Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 31 (1983), S. 37-44 
    ISSN: 1432-0630
    Keywords: 79.20
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract The areal density and the depth distribution of3He trapped in Ni as a function of the bombarding fiuence was measured in the energy range of 1–25 keV and at angles of incidence between 0 and 85° using nuclear reaction analysis. At fluences below saturation a linear relation is found between the areal density and the fiuence. From its slope the trapping and reflection coefficients can be determined. The experimental data for trapping and reflection coefficients and for the depth profiles were compared with computer simulation results from the TRIM program. To reduce uncertainties in the absolute values of the experimental trapping coefficients, they were normalized to the TRIM values at normal incidence. The dependence of the measured reflection coefficient on the angle of incidence between 0 and 80° shows good agreement with the calculated data for incident energies from 3 to 25 keV, but for 1 keV the measured reflection coefficients are higher than the calculated ones.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 38 (1996), S. 322-324 
    ISSN: 1432-1920
    Keywords: Key words Demyelinating disease ; Sclerosis ; Brain ; Magnetic resonance imaging ; Computed tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report a case of Balò's concentric sclerosis. In the past, the diagnosis was usually made post mortem. In this case, we found that CT demonstrated only low-density lesions, but not their concentric pattern. However, MRI showed a striking feature, reminiscent of histopathology of Balò's concentric sclerosis, and played an important role in antemortem diagnosis of this rare demyelinating disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 40 (1998), S. 335-337 
    ISSN: 1432-1920
    Keywords: Key words Thyroid ; lingual ; Goitre ; Computed tomography ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We present the CT and MRI findings in a 75-year-old woman with a huge pathologically proven lingual thyroid which underwent goitrous degeneration. CT and MRI showed a midline, tongue-based, exophytic mass with areas of necrosis and heterogeneous contrast enhancement, as seen in large goitres in the normal thyroid gland.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 38 (1996), S. 322-324 
    ISSN: 1432-1920
    Keywords: Demyelinating disease ; Sclerosis ; Brain ; Magnetic resonance imaging ; Computed tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report a case of Balò's concentric sclerosis. In the past, the diagnosis was usually made post mortem. In this case, we found that CT demonstrated only low-density lesions, but not their concentric pattern. However, MRI showed a striking feature, reminiscent of histopathology of Balò's concentric sclerosis, and played an important role in antemortem diagnosis of this rare demyelinating disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 39 (1997), S. 811-814 
    ISSN: 1432-1920
    Keywords: Key words Meningeal melanocytoma ; Magnetic resonance imaging ; Computed tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report the MRI and CT findings of an intracranial meningeal melanocytoma (IMM) arising from Meckel's cave and review the imaging characteristics of IMM. On CT, IMM constantly appear as well-circumscribed, isodense to slightly dense, extra-axial tumours with homogeneous contrast enhancement. This appearance is nonspecific and similar to that of meningiomas or small neuromas. On MRI, the signal of IMM is strongly related to the amount of melanin pigment: the more melanin, the more shortening of T1 and T2 relaxation times. Only when it shows as a homogeneous mass, bright on T1 and dark on T2 weighting, can a specific diagnosis of a melanin-containing tumour be made. However, this still cannot provide a distinction between IMM and malignant meningeal melanoma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-1920
    Keywords: Key words Arachnoid granulations ; Computed tomography ; Magnetic resonance imaging ; Magnetic resonance venography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report MRI and angiographic findings of an unusual giant arachnoid granulation in the left sigmoid sinus in a boy with headache. Its signal intensity was lower than that of cerebral cortex on T1-weighted images and higher on T2 weighting, mimicking dural sinus thrombosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 33 (1984), S. 265-268 
    ISSN: 1432-0630
    Keywords: 79.20
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Trapping and particle reflection coefficients for 0.4–10keVD on graphite have been measured for angles of incidence 0≦α≦85° by determining the areal density of implanted D as a function of the implanted fluence. The experimental data are compared to computer calculations with the TRIM-program. The agreement between measurement and calculation is good.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...