Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (144)
  • 2015-2019
  • 1990-1994  (46)
  • 1980-1984  (98)
  • 1970-1974
  • 1945-1949
  • 1820-1829
  • 1991  (46)
  • 1982  (98)
  • 1829
  • Gas chromatography
Source
  • Articles: DFG German National Licenses  (144)
Material
Years
  • 2015-2019
  • 1990-1994  (46)
  • 1980-1984  (98)
  • 1970-1974
  • 1945-1949
  • +
Year
  • 1
    ISSN: 1438-2199
    Keywords: Amino acids ; Cysteic acid analysis ; Taurine analysis ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We have reported preparations and gas chromatographic analyses of volatile derivatives of sulfuric acid and taurine (Masuoka et al., 1988; 1989). By extending these studies, we have developed a method for the gas chromatographic determination of cysteic acid. Cysteic acid was converted to the N-isobutoxycarbonyl derivative by the reaction with isobutyl chloroformate in the presence of sodium hydroxide. After desalting with a cation-exchange column, the derivative was converted to the silver salt by reacting with silver oxide. The resulting silver salt was quantitatively esterified with methyl iodide in the presence of dimethyl sulfate and silver oxide. Dimethyl N-isobutoxy-carbonylcysteate [methyl 2-(N-isobutoxycarbonylamino)-3-(methoxysulfonyl) propanoate] formed was analyzed by gas chromatography. The calibration curve was linear up to 5.0µmol per ml of cysteic acid and the recovery was more than 95%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1438-2199
    Keywords: Amino acids ; Nonprotein amino acids ; α-Aminoisobutyric acid ; Isovaline ; Screening procedure ; Gas chromatography ; Polypeptide antibiotics (peptaibiotics) ; Filamentous fungi
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Filamentous fungi of the genusHypocrea were grown on malt extract/peptone agar, the mycelia were extracted with dichloromethane/methanol, and the extracts were totally hydrolyzed with 6 N HCl (110°C, 24 h). The amino acids (AA) released from peptides were converted into theirN(O)-pen-tafluoropropionyl 1-propyl esters and investigated by gas chromatography and gas chromatography/mass spectrometry for the presence of the nonprotein AAα-aminoisobutyric acid (Aib) and its homologue isovaline (Iva). In particular Aib served as specific marker compound for a particular group of fungal peptides named peptaibiotics,i.e. peptides containing Aib and having antibiotic activities. Screening of 24 species ofHypocrea revealed that the majority was capable of producing peptaibiotics. The reliability of the screening procedure was shown with the isolation of peptaibiotics fromHypocrea muroiana andHypocrea nigricans. These findings extend the list of genera of fungi already known to produce Aib-containing peptides and also establish that Aib and Iva are fairly common in the biosphere.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 63 (1991), S. 27-31 
    ISSN: 1432-1246
    Keywords: Hemoglobin adducts ; Exposure control ; Gas chromatography ; Epoxides ; Alkenes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A method for monitoring exposure to ethylene oxide (EO) and propylene oxide (PO) and their corresponding alkenes through the analysis of adducts to N-terminal valine in hemoglobin (Hb) using gas chromatography (GC) and electron-capture detection has been developed. The method is a further development of the so-called N-alkyl Edman method, which has thus far been carried out using gas chromatography-mass spectrometry (GC/MS). The correlation between GC and GC/MS determinations of adduct levels in human samples was found to be good. The newly developed GC method enables the determination of adducts to Hb from EO and PO down to levels of about 100 pmol/g globin. This adduct level corresponds to the expected increment from ethene in inhaled tobacco smoke in a smoker of about 10 cigarettes/day or from an average exposure to about 50 Wpb EO or 1 Wpm PO during working hours.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 62 (1991), S. 603-606 
    ISSN: 1432-1246
    Keywords: Styrene ; Urinary metabolites ; Gas chromatography ; Occupational health
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary In support of an occupational investigation of styrene exposure, a capillary gas chromatographic method was developed for the quantitation of the styrene metabolites mandelic and phenylglyoxylic acids. The method was based on that of Guillemin and Bauer [7], in which phenylglyoxylic acid was converted to mandelic acid by reduction before instrumental analysis. The earlier method had to be modified for use with capillary columns; the resulting method was sensitive, selective and reproducible. The detection limit was approximately 0.001 mg/ml urine. Approximately 〈5% relative precision was achieved in the range of 0.05–2 mg/ml urine. Mandelic acid was resolved from other components of urine and from by-products of derivatization.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 63 (1991), S. 83-88 
    ISSN: 1432-1246
    Keywords: Toluene diisocyanate, TDI ; Toluenediamine, TDA ; Test chamber ; Gas chromatography ; Mass spectromety ; Biological monitoring
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Five men were exposed to toluene diisocyanate (TDI) atmospheres for 7.5 h. The TDI atmospheres were generated by a gas-phase permeation method, and the exposures were performed in an 8-m3 stainless-steel test chamber. The mean air concentration of TDI was ca. 40 μg/m3, which corresponds to the threshold limit value (TLV) of Sweden. The inhaled doses of 2,4- and 2,6-TDI were ca. 120 μg. TDI in the test chamber air was determined by an HPLC method using the 9-(N-methyl-aminomethyl)-anthracene reagent and by a continuous-monitoring filter-tape instrument. After hydrolysis of plasma and urine, the related amines, 2,4- and 2,6-toluenediamine 2,4-, and 2,6-TDA), were determined as pentafluoropropionic anhydride (PFPA) derivatives by capillary gas-chromatography using selected ion monitoring (SIM) in the electron-impact mode. The urinary elimination of the TDAs showed a possible biphasic pattern, with rapid first phases for 2,4-TDA (mean t 1/2 for the concentration in urine, 1.9 h) and for 2,6-TDA (mean t 1/2 for the concentration in urine, 1.6 h). The cumulative amount of 2,4-TDA excreted in urine within 28 h ranged from 8% to 14% of the estimated dose of 2,4-TDI, and the cumulative amount of 2,6-TDA in urine ranged from 14% to 18% of the 2,6-TDI dose. The average urinary level of 2,4-TDA was 5 μg/l in the 6 to 8-h sample (range 2.8–9.6 μg/l), and the corresponding value for 2,6-TDA was 8.6 μg/l (range, 5.6–16.6 μg/l). Biological monitoring of exposure to 2,4- and 2,6-TDI by analysis of 2,4- and 2,6-TDA in urine is feasible.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Archives of toxicology 65 (1991), S. 433-435 
    ISSN: 1432-0738
    Keywords: Analysis ; Blood ; Butoxyacetic acid ; 2-Butoxyethanol ; Gas chromatography ; Glycol ethers ; Man ; Renal clearance ; Toxicokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Venous blood samples from five male volunteers exposed to 20 ppm 2-butoxyethanol (BE) for 2 h were collected at 0, 2, 4, and 6 h from the start of exposure and analyzed by gas chromatography after simultaneous ion-pair extraction and derivatization with pentafluorobenzyl bromide. Butoxyacetic acid (BAA), a major metabolite of BE, was found in all samples except those collected prior to exposure. This is the first time to our knowledge that the analysis of BAA in human blood has been reported. Concentrations of BAA in blood ranged from 22 to 60 μM. These concentrations were about two orders of magnitude lower than those causing swelling and hemolysis of human erythrocytes in vitro. The BAA blood level peaked after 2–4 h. The decrease between 4 and 6 h indicates an average half-time of BAA in blood of about 4 h, which is in accordance with previously observed half-times in urine. The low renal clearance of BAA (22–39 ml/min) indicates extensive binding to blood proteins and poor tubular secretion of the substance. Binding of BAA to blood components is also indicated by the low apparent volume of distribution of approximately 151.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1573-5133
    Keywords: Polychlorinated biphenyl ; DDT ; Gas chromatography ; Mass spectrometry ; Crossopterygii
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Synopsis Gas chromatography coupled with electrolytic conductivity detection and electron capture negative chemical ionization mass spectrometry have been used to identify and quantify organochlorine xenobiotics in tissues from two specimens of the living coelacanth Latimeria chalumnae. Compounds identified include polychlorinated biphenyls (PCB), 4,4′-DDT and its metabolites 4,4′-DDD and 4,4′-DDE. Levels of these compounds in the specimens were observed to be generally related to tissue lipid content. Highest concentrations of the xenobiotics were present in the lipid-rich swim bladder, followed by adipose tissue and liver. Levels ranged from 89 to 510 μg kg−1 for PCB and 210 to 840 μg kg−1 for Σ-DDT (including DDD and DDE) on a wet-weight basis. Organochlorine concentrations in relatively lipid-poor tissues, i.e. muscle and kidney, were lower. Parent DDT contributed significantly to the Σ-DDT burden. PCB congeners containing five to seven chlorines were most prevalent. Component distributions did not match those present in common commercial PCB formulations. However, major congeners observed were similar to those reported for other fishes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 171-172 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Ethanolamines ; Ethylene glycols ; Wide-bore capillary column
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The GC separation of a mixture of three ethanolamines and four ethylene glycols without any preliminary derivatization, on a wide-bore capillary column coated with Carbowax 20M is described. These high-boiling and polar compounds elute giving simmetrical peaks and show good resolution. The analysis is completed in less than 14 minutes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 173-176 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Stationary phase optimization ; Mobile phase optimization ; Column temperature optimization ; Multifactor optimization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A computer-assisted method is presented for the simultaneous multifactor optimization (stationary phase loading, column temperature and carrier gas flow rate) of the analytical conditions for the optimum separation of multicomponent samples in gas chromatography. The optimization of the separation over the experimental region is based on a special polynomial from twelve preliminary experiments using the resolution as the selection criterion. Computer scanning technique was used for optimum selection in three dimensions. Excellent agreement was obtained between the predicted data and the experimental results.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 193-205 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Column liquid chromatography ; Silanol adsorption centres ; Strongly interacting adsorption sites ; Suppression of adsorption activity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In this second part of the review heterogeneity of the silica surface is described and evidence is presented for the existence of a low population of strong adsorption sites. Methods of detection and determination of these strongly interacting sites are discussed. The last part of the review is devoted to the suppression of unwanted adsorption activity. Methods of blockage and special methods for the preparation of HPLC packings are described.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 243-246 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Principal component analysis ; Wool wax alcohols ; Sterols
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Capillary gas chromatography with flame ionization detection has been applied to the separation of the components of wool wax alcohols. Twenty-six commercial and non-commercial (laboratory) samples were investigated. Twenty-eight components found in the samples were used as variables for further characterization by a chemometric procedure. Principal component analysis was applied to the differentiation of samples from different sources and obtained by different technologies.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Chemiluminescence detection ; Phosphine derivatives ; Headspace analysis ; Fluorine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Phosphine, alkylated phosphines and monophosphinate esters are detected with high sensitivity in capillary gas chromatography (GC) by their chemiluminescent reactions with molecular fluorine. Detection limits are estimated to be 1.3 pg, 0.5 pg, 8 pg, and 17 pg for phosphine, trimethyl phosphine, trimethyl phosphinate ester, and triethyl phosphine, respectively. As found earlier with alkylated sulfur, selenium and tellurium compounds, the detector exhibits a linear response. For triethyl phosphine, a linear range of greater than three orders of magnitude was demonstrated. Emission spectra were obtained for the trimethyl phosphine and triethyl phosphine systems. Chemiluminescence emitters include electronically excited HCF, vibrationally excited HF, and an unknown species in the trimethyl phosphine system. Banded emission from vibrationally excited HF and a broad continuum were observed for both trimethyl phosphine and triethyl phosphine; however, HCF emission was observed only for TMP. Under the conditions employed, the principal emitter is HCF for trimethyl phosphine and HF and the unknown emitter for triethyl phosphine. This detector may have important applications in investigations of the biogeochemical cycling of phosphorus.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 393-397 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Correlation chromatography ; Spark modulator injector
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A spark modulator has been tested as an injection system for correlation gas chromatography. An air/hydrocarbon vapour mixture was used as the carrier gas. Single negative sample injections were performed using a single spark period. The experiments resulted in negative sample peaks and a positive product peak. The intensity of all peaks showed a characteristic dependence on the spark frequency and power used. Ghostpeaks were absent when a correlation experiment was performed with a high concentration of a test compound in pure air. The signal to noise ratio enhancement however, was lower than the theoretical value. More experiments are necessary to expalain this phenomenon.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 457-464 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Organoclay stationary phase ; Bentone ; Ethylbenzene and xylene isomers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Several kinds of Bentones which have structures similar to Bentone 34 have been tested and compared for the purpose of improving the resolution of ethylbenzene and xylene isomers by gas chromatography. Bentone SD-3 was found to have higher selectivity toward these close-boiling compounds than the well known stationary phase Bentone 34. Modification effects of some conventional stationary phases which represent the whole range of polarity on the chromatographic property of Bentone SD-3 have been investigated and discussed. A number of new organoclays which have different structures of the organic cation in complexes have been synthesized and their properties evaluated for the separation of positional isomers. A simultaneously high selective organoclay for each component in the aromatic mixture of ethylbenzene and xylene isomers, without assistance of conventional stationary phases, has been described.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 453-456 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Organochlorine pesticides ; Polychlorinated biphenyls ; Solid phase extraction ; Mussels
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A multi-residue method for the determination of organochlorine pesticides and polychlorinated biphenyls (PCB's) in mussels (Mytilus sp.) is presented. After extraction with acetonitrile, pesticides and PCB's are separated from coextractives by liquid-liquid partition between acetonitrile and water/hexane. Further clean-up is performed using Sep-Pak Florisil cartridges eluting PCB's in the first eluate with hexane and organochlorine pesticides in the second eluate with 15% ethyl ether in hexane. Final determination is carried out by capillary gas chromatography with ECD. Detection limits for different pesticides and PCB's range from 0.02 to 0.3 μg kg−1 and recoveries from standards solutions treated in the same way as the samples averaged 91.5%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 500-504 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Amino acids ; Linearity ; Nitrogen-phosphorus detector
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A significant curvature of the detector response was observed when a Nitrogen-Phosphorus Detector (NPD) was used for the gas chromatographic determination of amino acids. Five calibration standards, over a 16 fold concentration range, were used to calibrate the NPD. A calibration curve of form y=axb was found to be suitable, with coerelation coefficients (r)〉0,997 for all 17 amino acids. A t-test was used to prove that b≠1, i.e. there was significant curvature. This calibration curve reduced calibration errors to less than 6%, compared to more than 40% for linear calibration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 32 (1991), S. 5-12 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Headspace sampling ; GC theory ; Influence of sample volume
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The role of the volume of the sample and the sample vial in equilibrium headspace-gas chromatography is discussed. A new term, thesample phase fraction (ΦS) is introduced. It is shown that if the value of ΦS is kept constant, the vial's volume has no influence on the “sensitivity” of the headspace analysis (which is proportional to the concentration of the analyte in the headspace). In a given headspace sampling system, concentration of the compound of interest in the headspace (c G * ) at equilibrium is related to the value of ΦS: a higher ΦS will increase c G * . However, the influence is important only in the case of low distribution coefficients: in the case of higher distribution coefficients this influence is negligible. This conclusion is also true for small changes in the sample volume in duplicate analyses: exact reproducibility of the sample volume is important only in the case of low distribution coefficient values.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 18
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Supercritical fluid extraction ; GC detectors ; Purity of gases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The usefulness of several grades of carbon dioxide for online supercritical fluid extraction/capillary gas chromatography has been studied. If trace-level work has to be performed, no single grade can be recommended for all modes of detection studied. Good-quality carbon dioxide is available for use with flame ionization and thermionic detectors. With electron-capture detection, however, distinct problems still exist.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 32 (1991), S. 579-582 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Flame gas analysis ; Low pressure sampling ; Gas syringes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new sampling technique is developed for flame samples taken at very low pressure (50 Torr absolute). This technique uses gas syringes. Analysis is by gas chromatography and the compounds of interest are the fixed gases and selected C1 and C2 hydrocarbons and chlorinated hydrocarbons. Linear response factors are obtained for all compounds. This is highly unusual for gas-phase chlorinated hydrocarbon sampling, which is very prone to sample absorption. The sources of experimental error unique to gas syringe use are identified and quantified. One error source is exacerbated by the very low sample pressure and requires special treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 20
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Linear temperature programming ; Calculation of retention indices
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Program temperature retention indices for fifteen nonalkane solutes have been determined by cubic splines, by other procedures found in the literature and by interpolation of the n-alkanes retention time logarithm for eleven temperature programs. A comparison in terms of variance of the differences between PTRI calculated by CS and each of the remaining methods is made for each of the eleven program runs, for each of the three stationary phases used and for many of the programs. The smallest variances obtained result when the Zenkevich, van den Dool & Kratz and Chen et al. methods are tested. The stationary phase polarity is of no relevance since it has no effect on the specific PTRI found by the different methods employed in this work.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 32 (1991), S. 211-214 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index of homologous series ; Chain rigidity ; Stationary phase polarity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The rule that addition of a CH2 group to a molecule increases the retention index by 100±3 is subject to a greater uncertainty than ±3 when (a) the stationary phase has very strong intermolecular attractions comparable to the nitriles and the analyte has a polar group in the 1-position, (b) the alkyl chain to which the CH2 is added has 3 or fewer carbons and (c) when a group that is remote from the end of the chain, such as an ester group or a double bond, introduces rigidity in that part of the chain. In cases (a) and (c), it is still true that the retention index increases linearly in a specific homologous series, but it may deviate from 100 units per carbon by as much as 10 or, in the case of nitrile stationary phases, may be as low as 70.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 32 (1991), S. 441-444 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; FID ; Volcanic gas emissions ; Light hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Volcanic gas emissions are strictly related to a specific stage of volcanic activity. Complete knowledge of their chemical composition can be extremely useful for efficient geochemical surveillance of active volcanism sites. A new, effective and simple method for the evaluation of light hydrocarbons in volcanic gases is described. A rapid sampling procedure and GC-FID analysis are employed. Data from different volcanic areas are shown and a their possible correlation is also discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 32 (1991), S. 457-460 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Cresol isomers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The analysis of isomeric cresols is difficult because of their similar volatilities and high polarities. The situation is specially complicated in the case of industrial synthesisplant samples because of the presence of phenol and of the very high concentration (about 90%) of p-cresol. A gas chromatographic method is described, employing columns packed with Bentone-34 plus Castorwax on diatomaceous supports; the best results are obtained using Chromosorb P AW DMCS. The symmetry of the peaks obtained is excellent for the type of solute.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 24
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Kováts' coefficients ; Stationary phase polarity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A correlation between the retention polarity and the Kováts' coefficient has been found for a number of commercial stationary phases used in gas chromatography. The correlation has been used to predict the polarity of a few mixed stationary phase columns prepared as binary mixtures of OV-101 with OV-25, DC-550 or Carbowax 20M, and also mixtures of OV-225 with SP-2340. A linear relationship was found between polarity and mixture composition. The temperature dependence of the Kováts' coefficient was investigated and found to increase linearly with temperature, the rate of increase depending on the polarity of the stationary phase, with greater increases for more polar stationary phases.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 25
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Gas chromatography ; Polycyclic aromatic hydrocarbons ; Soot and air samples ; Liquid CO2 extraction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The results of the analysis of polycyclic aromatic hydrocarbons (PAH) in soot and similar types of sample are often dependent on the extraction method applied, owing to carbonaceous substances present in these samples. The recoveries of three extraction methods, and ultrasonic ether, a Soxhlet toluene and a Soxhlet extraction with liquid CO2 were compared for a typical soot sample. Additionally the CO2 extraction was optimized with respect to the necessary number of transfers during the extraction and the proper method to remove the CO2 after extraction. Finally, the liquid chromatographic pretreatment of the extract, prior to gas chromatographic analyses of the PAH, was improved.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 31-40 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Resolution of enantiomers ; Thermodynamic analysis ; Enthalpy of interaction ; Extrapolation of net retention time
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The calculation of capacity factors, k′, from net retention times, t′R, and the corresponding dead times, tM, at different temperatures suffers from the limited accuracy of the tM values. If the temperature coefficient racy of the tM values. If the temperature coefficient d ln k′/d (1/T) only is required, it is sufficient to determine net retention times (t′R)p at constant inlet pressure pi for different temperatures, since the temperature dependence of (tM)p can be assumed as (tM)p=A·eB/T, with B being approximately independent of the column inlet pressure and of the nature of the carrier gas. The extrapolation and interpolation of (t′R)p may be either performed by linear regression or graphically with a nomogram for ln (t′R)p versus 1/T. The resolution factor, α, of two components, e.g. enantiomers which are resolved on a chiral stationary phase, can be treated in a similar way. Examples are given for the resolution of enantiomers of two non-proteinogenic amino acids on the new polysiloxane phase L-Chirasil-CPG.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 27
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Reversed-phase HPLC ; Antioxidant-tail reducer ; 4-Hydroxy-3,5-di-tert-butylbenzyl alcohol ; Adsorption on diatomaceous supports
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary As an extension of previous work on the deactivation of diatomaceous supports by hydroxy compounds, 4-hydroxy-3,5-di-tert-butylbenzyl alcohol (HBBA) has been evaluated as a potential combined antioxidant tail-reducer. In contrast to diglycerol and the lower molecular weight polyoxyethylene glycols, HBBA is found to be an inefficient tail-reducer. The adsorption of HBBA from solution onto the surface of Phasesep P has been studied and possible explanations for the apparent lack of surface deactivation are offered. A reversed-phase high-performance liquid chromatographic assay for HBBA has been developed and used to monitor the adsorption of HBBA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 32 (1991), S. 248-258 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Electron capture detector ; Hypercoulometry ; Secondary polarisation effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper reports measurements of the current characteristics and of the signal corresponding to a constant concentration of Freon F-11 for an electron-capture detector, supplied with a pulse voltage with a changeable pulse duration, amplitude and repetition time. It was found that an additional voltage applied to the detector cathode increased the detector signal by about 50% and that the maximal signal was observed at 5 V. The influence of the polarized voltage on the electron caputure efficiency coefficient (p) measured with two detectors in series was demonstrated and the reliability of the sample mass calculation by means of (p) is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 29
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Thin-layer chromatography ; Thermal analysis ; Copper(II) complexes ; Schiff's bases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A study is presented of the thermoanalytical and gas chromatographic (GC) properties of the copper(II) complexes of twenty four tetradenate Schiff's bases. Variations in thermal stability, volatility and GC retention of the complexes are discussed in terms of stereo-electronic effects of the substituents. Although some complexes decomposed extensively during vaporization above 250°C all, apparently, survive chromatography intact at 200°C. Certain complexes were separated as distinct regio-isomers by GC. Fluorinated ligands still appear to be the most suitable derivatizing reagents for Cu(II).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 95-97 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Deans sampling and backflushing ; Univap ; Natural gas odorants ; FPD
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The functions of gas sample injection and column backflushing have been combined in a chromatographic system incorporating switching valves only of the three port solenoid type, installed away from injected sample contact. The system pressures are dynamically adjusted during analytic cycles by a simple dome-loaded regulator network. A sulfur analysis (natural gas odorant) application is demonstrated which also includes a foreflush-to-vent sidestream. The coefficient of variation found for the target analytes was less than 0.8%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 123-128 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Amino acids ; Chiral separations ; Fruit juice adulteration ; Microorganisms
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The configurations of free amino acids (AAs) in orange juice beverages (commercial products of satisfactory and unsatisfactory quality), an orange juice concentrate (bulk product suspected of being adulterated), and in an orange juice that has been contaminated by addition ofLactobacillus plantarum as a model for microbial spoilage, were determined, after derivatization, by means of gas-liquid chromatography (GC) using fused-silica capillary columns coated with Chirasil-L-Val or Chirasil-D-Val as stationary phases. AAs were isolated from juices by treatment with Dowex WX8 ion-exchanger and were investigated, by GC, as theirN(O)-pentafluoropropionylorN(O)-trifluoroacetyl 1-propyl esters. It was found that the high quality orange juice beverage contained L-AAs exclusively whereas this juice, after fermentation withLactobacillus, contained free D-Ala (32.7%), D-Val (62.3%), D-Phe (20.0%), D-Glu (24.3%), D-Ser (2.6%), D-Asp (0.8%), and significant amounts of D-Pro [% D=100 D/(D+L)]. D-Ala (8.8%) and D-Ser (4.2%) were found in a sensory and analytically unsatisfactory orange juice beverage, whilst D-Ala (27.5%) and D-Ser (14.3%) were detected in the orange juice concentrate suspected of being adulterated. Although capillary GC on chiral stationary phases is regarded as being highly suitable for the determination of AA enantiomers in fruit juice beverages, detection of D-AAs is currently not considered as conclusive proof of fruit juice adulteration caused by addition of AA racemates since a non-microbial origin of D-AAs in the respective juice, or an original occurrence of D-AAs, in either the free, substituted, or peptide-bonded form in the fruits, cannot be excluded with certainty.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 258-262 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Packed columns ; Methyl polysiloxanes immobilization ; Peroxide initiated cross-linking
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The free radical cross-linking procedure of stationary phase immobilization introduced by Grob et al. for capillary columns has been adapted for the preparation of column packings on diatomaceous supports. Immobilization of SE-30 and OV-1 on typical gas chromatography supports: Polsorb B-AW, Chromosorb W-AW, Chromosorb G-AW and Gas Chrom Q was investigated. Before immobilization, the supports (excluding Gas Chrom Q) were purified by extraction with 6 M HCl in a Soxhlet extractor and silanized with hexamethyldisilazane vapour at 300°C. The influence of the type and concentration of peroxide on the efficiency of immobilization of the silicone was studied. In order to obtain over 95% immobilization a minimum of 2% w/w of the peroxide in the stationary liquid is required. Properties of packings with immobilized phase were compared with those of related conventional packings. Adsorption activity, column efficiency and thermal stability were used for this comparison.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 33
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention indices ; Target factor analysis ; Reproduction, prediction, classification
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Using the method of target factor analysis (TFA) described by Malinowski and Howery a computer program has been developed to study different sets of gas chromatographic retention data. Physico-chemical, topological and uniqueness parameters have been found to be basic factors to describe solute behaviour problems. Factor analytical solutions have been used to reproduce the data matrices and to make predictions based on best sets of basic factors. The mean absolute error in the reproduction step is between 1.72 retention index units (i.u.) for a relatively simple matrix consisting of retention indices of alcohols and 7.36 i.u. for a combined data matrix of alcohol, aldehyde and ketone retention indices. TFA has also been used to classify solutes based on their retention behaviour. Alkanes have been classified from cycloalkanes, alkanes from alkenes, and alcohols from aldehydes and ketones using only their retention data and a special kind of uniqueness vector.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 34
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Non-equilibrium headspace sampling ; Vegetables and food products ; Flavour compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Static headspace sampling combined with gas chromatography using open-tubular (capillary) columns for the characterization of the flavour of raw vegetables and some vegetable products is described. In order to avoid alteration of the composition of the volatiles, the sample was thermostated for a short time only. Although equilibrium between vapour and sample was not established the reproducibility of such conditions is demonstrated. Typical chromatograms are given; the most characteristic compounds present were identified by mass spectrometry.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 18-24 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Dual-column analysis ; Pesticide analysis ; Organochlorine pesticides ; Temperature optimization ; Flow optimization ; Resolution mapping ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An approach is described for optimizing chromatographic conditions for dual-column analysis of U.S. EPA Method 608 pesticides. Sample throughput for environmental analysis of pesticides can be increased by performing the screening and confirmation analyses at the same time. This requires simultaneous injection, separation, and detection in a GC with dual inlets, columns, and detectors. Resolution maps for flow rate and temperature relationships of poorly resolved peak pairs for 5%-phenyl methyl silicone and 7%-cyanopropyl 7%-phenyl methyl silicone capillary columns are presented. Resolution of target pesticides on the 5%-phenyl methyl silicone column was much more sensitive to changes in flow and temperature-ramp rates than was the 7%-cyanopropyl 7%-phenyl methyl silicone column. Optimal conditions resulted in a run time of approximately 20 min.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 357-360 
    ISSN: 0935-6304
    Keywords: Static headspace analysis ; Gas chromatography ; Isobaric headspace extraction ; MHE method ; Distribution coefficient ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 123-125 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Column technology ; LC-like packed capillary columns ; Hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary columns of 0.3-0.35 mm internal diameter and 0.3-7.7 m length, packed with 3 to 30 μm octadecylsilica stationary phases as used for liquid chromatography, were applied to gas chromatographic separation of low boiling hydrocarbons. Van Deemter plots for these columns showed the optimum column efficiency to occur at linear velocities of 4-5 cm/s. A short column was applied to the rapid separation of components of a natural gas and impurities in standard gases, while a long column was applied to the separation of complex mixtures.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 225-229 
    ISSN: 0935-6304
    Keywords: FTIR spectrometry ; Gas chromatography ; Supercritical fluid chromatography ; Liquid chromatography ; Trace Identification ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The results described in this paper demonstrate that Identifiable FTIR spectra of components separated by gas, supercritical fluid, and liquid chromatography can be measured in real time using a common approach. The sensitivity of each Interface is comparable with that obtained by interfacing the corresponding technique with a bench-top mass spectrometer. The combination of these two spectroscopic techniques should lead to an even more powerful means of Identification of volatile, semi-volatile, and non-volatile components of mixtures.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 39
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Solid phase extraction ; Structure-type separation ; Polycyclic aromatic hydrocarbons (PAHs) ; Diesel fuel ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A simple and effective solid phase extraction (SPE) method using silica gel micro glass columns has been developed for the separation of diesel fuel into groups of aliphatic, and mono-, di- and polyaromatic hydrocarbons. It is based on a stepwise gradient of dichloromethane in n-pentane. The resulting fractions were analyzed by capillary gas chromatography with a flame ionization detector and coupled gas chromatography-mass spectrometry.Commercially available standards, and retention indices and mass spectra were used for identification of individual aromatic compounds. The principal polycyclic aromatic hydrocarbons (PAHs) in diesel fuel are naphthalene, biphenyl, fluorene, phen-anthrene and their alkylated derivatives. Sulfur-containing PAHs are mainly represented by methyl-substituted dibenzo-thiophenes.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 143-146 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Polymeric liquid crystal stationary phase ; Polysiloxane ; PCDD ; PCDF ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A newly developed side chain liquid crystal polysiloxane has been investigated as a stationary phase for the isomer-specific analysis of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans substituted at positions 2, 3, 7, and 8. The retention times from the chromatograms of a standard solution containing all PCDD and PCDF isomers were compared with those from solutions containing only those tetra- to octa-chlorinated compounds substituted at positions 2, 3, 7, and 8. In general, PCDDs substituted at positions 2, 3, 7, and 8 eluted later than most other isomers of the same congener group. The separations obtained on this stationary phase were compared with those obtained elsewhere using a commercially available product.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 41
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Retention index standards ; McReynolds constants ; Stationary phase selectivity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 383-387 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns in series ; Volatile organic compounds ; Ambient air ; Alveolar air ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Analysis of volatile organic compounds in air samples requires high resolution capillary gas chromatography. When the sample contains both polar and non-polar compounds, use of only one type of stationary phase can be unsuitable if it leads to the preferential separation of one kind of component having the same polarity at the expense of the separation of other classes of component.This paper describes the coupling of fused silica capillary columns of different polarity and length in order to achieve the separation of such complex mixtures. The combination is evaluated with a 42 component standard mixture and then applied to various atmospheric air samples and alveolar air of exposed subjects to demonstrate the capabilities of the complete sampling and separation technique.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 587-589 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Headspace analysis ; Mass spectrometry ; Organic solvents ; Printing ink ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Static headspace analysis by gas chromatography has been found to be a suitable method for the analysis of organic solvents in printing inks. Experimental conditions for the analysis have been optimized, and the accuracy and relative standard deviation of the method has been determined. The solvent content of 29 printing inks has been measured.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 621-625 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Dynamic headspace analysis ; Thermodesorption ; Flavor analysis ; Cheese ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The performance of two commercially available systems employing dynamic headspace techniques for collection, enrichment, and injection of volatile compounds has been compared by GC analysis of test mixtures and dairy products. For technical reasons, it has not been possible to crate identical sorbent materials for both kinds of trap were not available, the most similar adsorbent available were chosen. The total quantity of volatile compounds from a test mixture at the column head was calculated using a theoretical model which enables comparable working conditions to be obtained. Under these circumstances special attention was paid to the repeatability of the data obtained from a test mixture in order to ensure reliable results in quantitative analysis. Significant differences in repeatability between the two systems seemed to originate from their distinctly different technical designs.A qualitative comparison of the systems has been performed using a sample of Swiss cheese. On the basis of the results obtained the systems have been dedicated to different applications in the laboratory of the FAM.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 45
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Comparative study ; Liquid crystalline stationary phases ; Polyester stationary phases ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two new categories of stationary phase have been studied: liquid crystals and polyesters. The liquid crystals were p,p′-azoxyphenetol, p(n-hexyloxy)phenyl-p′-methoxy benzoate, and p-pentyloxy-p′-ethoxyazoxybenzene; and the polyester phases 1,4-butanediol succinate (LAC-860), ethylene glycol succinate (LAC-886), diethylene glycol succinate (LAC-738), diethylene glycol adipate (LAC-296), and neopentyl glycol adipate (LAC-769).Abnormal chromatographic behavior, has been observed: an increase in specific retention volumes and an improvement in the separation of normal, branched, and cycloparaffins, depending on their structures, at high temperatures within a specified range. This phenomenon is the opposite of the behavior of traditional stationary phases. From the chromatograms obtained, plots of log vg0 against 1/T, and differential thermal analysis it is concluded that this abnormal behavior may be attributed to the penetration of solutes through the ordered structure of the mesophase and the rod-like molecules of the polyesters. Furthermore, the chromatographic behavior of some of the polyester (LAC-series) stationary phases in respect of temperature changes is similar to that of the nematic mesophases.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 579-583 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary column ; Cold on-column injection ; Amino acid analysis ; Liver ; Brain ; Rat ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A procedure is described for the quantitative determination of amino acids in hepatic and brain tissue samples from the rat. Because the presence of certain matrix components in the tissue material led to interference with chromatographic analysis they were removed by a prechromatographic “clean-up” step.Quantitative analysis of amino acids, as their N-heptafluorobutyryl iso-butyl ester derivatives, was achieved by high resolution gas chromatography on an apolar fused silica open tubular column. Reproducibility data from the complete procedure are presented; coefficients of variation for arginine and histidine in hepatic tissue varied between 7.1 and 10.1% whereas those for most other amino acids were better than 5%, with a mean recovery of 90%.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Springer
    Psychopharmacology 78 (1982), S. 170-175 
    ISSN: 1432-2072
    Keywords: Acetylcholine ; Choline ; Soman ; Organophosphate ; Anticholinesterase ; Toxicity ; Lethality ; CNS ; Brain areas ; Rats ; Gas chromatography ; Mass spectrometry ; Time course ; Cholinergic function
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The time course of changes in rat brain levels of acetylcholine (ACh) and choline (Ch) was investigated following a single SC injection of soman (0.9 LD50, 120 μg/kg) to understand the relationship between central neurotransmitter alteration and soman toxicity. Of the animals exposed to the dose of soman, 46% died within 24 h, with maximum mortality occurring during the first 40 min following soman administration. In a second group, surviving rats were killed at various times after treatment by a beam of focused microwave radiation to the head, and ACh and Ch levels were determined by gas chromatography-mass spectrometry. Soman produced a maximal ACh elevation in the brain stem at 20 min (34.4%), in cerebellum at 40 min (51.9%), in cortex and striatum at 2 h (320.3% and 35.2%, respectively), and in hippocampus and midbrain at 3 h (94.5% and 56.8%, respectively). ACh levels remained above normal approximately 30 min in the brain stem; 2 h in the midbrain, cerebellum, and striatum; 8 h in the cortex; and 16 h in the hippocampus. Ch levels were elevated in all areas except the striatum. Ch maxima occurred at 10–40 min and returned to control levels approximately 3 h after injection. Results suggest that perturbation of ACh levels due to soman was not uniform throughout the brain and that soman toxicity may reflect ACh changes in multiple areas, rather than changes in any given area. These data further suggest a possible relationship between elevated Ch levels and soman toxicity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Springer
    Research in experimental medicine 181 (1982), S. 19-25 
    ISSN: 1433-8580
    Keywords: Gas chromatography ; Serum level ; Azathioprine ; 6-Mercaptopurine ; Immunosuppression
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The knowledge of serum levels of azathioprine or its metabolite 6-mercaptopurine is important for the monitoring of the immunosuppressive therapy after kidney transplantation, especially when kidney function is low. For this reason, the work of Bailey et al. was modified. 6-Mercaptopurine was extracted from the serum with a mixture of isopropanol-ethylacetate (1:1 v:v), derivatized with trimethylaniliniumhydroxyde and measured gaschromatographically. Sulfhydryl-protecting reagents were added to prevent loss of substance. Oxyethyltheophylline was used as the internal standard. The extraction and clean-up method recovered 80% of the 6-mercaptopurine present, the lower limit of sensitivity was 20 ng/ml, i.e., ten times lower than that of Bailey et al. The method could be realized on eight patients treated with azathioprine, the half life of the drug was about 20–40 min within the first hour after i.v. application.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Springer
    Naunyn-Schmiedeberg's archives of pharmacology 321 (1982), S. 293-297 
    ISSN: 1432-1912
    Keywords: Alcoholism ; Cerebrospinal fluid ; Ethanol ingestion ; Gas chromatography ; Mass spectrometry ; 5-Hydroxytryptophol ; Urine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The serotonin metabolite 5-hydroxytryptophol was determined in cerebrospinal fluid and urine of alcoholics and healthy subjects, by a glass capillary gas chromatographic-mass spectrometric method. The urinary excretion rate (14.6±2.9 pmoles/μmoles creatinine) and urine (109±20 pmoles/ml) and cerebrospinal fluid (4.12±0.21 pmoles/ml) concentrations in healthy subjects were established. Only 1% of the 5-hydroxytryptophol in urine occurred in free form. Ethanol ingestion (80, 120 g) by healthy subjects lead to a 20–100-fold increase in the urinary excretion rate of 5-hydroxytryptophol. In cerebrospinal fluid the increase was about 60%. Alcoholics had increased urinary excretion rates and cerebrospinal fluid levels during intoxication, which were in the same range as in intoxicated healthy subjects. During recovery from intoxication, the 5-hydroxytryptophol level in alcoholics decreased, but the CSF levels were still higher than in healthy subjects.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 50
    ISSN: 1612-1112
    Keywords: Teflon capillary columns ; Chemically modified teflon ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The preparation of teflon capillary columns employing direct coating of the stationary phase to the chemically modified teflon surface and the role of the chemically modified teflon in the separation mechanism are described. Two types of contributions from the modified teflon have been observed: nonspecific adsorption of the carbon surface and specific interactions of polar groups in the carbon skeleton. The use of polar liquid phases can eliminate adsorption due to the presence of polar groups in the modified teflon.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 60-62 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Amines ; Derivatization ; Chloroformate esters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The gas chromatographic analysis of amines after conversion to electron capture sensitive carbamates in two-phase systems has been studied. Hydrophilic compounds, for instance methylamine, are reacted with 2,2,2-trichloro-tert. butyl chloroformate. Quantitation below 10−7 M can be made by thermionic or electron capture detection. A hydrophobic amine, namely N,N-dimethyl-n-octylamine, was derivatized with 2,4,6-tribromophenyl chloroformate with addition of iodide ion to the aqueous phase. The favorable effect of iodide ion as well as the choice of pH and chloroformate ester is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 98-102 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Rectangular channel ; Efficiency ; Capacity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas chromatographic experiments have been performed in a truly rectangular channel with a 60∶1 cross-sectional aspect ratio, constructed according to the field-flow fractionation technology. It is shown that the peak broadening is controlled by the thickness of the channel while the maximum load is determined by the largest cross-sectional dimension. However, even with its elongated configuration, the side walls contribute significantly to the band broadening of solutes with a high diffusivity. Good agreement is found between the experimental plate height data and the recent theoretical calculations of Golay [13] taking into account the side-wall effect.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 704-706 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Isopropyliden-sorboses ; TMS-derivatives ; GC-MS combined technique ; Mass spectra
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method has been developed using gas chromatography — electron impact mass spectrometry for the determination of the di-0-isopropylidene-sorbofuranose and mono-0-isopropylidene-sorbofuranose. The compounds are separated as their trimethylsilyl derivatives on a capillary column coated with the stationary phase SE-52. The mass spectra show that the silylation reaction is quantitiative and that the isopropylidene groups does not change.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 183-185 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Analysis of ethylbenzene hydroperoxide ; Time normalization method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A gas chromatographic method, based on the time normalization technique, is described for the analysis of ethylbenzene hydroperoxide in mixtures containing ethylbenzene, acetophenone, 1-phenylethanol, benzaldehyde and phenol. Different liquid phases were tested and the best results were obtained with tricresyl phosphate and neopentyl glycol sebacate. The influence of the support, the liquid loading and the gas velocity are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 625-630 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular (capillary) columns ; Comparison of liquid phases ; Influence of temperature ; Retention index data
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The influence of temperature and liquid phase film thickness of open-tubular (capillary) columns on the retention index values of hydrocarbons on methylsilicone liquid phases is discussed. Data obtained on methylsilicones and squalane are compared. Retention index values of 43 hydrocarbons between 40 and 70 °C on OV-101 liquid phase are listed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 351-354 
    ISSN: 1612-1112
    Keywords: Supported catalysts ; Reserved-flow GC ; Drying step ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Application of reversed-flow gas chromatography to study the drying step in the preparation of supported catalysts is proposed. It is demonstrated that this technique can be applied to investigate the kinetic law followed, as well as to obtain kinetic parameters of drying (rate constants, activation energies and frequency factors). Amaterial illustrating this application is γ-Al2O3 impregnated with usual organic solvents (n-C5H12,n-C6H14,n-C7H16, CH3COCH3 and CH3CH2OH). It was found that in all cases above a simple first-order law based onone kind of active site is followed. Moreover, it was observed that the activation energyE a of the drying process increases almost linearly with the relative molecular mass of the solvent, whereas for the same solventE a increases with the amount used. The operation of a kinetic compensation effect suggests “similar” activated complexes of the various solvents used.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 57
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Fused silica capillaries ; New polar phases: OV-1701 and RSL-310 ; Immobilization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The possibilities of OV-1701 and RSL-310, two new stationary phases, have been evaluated for capillary gas chromatography in fused silica columns. OV-1701 is a cyanopropylphenyldimethyl polysiloxane of moderate polarity possessing excellent chromatographic characteristics. The phase exhibits high coating and chromatographic efficiencies, high temperature stability and is suitable for cross-linking. RSL-310 is a polar liquid stationary phase yet to be permanently bonded in a capillary column. The selectivity of both phases extends the applicability of fused silica columns.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 241-244 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Monosaccharides ; Polyols ; GC of TMS derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper describes the gas chromatographic separation of the mixture of isopropylidene monosaccharides, and their trimethylsilyl derivatives. Based on the total analysis time and resolution the best stationary phase was SF-96 using Chromosorb G as the solid support and temperature programming.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 312-314 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Injection-port modification ; Oxygen and nitrogen traces
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The paper presents a new device modifying normal injection port of a gas chromatograph for eliminating air contamination thus enabling determination of traces of oxygen or nitrogen. Further modification is also proposed which enables the analysis to be carried out with a limited quantity of sample gas. Potential application of this device in the analysis of reactive gases like florine has been indicated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 60
    ISSN: 1612-1112
    Keywords: Phthalides ; Gas chromatography ; Chromosorb W ; Isomerization ; Ligustilide
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary During GLC of naturally occurring mixtures of phthalides on packed columns an artefact was sometimes detected that originated from Z-ligustilide. Active sites of Chromosorb W were responsible for the formation of the artefact, that was assumed to be E-ligustilide as GC-MS revealed that its mass spectrum was identical with that of Z-ligustilide. No isomerization was observed when freshly coated Chromosorb W was used or the support was deactivated by benzoyl chloride or melamine. The identity of the artefact was confirmed by UV irradiation experiments.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 30-32 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Arsenic ; Inorganic materials
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the quantitative chlorination and extraction of arsenic as arsenic trichloride from a number of alloys. The conditions for the quantitative gas chromatographic measurement of the volatile chloride have been studied. The proposed method for inorganic materials is very fast giving results within 10 min; sensitive, 1.5·10−13 g As can be detected, simple and accurate. At the ng level of As the error is about 20% with a standard deviation less than 20%, and at the 10pg level the error is about 36% with a standard deviation of 44%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 765-768 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Preparative scale chromatography ; Capacity ; Dual-stage separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The capacity of different versions of single- and dual-stage separation of mixtures on a preparative scale is considered. It has been shown that dual-stage separation with intermediate condensation considerably enhances the capacity of the installation as compared with a single-stage process.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 117-124 
    ISSN: 1612-1112
    Keywords: Various packed GC column ; Gas chromatography ; Porous layer beads ; GC/MS analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Theoretical comparisons of various packed GC column types are presented with respect to analysis time, efficiency, sample dilution, and sample capacity for a given maximum inlet pressure. In particular, totally porous particles, porous layer beads, and glass beads are compared with one another. It is shown that 30 μm porous layer beads offer a useful compromise between analysis time and plate count with relatively good sample capacity. Moreover, when using 1 mm i.d. columns (microbore), outlet flow rates that are reasonable for direct coupling to magnetic sector mass spectrometers are achieved making these columns suitable for GC/MS. Using 30 μm Zipax porous layer beads, columns yielding 8,000 to 10,000 plates/meter have been produced with inlet pressures of 13 to 26 atm. A simple modification of the injection port converts the maximum inlet pressure of a commercial gas chromatograph to 26 atm. With such pressures, columns in excess of 20,000 plates can be achieved. Chromatograms are presented illustrating the promise of these microbore columns for GC and GC/MS analysis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 245-248 
    ISSN: 1612-1112
    Keywords: Chromatoscopy ; Gas chromatography ; Graphitized carbon black ; Molecular structure and retention ; Aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A molecular-statistical calculation of the retention volumes at zero sample size on graphitized thermal carbon black is carried out for quasi-rigid molecules of fluorene, indene, 1-methylindene, 2-methylindene and three dimethylindenes. A reasonable agreement is observed between the calculated and the available experimental gas chromatographic data. The potential barrier to internal rotation and the torsional angle in styrene molecules are estimated by comparing theoretically calculated and measured retention volumes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 65
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Silicone liquid phases ; Oxidation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The on-column oxidation of apolar and polar silicones used as gas chromatographic stationary phases is investigated. Even at 225° the effects of oxidation are found to be slight. Of the materials investigated the methylphenylsilicones are the most stable.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 66
    ISSN: 1612-1112
    Keywords: Glass capillary ; Gas chromatography ; Methyl chloroacetates ; Methyl chloropropanoates ; Methyl chlorobutanoates
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The gas chromatography of all chlorinated methyl acetates, methyl propanoates and methyl mono- and dichlorobutanoates has been studied on Carbowax 20M and SE-30 glass capillary columns under various running conditions. The order of elution on a non-polar column was largely determined by the boiling point of esters, whereas on a polar column it was much influenced by the structure of compounds. Complete separation of the combined mixture of all 27 compounds could not be achieved, however, methyl 3,3-dichlorobutanoate was the only ester overlapped on both columns in spite of the various column temperatures used. The best separation of the mixture was on Carbowax 20M with a temperature program from 50°C at 8°C/min, isothermal running conditions leading either to poor separation of volatile components or long analysis time and broad peaks of higher chlorinated esters. The relative retention times for compounds at the various column temperatures are given and the retention order on a polar and on a non-polar column discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 517-520 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Carbon-silica adsorbents ; n-Octadecanol film ; Phase transitions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The properties of the n-octadecanol film on carbon-silica adsorbent (Carbosil) were investigated. It was found that n-octadecanol forms an oriented film on the Carbosil's surface. If the surface of the basic silica gel is not completely covered with carbon, then the phase transition takes place in this film at a temperature higher than the melting temperature of n-octadecanol. One may distinguish two forms of this film, characterised by the different structures and the temperatures of the phase transitions. The first exists on the surface of silica gel unblocked by carbon. This part of the film is a monolayer, in which the alcohol molecules are vertically oriented. The solid compact-liquid expanded type phase transition at the well-defined temperature occurs in this film. In the second part of the film formed on the carbon surface, there is a multilayer of n-octadecanol. Its molecules are probably parallely oriented in relationship to the adsorbent surface. This film desintegrates progressively when the temperature increase. Maximum temperature of this phase transition is lower than the temperature of its analogue on pure silica gel surface.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 546-558 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Capillary columns ; Quantitative analysis ; Sample inlet systems ; High-speed analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The attainment of precise quatitative analytical data using open-tubular (capillary) columns in standard, commercially available gas chromatographic instrumentation is demonstrated. Key elements in the design and proper utilization of the instrumentation are discussed. The function of the various sample introduction systems is elaborated and their quantitative performance demonstrated. The extra-column contribution to band-spreading is determined and the resultant data is used assessing the suitability of commercial instrumentation for highspeed capillary gas chromatography. The quantitative analysis of a sample containing some eleven components in less than thirty seconds is shown.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 69
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Crystal hydrates as stationary phases ; Mobile Phases containing water ; Selective retentions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of crystallohydrates, crystallohydrate solutions and melts as stationary phases in gas chromatography has been proposed. Crystallohydrates have been shown to display high selectivity in the separation of polar organic compounds when use is made of water vapours as the mobile phase. Some aspects of gas-liquid chromatography in water vapours and with the stationary phase comprising crystallohydrates have been studied, and the preliminary results obtained point to the desirability of further progress in this field.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 201-203 
    ISSN: 1612-1112
    Keywords: Phenols ; Whisky ; Gas chromatography ; Aroma compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Twelve volatile phenols were identified in whisky by combined gas chromatography-mass spectrometry. Of these phenols 2,4-dimethylphenol was found for the first time in the aroma of whisky. The content of phenol, o-, m-, and p-cresol, guaiacol, p-ethylphenol, p-ethylguaiacol and eugenol in whiskies originating from different countries was determined by gas chromatography as their 2,4-dinitrophenyl ethers using electron capture detection. The results show that Scotch whiskies differ from others in the content of o-, m-, and p-cresol. The odour threshold values of phenols studied were determined in a 10% (v/v) ethanol-water mixture and in some cases also in the whiskies. Cresols have been found to make contribution to the aroma of Scotch whisky.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 26-31 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Ionization detectors ; Gaia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper is an account of the development of the gaia hypothesis as seen through the eyes of a gas chromatographer. Gaia is a radical notion about the Earth which postulates the climate and chemical composition to be regulated at an optimum by and for life. Gas chromatography played an important role in the gathering of evidence for the hypothesis but most significantly the art of inventing detectors lead to the developement of a planetary life detector through which gaia was revealed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 282-285 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Naphtha analysis ; Gasoline analysis ; Hydrocarbon type analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two different gas chromatographic methods are used for the determination of hydrocarbon type distribution in naphtha and gasoline samples with final boiling points up to 275 °C. The methods are based either on a single capillary column or on a valve-switched packed column system. Both methods give extensive information on paraffins, olefins, naphthenes and aromatics in total as well as by carbon-number. In each case the analysis is fully automated with a computer controlling the entire analysis from injection to results presentation. The advantages and limitations of both methods are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 322-324 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Graphitized carbon black supports ; Determination of hydroxyacids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Acid-washed graphitized carbon black (Carbopakc B) modified with trimesic adic and PEG 20M has proved to be effective for quantitative analysis of underivatized low molecular weight hydroxyacids. Calibration data revealed good linear relationships between relative peak area and concentration for lactic and 3-hydroxybutyric acids down to 0.05 mmol/l. The packing material was suitable for the analysis of aqueous solutions of hydroxyacids as it is tolerant to injections of water over a prolonged period of use. The GC system developed has been applied to the analysis of some hydroxyacids of biomedical interest in blood plasma and lactic acid contained in wine and beer.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 74
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Modified thermal energy analyzer ; Selective detection of nitrogen compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A modification to the TEATM Analyzer is described, which allows it to be used as a highly selective GC detector for nitrogen compounds as well as for N-nitrosamines and nitro compounds. The modified Analyzer is as sensitive as the AFID, but has a much higher selectivity towards nitrogen compounds than the AFID. Its response appears to be molar, with an output that is dependent only on the number of nitrogen atoms present. The performance of the modified Analyzer for the analysis of ammonia, amines,N-nitrosamines, nitriles and organonitro compounds is reported and discussed, as is its application to the detection of these compounds in bacon and beer samples.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 75
    ISSN: 1612-1112
    Keywords: Graphizized carbon black traps ; Organic air pollutants ; Work areas ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of traps containing graphitized carbon black for the collection and pre-analysis of atmospheric pollutants in industrial areas is presented. The working conditions, in terms of trapping capability and effectiveness of release by thermal desorption are discussed. Some practical applications are also given.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 76
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Van der Waals' volume ; Polarity of stationary phase ; Retention index
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Equations for Retention Index (I) versus Van der Waals, volume (Vw) on squalane are studied for alcohols, carbonyls, esters and ethers. Each equation includes linear and branching substances with different positions of the functional group in the carbon chain. The study is extended to stationary phases with polarities from 4.29 to 91.54 on the Tarjan et al. scale. Variations of the slope and origin ordinate values with the polarity of the stationary phase are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 125-132 
    ISSN: 1612-1112
    Keywords: Capillary columns ; Fast analysis ; Gas chromatography ; Instrumental effects ; Optimization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The efficiency of fast GC columns depends largely on the quality of the chromatograph. A theoretical and experimental study shows the relative importance of the various phenomena involved and permits the optimization of a GC System. Extremely good performances, exceeding 2,500 plates per second have been routinely obtained.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 180-182 
    ISSN: 1612-1112
    Keywords: Acidic fermentation products ; Characterisation ; Gas chromatography ; Methyl esters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A rapid and simple method for the identification of acidic fermentation products is described. Methyl esters of volatile and non-volatile acids are separated on a single chromatographic column. Retention time data for a number of acids are tabulated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 521-524 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index ; Connectivity index ; Van der Waals' volume ; Alkanes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The relationships between retention index and Van der Waals' volume and between retention index and connectivity index have been studied for 58 different alkanes (C1−C9) on squalane. The correlation coefficient for the former is higher than for the latter. From these equations a linear relationship between Van der Waals' volume and connectivity index is obtained which indicates that the two parameters are equivalent. A simple method for calculating the Van der Waals' volume of alkanes is proposed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 80
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Capillary columns ; Fused silica capillaries ; Capillary drawing ; Glass capillaries
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A compact description is given of a simple and reliable method of drawing flexible fused silica capillary for gas chromatography. Some emphasis is given to the fact that the practices of drawing optical fibres should not be followed too slavishly so this leads to unnecessarily complicated and expensive equipment. Satisfactory capillary column silica tubing can be made with straightfoward extension of the method developed earlier for drawing thick walled capillary. A simple glass/silica hydrogen oxygen diffusion flame bumer is described for fusing the preform tubing at the draw point which is enclosed by a water cooled glass enclosure to trap evaporated silica and maintain the operation under dust free conditions. The uniformity of the capillary diameter is better than 5% which is adequate for most gas chromatographic purposes. The second part of the paper yet to be published will cover the methods developed for coating the capillary both internally and externally.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 107-111 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Thermionic ionization ; Catalytic flame ionization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A newly designed thermionic detector was operated in two modes of thermionic ionization detection (TID), and a third mode of catalytic flame ionization detection (CFID). Operating modes were varied by changing the composition of the electrically-heated thermionic/catalytic source, and the composition of gases supplied to the detector. A TID-2 source activated by a low concentration of Cs/ceramic was operated in a dilute H2/air environment and provided specific responses to nitrogen and phosphorus compounds. A TID-1 source activated by a high concentration of Cs/ceramic was operated in a N2 environment and provided very high specificities and picogram detectivities to compounds containing electronegative functional groups such as the NO2 group. A CFID source formed from Ni/ceramic was operated in a H2/air flame environment and provided universal responses to all organics with enhanced responses to some heteroatom compounds.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 82
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 382-384 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Trapping by active charcoal ; Thermal desorption system ; Microwave oven ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 50-51 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass, fused silica ; Connection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 84
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Effluent splitter ; Selective detectors: NPD, Hall™ electrolytic conductivity detector ; Chloro- and chloronitroanilines ; POTW sludge extracts ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Simultaneous detection with a 700-A Hall™ and an NPD detector is an effective technique for characterizing chloro-and chloronitroanilines in highly complex Publicly Owned Water Treatment Works (POTW) sludges. The utilization of a modified Varian effluent splitter and a SE-54 fused silica capillary column permitted the detection of mid-picogram quantities of the polar chloroanilines without sacrificing peak shape. The response of the Hall™ detector in the halogen mode was roughly proportional to the number of chlorine atoms present, while the response of the Hall™ in the nitrogen mode and the NPD was less predictably influenced by the presence of one or more nitro groups. When combined with retention time data, the ratio of the NPD response to the Hall™ response has been found to substantiate the presence of chloro- and chloronitroanilines in sludge extracts.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 98-99 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Polyaromatic hydrocarbons ; Airborn Particulates ; Aircraft turbines ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 86
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; High temperature silylation ; C2-C6 fatty acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 206-207 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; cis, trans, positional isomers of C22 esters separated on OV-73 ; Numerous arguments favor nonpolar columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 236-244 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Rotary valve ; Cold trap ; Reinjection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper describes a cold trap/reinjection system for capillary columns which utilizes a flow switching rotary valve. Sample enrichment is performed in a liquid nitrogen-cooled glass trap attached to the valve. Evaporation of enriched compounds is carried out with the aid of an electric heating coil. Parameters such as cryogenic trapping efficiency, reinjection rates, transference of sample, and adsorption, as well as overall performance, are examined. In addition, a comparison is made between the cold trap/reinjection technique and injection with a gas-tight syringe.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 265-266 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Helium ionization detector ; Aroma ; Coffee ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 45-47 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Fast screening of drugs and adulterants ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 55-56 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Non-uniformity of distribution of stationary phase confirmed ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 53-55 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Thermal aging regeneration of fused silica capillaries ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 93
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary ; SD-E enrichment ; Pesticide residues ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A simple method is described for the quantitative determination of organochlorine pesticides and polychlorinated biphenyls (PCB's) in water at the sub-ppb level. A micro gas-phase extractor advantageously replaces other preconcentration and purification techniques. The extract is analyzed by capillary gas chromatography without further enrichment. The recovery at the ppb level was nearly 100% for organochlorine pesticides and more than 80% for PCB's. The complete procedure including sample preparation, steam distillation-extraction, and capillary gas chromatographic analysis is carried out in less than four hours.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 377-378 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Glass capillary columns ; Headspace analysis ; Alcohols in blood ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 165-166 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Pulse flow reaction chromatography ; Two-detector system ; Reactions in a two-detector system ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 321-321 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Pyrolysis studies ; Cryofocusing device ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 80-84 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Triglycerides in cocoa butter, hazelnut oil ; Separation according to the number of unsaturated fatty acids (N.U.F.A.) ; Ozonolysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Structure determination of triglycerides according to their number of unsaturated fatty acids (N.U.F.A.) is more easily achieved after ozonolysis of their mixtures (fats and oils) than by capillary gas chromatographic analysis of the mixture as such. Analyses performed before and after ozonolysis of cocoa buttel, hazelnut oil, and a mixture of both fats illustrate the potential of this approach to the structure elucidation of triglycerides by chromatographic techniques.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 156-157 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Cold trapping ; Use of ABT concept in evaluating effect of trapping on peak ; shape ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 175-181 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Discrimination factor non-vaporizing on-column/vaporizing splitless injection for underivatized steroids ; Quantitation feasible for most underivatized steroid hormones except corticosteroids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Recent developments in the preparation of capillary columns by persilanization of the glass surfaces have resulted in highly inactive, heat-stable columns. With this type of column certain steroid hormone classes can be analyzed without derivatization; these include the 17-keto steroids, 11-oxo compounds, estrogens, and progesterone metabolites. It has been found that good quantitative analysis calls for non-vaporizing, on-column injection, as normal vaporizing injection results in breakdown of thermolabile compounds such as estriol and 17-OH progesterone metabolites. The gas chromatographic method described was used to obtain urinary steroid profiles.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 208-209 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Liquid chromatography ; Capillary glass ; Capillary columns with inside splitting of eluent ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...