    Keywords: Key words Large atrial septal defects – interventional occlusion – Amplatzer Septal Occluder – follow-up ; Schlüsselwörter Große Vorhofseptumdefekte – Interventioneller Verschluss – Amplatzer Septal Occluder – Nachbeobachtung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Viele verschiedene Systeme für den Verschluss von Vorhofseptumdefekten (ASD) kamen in den letzten Jahren zum Einsatz, deren Gebrauch meist auf Defektgrößen bis 20mm Durchmesser limitiert war. Wir berichten über unsere klinische Erfahrung beim Verschluss von ASD mit einem Durchmesser größer 20 mm mit dem Amplatzer Septal Occluder (ASO).¶   Methode: Ein im Defekt platzierter Ballonocclusionskatheter wurde soweit inflatiert, dass eine Kerbe im Ballon als Grundlage für die echokardiografische als auch radiologische Bestimmung des gedehnten Durchmessers entsteht. Ein ASO¶2–4mm größer als der gedehnte Durchmesser wurde durch 9–12 French messende lange Schleusen implantiert. Im Unterschied zum Verschluss kleinerer Defekte wurde der ASO erst nach vollständiger Entwicklung des linksatrialen Schirmchens und des Verbindungsstents unter Ausnutzung der maximalen Auflagerungsfläche und Zentrierungseigenschaft in den Defekt gezogen, danach der rechtsatriale Schirm entfaltet und durch zügiges Vorschieben der Schleuse und des Implantationsdrahtes in Richtung Septum aktiv konfiguriert. Eine Implantation wurde nur durchgeführt, wenn der den Defekt umgebende Rand außer aortal, anterior minimal 7mm maß. Nach Implantation wurde mit einem extensiven „Minnesota wiggle” die mechanische Stabilität des ASO überprüft. Eine Freisetzung erfolgte nur, wenn kein oder nur minimaler Restshunt durch den zentralen Verbindungsstent im Farbdoppler zu erkennen war, ansonsten erfolgte eine konsequente Repositionierung.¶   Ergebnisse: Von 352 Patienten (P) mit interventionellem ASD-Verschluss mit einem ASO hatten 70 P (Alter 1,1–77,3 J) einen Defekt größer 20 mm (Median 22 mm (20–36), 25/75% Quartile = 20/26 mm). Der mittlere Shunt betrug Qp:Qs 2,1:1 (0,7–3,9:1), mittlere Durchleuchtungszeit 10,9 min (0–63). Ein vollständiger Verschluss war bei 85,7/93,1/100% der P nach 3 Monaten, ¶1 und 2 Jahren zu beobachten. Außer den 3 P mit chronischem Vorhofflimmern hatten nur 5P passagere Arrhythmien, 2 periprozedural und 3 innerhalb der ersten 3 Monate nach Verschluss, behandelt mit β-Blocker. Bei einem P kam es wegen eines ungenügend ausgebildeten posterioren Randes zur Akutembolisation des ASO mit nachfolgender chirurgischer Explantation und Defektverschluss. Trotz des „Überdimensionierens” des ASO kam es zu keiner Fehlkonfiguration des Implantats.¶   Schlussfolgerung: Der Verschluss von Vorhofseptumdefekten mit einem Durchmesser größer 20mm ist ohne höhere Komplikationsrate sicher und effektiv durchführbar, wenn man die modifizierten Implantationskriterien berücksichtigt. Passagere Arrhythmien stellen keine besondere Problematik dar.
    Notes: Summary Over the last few years, various devices for the interventional closure of atrial septal defects (ASD) up to a diameter of 20mm have been developed. We report our clinical experience in closing ASD with a diameter larger than 20mm diameter with the Amplatzer Septal Occluder (ASO).¶   Method: The stretched diameter of the ASD was measured by inflating a sizing balloon within the defect until an indentation in the circumference in the balloon could be observed. An ASO with a stent diameter 2–4mm larger than the indentation in the circumference of the balloon was chosen and implanted via 9–12 French sheaths. In contrast to the closure of smaller defects, pullback of the device onto the atrial septum was only performed when the connecting stent of the ASO was completely deployed in order to achieve maximal centering characteristics and optimal support of the retention skirt of the left atrial disc on the edges of the defect. Only then was the right atrial disc deployed and actively configured by advancing the sheath and the delivery cable against the atrial septum. Implantation was only attempted if the atrial septal rims (except the anterior rim around the aorta) measured more than 7mm by echocardiography to avoid injury or disturbance of sensitive intracardiac structures. After placement, the fixation of the device and the mechanical stability was proven by an extensive “Minnesota wiggle”. The ASO was released only when TEE showed no or a trivial residual color flow through the connecting stent; otherwise repositioning was performed.¶   Results: Out of 352 patients (P) with successful closure of interatrial defects, 70 P (age: 1.1–77.3 years) had stretched defects larger than 20mm diameter (median 22mm diameter (20–36), 25/75% quartiles=20/26mm). Mean shunt size was Qp:Qs 2.1:1 (0.7–3.9:1), mean fluoroscopy time 10.9min (0–63). Complete closure could be achieved in 85.7/93.1/100% after 3 months, ¶1 and 2 years, respectively. Besides 3P with persistent atrial fibrillation, only 5 P showed transient atrial tachyarrhythmias, 2 only periprocedural and 3 within the first 3months after implantation were treated with β-blocker. In one patient, an acute embolization of the device occurred because a diminished posterior rim was not visualized by a monoplane TEE probe necessitating surgical explantation and defect occlusion. Despite oversizing the device, no “mushrooming” misconfiguration were observed.¶   Conclusion: Transcatheter closure of large atrial septal defects with the Amplatzer Septal Occluder is feasible, safe and effective. Risk of complications do not seem to occur more frequently than after closure of smaller defects if one adheres to certain sizing and implantation measures. The incidence of transient atrial tachyarrhythmias seems to be low.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Kardiologie 89 (2000), S. 1126-1132 
    ISSN: 1435-1285
    Keywords: Key words Congenital heart disease – low weight infant – preterm infant – cardiac catheterization – transcatheter intervention ; Schlüsselwörter Herzfehler – Hypotrophe Neugeborene – Frühgeborene – Herzkatheter – Interventionen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Hintergrund: Immer noch stehen Neonatologen und Pädiater einer invasiven kardiologisch-kardiochirurgischen Behandlung von unreifen und sehr kleinen Neugeborenen mit einem angeborenen Herzfehler zurückhaltend gegenüber, da eine hohe Morbidität und Mortalität befürchtet wird. Methode: Retrospektive Analyse der Ergebnisse der in unserer Klinik im Herzkatheterlabor invasiv behandelten Patienten mit einem KG bis 2500 g im Zeitraum von Januar 1994 bis April 1999. Es erfolgten 69 Eingriffe bei 53 Patienten, davon 42 diagnostische Herzkatheteruntersuchungen (HK) bei 29 Patienten sowie 27 Interventionen bei 24 Patienten. ¶   Ergebnisse: In 33% (n=9) der 27 Interventionen konnte eine Operation vermieden (n=7) bzw. auf einen späteren Zeitpunkt ¶(KG≤3000 g, jenseits des 3. Lebensmonats) verschoben (n=2) werden. Dies gelang u.a. durch Dilatation einer Pulmonalklappenstenose (n=4), einer Aortenklappenstenose (n=1) und einer Aortenisthmusstenose (n=1). Eine Stabilisierung der hämodynamischen Situation war bei 14 Patienten möglich – ein antegrader pulmonaler Fluss wurde bei 5, ein effektiver interatrialer Shunt bei 3 Patienten geschaffen, 3 Patienten erhielten einen Stent in den Ductus arteriosus. Bei allen diagnostischen und interventionellen Untersuchungen traten in 9% der Fälle reversible Rhythmusstörungen (4 supraventrikuläre Tachykardien, 2 ventrikuläre Tachyarrhythmien) auf, bei 30% der arteriellen Untersuchungen gab es behandlungsbedürftige Gefäßprobleme. Es gab keine Todesfälle. Schlussfolgerungen: Herzkatheteruntersuchungen und -interventionen können auch bei einem KG≤2500 g mit einer vertretbaren Komplikationsrate durchgeführt werden. Katheterinterventionen können Operationen ersetzen, den erforderlichen Operationszeitpunkt verschieben oder die Ausgangsbedingungen für notwendige Operationen verbessern. Dabei sollten für eine Intervention dieselben Indikationen wie bei den eutrophen Neugeborenen gelten.
    Notes: Summary Background: Pediatricians and neonatologists are still reluctant to consider invasive cardiological or cardiosurgical treatment in low body weight infants because it is believed to considerably increase the risk. The aim of this study was to assess the results and complications of percutaneous transcatheter interventions in infants with a weight below 2.5 kilograms. ¶   Methods: Retrospective analysis was undertaken for all patients with a weight below 2.5 kilograms who underwent cardiac catheterization from 01/1994 to 04/1999. During this time 42 diagnostic catheterizations in 29 patients and 27 transcatheter interventions in 24 patients were performed. ¶   Results: Surgery was replaced or effectively postponed in 9 (33%) out of 27 transcatheter interventions. This was possible for pulmonary stenosis, valvular aortic stenosis and aortic coarctation. A stabilization of the hemodynamic situation was possible in 14 patients. An antegrade pulmonary flow was established in 5, an effective interatrial shunt created in 5 and the arterial duct stented in 3 patients. Only 3 patients had no benefit from the intervention; however, there were no deaths nor hemodynamic complications. Arrhythmias occurred in 9% of all catheterizations and interventions but were transient in all cases. Femoral arterial complications were observed in 30% of all arterial catheterizations. ¶   Conclusion: Diagnostic cardiac catheterization and percutaneous transcatheter interventions can be performed with low mortality and acceptable morbidity in low weight infants. Transcatheter interventions can replace surgery, postpone the necessity for surgery or stabilize the hemodynamic situation prior to surgery.