Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1920
    Keywords: Multiple sclerosis ; Magnetic resonance imaging ; Brain ; Gadolinium ; Database
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The unique sensitivity of magnetic resonance imaging (MRI) in detecting disease activity in multiple sclerosis (MS) and the objective nature of the information obtained suggest that MRI will be a useful and reliable way of monitoring treatment trials. There is a need to develop an appropriate database which would provide a standardised means of assessment, not only of MRI, but also of essential clinical information. As part of the program of Concerted Action in Multiple Sclerosis, funded by the Commission of the European Community (CEC), we have developed a database for recording serial brain MRI results. The database consists of core, entry and follow-up sections. Both entry and follow-up parts are subdivided into clinical, MR system and MRI data. We expect that the use of this database will maximise efficiency of MRI monitoring in MS treatment trials, particularly in multicentre studies.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1459
    Keywords: Key words Multiple sclerosis ; Magnetic resonance imaging ; Disease activity ; Fast spin echo ; Fast fluid-attenuated inversion ; recovery ; Reproducibility
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Previous studies have addressed the question of the precision in assessing multiple sclerosis (MS) activity by counting enhancing lesions on gadolinium enhanced brain magnetic resonance imaging (MRI). However, counting the active lesions on serial unenhanced MRI obtained by various pulse sequences has not been yet considered. We compared the interobserver levels of agreement in reporting active MS lesions on serial enhanced and unenhanced MRI to assess whether the use of various unenhanced techniques may change the degree of interobserver measurement reproducibility. Dual-echo conventional spin echo (CSE), dual-echo fast spin echo (FSE), fast fluid-attenuated inversion recovery (FLAIR) and Gd-enhanced T1-weighted brain MRI were obtained from five MS patients at baseline and monthly for 2 months. Six experienced observers independently identified and counted active MS lesions on the two follow-up MRI scans. Active lesions were considered to be all the enhancing lesions and any new or enlarging lesion on enhanced and unenhanced scans. Interobserver levels of agreement were calculated by weighted κ values. Very good agreement was reached only for counting total and new Gd-enhancing lesions. Good agreement was achieved for counting new lesions on the three unenhanced techniques, whereas the agreement for counting enlarging lesions was poor with all the MRI techniques. The level of agreement was significantly heterogeneous for various MRI techniques but not for various lesion sites. These results confirm that counting enhancing lesions is the most reliable method for assessing MS activity, but the use of any of the available unenhanced MRI techniques did not result in different levels of interobserver agreement when reporting new and enlarging MS lesions on serial scans.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...