Bibliothek

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Digitale Medien  (51)
  • 1995-1999  (51)
  • 1980-1984
  • 1998  (51)
  • Gas chromatography
  • Computational Chemistry and Molecular Modeling
  • Nuclear reactions
Materialart
  • Digitale Medien  (51)
Erscheinungszeitraum
  • 1995-1999  (51)
  • 1980-1984
Jahr
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Journal of biomedical science 5 (1998), S. 415-420 
    ISSN: 1423-0127
    Schlagwort(e): Isoprostanes ; Oxidative stress ; Lipid peroxidation ; Gas chromatography ; Mass spectrometry ; Human disease
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Medizin
    Notizen: Abstract The development of a specific, reliable and noninvasive method for measuring oxidative stress in humans is essential for establishing the role of free radicals in human diseases. Currently, accurate techniques to assess oxidant injury in vivo are extremely limited although a number of approaches are being investigated. Of these, the measurement of specific products of nonenzymatic lipid peroxidation, the F2-isoprostanes (F2-IsoPs), appears to be a more accurate marker of oxidative stress in vivo in humans than other available methods. The purpose of this brief review is to acquaint the reader with the IsoPs from a biochemical perspective and to provide information regarding the utility of quantifying these compounds as indicators of oxidant stress.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Zeitschrift für Lebensmittel-Untersuchung und -Forschung 206 (1998), S. 48-51 
    ISSN: 1431-4630
    Schlagwort(e): Key words Carbohydrates ; Myo-inositol ; Orange juice quality ; Gas chromatography
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Abstract  A gas chromatographic method using a capillary column is described for the quantitative analysis of fructose, glucose, sucrose and myo-inositol in orange juice. The method is evaluated for precision and recovery using phenyl-β-glucoside as an internal standard. The results support the suitability of the method. Carbohydrates (fructose, glucose, sucrose and myo-inositol) were determined in different kinds of orange juice. The determination of carbohydrate composition and ratios of the carbohydrate constituents provide a method to assess orange juice quality, especially the myo-inositol content and myo-inositol/fructose ratio. These new indices, which were found to be lower in samples made from concentrates, provide information on the quality and genuineness of orange juice.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Zeitschrift für Lebensmittel-Untersuchung und -Forschung 206 (1998), S. 77-82 
    ISSN: 1431-4630
    Schlagwort(e): Key words Anticarcinogen ; CLA ; Conjugated linoleic acid ; Daily intake ; Foods ; Gas chromatography ; Lipids
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Abstract  The quantities of the biologically active isomer of conjugated linoleic acid (CLA) – C18:2 c9t11 – in 139 German foods were analysed by capillary gas chromatography (results are given as a % of all identified fatty acid methyl esters). The CLA content ranged from 0.40% (Gouda) to 1.70% (Jurassic cheese, Old Emmentaler) in dairy products, from 0.11% (rabbit) to 1.20% (lamb) in meat, and from 0.01% (pike-perch) to 0.09% (carp) in fish. CLA could be detected in neither vegetable fats or oils nor in margarines (CLA 〈0.01%). Crisps, chocolates, cakes and pastries, and other foods have only a negligible CLA content. The average estimated CLA intake in Germany was calculated to be 0.35g CLA/day for women and 0.43g CLA/day for men.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    Zeitschrift für Lebensmittel-Untersuchung und -Forschung 206 (1998), S. 213-216 
    ISSN: 1431-4630
    Schlagwort(e): Key words Milk fat ; Mixed fat ; Milk fat content ; Butyric acid ; Gas chromatography
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Abstract  The analysis of butyric acid (C4) is of importance for the determination of the proportion of milk fat in mixed fats. Three gas chromatographic methods were compared with regard to their precision for the measurement of C4, i.e. analysis of butyric acid methyl ester after trans-esterification of fat by sodium methylate (method A) or trimethyl sulphonium hydroxide (method B), as well as analysis of free butyric acid (method C), using an internal standard with each method. The examination of 30 milk fats which varied greatly in terms of their C4 content, using methods A, B and C, resulted in mean values of C4 of 3.42 g/100 g fat, 3.71 g/100 g fat and 3.06 g/100 g fat, respectively. The value determined using method B seemed too high, and this may have been due to the presence of co-eluting artefacts, whereas the value determined using method C was clearly too low, and can probably be attributed to losses during sample preparation. The standard deviation (SD) of 0.015 obtained from repeated analyses using method A was quite good. Results obtained using methods B and C had SDs of 0.029 and 0.074, respectively. Different levels of free fatty acids did not affect the results obtained using method A. When method A was checked by analysis of the reference fat, CRM 164, the C4 level determined was found to deviate from the certified C4 content of 3.49 (± 0.06) g/100 g fat by only 0.05 g C4/fat 100 g. Thus method A proved the most suitable for the determination of the proportion of milk fat in mixed fats by analysis of butyric acid.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Springer
    Zeitschrift für Lebensmittel-Untersuchung und -Forschung 207 (1998), S. 180-181 
    ISSN: 1431-4630
    Schlagwort(e): Key words UHT milk ; Storage ; Monosaccharides ; Gas chromatography
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Abstract  Changes in the free monosaccharide fraction and non-casein nitrogen during the 3-month storage of five batches of commercial UHT milk were studied. Batches with high residual proteolytic activity showed a considerable increase in galactose, N–acetyl glucosamine and N–acetyl galactosamine levels during the storage period, whereas their glucose and myo-inositol contents remained unaltered. In batches with slight or negligible proteolytic activity no changes in the free monosaccharide fraction were observed.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Springer
    Intensive care medicine 24 (1998), S. 415-421 
    ISSN: 1432-1238
    Schlagwort(e): Key words Acetone ; Gas chromatography ; Isoprene ; Lipid peroxidation ; Microwave desorption ; N-pentane
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective: Application of a new method for analysis of exhaled gas in critically ill patients. Design: Open study. Setting: Surgical intensive care unit of an university hospital. Patients: Thirty-seven consecutive, critically ill, mechanically ventilated patients. Interventions: None. Measurements and results: Chemical analysis of the patient's exhaled gas was based upon substance adsorption and concentration onto activated charcoal, microwave desorption and gas chromatographic separation. Patients with acute respiratory distress syndrome (ARDS) exhaled less isoprene than those without ARDS [9.8 (8.2–21.6) vs 21.8 (13.9–41.4) nmol/m2 per min [median (95 % confidence interval)], p = 0.04]. In patients who developed pulmonary infection, pentane elimination increased from 0.4 (0.0–5.4) to 2.7 (0.6–6.1, p = 0.05) nmol/m2 per min and isoprene elimination decreased from 5.2 (0–33) to 5.0 (0–17, p = 0.05) nmol/m2 per min, resulting in a significant increase in pentane/isoprene ratio from 0.1 (0–0.3) to 0.4 (0–15, p = 0.007) when compared to patients without pulmonary infection. Conclusions: The new method allows quantitative analysis of human gas samples with low substance concentrations and is well suited for clinical studies which involve the investigation of metabolic processes in the lung and the body.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Springer
    Space science reviews 84 (1998), S. 199-206 
    ISSN: 1572-9672
    Schlagwort(e): Nuclear reactions ; Nucleosynthesis ; Abundances ; Stars:Evolution ; Interior ; Rotation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract We first recall the observational and theoretical facts that constitute the so-called 3He problem. We then review the chemical anomalies that could be related to the destruction of 3He in red giants stars. We show how a simple consistent mechanism can lead to the destruction of 3He in low mass stars and simultaneously account for the low 12C/13C ratios and low lithium abundances observed in giant stars of different populations. This process should both naturally account for the recent measurements of 3He/H in galactic HII regions and allow for high values of 3He observed in some planetary nebulae. We propose a simple statistical estimation of the fraction of stars that may be affected by this process.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 47 (1998), S. 35-41 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Programmed-temperature vaporization (PTV) ; Large-volume injection ; Direct water injection ; Triazines
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary The potential of large-volume PTV injection was studied for the analysis of triazine herbicides in water samples. Direct water injection and in-vial extraction were described and compared. Detection limits were between 0.01–0.02 μg L−1 and relative standard deviations were 〈9%. Both methods are suitable for the analysis of triazines at ppt-level, although in-vial extraction is favourable for water samples with relatively large amounts of matrix components.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 47 (1998), S. 42-48 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Cholesterol oxides ; Cholesterol oxidation products (COPs) ; Meat products
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary A method of extraction, purification and gas chromatographic analysis of five cholesterol oxidation products (COPs) (7β-hydroxycholesterol, 5α, 6α-epoxycholesterol, 25-hydroxycholesterol, 7-ketocholesterol and cholestane-3β, 5α, 6β-triol) has been developed. The method is aimed at the determination of COPs in meat and meat products, in particular dry sausages, where large differences in the content of cholesterol and its oxidation derivatives may occur. Linearity of response of trimethylsilyl ethers was defined. The minimum concentration tested was 2.5 μg g−1 in the injected solution. The main feature of the present work is the addition of a purification step of unsaponifiables by SPE on silica cartridges. Extraction recoveries of COP standard mixtures, performed with or without the SPE step, are evaluated. The introduction of the clean-up step results in high purity samples without further losses in the entire process.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 47 (1998), S. 57-62 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Solid-phase extraction ; Graphitized carbon black ; Volatile organic compounds ; Workplace air
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary A fast, simple, and reliable method is presented for the determination of atmospheric semi-volatile organic pollutants at μg m−3 levels. The method has been used to monitor potentially carcinogenic toxic compounds to which workers are exposed in workplaces, and to measure the same compounds in outdoor air.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 11
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 47 (1998), S. 63-71 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Liquid foods ; Food packaging materials ; Vinylchloride
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary The interaction of vinylchloride (VC) with liquid foods, such as water, olive oil and honey, was studied using the relatively new technique of Reversed-Flow Gas Chromatography (RFGC). The RFGC method permits the calculation of the VC diffusion coefficient in the liquid phase (water, oil and honey) and the determination of the partition coefficient of VC between the liquid and the carrier gas, as well as the determination of the Henry's constant of VC in the liquid food. From the variation of the above parameters with temperature, thermodynamic parameters (free and excess free energies, enthalpies, entropies and activity coefficients) were calculated for the adsorption of VC by liquid foods. These are discussed in comparison with the same parameters calculated from empirical equations or determined experimentally by other techniques.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 12
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 47 (1998), S. 570-574 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Compressibility correction factor ; Specific retention volume
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary The exact definition of the compressibility correction factor,j, has been extensively discussed in recent literature. In this work, it is shown that this compressibility correction factor has several different interpretations; however, the simplest and most useful meaning involves a correction from the experimentally accessible pressure at the outlet of a column to the average pressure in the column. Also, an unconventional definition of the retention volume of a solute in terms of the sample size and the equilibrium concentration of the solute in the mobile phase is presented. This retention volume definition is presented as an alternative to the common definition ofV R as the volume of carrier gas which passes through the column in a period of time called the retention time. In this discussion, it is emphasized that the temeprature dependence of the specific retention volume is determined by the thermodynamics of the phase distribution process for the solute and not by an equation-of-state for the carrier gas. Finally, the conventional correction of the specific retention volume by a factor of 273/T c can be used to correct a volume of carrier gas to a pseudo-standard state of 273 K and the average pressure in the column; however, this corrected specific retention volume has no relation to the specific retention volume that would be experimentally obtained at this standard state temperature and pressure. compressibility correction factor, and specific retention volume, were examined with regard to the physical interpretation, exact definition and appropriate standard states to be applied to these commonly reported chromatographic parameters. Such arcane discussions are beneficial to the health of science but may lead to confusion among potential and practicing chromatographers. In order to prevent or at least help ameliorate this problem, the following discussion presents a somewhat unorthodox interpretation of the questioned terms along with a pseudo-physical explanation of the so-called retention volume which is ubiquitous throughout the chromatographic literature.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 13
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; SPME ; Soil and groundwater samples ; Chlorobenzenes ; Thermal desorption
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary A complex method was developed for the determination of chlorobenzenes in soil and groundwater samples. Samples were taken at two sites in Baranya county, where a mixture of chlorobenzene waste was deposited, causing severe contamination in the environment. Clean-up of these sites demands modern and reliable analytical methods. Several sample preparation techniques were used, such as solid phase microextraction (SPME), supercritical fluid extraction (SFE), and a recently developed thermal desorption method. The applicability of various sample preparation methods was compared by measuring recovery percentages, relative standard deviations and by investigating the matrix dependency of these values. Gas chromatography was used for quantitative determination of chlorobenzenes, using MS, IR, FID and ECD detection techniques. Detection levels were as low as 1 ppt in water, and 10 ppt in soil samples. Chlorobenzene concentration was in the range 1 ppt-1 ppm in water and 100 ppb-100 ppm in soil samples. Identification and calibration of these compounds were performed by quantitative standards. This complex analytical method can be used for rapid and precise quantitative and qualitative determination of chlorobenzenes.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 14
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 47 (1998), S. 305-308 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Silicone phases ; Film thickness ; Large-bore capillary columns
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary A technique is described for determination of the amount of bonded phase in commercial columns. It is adapted to the determination of the real nature and the thickness of a siloxane bonded film. Ten-centimeter samples of column are used. The method is tested for large-bore capillary columns. Applications to kinetic studies are suggested.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 15
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 47 (1998), S. 313-345 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Sample pretreatment ; Coupling on-line to capillary GC ; Robotization
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Sample pretreatment is often the bottleneck of a tracelevel analytical procedure. In order to increase performance, increasing attention is therefore being devoted to combining sample pretreatment on-line with the separation technique that has to be used. In the present review, a variety of procedures in use today for sample treatment coupled on-line to capillary gas chromatography (GC) is briefly discussed. Special attention is devoted to coupled-column techniques such as SPE-GC and LC-GC (SPE, solid-phase extraction; LC, column liquid chromatography) which are topics of much current interest, also because of their frequent use in so-called hyphenated systems.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 16
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 48 (1998), S. 163-165 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Solid-phase extraction ; Urinary steroids ; Terbutaline treatment ; Asthmatic children
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Steroid metabolites have been measured by capillary gas chromatography in the urine of 38 children aged 3–6 years. The children comprised three groups: those with asthma being treated with Terbutaline (13), children with asthma but not undergoing treatment (17), and control children in hospital but free from endocrine diseases (8). There were significant (P〈0.05) differences between the amounts of steroids excreted by the different groups of children. Terbutaline therapy led to elevated levels of tetrahydrocortisone, androstenediol, 11-ketopregnanetriol and a reduced ratio of androgen to cortisol metabolites compared with those for untreated asthmatic children. We assume that Terbutaline does not have a steroid-like mechanism of action but acts by modification of the activity of several adrenocortical enzymes. We suggest a hypothesis whereby the antiasthmatic effect of Terbutaline could not only be a connected with its well-known mechanism of action, but it might be explained as a result of the modification of the production of certain glucocorticoids and androgen hormones.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 17
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Calix[4]arene-tetramethyldisiloxane stationary phases ; Geometric and positional isomer separations
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Poly(p-tert-butyldimethoxydipropyloxycalix[4]arene-tetramethyldisiloxane) (TBCX-TMDS) and poly(dimethoxydipropyloxycalix[4]arene-tetramethyl-disiloxane) (CX-TMDS), have been prepared and used as stationary phases for isothermal capillary gas chromatographic separations of positional isomers. Retention factors and separation factors for the isomers were measured. The isomers investigated were well-resolved on the two phases. Retention of all the solutes investigated is greater on TBCX-TMDS than on CX-TMDS, probably because of extra dispersive interactions of the solutes with thetert-butyl groups of the phase. Separation factors for closely-eluting isomer pairs are similar on the two phases. This seems to indicate either that the solutes are retained by non-inclusion processes or that if the isomer molecules do enter the cavity of the calixarene, i.e. the solute is retained by inclusion, thetert-butyl groups do not play a role in discriminating between the isomers.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 18
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 48 (1998), S. 443-449 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Gas chromatography-mass spectrometry ; Triethanolamine in air
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Low amounts of triethanolamine, collected in ORBO 53 tubes during air sampling, required the development of a very sensitive method for determination. After desorption and silylation reaction with trimethylsilyl imidazole/trimethyl chlorosilane, the derivative was analyzed by gas chromatography-mass spectrometry on an Ultra 2 silica capillary column in single ion monitoring mode (retention time: about 6 min). The method has a detection limit of 1–2 pg with a desorption efficiency of about 81%. Linearity of response was ascertained in the ranges 10–100 ng and 100–1000 ng. Short-term method validation was carried out by intra- and inter-day assays on three amounts for each reference calibration curve. All results satisfied the pre-defined acceptance criteria. In general, the whole procedure was easily performed and was appropriate for our needs. Breakthrough volume was appropriate for our needs. Breakthrough volume was determined on authentic samples and was about 40–60 L, using a flow rate of 1 L·min−1. The amounts of triethanolamine found in the samples ranged from 150 to 250 ng (about 2.5–4.2 μg·m−3).
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 19
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Chiral separation ; Alcohols ; Diols ; Trimethylsilylation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Gas chromatographic chiral separation of several chiral 2-and 3-alkanols and diols was studied both in their free hydroxyl and in their trimethylsilyl ether forms. First, the derivatization procedure was verified through the identification of the trimethylsilyl ethers formed on the basis of their mass spectra and optimized to obtain quantitative reaction. The optimized procedure was applied to the trimethylsilylation of racemic mixtures of various hydroxyl compounds. The silylation was found to be highly effective in the improvement of the separation of the individual enantiomers. The major advantages of the derivatization process can be summarized as: (i) excellent baseline separation of the enantiomers of the silyl ethers was achieved in contrast to the parent OH-containing compounds, (ii) the sensitivity of detection highly increased, (iii) the separations do not show any significant concentration dependence and finally (iv) the analysis time needed decreased significantly.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 20
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Atomic emission and MS detection ; Solid-phase extraction ; Aqueous samples
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary A procedure is described for the (non-target) screening of hetero-atom-containing compounds in tap and waste water by correlating data obtained by gas chromatography (GC) using atomic emission (AED) and mass selective (MS) detection. Solid-phase extraction (SPE) was coupled on-line to both GC systems to enable the determination of microcontaminants at the 0.02–1 μg L−1 level in 7–50 mL of aqueous sample. The screening was limited to compounds present in at least one heteroatom-selective GC-AED trace above a predetermined concentration level. These compounds were identified by their partial formulae (AED) and the corresponding mass spectra, which were obtained from the GC-MS chromatogram via the retention index concept. The potential of the approach was demonstrated by the identification of target compounds as well as all unknowns present in tap and waste water above the predetermined threshold of 0.05 μg L−1 (tap water) or 0.5 μg L−1 (waste water).
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 21
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 48 (1998), S. 817-822 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Crown ether capped cyclodextrin ; Chiral separations ; Isomer separations
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary The solution of a new synthesized compound, mono-6-(1'-benzo-aza-15-crown-5)-2, 3, 6- permethyl-β-cyclodextrin, in the moderately polar polysiloxane OV-1701 was coated onto fused silica capillary column. The chromatographic characteristics including column efficiency, polarity and selectivity were studied. Excellent selectivity for the separation of enantiomers and positional isomers was obtained. The results show that the combined effect between the special caves of β-cyclodextrin and crown ether plays a significant role in the separation.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 22
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; UV-Vis detection ; Gas phase absorption spectrometry ; Alcohols
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary This article describes a theoretical/practical study of the parameters which affect the chromatograms obtained when using a molecular diode-array spectrometer as the detector in gas chromatography. The objective is to offer some rules which permit the identification of the optimum signal/noise relation. To achieve this, we study the effect of the different parameters which affect the noise and how to reduce their impact, as well as alternatives for increasing the signal. All the options tested can be applied by correctly programming the spectrometer with BASIC programs, within reach of any use who has even a small understanding of programming. Finally, we consider the effect that the selection of the acquisition conditions may have on the chromatographic resolution. All the studies are carried out using a mixture of alcohols and phenols.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 23
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Liquid crystal stationary phase ; Packed columns
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary The separation ofm-, p-, o- xylenes andm-, p- ethyltoluenes was studied on a packed column with 2,5% of 4-[(4-chlorobenzyl)oxy]-4′-cyanoazobenzene (CBOCA) on Chromosorb W HP 100–120 mesh. The synthesis and study of the mesomorphic behaviour of CBOCA are presented. Temperature range for the separation ofm-, p-, o- xylenes (in this order of elution) is 125–85°C, at cooling. The best separation was achieved at about 90°C. The separation temperature domain ofm-ethyltoluene fromp- ethyltoluene is 160–85°C.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 24
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 48 (1998), S. 436-442 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Water analysis ; Derivatization with bromine ; Aromatic amines
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary For improved determination of aromatic amines by gas chromatography and detection with an electron capture detector (GC-ECD) a derivatization method based on the bromination of the aromatic ring in an acetic acid medium was developed. In general, all free ortho and para-positions relative to the amino group undergo electrophilic substitution. Separation of at least 30 compounds in a single chromatographic run in 30 min is possible. With this method, 56 aromatic amines were studied and only in 6 cases were no derivatives obtained. Quantitation limits determined from calibration data are 1.2–40 μg L−1 for a 100 mL sample and an injection volume of 1 μL. Previous experiments suggest that both sample and injection volume may be increased to lower the quantitation limit.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 25
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Soil samples ; Microwave-assisted solvent extraction ; Nitrogen detection ; Triazine herbicides
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Recent work demonstrated that the combination of microwave assisted solvent extraction (MASE) and capillary gas chromatography with selective nitrogen detection (GC-NPD) is a viable approach for the efficient determination of triazine herbicides in soils. However, for soils with a high organic matter content or the injection of more concentrated extracts to obtain lower LOD's the performance of gas chromatographic analysis of uncleaned extracts is hampered. This results in both a decrease of the chromatographic response of analytes and a decrease in the life time of the column due to coextracted matrix substances. The effect of various types of soils on the chromatographic analysis of triazine herbicides was studied. It appeared that for the investigated samples with an organic matter content below 5% processing of uncleaned extracts is possible. Samples with a higher organic matter content required a cleanup step. A rapid procedure on 100 mg silica cartridges has been developed using solvents compatible with the MASE extracts and the instrumental analysis. Beside the testing with different standard soils, about 120 samples of an ongoing monitoring program involving three different types of soil (organic matter content: 3–37%) were analysed. The selected compounds atrazine, desethylatrazine, desisopropyl-atrazine and simazine could be assayed in the various soil types to a level of at least 2 μg kg−1. For soil samples with a high organic matter content (〉5%), the rapid cleanup procedure allowed the trace analysis of the triazines and considerably increased the life time of the capillary column. Recoveries at levels from 2 to 50 μg kg−1 ranged from 70 to 100% with RSDs ranging from 5.1 to 9.5%. Confirmation of positive samples was carried out by gas chromatography mass spectrometry.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 26
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; On-line SPE-GC-MS ; Beverage carton packages ; Contaminant
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary An unknown migration contaminant was found in a number of mineral water samples contained in beverage carton packages. This compound was isolated by a fully automatic solid phase extraction system and identified by means of GC-MS as 2,4,7,9-tetramethyl-5-decyne-4,7-diol (TMDD) [126-86-3], which is used as a surfactant in water-based printing inks and migrates during the production of the beverage carton material into the inner polyethylene film and subsequently into the product. The determined concentrations of TMDD ranged up to more than 50 μg L−1.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 27
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Column liquid chromatography ; Solid-phase microextraction ; Local anaesthetic lidocaine ; Optimisation of extraction
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Solid-phase microextraction (SPME) has been combined with gas chromatography (GC) and liquid chromatography (LC) for the determination of lidocaine in human urine. A polydimethylsiloxane (PDMS) coated fibre was directly immersed into buffered urine. Extraction conditions such as time, pH, ionic strength, temperature, and agitation were optimised. The extracted lidocaine was thermally desorbed in a split/splitless injector for analysis with a GC-FID system or desorbed with liquid in a specially designed SPME-LC interface for analysis with an LC-UV system. After optimisation the method developed was evaluated and validated. Extraction yields of 22% were obtained in about 45 min. The reproducibility of the method is 〈5% (relative standard deviation). For five-times diluted urine, linear ranges were found from 5–1000 and 25–1000 ng·mL−1 for SPME-GC and SPME-LC, with detection limits of 5 ng·mL−1 for SPME-GC and 25 ng·mL−1 for SPME-LC. SPME can be used as a simple sample pretreatment method for the determination of lidocaine in urine by GC and LC.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 28
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Stationary phases ; β-Cyclodextrin derivatives
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Five β-cyclodextrin derivatives, heptakis[2,6-di-O-pentyl-3-O-(4-nitrobenzyl)-β-CD (CD-I), heptakis [2,6-di-O-pentyl-3-O-(5-hexenyl)]-β-CD (CD-II), heptakis-(2, 6-di-O-cinnamyl-3-O-methyl)-β-CD (CD-III), heptakis-(2, 6-di-O-cinnamyl-3-O-acetyl)-β-CD (CD-IV) and heptakis(2, 6-di-O-cinnamyl-3-O-trifluoroacetyl)-β-CD (CD-V), were synthesized and coated on fused-silica capillary coluns. Their chromatographic characteristics were tested and compared with heptakis (2,3,6-tri-O-pentyl)-β-CD (CD-VI) and heptakis (2,6-di-O-pentyl-3-O-trifluoroacetyl)-β-CD (CD-VII). It was found that the size, polarity, and aromatic property of the substituted group at the 3-position of heptakis (2,6-di-O-pentyl)-β-cyclodextrins greatly influenced their chromatographic properties and separation ability. The introduction of aromatic group or a group containing a double-bond may bring π-π interactions between the host and guest molecules, and therefore increased the separation ability of the β-CDs for substituted benzene isomers. Introduction of cinnamyl groups in to the 2,6-3-position of β-CD has a significant effect on the chromatographic properties of the stationary phases(CD-III-CD-V).
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 29
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Heats of vaporization ; Gibbs free energies ; Kováts retention indices ; Alkylbenzenes
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary In our paper we propose a new method for the determination of heats of vaporization (ΔH vap(i)) and the Gibbs free energies of vaporization (Δμp(i)) for individually selected alkylbenzenes, chromatographed on stationary phases of low and medium polarity. The method is based on a new thermodynamic description of the Kováts retention index (I (i)) making use of Trouton's rule. In fact, we attribute physical significance to two empirical relationships, well known from the literature. We can describe thermodynamically the magnitude ofI (i) using two relations, each of them potentially useful for further determination of δH vap(i) and Δμp(i). A comparison was made of the results obtained with the use of our new approach and of those already existing in the literature attained in a completely different way. The comparison suggests that the calculated δH vap(i) and Δμp(i) values are thermodynamically acceptable and hence correct, and the data suit into the series of similar values determined on stationary phases of different polarity.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 30
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Solid phase extraction ; Polychlorobiphenyls ; Clorinated pesticides ; Organochlorine separation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Gas chromatography of polychlorinated biphenyls and chlorinated pesticides in water samples is carried out after adsorption from a 25–500 mL sample, on a cartridge containing 100 mg aminopropyl-bonded porous silica. The clean-up step in which the PCBs and chlorinated pesticides are separated in different eluates is achieved by passing 25 mL of 40% aqueous methanol through the NH2 Sep-Pak cartridge. The PCBs are desorbed with 500 μL ethylacetate, which is concentrated and analysis by GC-ECD. The average recovery, at 1 ppb is 〉97% with a standard deviation 〈2. The limits of detection are 0.1 ng μL−1 and 5 pg μL−1 respectively for Cl3-PCB and Cl8-PCB congeners. In the separation of PCBs from the chlorinated pesticides tested in this work, only the Aldrin is adsorbed for 60% with the PCBs by the NH2 Sep-Pak cartridge. The method described is rapid, simple and reproducible.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 31
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 48 (1998), S. 728-738 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Stationary phases ; Prototypical phases ; Retention model ; Retention value ; Dipolarity
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Stationary phases are characterised in a multilinear retention model by retention data of a set of selected prototypical substances. Prototypical stationary phases confirm the application of prototypical substances in the retention model. For comparison, 27 stationary phases are characterized with solute descriptors of the solvation model. New adjusted substance factors are calculated for 33 selected compounds for a new characterization of GC stationary phases in the extended retention model with retention values, calculated from retention indices and b-values of the n-alkane equation. Substance dipolarityD N-factors are separated from πN, the adjusted dipolarity-polarisability. New substance factors give satisfying correlation results and new explanatory factors as phase descriptors for 27 stationary phases.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 32
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 48 (1998), S. 758-762 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Butyric acid ; Milk fat content ; Mixed fats
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Quantitation of the milk fat content in mixed fats is of interest in food analysis. It can be achieved by calculation from the butyric acid (C4) content in the mixed fat and a mean C4 content for pure milk fats. Alternatively, instead of applying a C4 mean value, the C4 content in the actual milk fat can be used if this reference sample is available. A recently improved analytical method based on gas chromatography of butyric acid methyl ester using an internal standard has been applied to determine the milk fat content in mixtures with beef tallow, lard, soybean oil, olive oil, sunflower oil, palm kernel oil and palm oil ranging from 1 to 90% milk fat content. Within the whole range of mixtures, mean absolute deviations between the determined and the actual milk fat content were below 0.5% and the maximum absolute deviation was not more than 1.0% when using the reference sample. The overall mean absolute deviation was 0.04% for milk fat contents of 1 to 10% and 0.28% for milk fat contents of 10 to 90%.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 33
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Solid phase extraction ; Brazilian sugar cane spirit ; Lower fatty acids
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary A gas chromatographic method for the analysis of seventeen acids in a water/ethanol matrix is described. The diluted samples were first concentrated by solid phase extraction. Nonanoic acid was the internal standard. A good separation profile was obtained for all compounds, including the isomers: n and iso-butyric acids, n and isovaleric acids and n and iso-caproic acids. The method is fast, sensitive (20–30 μg L−1) and has a good reproducibility (4–7 %). The recovery was in the range of 94%–116% for the medium chain acids (C7-C16). This method allowed the identification of fourteen acids in caninhas and other spirits. The total acid content and the profile of the exportation type caninhas are similar to the ones obtained for several international beverages.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 34
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; UV-Vis detection ; Gas phase absorption spectrometry ; Derivatization ; Alcohols and phenols
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary A method is proposed for the determination of alcohols and phenols based on their derivatization to benzoates and gas chromatography-gas phase molecular absorption spectrometry. All parameters affecting the derivatization reaction, such as the solvent, basic medium, benzoyl chloride and stirring time, were optimized. Chromatographic and instrumental conditions were also studied. Finally, a calibration study was performed and the results were compared to that obtained by the direct determination of the compounds.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 35
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 48 (1998), S. 156-157 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Gel permeation chromatography ; Organophosphorous pesticides ; Plant samples
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary The work presents a GC method for the determination of six organophosphorous pesticide residues in cabbage. Chopped cabbage was blended with acetone, then extracted with the mixture of n-hexane:methylene chloride (1:1). The extract was purified on a GPC column packed with BioBeads SX-3 gel. The pesticides were eluted with the mixture of methylene chloride:cyclohexane (1:1) at the flow rate of 0.5 mL min−1. After concentrating the extract was analysed by GC. Nearly 100 samples of cabbage were analysed; trace residues of dimethoate (about 0.05 ppm) were found in 10 samples. The average recoveries of the pesticides were above 80% with a relative standard deviation mostly less than 10%.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 36
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Solid-phase extraction ; Rapeseed oil ; Sterols
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary A capillary gas chromatographic method is described for the determination of major plant sterols and cholesterol in edible oils and fats. In the sample preparation procedure reversed-phase, solid-phase extraction with C18 adsorbent was used to extract the unsaponifiable matter and for sample cleanup after saponification. Sterols were quantitated as their trimethylsilylether derivatives using an internal standard method (betulin). The method was validated by recovery tests and analysis of two reference materials representing vegetable oil mixture and milk fat matrices. Average recoveries of spiked cholesterol and cholesterol acetate in rapeseed oil were 103±4% (n=12) and 101±3% (n=10), respectively. The sterol values determined in the reference materials were found to be in a good agreement with their given certified or indicative values. Applied to edible oils and fats, plant sterols and cholesterol at levels〉20 mg kg−1 could be accuratively quantitated.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 37
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 48 (1998), S. 299-304 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Headspace sampling ; Ethoxylated alcohols ; Ethoxylated alkylamines
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Headspace-gas chromatography was used to determine the contents of toxic 1,4-dioxane, ethylene oxide and ethylene glycol in ethoxylated alcohols and alkylamines, and in commercial cosmetics and washing products. A Permaphase PEG capillary column was used for the determination of 1,4-dioxane and ethylene oxide and a DB-17 column for ethylene glycol determination. Dimethylformamide was used as the solvent in the determination of 1,4-dioxane and ethylene oxide, and undecanol in the case of ethylene glycol. The detection limits for ethylene oxide, 1,4-dioxane and ethylene glycol are 1,2 and 10 μg·g−1, respectively.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 38
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 47 (1998), S. 689-694 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Stationary phases ; Calix[4]arene derivatives
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Two new kinds of calix[4]arene derivatives, 5,11,17,23-tetra-tert-butyl-25,27-bis(isopropylcarbamoyl-methoxy)-26,28-diundecenyloxy calix[4]arene (C[4]A) and 25,27-dibutoxy-5,11,17,23-tetra-tert-butyl-26,28-diundecenyloxy calix[4]arene (C[4]B), have been synthesized for use as stationary phases in capillary gas chromatography with OV1701. These stationary phases demonstrate high column efficiencies, wide operating temperature ranges, good thermal stability and excellent selectivity for aromatic isomers, especially phenol compounds. Their inclusion properties are also discussed.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 39
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 47 (1998), S. 721-723 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Correlation equation ; Alkylbenzenes ; Naphthalenes
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary A detailed statistical analysis is presented for comparing the validity of selected literature-recommended equations with the unified retention index concept for calculating the retention indexes of alkylbenzenes on UCON LB 550X and naphthalenes on polydimethylsiloxane. Comparison with literature sources shows that the unified retention index provides the smallest residual error for a set of aromatic hydrocarbons.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 40
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Pyrolysis GC ; Residual polystyrene ; Streptomycin ; Vitamin B1
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Residual synthetic adsorbent, cross-linked polystyrene, used in drug purification has been analyzed quantitatively by Curie-point pyrolysis gas chromatography. The peaks of intact polystyrene adsorbent in the pyrogram were used as key peaks for quantitative measurement of residues of the adsorbent in vitamin B1 and streptomycin sulfate. It was shown that them-ethylstyrene orp-ethylstyrene peaks in the pyrolyzates were suitable for determination of polystyrene adsorbent content. The levels of residual adsorbent in the drugs were found to be 〈0.1 %, the value stipulated by the International Conference on Harmonization (ICH). In quantitative evaluation of an adsorbent content of 0.1 % the precision was 3.6 % and 2.7 % for vitamin B1 and streptomycin sulfate, respectively.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 41
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 47 (1998), S. 230-233 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Alkenes ; Epoxides ; Retention index
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Retention indices or five 1-alkenes, seven branched alkenes and five cycloalkenes and the corresponding epoxides were determined at two temperatures on a fused-silica capillary column coated with cyanopropyl methyl siloxane to interpret their chromatographic behaviour. The standard deviation was 0.2 index units.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 42
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 47 (1998), S. 685-688 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Headspace sampling ; Safrole ; Asarum species
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary The development of a headspace GC method (HS-GC) to determine the safrole content in differentAsarum species from China and Europe, using eugenol as internal standard, is presented in this paper. The best results could be achieved by thermostating the samples at 100°C for 30.0 min, adding 10 μL of water to each sample. Optimum pressurisation and injection time showed to be 3.0 min and 12 s, respectively. GC separation was performed on an SE-54 column. The HS-GC results for safrole were in good agreement with those obtained by direct GC analysis of the dichloromethane (DCM) plant extracts. The investigated Asarum samples showed great deviations concerning the safrole content even within the sameAsarum species, e.g.Asarum himalaicum from Sichuan contained 0.0051% of this compound, the same species from the province of Hebei 0.53%.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 43
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 47 (1998), S. 724-726 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Phthalate esters ; PVC ; Plastic toys
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary A method for the analysis of 10 phthalate esters in plastic toys is described. The samples are soxhlet extracted in dichloromethane and phthalate esters in the extract are analysed by GC. Detection limits of dimethyl phthalate, diethyl phthalate, dibutyl phthalate, bis(2-ethylhexyl) phthalate, di-n-octyl phathalate, di-n-nonyl phthalate, benzyl butyl phthalate and benzyl octyl phthalate were approximately 5 ppm. The detection limits of diisononyl phthalate and diisodecyl phthalate, which are mixtures of several isomers, were approximately 200ppm. Analysis of 17 plastic toys revealed that only PVC-toys contained phthalate esters. Bis(2-ethylhexyl) phthalate, diisononyl phthalate and diisodecyl phthalate in concentrations up to 40% were present in the PVC-toys.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 44
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Solid-phase microextraction ; Headspace sampling ; Cyanide in blood
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Cyanide can be extracted from whole blood samples by headspace solid-phase microextraction (SPME) with a Carbowax/divinylbenzene-coated fiber. During heating a vial of a whole blood sample containing cyanide and acetonitrile as internal standard (IS) at 50°C in the presence of Na2SO4, a Carbowax/divinylbenzene-coated SPME fiber was exposed in the headspace of the vial for 45 min to allow adsorption of cyanide and IS. The fiber needle was then injected into a capillary gas chromatography (GC) instrument equipped with nitrogen-phosphorus detection. The headspace SPME-GC with a Supel-Q PLOT fused silica capillary column gave large peaks for cyanide and IS; almost no interfering peaks appeared. Recoveries of cyanide dnd IS from human whole blood were 3.02–4.06% and 0.21%, respectively. The calibration curve for cyanide added to human blood showed excellent linearity in the range of 0.04–4.0 μg mL−1; the detection limit was about 0.02 μg mL−1. The coefficients of intra-day and inter-day variation were not greater than 7.1 and 9.2%. Good correlation (r 2=0.999) was found between the present SPME-GC method and the conventional microdiffusion colorimetric method. Data on determination of cyanide in rat blood after intraperitoneal administration are also presented.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 45
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Mixed stationary phases ; Dibenzo-18-crown-6 ether ; MPBHpB ; Synergistic effects
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary The synergistic effect is investigated in mixed gas chromatographic stationary phases containing dibenzo-18-crown-6 +MPBHpB [o-methyl-p-phenylene-bis-(p-heptoxy benzoate)], [o-methyl-p-phenylene-bis-(p-heptoxy benzoate)], with benzene/cyclohexane, cyclokexanes, phenols, alcohols and aniline derivatives as sample compounds pairs. Some of the separations reveal positive or negative synergistic effect. This effect depends on the temperature, the mixing ratio and the linear velocity of the carrier gas.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 46
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Organochlorine and organophosphorus pesticides ; Herbal medicine ; Essential oils ; Sulfuric acid treatment
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary A rapid and new clean-up method utilizing sulfuric acid treatment is demonstrated to identify and quantify the level of organochlorine (OC) and organophosphorus (OP) pesticide residue concentrations in herbal essential oils by gas chromatography (GC). Essential oils fortified with pesticides, that are extracted from herbs by steam distillation are partitioned with 65% acetonitrile/water(v/v) and treated with sulfuric acid at different reaction times and sulfuric acid concentrations. Optimal conditions, to avoid interference from essential oils in gas chromatographic analysis, is 17% (v/v) of a mixed phase ratio of sulfuric acid to organic solvent (hexane/ethyl ether=9∶1, v/v) and a reaction time of 30s. The response of the flame ionization detector (FID) is linear for all pesticides determined. Recovery of pesticides from fortified herbs studied are in the range of 75% to 111% (RSD, 4% to 11%) for OC, and 72% to 116% (RSD, 2% to 11%) for OP. Although sulfuric acid treatment destroys carbamate and some organophosphorus pesticides, this method has efficiently reduced matrix interference and provides a rapid, economical clean-up method with excellent linear data having low coefficients of variation for the GC analyses of BHC isomers, DDD, DDE, DDT, chlorothalonil, chloropyrifos, tetradifon, fenitrothion, malathion, and parathion in matrices of herbal essential oils.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 47
    ISSN: 1612-1112
    Schlagwort(e): Column liquid chromatography ; Gas chromatography ; Enantiomeric separation ; Chiral derivatization ; Unusual secondary aromatic amino acids
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary High-performance liquid chromatographic and gas chromatographic methods were developed for the separation of unusual secondary aromatic amino acids. Amino acids containing 1,2,3,4-tetrahydroisoquinoline, 1,2,3,4-tetrahydronorharmane-1-carboxylic acid and 1,2,3,4-tetrahydro-3-carboxy-2-carboline moieties were synthetized in racemic or chiral forms. The high-performance liquid chromatography was carried out either on a teicoplanin-containing chiral stationary phase or on an achiral C18 column. In the latter case the diastereomers of the amino acids formed by precolumn derivatization with the chiral reagents 2,3,4,6-tetra-O-acetyl-β-D-glucopyranosyl isothiocyanate or 1-fluoro-2,4-dinitrophenyl-5-L-alanine amide were separated. The gas chromatographic analyses were based on separation on a Chirasil-L-Val column.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 48
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 48 (1998), S. 86-88 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Solid phase extraction ; Methoxime-silyl derivate ; Urinary steroids ; Women with effluvium
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Urinary steroid metabolites were measured by capillary gas chromatography in 25 women (aged 33.3±12.0 years) with effluvium and 16 control healthy laboratory workers women (aged 34.6±8.4 years). There was significant elevation in the level of a number of steroids and steroid metabolites. The elevation of most steroid metabolites refers to the increased steroid secretion of the adrenal and the high cortisol metabolites levels may be do to stress in some of the patients with effluvium.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 49
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Chiral stationary phases ; Enantioseparation ; Toxaphene
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary The separation of the enantiomers of the compounds of technical toxaphene (CTTs) on heptakis(6-O-tert-butyldimethylsilyl-2,3-di-O-methyl)-β-cyclodextrin (β-TBDM) has been studied by gas chromatography with electron-capture detection (GC-ECD). Enantiomers of eight of the nine CTTs under investigation were separated on this chiral stationary phase. Separations of the enantioners of CTTs have hitherto been achieved ontert-butyldimethylsilylated β-cyclodextrin (β-BSCD). The chiral resolution values and separation factors of the CTTs on β-TBDM have been compared with those obtained on β-BSCD. Although several components coeluted, enantioselective determination of three CTTs was possible in an extract of seal blubber. For each CTT the first-eluting enantiomer was enantioenriched. Enantioselective accumulation of2-endo, 3-exo,5-endo,6-exo,-8,8,9,10-octachlorobornane (B8-1412) in biota has been established for the first time.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 50
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 47 (1998), S. 579-586 
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Column liquid chromatography ; Ewe's cheese ; Triacylglycerols
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Triacylglycerols from Idiazabal cheese fat were analysed by high-performance liquid chromatography (LC) with a non-linear gradient of acetone in acetonitrile and a light-scattering detector. Molecular species of triacylglycerols were predicted by a simple and a multiple linear regression analysis of logk of the LC peaks and molecular variables such as equivalent carbon number of the possible triacylglycerol, chain length and number of double bonds of each fatty acid of the triacylglycerol. Predicted results were confirmed by gas chromatographic analysis of the fatty acids in the LC peaks. The main triacylglycerols of Idiazabal cheese fat contained butyric acid, butyroyl-dipalmitin, butyroyl-myristoyl-palmitin and butyroyl-palmitoyl-olein. The most abundant triacylglycerols were those with even partition numbers of 36, 34 and 38.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 51
    ISSN: 1612-1112
    Schlagwort(e): Gas chromatography ; Metal complexes ; Chemically bonded phases ; Thermodynamic parameters ; Specific interactions
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Results are presented of studies of packings containing copper (II) acetylacetonate (acac), hexafluoroacetylacetonate (hfac), and chloride, chemically bonded via β-dik-etonate groups. The retention parameters retention factor (k) specific retention volume (V g), and molecular retention index (M e) were measured and used to calculate the thermodynamic parameters free energy of adsorption (ΔG a) heat of adsorption (−ΔH a), and entropy of adsorption (ΔS a). These parameters enable, characterization of specific interactions between aromatic and cyclic hydrocarbons, ethers and thioethers and metal complexes chemically bonded, to a silica surface.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...