    European journal of nuclear medicine 11 (1985), S. 62-64 
    ISSN: 1619-7089
    Keywords: Ammonia ; Diagnosis ; Emission spectroscopy ; Isotope application ; Liver ; Nitrogen-15 ; Tracer technique ; Urea
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Malfunction of the liver involves disturbances of urea synthesis and ammonia detoxification. These phenomena became apparent, especially during ammonia loading of patients. The functional state of the liver can be assessed by oral administration of 15NH4Cl and subsequent analysis of 15N-urea and 15N-ammonia in urine by emission spectrometry. Clinical tests based on the ratio of the excess abundances (see Appendix) of 15N-ammonia to 15N-urea excreted in urine 3 h after oral administration gave values for patients with liver disease which differed significantly from those for healthy subjects. Absorption disturbances, which often accompany liver diseases, do not influence the effectiveness of the method.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of nuclear medicine 11 (1985), S. 58-61 
    ISSN: 1619-7089
    Keywords: Children ; Diagnostic techniques ; Diseases ; Drugs ; Function tests ; Isotope applications ; Liver ; Metabolism ; Nitrogen-15 ; Pregnant women ; Stable isotopes ; Urine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A simple, non-invasive, non-radioactive liverfunction test is proposed. After an oral dose of 3 mg 15N-methacetin per kilogram body mass, the kinetics of 15N excretion via urine were characterized by the quotient of the amounts of 15N excreted in two successive urine samples (Q value). The stable nitrogen isotope 15N was found to be an excellent and easily detectable indicator of the sum of all methacetin metabolites present in urine. Alterations in the nature or ratio of methacetin metabolites due to liver diseases could not be found. From the investigation of 11 men, 3 pregnant women and 15 children, a clear difference was observed in Q values of healthy persons and patients suffering from liver-cell-activity diseases. The discriminating power of our new liver-function test is shown to be equivalent to that of the 14CO2 breath test.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1434-601X
    Keywords: 23.40
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The half-lives of very neutron rich isotopes of Ni and Cu have been measured. The isotopes are produced in very asymmetric thermal fission of235U and239Pu at the I.L.L. high flux reactor. They are separated by means of the Lohengrin spectrometer. They are identified with aΔE-E ionization chamber and implanted in one of the 8 Si planar detectors where theβ-particles are also detected. The time correlations between the implantation and the detection ofβ-particles provide the half-life. The values obtained are compared to current theoretical predictions.