time intervals
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary An inter-individual, randomized, double-blind study of digitoxin (Dt) and β-acetyl digoxin (D) was performed in 120 healthy male volunteers. Groups of 10 persons each received orally D 0, 0.1, 0.2, 0.3, 0.4, 0.5 or 0.6 mg and Dt 0.04, 0.08, 0.12, or 0.16 mg daily for 7 days; Loading doses were given for the first three days. Plasma levels were measured with an86Rb-erythrocyte assay 24 h after the last dose. ECG, carotid artery pulse and phonocardiogram were recorded prior to (b) and 24 h after (a) the last dose. QTc, amplitude of T-waves in V2 to V6, electromechanical systole (QS2c) and left ventricular ejection time (LVETc) were measured. The differences between a and b (Δ-values) reflect glycoside-induced changes in heart function. The plasma glycoside concentrations depended on dose and ranged from 0 to 2.4 ng/ml for D and from 0 to 42 ng/ml for Dt. QTc, QS2c, and LVETc were significantly shortened by the glycosides and typical parallel, sigmoid, log dose-response curves were obtained for the Δ-values. Dt was 3.8-times as potent as D in diminishing these parameters. The maximal effect of the two glycosides was almost identical at the highest doses: Δ-QTc=−45 ms, Δ-QS2c=−25 ms, Δ-LVETc=−12.5 ms. The latter two parameters showed a plateau of maximum efficacy. Both glycosides caused significant flattening of T-waves, Dt being 7.2-times as potent as D. Significant relationships between plasma concentration and cardiac effects were observed (p〈0.001)−Δ-QTc (D: r=0.7; Dt: r=0.77), Δ-QS2c (D: r=0.7; Dt: r=0.75), and Δ-LVETc (D: r=0.46; Dt: r=0.43); D correlated less well than Dt with the flattening of T (r=0.46; r=0.76, respectively). The most important conclusions were that: Dt was about 4-times as potent as D in influencing cardiac performance; the effects of D and Dt on systolic time intervals reached a plateau at “therapeutic” doses; Dt induced more pronounced flattening of the T-wave than D; and plasma glycoside levels within the “therapeutic” range corresponded to observed effects on the heart.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...