Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (9)
  • 1980-1984  (3)
  • 1960-1964  (3)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Radiation and environmental biophysics 19 (1981), S. 305-305 
    ISSN: 1432-2099
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2099
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Notes: Abstract An experimental setup using static-field gel electrophoresis (SFGE) was developed to determine radiation-induced DNA double-strand breaks (DSBs) in CHO-K1 cells after exposure to X-rays or heavy charged particles. The fraction of DNA eluted into the gel matrix depends on the quantity of DSBs introduced. In agreement with a recent report, SFGE and pulsed-field electrophoresis were found to be equally sensitive in DSB detection. With radiolabeled DNA from cell cultures, the absolute amount of DNA migrating out of agarose plugs into the gel was quantified by determining the radioactivity in the gel lane. Alternatively, relative measurements of the amount of DNA released into the gel were achieved with a standardized protocol for both SFGE and a subsequent densitometric scanning of photographic negatives from gels stained with ethidium bromide. After calibration with the radioactive method, the fractions of DNA retained could be calculated directly from the data obtained with the densitometric assay to set up classical dose-effect curves. This procedure was validated for its application with heavy ions using an 500 MeV/u lead beam.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Radiation and environmental biophysics 31 (1992), S. 117-121 
    ISSN: 1432-2099
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Notes: Summary X- and gamma-irradiation of human erythrocyte membranes (250–1000 Gy) was found to decrease the ratio of weakly to strongly immobilized signal height of membrane-bound maleimide spin label (Mal-6). Subsequent incubation of spin-labeled membranes at ambient temperature (21 °C) induced a progressive increase in this ratio, faster for membranes irradiated with low doses which was hampered by protease inhibitors. These results demonstrate that ionizing radiation stimulates proteolysis of erythrocyte membrane proteins by membrane-associated proteases.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Radiation and environmental biophysics 31 (1992), S. 161-180 
    ISSN: 1432-2099
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Notes: Summary Swift heavy ions when penetrating through matter strip off those electrons having a smaller orbital velocity than the ion velocity. The remaining electrons screen the nuclear charge yielding an effective charge. The effective charge of the ions interacts predominately with the target electrons causing excitation and ionizations of the target atoms. Using the Bethe Bloch formula for the energy loss combined with the Barkas formula for effective charge, the energy loss values as well as unrestricted and restricted linear transfer can be calculated within a few percent of accurancy. From the primary energy loss only a small fraction of 10% or less is transformed into excitation. The major part of the energy loss is used for the ionization of the target atoms and the emission of the corresponding electrons with a high kinetic energy. These electrons form the track around the trajectory of the primary ion in which two thirds of the primary energy is deposited by collisions of primary, secondary and later generations of electrons with the target molecules. In the electron diffusion process the energy is transported from the center of the track into the halo. The radial dose decreases with the square of the radial distance from the center. The diameter of the track is determined by the maximum range of the emitted electrons, i.e. by the maximum energy electrons. All ions having the same velocity i.e. the same specific energy produce electrons of the same energy and therefore tracks of the same diameters independent of the effective charge. But the dose inside the track increases with the square of the effective charge. Track structure models using this continuous dose distributions produce a better agreement with the experiment than models based on microdosimetry. The critical volume as used in microdosimetry is too large compared to the size of the DNA as critical structure inside the biological objects. Track structure models yield better results because the gross-structure of the track i.e. its lateral extension and the thin down toward the end of the track is included in these calculations. In a recent refinement the repair capacity of the cell has been included in a track structure model by using the complete shouldered x-ray survival curve as a template for the local damage produced by the particle tracks. This improved model yields presently the best agreement with the experiment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-2099
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Notes: Abstract The effect of high linear energy transfer (LET) radiation on DNAin vitro, both in protective and non-protective environments was investigated. Two hydroxyl radical scavengers, tris(hydroxymethyl) aminomethane and 2-mercaptoethanol, were compared for their ability to protect SV40 DNA from radiation damage over a wide LET range. At comparable OH scavenging capacities, significant differences were found between these protective agents, indicating that other, radical scavenger-dependent processes affected the extent to which the DNA was protected. In general, a decrease in single-strand breaks (SSBs) relative to double-strand breaks (DSBs) was observed as LET increased. This effect was more pronounced when a radioprotector was present. Comparison of the relative biological efficiency (RBE) of radiation damage as LET increased showed a peak of DSB production in the mid-LET range. These data agree with measurements made by Christensen et al. (1972). An explanation for this increase in DSB production efficiency has been proposed based on the particle track structure of high-LET radiation.Correspondence to: G. Taucher-Scholz
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Radiation and environmental biophysics 33 (1994), S. 91-109 
    ISSN: 1432-2099
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Notes: Abstract A Monte Carlo model is presented to study details of the energy deposition inside tracks of heavy charged particles in water vapor. The input data for most of the calculations based on the binary encounter approximation are double-differential cross sections for electron emission after heavy-ion impact. The paths of the liberated electrons are simulated, taking into account elastic scattering, ionization, and excitation. Each basic interaction of an electron or heavy ion is treated individually. Radial dose distributions and specific energy deposition are calculated for projectiles from protons to uranium in the energy range from one to several hundred megaelectron volts per unified atomic mass unit. Good agreement with measurements in tissue-equivalent gas and propane is obtained for light and medium-heavy projectiles, whereas for heavy projectiles such as uranium, deviations around a factor of 2–3 are observed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Radiation and environmental biophysics 19 (1981), S. 296-296 
    ISSN: 1432-2099
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Radiation and environmental biophysics 33 (1994), S. 233-241 
    ISSN: 1432-2099
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Notes: Abstract Human erythrocytes were irradiated with heavy ions of energies between 4 and 18 MeV/u having linear energy transfer (LET) values between 92 and 14000 keV/µm. Hemolysis has been studied as a macroscopic parameter for membrane damage and changes of the fluidity as a more microscopic parameter. The membrane fluidity changed in a characteristic dose-dependent manner as detected by electron spin resonance employing 12-doxylstearic acid methyl ester spin label (SL 12). Lysis cross sections and RBE values were determined from dose effect curves. The results demonstrate a high hemolytic efficiency of heavy ions compared to X rays. With increasing LET values the measured relative biological efficiency (RBE) values increase continuously. In the complete LET range the cross sections formed one common curve as function of LET and no saturation effects are observed. This is in direct contrast to other biological endpoints such as cell inactivation or DNA damage.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 186 (1962), S. 187-193 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary This paper shows the possibilities for electrical indication of complexometric titrations, discussing in detail the potentiometry, amperometry, voltammetry as well as the conductometry. It furthermore deals with a new indication system by means of a polarized oxide electrode and reports on the first results obtained when using this system for titrating Bi.
    Notes: Zusammenfassung Es werden die Möglichkeiten für die elektrische Indikation komplexometrischer Titrationen aufgezeigt und dabei im einzelnen die Potentiometrie, die Amperometrie, die Voltammetrie und die Konduktometrie diskutiert. Über ein neuartiges Indikationsverfahren, das sich einer polarisierten Oxidelektrode bedient, wird berichtet; erste damit bei der Titration von Bi erhaltene Ergebnisse werden mitgeteilt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 197 (1963), S. 217-221 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The selective determination of metallic iron beside iron oxides may be carried out in a simple and rather accurate manner by treating the analysing sample with a solution of bromine in methanol. By this method, only the metallic iron is dissolved which, after filtering the oxides remained unsolved, may be determined by one of the known titrimetrical or photometrical procedures. The ferro-iron content of the oxide residue may appropriately be determined by the Vanadate titration method according to Wilson. Although a reaction with elementary chlorine at about 400°C quantitatively converts the metallic iron into FeCl3, it also transforms one third of the iron amount present in the form of ferrous oxide into the same compound. Consequently, this method is not suited for a direct determination of the metallic iron content although it affords a useful control of the sum: metallic iron + ferro-iron as obtained by the first mentioned method.
    Notes: Zusammenfassung Die selektive Bestimmung von metallischem Eisen neben Eisenoxiden ist in einfacher und recht genauer Weise durch Behandeln der Analysenprobe mit einer Lösung von Brom in Methanol durchzuführen. Es wird dabei lediglich das metallische Eisen gelöst, das nach Abfiltrieren der ungelöst bleibenden Oxide in bekannter Weise titrimetrisch oder photometrisch bestimmt werden kann. Der FeII-Gehalt des Oxidrückstandes kann am zweckmäßigsten nach dem Vanadat-Titrationsverfahren von Wilson bestimmt werden. Die Umsetzung mit elementarem Chlor bei etwa 400°C überführt zwar das metallische Eisen quantitativ in FeCl3, wandelt aber auch ein Drittel der als FeII-Oxid vorliegenden Eisenmenge in die gleiche Verbindung um. Somit ist dieser Weg für die direkte Bestimmung des Fe (met.)-Gehaltes nicht geeignet, stellt aber eine brauchbare Kontrolle der nach dem erstgenannten Verfahren erhaltenen Summe für Fe(met.) + FeII dar.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...