Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 1012-1014 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: For the European spallation source, a volume source based on the high efficiency source is being developed. The source will be optimized to produce high current densities in pulsed operation. A pulse generator delivering 1–1.5 ms pulses was installed. Furthermore, cesium was supplied to the plasma generator from an external oven. The cesium injection was optimized for a low e/H− ratio and a high current. We obtained a current density of 70 mA/cm2. This way, with an aperture radius of 4.25 mm, an H− current of 40 mA was extracted at an extraction voltage of 22 kV. After a description of the source and the experimental setup, measurements of the beam current density and the e/H− ratio will be presented in this article. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 2698-2706 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Among the various possibilities for investigating the properties of ion beams, two of the most important principles for determining the beam quality are profile measurements using wires or slit apertures, and different kinds of emittance measurement devices. However, most of the commonly used systems have the disadvantage of being either destructive to the beam, or at least to have a considerable influence on the further beam propagation downstream of the point of measurement. Also, for the investigation of intense ion beams, thermal problems on the scanners themselves might arise. Observation of particles emitted from the ion beam in radial direction allow an indirect but nondestructive observation of the beam. Of the different optical methods that exist to accomplish this, we recently conducted an investigation on the possibilities to employ a charge coupled device-camera system for such nondestructive beam diagnostics in our space-charge compensation test stand. First, experimental results on optical profile measurements are presented and compared to results obtained by a slit scanner and a wire scanner. Additionally, to gain a better understanding of the measured data, optically obtained sectional profiles behind a slit and a circular aperture were analyzed. Possibilities for gaining information on the two-dimensional beam profile and the beam emittance are explored. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1039-1041 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A new version of the high efficiency source is being developed for the European Spallation Source. The goal of these experiments is to produce a nearly pure H− ion beam with a low electron to H− ratio and high current (70 mA). To achieve this, the discharge chamber is divided into two parts of different plasma parameters by means of a filter magnetic field. Furthermore, the plasma chamber is aligned unsymmetrically with respect to the z axis of the extractor. We obtained a current density of 10 mA/cm2 for an arc power as small as 1 kW. In preliminary experiments, a beam of 10 mA was extracted at an extraction voltage of 8 kV (1.8% impurities). Measurements of the beam current density, electron to H− ratio, and the ion composition for a wide range of discharge conditions will be presented in this article. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1054-1056 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A volume source, based on the high efficiency ion source (HIEFS), is being developed for D+ production in steady state operation. The source will be optimized for the extraction of atomic deuterium ions with high current densities. It was found that a maximum deuterium ion beam current density of 210 mA/cm2 can be achieved with a D+ fraction above 90%. At an extraction voltage of 35 kV and with an aperture radius of 4 mm, the source delivers 61 mA D+. After a description of the source and the experimental setup, the results of detailed studies of the beam composition in dependence of the plasma parameters are presented. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 1066-1068 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A volume source based on the high efficiency source is being developed for heavy ion production. Bismuth was chosen for exemplifying investigations because of its low melting point. The ion source is driven by an arc discharge ionizing bismuth atoms which are evaporated from an oven inside the source chamber. It has been optimized to produce a beam with a fraction of singly ionized bismuth above 92%. A multiaperture extraction system was built consisting of seven holes with a radius of 3 mm each. For that system, the perveance limit was achieved at a beam current of 70 mA and an extraction voltage of 27.5 kV. The corresponding emission current density amounts to 35 mA/cm2. This value was obtained for an arc power of only 280 W. Furthermore, the emittance of a beam extracted from the multiaperture extraction system has been determined with a high power emittance scanner. It amounts to 0.27π mm mrad (80%, normalized, 4 rms). In this case, the emittance of a single beam is 0.017π mm mrad. This article will give a detailed description of both the source and the experimental setup. In addition, various dependencies between the plasma parameters and the beam composition are presented. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Macromolecules 28 (1995), S. 1003-1007 
    ISSN: 1520-5835
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 41 (1952), S. 83-95 
    ISSN: 1437-1596
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Notes: Zusammenfassung Die Geschmacksdifferenz für Phenylthiocarbamid, einMendelsches Merkmal, dessen Erbweise durch umfangreiche Untersuchungen größerer Bevölkerungsgruppen sowie durch Zwillings- und Familienuntersuchungen gesichert und bekannt ist, wird bedingt durch ein Genpaar Gg. Die Anwesenheit von G bedingt den bitteren Geschmack für Phenylthiocarbamid: Gg oder GG. Bei Abwesenheit von G wird Phenylthiocarbamid als geschmacklos empfunden: gg. Die gerichtsmedizinische Bedeutung ergibt sich aus der Tatsache, daß aus einer Elternverbindung, in der beide Phenylthiocarbamid nicht schmecken, nur nichtschmeckende Kinder zu erwarten sind. Die wenigen bisher bekannten Ausnahmen lassen sich entweder durch Fehlbestimmungen oder bei Familienuntersuchungen durch Illegitimität erklären. Bei der gerichtsmedizinischen Bestimmung der Geschmacksdifferenz für Phenylthiocarbamid ist zu berücksichtigen: a) Es sollen gleichzeitig und kreuzweise Kontrollbestimmungen mit abgestuften Lösungen von Chininsulfat und Saccharin so durchgeführt werden, daß die zu untersuchende Person nicht weiß, welche Substanz geprüft wird. b) Eine Ermüdung ist durch längere Pausen während der Untersuchung zu vermeiden. c) Die Bestimmung ist vor dem 6. Lebensjahre unsicher und deshalb nicht auswertbar. d) Es bestehen Unterschiede in der Empfindlichkeit für Phenylthiocarbamid auf der rechten und linken Zungenseite. e) Es kann schwierig Sein, schwache Schmecker sicher von Nichtschmeckern abzugrenzen. f) Bei lokalen Erkrankungen der Mundhöhle, Zahnlosigkeit, künstlichem Zahnersatz einschließlich großen Metallbrücken ist ebenso wie bei Allgemein- oder Nervenerkrankungen aus Sicherheitsgründen das Merkmal nicht verwertbar, vor allem, wenn es um die Bestimmung eines Nichtschmeckers geht. Der Ausschluß eines bestimmten Mannes allein auf Grund der Geschmacksdifferenz gegen Phenylthiocarbamid, theoretisch möglich, sollte praktisch, wenigstens vorläufig, nicht ausgesprochen werden, außer wenn durch weitere Merkmale die Erzeugerschaft unwahrscheinlich ist. Die Entdeckung weiterer genabhängiger Geschmacksdifferenzen eröffnet gerichtsmedizinisch neue Ausschlußmöglichkeiten.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Bundesgesundheitsblatt, Gesundheitsforschung, Gesundheitsschutz 42 (1999), S. 77-84 
    ISSN: 1437-1588
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Darüber hinaus soll das Lebensmittel-Monitoring längerfristig dazu dienen, zeitliche Trends in der Belastung von Lebensmitteln aufzuzeigen und eine ausreichende Datenbasis zu schaffen, um Aufnahmeberechnungen von unerwünschten Stoffen, die der Verbraucher über die Nahrung aufnimmt, durchführen zu können.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 40 (1950), S. 76-87 
    ISSN: 1437-1596
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Notes: Zusammenfassung Nach eingehender Untersuchung der Organe eines Todesfalles durch akute Benzinvergiftung, verglichen mit den bisher aus dem Schrifttum bekannten Tatsachen unter Berücksichtigung früherer eigener Beobachtungen, lassen sich in der Hauptsache folgende Feststellungen treffen: 1. Der chemische Nachweis höherer (Benzin) Kohlenwasserstoffe ist 24 Stunden nach der überlebten Vergiftung nicht mehr möglich. 2. Die Möglichkeit, histologisch eine Benzinvergiftung nachzuweisen, ergibt sich aus dem komplexen Befund von Lunge, Niere, Muskel und Gehirn. 3. Zwischen Lungenbefund und Resorptionsdauer des Benzins bestehen direkte Beziehungen. 4. Das hämorrhagische interstitielleintraalveoläre Ödem der Lunge bei maximaler Hyperämie ist für die Benzinvergiftung kennzeichnend. 5. Nach primärer Lipoidbildung im Gehirn tritt unter starker Zunahme sudanpositiver Fette ein fixer Pettabbau ein, der mit dem Abbau chromotroper Lipoide und einem perivasalem Ödem zusammengeht. 6. Die fettige Degeneration der Ganglien- und Gliazellen ist universell. 7. Nach Benzinvergiftung sind Spätschäden am Gehirn zu erwarten. 8. Die Bedeutung topistischer Faktoren wird hervorgehoben.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 28 (1950), S. 179-184 
    ISSN: 1432-1440
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Zusammenfassung In funktionellen und morphologischen Untersuchungen der Nebenniere des Meerschweinchens unter langdauernder 3%iger CO2-Einwirkung ergeben sich abgesehen von der unmittelbaren Bedeutung der CO2-Wirkung für Funktion und Morphologie der Nebenniere wichtige Zusammenhänge zwischen Rinde und Mark. Die funktionelle Untersuchung ergab, daß nach langdauernder CO2-Wirkung 1. der Adrenalingehalt quantitativ abnimmt; 2. Ferrosalzgaben, die bei kurzfristiger CO2-Einwirkung eine Adrenalinentleerung hervorrufen, keine Wirkung mehr haben; 3. Adrenalininjektionen nur noch eine geringe Blutzuckersteigerung auslösen; 4. der Blutzucker absinkt; 5. die Blutzuckerkurve nach Glucoseinjektion flach verläuft. Die morphologische Untersuchung ergab, daß nach langdauernder CO2-Wirkung 1. die Chromierbarkeit der Markzellen abnimmt; 2. die großvacuoligen Markzellen mit den großvacuoligen Rindenzellen zusammengehen: 3. die Z. reticularis mit anhaltender CO2-Wirkung zunimmt; 4. der Zustand, wie er nach 17 Tagen CO2-Einwirkung vorliegt, zunächst über eine Phase gesteigerter Tätigkeit geht, die nach 5 Tagen CO2-Wirkung langsam abnimmt. Die Zweiphasigkeit der CO2-Wirkung kommt sowohl funktionell wie morphologisch zum Ausdruck.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...