Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 31 (1983), S. 37-44 
    ISSN: 1432-0630
    Keywords: 79.20
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract The areal density and the depth distribution of3He trapped in Ni as a function of the bombarding fiuence was measured in the energy range of 1–25 keV and at angles of incidence between 0 and 85° using nuclear reaction analysis. At fluences below saturation a linear relation is found between the areal density and the fiuence. From its slope the trapping and reflection coefficients can be determined. The experimental data for trapping and reflection coefficients and for the depth profiles were compared with computer simulation results from the TRIM program. To reduce uncertainties in the absolute values of the experimental trapping coefficients, they were normalized to the TRIM values at normal incidence. The dependence of the measured reflection coefficient on the angle of incidence between 0 and 80° shows good agreement with the calculated data for incident energies from 3 to 25 keV, but for 1 keV the measured reflection coefficients are higher than the calculated ones.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 39 (1997), S. 446-449 
    ISSN: 1432-1920
    Keywords: Key words Arachnoid diverticula ; Spine ; Magnetic resonance imaging ; Gadolinium
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Our goal was to find MRI signs of use for identifying a spinal arachnoid diverticulum. Three cases of spinal arachnoid diverticula, one extradural and two intradural, were examined on a 1.5 T imager. There was obvious mass effect on the adjacent structures in one case and increased signal intensity in the diverticulum on proton density- and T2-weighted images in two cases. Signal changes due to turbulent movement of the spinal fluid inside the diverticula were seen in all cases on sagittal fast spin-echo (FSE) proton density- and T2-weighted images; it was difficult to tell whether these signal changes imply a communication or are simply FSE artefacts. On contrast-enhanced studies, all cases showed partial enhancement inside the diverticula. There thus are four signs of diverticula: mass effect, the increased signal, signal void sign and partial enhancement; the last of these, the most reliable, has never been reported before.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 38 (1996), S. S114 
    ISSN: 1432-1920
    Keywords: Key words Spine ; haemorrhage ; Gadolinium ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Spontaneous spinal epidural haematoma (SSEH) is uncommon, but central gadolinium (Gd) enhancement of the haematoma is even rarer. To our knowledge, only one case has been reported, but no explanation was given concerning the mechanism of this enhancement. We present a case of SSEH with unusual central Gd enhancement which we believe is due to oozing from the injured posterior internal venous plexuses. Therefore, although rare, central Gd enhancement of an epidural mass should not rule out the possibility of a haematoma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 38 (1996), S. S114 
    ISSN: 1432-1920
    Keywords: Spine, haemorrhage ; Gadolinium ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Spontaneous spinal epidural haematoma (SSEH) is uncommon, but central gadolinium (Gd) enhancement of the haematoma is even rarer. To our knowledge, only one case has been reported, but no explanation was given concerning the mechanism of this enhancement. We present a case of SSEH with unusual central Gd enhancement which we believe is due to oozing from the injured posterior internal venous plexuses. Therefore, although rare, central Gd enhancement of an epidural mass should not rule out the possibility of a haematoma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 33 (1984), S. 265-268 
    ISSN: 1432-0630
    Keywords: 79.20
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Trapping and particle reflection coefficients for 0.4–10keVD on graphite have been measured for angles of incidence 0≦α≦85° by determining the areal density of implanted D as a function of the implanted fluence. The experimental data are compared to computer calculations with the TRIM-program. The agreement between measurement and calculation is good.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...