  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 56 (1985), S. 830-832 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: An array of 64 silicon surface-barrier diodes on a circular arc view Tokamak Fusion Test Reactor (TFTR) plasmas through a slot aperture to provide poloidal imaging of x-ray emission in the 200 eV–15 keV range. Information is inferred on magnetohydrodynamic (MHD) instabilities, disruptions, radiation, impurity transport, electron temperature, and electron thermal conductivity. Spatial resolution is 2.5 cm. Movable absorber foil arrays provide energy selection. Preamplifier–amplifier pairs have gains of 0.05–100 V/μA. Two outputs are provided with (1) 40-, 80-, and 300-Hz and (2) 40-, 80-, and 600-kHz filtering. The signals are digitized at rates up to 500 kHz and stored in 128K (total system) memory. Foils, gains, and filters are selectable from the control room by a computer.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 56 (1985), S. 349-354 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: In order to carry out x-ray observations of magnetohydrodynamic wave activity of the plasma during DD and DT (deuterium-beam-heated deuterium and tritium plasmas, respectively) operation of the Tokamak Fusion Test Reactor (TFTR), we will need detectors not susceptible to nuclear radiation damage. We have investigated the use of gridded ionization chambers as fast nondamageable x-ray detectors. A prototype chamber is described which was tested on the PDX tokamak. These tests and laboratory tests with a pulsed x-ray source suggest that the detector has sufficient sensitivity and speed for the required measurements.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The x-ray pulse-height analysis (PHA) diagnostic uses a liquid-nitrogen cooled array of 5 Si(Li) and one HpGe detectors to do time-resolved (5–100 ms) x-ray spectroscopy of the central horizontal chord of the Tokamak Fusion Test Reactor (TFTR) plasmas in the 1–50-keV range. Central electron temperature Te and concentration of medium and low-Z impurities are derived from the spectra. Remotely selectable absorber-foil arrays provide selection of the energy range. Fixed and movable aperture arrays allow approximate equalization of count rates in different energy bands and extend dynamic range. Amplifier pulse shapes are approximately triangular. Main amplifier peaking time is 4 μs yielding 230-eV FWHM at 5.9 keV. Pileup inspection times are selectable at 0.13, 0.4, or 0.9 μs. Throughput is up to 42 kHz. The PHA has been used to study temperature and impurities over a wide range of TFTR operational parameters. Dramatic variations in metal impurities with density, plasma current, and major radius have been observed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...