Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 123I-low-density lipoprotein  (1)
  • 81.60.Bn  (1)
  • 1
    ISSN: 1432-0630
    Keywords: 61.80.Ba ; 52.75.-d ; 81.60.Bn ; 76.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Armco iron samples were surface nitrided by irradiating them with pulses of an excimer laser in a nitrogen atmosphere. The resulting nitrogen depth profiles measured by Resonant Nuclear Reaction Analysis (RNRA) and the phase formation determined by Conversion Electron Mössbauer Spectroscopy (CEMS) were investigated as functions of energy density and the number of pulses. The nitrogen content of the samples was found to be independent of the number of pulses in a layer of 50 nm from the surface and to increase in depths exceeding 150 nm. The phase composition did not change with the number of pulses. The nitrogen content can be related to an enhanced nitrogen solubility based on high temperatures and high pressures due to the laser-induced plasma above the sample. With increasing pulse energy density, the phase composition changes towards phases with higher nitrogen contents. Nitrogen diffusion seems to be the limiting factor for the nitriding process.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of nuclear medicine 12 (1986), S. 291-292 
    ISSN: 1619-7089
    Keywords: Low-density lipoproteins ; Atherogenesis ; Imaging lesions ; 123I-low-density lipoprotein
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In patients suffering from clinically manifest atherosclerosis autologous LDL-labelling has been done using 123I. This technique allows localization of areas with an increased LDL entry as well as a monitoring of kinetics. Normally, no tracer uptake can be seen in the vascular system. Positive camera images, however, can be obtained in pathological areas as early as 60 min after LDL-reinjection. Experimental data and morphological control reveal a very good correlation to the gamma-camera findings. The technique seems to be very promising for diagnosis in patients suffering from atherosclerosis and hyperlipoproteinemia.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...