Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 79 (1996), S. 3608-3610 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Based on the capacitance–voltage (CV) characteristics of semiconductor metal-insulator- semiconductor (MIS) heterostructures and the nonparabolic characteristics of narrow-gap semiconductors (NGSs), a surface potential model has been developed to derive subband structures of two-dimensional electron gas systems in an inversion layer of NGS MIS heterostructures. CV measurement was also performed on a p-type InSb MIS heterostructure, and two onsets of electron filling more than one subband were observed. Subband structures were also obtained using the presented potential model. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Phytochemistry 30 (1991), S. 1710-1711 
    ISSN: 0031-9422
    Keywords: Rubia cordifolia ; Rubiaceae ; iridoid glycoside. ; roots
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 73 (2000), S. 98-104 
    ISSN: 1432-1246
    Keywords: Key words Passive sampler ; 2-Methoxyethanol ; Field evaluation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: This paper presents a field evaluation of 3 M 3500 passive badges for measuring 2-methoxyethanol (ME) in a humid working environment. Methods: A total of 93 pairs of side-by-side active/passive samples, 48 pairs of duplicate active samples, 52 pairs of duplicate passive samples, and three groups of six replicate active/passive samples were compared. Three groups of six replicate active charcoal/active charcoal tube with drying tube samples were also compared to evaluate the humidity effect. Results: No statistical difference was found between the passive badges and active samplers. Linear regression showed the correlation to be high (r = 0.992, slope  =  0.973, n = 93) over the range of 0.17–163 ppm. The mean concentration difference was −0.34 ppm and the mean relative error was 3.50%. The intraclass correlation coefficients of 48 duplicate active samples and 52 duplicate passive samples were 0.994 and 0.989, respectively. The precision of replicate passive, active, and active/drying tube samples (n = 6) were 3.84%, 7.14%, and 5.12%, respectively. Conclusions: The humidity effect for active samples was insignificant at the low sampling rate (36.3 ml/min). It is therefore concluded that the use of the passive samplers to assess ME exposure produces comparable findings to that of active sampling.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...