Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1459
    Keywords: Acute myelopathy ; Magnetic resonance imaging ; Evoked potentials ; Multiple sclerosis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Brain and spinal cord magnetic resonance imaging (MRI), multimodal evoked potentials (EPs) and cerebrospinal fluid (CSF) analysis were performed in 27 patients with acute myelopathy of unknown aetiology (AMUA), to detect the diagnostic and prognostic values of paraclinical tests at presentation. Spinal cord MRI was abnormal in 56% and brain MRI in 33% of the patients. Visual EPs were abnormal in 7%, median somatosensory EPs in 17%, tibial somatosensory EPs in 56% and motor EPs in 35% of the cases examined. Brain-stem acoustic EPs were normal in all the patients. CSF oligoclonal bands (OBs) were detected in 30% of cases. The patients were divided into subgroups according to the short-term clinical outcome (complete, partial or absent recovery). There were no significant differences among the three groups as regards MRI findings. Patients with complete recovery showed a significantly lower frequency of tibial somatosensory EP and motor EP abnormalities. According to the paraclinical findings at onset and on the basis of a long-term clinical follow-up (mean duration 24 months), 6 patients were diagnosed as having clinically definite multiple sclerosis, while 21 did not develop further neurological disturbances. Only the presence of CSF OBs was significantly more frequent in patients with definite multiple sclerosis. Our study indicates that EPs exploring spinal cord function are more powerful than spinal MRI for predicting the short-term outcome of AMUA, while the combined use of brain MRI and CSF OBs has the highest negative predictive value for the subsequent development of clinically definite multiple sclerosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1459
    Keywords: Key words Multiple sclerosis ; Magnetic resonance imaging ; Disease activity ; Fast spin echo ; Fast fluid-attenuated inversion ; recovery ; Reproducibility
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Previous studies have addressed the question of the precision in assessing multiple sclerosis (MS) activity by counting enhancing lesions on gadolinium enhanced brain magnetic resonance imaging (MRI). However, counting the active lesions on serial unenhanced MRI obtained by various pulse sequences has not been yet considered. We compared the interobserver levels of agreement in reporting active MS lesions on serial enhanced and unenhanced MRI to assess whether the use of various unenhanced techniques may change the degree of interobserver measurement reproducibility. Dual-echo conventional spin echo (CSE), dual-echo fast spin echo (FSE), fast fluid-attenuated inversion recovery (FLAIR) and Gd-enhanced T1-weighted brain MRI were obtained from five MS patients at baseline and monthly for 2 months. Six experienced observers independently identified and counted active MS lesions on the two follow-up MRI scans. Active lesions were considered to be all the enhancing lesions and any new or enlarging lesion on enhanced and unenhanced scans. Interobserver levels of agreement were calculated by weighted κ values. Very good agreement was reached only for counting total and new Gd-enhancing lesions. Good agreement was achieved for counting new lesions on the three unenhanced techniques, whereas the agreement for counting enlarging lesions was poor with all the MRI techniques. The level of agreement was significantly heterogeneous for various MRI techniques but not for various lesion sites. These results confirm that counting enhancing lesions is the most reliable method for assessing MS activity, but the use of any of the available unenhanced MRI techniques did not result in different levels of interobserver agreement when reporting new and enlarging MS lesions on serial scans.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...