Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2,328)
  • 1980-1984  (1,714)
  • Atomic, Molecular and Optical Physics  (2,131)
  • Numerical Methods and Modeling  (1,287)
  • Gas chromatography
  • Nuclear reactions
Material
Years
Year
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European food research and technology 209 (1999), S. 400-406 
    ISSN: 1438-2385
    Keywords: Key words Pumpkin seed oil ; Oil adulteration ; Δ7-Phytosterols ; Sample clean-up procedure ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract  A simple and accurate method for the determination of phytosterols by capillary gas chromatography was developed for the analysis of the seeds and oil of the pumpkin Cucurbita pepo L., the naked seed variety growing in the southern Styrian parts of Austria. After extraction of the oil and saponification, the remaining unsaponifiable material was isolated and purified using silica gel columns. For greater volatility, the sterols were derivatised to trimethylsilylethers, and gas chromatography was performed on a column of high polarity, allowing separation of the Δ5-sterols from the Δ7-sterols and thus yielding a typical chromatographical pattern. Quantification of the phytosterols using 5α-cholestan or cholesterol as internal standards led to a method of high accuracy. Comparison of the chromatographic pattern of the phytosterol fraction of pumpkin seed oil with those of other vegetable oil samples permitted the use of this method to detect adulteration of pumpkin seed oil.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Rechtsmedizin 9 (1999), S. 184-189 
    ISSN: 1434-5196
    Keywords: Key words Ethyl glucuronide ; Congeners of alcoholic beverages ; Alkyl glucuronide ; Gas chromatography ; Mass spectrometry ; Schlüsselwörter Ethylglucuronid ; Begleitstoffe ; Alkylglucuronid ; Gaschromatographie ; Massenspektrometrie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Description / Table of Contents: Zusammenfassung Es wird die chemische Synthese von Alkylglucuroniden beschrieben, die nach Konsum von begleitstoffhaltigen Getränken als Metaboliten im Urin erscheinen. Von folgenden Alkoholen wurden die Glucuronide synthetisiert: Methanol, d5-Ethanol, Propanol, Isopropanol, Butanol, Isobutanol, R-(–)-2-Butanol, S-(+)-2-Butanol, Isopentanol, S-(–)-2-Methylbutanol. Die Retentionsindizes der Acetyl-, Pentafluorpropyl(PFP)- und Trimethylsilyl(TMS)-derivate werden mitgeteilt und der Einfluß der chemischen Struktur auf den RI-Wert diskutiert. Die Massenspektren der homologen Derivate erwiesen sich als sehr ähnlich, aber einige Fragmente sind spezifisch für die Kettenlänge der Alkylgruppe und können zur Identifizierung und Quantifizierung der Glucuronide in Urinproben herangezogen werden.
    Notes: Abstract The chemical synthesis of alkyl glucuronides, which appear as metabolites in urine after the consumption of beverages containing congeners of ethanol, is described. Glucuronides of the following alcohols were synthesized: methanol, d5-ethanol, propanol, isopropanol, butanol, isobutanol, R-(–)-2-butanol, S-(+)-2-butanol, isopentanol and S-(–)-2-methylbutanol. The retention indices of acetyl, pentafluorpropyl (PFP) and trimethylsilyl (TMS) derivatives are given and discussed in relation to the chemical structures. Mass spectra of homologous derivatives were shown to be very similar but some fragments were specific for the chain length of the alkyl moiety and can be used for identification and a quantitative estimation of glucuronides in urine samples.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 333-337 
    ISSN: 1612-1112
    Keywords: Supercritical fluid chromatography ; Gas chromatography ; Solvating gas chromatography ; Peak capacity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In this paper, a general peak capacity expression was evaluated using columns containing various packing materials under solvating gas chromatography (SGC) conditions. Differing from column efficiency, peak capacity can describe both separation capability and speed when introducing the dead time into the peak capacity expression. Various factors that influence peak capacity in SGC are described, including particle pore size, chemical surface modification, particle size, column length, temperature, and pressure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Cisplatin determination ; Blood analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A capillary gas chromatographic method is described for the determination of cisplatin based on the complexation of platinum(II) with bis(isovalerylacetone) ethylenediimine (H2IVA2en) and extraction in chloroform. The chromatography was carried out on a BP1 or a BP5 column with an FID. Copper(II), nickel (II) and palladium(II) separated completely and did not affect the determination of platinum(II). The method was applied of the determination of cisplatin in a pharmaceutical preparation and blood samples of cancer patients after infusion of cisplatin. The amounts of cisplatin in blood were found to be within 246–283 ng mL−1 with a C.V. of 2.35–4.26%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 273-280 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Complexation stationary phases ; Bonding metal complexes ; Capillary columns
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of polysiloxanes with cyano or thiol groups as stationary phases for complexation gas chromatography is discussed. The polymers were obtained via polycondensation followed by polymerisation of the corresponding dichloro- or dimethoxy-silanes. Both the phases were modified by bonding transition metal chlorides with were modified by bonding transition metal chlorides with cyano (CuCl2 or CoCl2) and thiol groups (NiCl2 or CoCl2). The phases were examined in order to determine their application to the analysis of ethers, thioethers and ketones. Due to the presence of lone electron pairs on oxygen or sulphur atoms, the compounds should be capable of specific interacting with the electron-withdrawing centre of the liquid stationary phases. A number of retention parameters (retention indices, molecular retention indices and specific retention volume) were determined, which allowed characterisation of specific interactions between the bonded metal and the compound analysed. The results also enabled assessment of the influence of the structure of the compounds on their retention. The measurements were also carried out for the phases with free SH and CN groups as reference phases. The work demonstrates that the phases obtained may be useful for effective separations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Microwave and ultrasonic extraction ; River sediment ; Dioxin-like polychlorobiphenyls ; Toxic equivalency factors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Microwave extraction and ultrasonication of dioxin-like polychlorobiphenyls (PCBs) from sediment samples were investigated. After separation of dioxin-like PCBs from a sample matrix on an acidic-alkaline silica gel column, dioxin-like PCBs were determined by GC-ECD, using dual capillary columns. Recoveries of dioxin-like PCBs in river sediment samples exceeded 80% by both extraction techniques. Toxic equivalency factors and their use for the PCB congeners investigated were applied.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 513-519 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Solid phase microextraction ; Open cap vials ; Volatile compounds (BTEX) ; Water matrix
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The testing of open cap vials in headspace solid-phase microextraction combined with capillary gas chromatography is reported. The losses of volatile analytes from such vials were analyzed theoretically and investigated experimentally. The benzene, toluene, ethylbenzene, and xylene isomers spiked in water were used as model compounds. Extraction yields and precision obtained under optimized experimental conditions as exposure time, desorption time and temperature were compared applying vials with open caps or sealed with teflon lined septa.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 385-390 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Structure correlations ; Polycyclic aromatic hydrocarbons ; Polychlorinated biphenyls ; Polychlorinated pesticides
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A composite chromatographic retention index system has been developed for identifying polycyclic aromatic hydrocarbons, polychlorinated biphenyls and polychlorinated pesticides. When retention indices and thermodynamic data of polycyclic aromatic hydrocarbons on 5% phenylmethylsiloxane stationary phase were compared with those obtained on polydimethylsiloxane a correlation was found between retention and electronic properties. Determination and quantitation of individual contaminants in water and sediment samples from Lake Mecoacán were achieved by capillary gas chromatography with flame ionization and electrocapture detection.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 399-405 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Solid phase adsorption ; Supercritical fluid extraction ; Sewage ; Organic pollutants
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Analytical methods have been developed for the determination of organic pollutants of intermediate polarity in sewage. Water samples are first passed through a solid phase adsorption cartridge. The analytes are then extracted from the absorbent with supercritical CO2 into a small volume of trapping solvent. Finally, the extracts are analyzed directly by capillary gas chromatography and gas chromatography-mass spectrometer. The various parameters (pressure, temperature, type and concentration of modifiers, trapping solvent, flow rate and volume of supercritical fluid and equilibrium time) influencing the efficiency of extraction were studied. Extraction efficiencies for the test compounds are 〉70%, and relative standard deviations are 〈4.6% (n=3). The methods established were applied to the analysis of sewage at the Lanzhou Wastewater Treatment Plant, China. 66 organic pollutants were detected, of which 15 compounds appeared in the list of priority pollutants suggested by the US EPA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 509-512 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Homologous series ; Retention times
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary It is shown how to estimate the retention times of homologous series members in linear temperature programmed gas chromatography with the aid of a spread-sheet. Both the ease of estimation and the accuracy of the estimation depend on whether the homologue is eluted during the rising portion of the temperature program or the hold time at the end, and also on whether the homologous series is eluted from one injection or a number of injections. When all members of the series elute in the one chromatographic run the percentage standard deviation of the predicted retention times from the experimental retention times is 0.1. When members of the series elute in different chromatographic runs, the percentage standard deviation of predicted times from experimental times is 0.6, compared with an experimental percentage standard deviation for replicates of 0.5.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 11
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Average column pressure ; Average column flow ; Specific retention volume ; Distribution coefficient
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A systematic derivation of corresponding equations shows that averaging the pressure and the flow rate of the mobile phase in a gas chromatographic column over the column length and over the time that an unretained component resides in the column, requires the use of three different compressibility correction factors,j 2 1 ,j 3 2 , andj 4 3 . When multiplied by the adjusted retention volume,V R-VM, the Martin and James mobile phase compressibility correction factorj 3 2 , only, produces the value of specific retention volume,V g T , which is connected unambiguously with the thermodynamic phase distribution coefficient,K, of the sorbate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Reversed-flow gas chromatography ; Carbon monoxide oxidation ; Bimetallic Pt−Rh catalysts
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Catalytic fractional conversions of carbon monoxide to carbon dioxide over Pt−Rh alloy catalysts in the presence of excess oxygen, under steady-state or non steady-state conditions, as well as corresponding rate constants for the CO oxidation reaction were measured by using the reversed-flow gas chromatographic technique. From the variation of the conversions with temperature, maximum values of conversions were found, which depend on the catalysts nature (Pt content), while from the variation of the rate constants with temperature, activation energies for the CO oxidation reaction were determined, which also depend on the catalyst Pt content. The results suggest a synergism between Pt and Rh in the Pt−Rh bimetallic catalysts in accordance with previous works, showing that reversed-flow gas chromatography can be used with simplicity and accuracy for the kinetic study of the CO oxidation reaction, which is of technological importance for the control of air pollution.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 321-326 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Headspace analysis ; Open-tubular trap ; Very thick film column
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An open-tubular trap with a very thick film was studied for “full on-line” headspace capillary gas chromatography, and was used as an enrichment trap for headspace sampling. The preparation of the open-tubular column with up to an 80 μm thick film, by combining both static and dynamic coating, is described in detail. The break-through volume for the open-tubular trap of different film thickness, as the loading capacity for HS sampling, does not increase linearly in proportion to the film thickness. A study of the difference between a packed adsorbent trap and an open-tubular trap shows that HS capillary GC with open-tubular trap loses less of the retention capacity, has better resolution ability and higher recovery. By independently and rapidly heating the open-tubular trap, the GC peaks may have higher resolution. Examples of successful analyses, by the opentubular trap with “full on-line” HS capillary GC, include trace aromatic hydrocarbon (1 ppm-100 ppm) in polybutadiene-styrene rubber and trace alcohol and acrylic esters (10 ppm–1000 ppm) in polyacrylate hydrous emulsion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 112 (1999), S. 124-131 
    ISSN: 1437-1596
    Keywords: Key words Hydroxyproline ; D/L Aspartic acid ; N-TFA isopropyl ester derivatives ; Gas chromatography ; Collagen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Notes: Abstract The proportion of D- to L-enantiomers of aspartic acid in metabolically isolated proteins has been used by forensic scientists to estimate age at death. We have demonstrated the interference of a derivative of hydroxyproline (N-TFA isopropyl Hyp ester) with the N-TFA isopropyl L-Aspartic (Asp) acid ester during gas chromatography of amino acids. This has serious implications for the accurate quantification of the D- to L-Asp ratio extracted from collagenous proteins. Having demonstrated the potential for this co-elution in amino acid standards, acid-soluble dentine proteins and non-mineralised collagen, we argue that this problem can be overcome either by high resolution separation or by analysis of the (Hyp-poor) non-collagenous protein fraction.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 24-28 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; ECD ; Micro-ECD ; GC detector ; organochlorine pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A new ECD, the HP 6890 Series Micro-ECD, was designed to address inherent deficiencies in classical electron capture detectors (ECD), especially with respect to sensitivity, linearity, dynamic range, and ruggedness. Several novel technologies were incorporated in the totally new design and were refined through practical testing and user feedback. Validation of the micro-ECD performance was accomplished through side-by-side testing of the Micro-ECD with previous ECDs following US EPA Contract Laboratory Program methods for pesticides and PCBs. In addition, extensive interviews were conducted with early users of the Micro-ECD who also had experience with other designs running a variety of ECD methods. The design and resulting performance improvements are described.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 303-304 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; food analysis ; pesticide residues ; thiabendazole ; imazalil ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 395-402 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; pulsed splitless injection ; pesticide residues ; matrix effects ; retention gap ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The applicability of pulsed splitless injection to the gas chromatographic analysis of pesticide residues in fruit and vegetables has been evaluated. 22 pesticides belonging to different chemical classes, including those known to be liable to matrix induced response enhancement, were selected for the study. The parameters of pressure pulse have been tested for optimum performance of injection. Application of the pressure pulse was found to decrease matrix effects during analyses of real samples. Further decline of matrix effects was obtained using higher sample injection volumes. The installation of a deactivated retention gap was necessary to obtain good peak shapes with injection volumes exceeding 1 μL of sample. Up to 4 μL was then injected without peak distortion and consequent loss of resolution. Using 4 μL pulsed splitless injection, matrix effects were almost completely eliminated even at very low concentration levels of analytes. The highest matrix effects observed for tested compounds at the lowest concentration level tested were in the range of 110-122%.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 565-588 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Kovats retention index ; vapor pressure ; boiling point ; Wilson activity coefficient ; binary phase diagrams ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Non-ideal mixing in a dimethylsilicone stationary phase is modeled according to the Wilson activity coefficient. Pure liquid vapor pressures of alkylated compound series are calculated from capillary GLC retention with the functional group heat of solution in a polymer solvent. The new method uses the Kovats index, molar mass, and functional group to determine the bubble line of a compound. Boiling points at reduced and normal pressure are compared to literature values of 194 gasoline components. An unlike molecular pair interaction parameter is derived, using only bubble line data of the pure liquids. Binary phase diagrams are constructed and compared to vapor liquid equilibrium data.
    Additional Material: 22 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 181-182 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; microwave induced emission spectrometry ; speciation ; mercury ; SPME, headspace SPME ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 294-296 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; capillary ; fused silica ; rotenone ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: No abstract
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 268-272 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Mass spectrometry ; Analytical pyrolysis ; Chinese art objects ; Mercury analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A few samples of polychrome Chinese archaeological objects of art have undergone analytical pyrolysis coupled with GC-MS to evaluated the possibility of contemporary characterization of the pigments as well as the organic media used. The red pigment cinnabar (HgS) is easily media used. The red pigment cinnabar (HgS) is easily detected, whereas in the case of organic components positive results are only found where the matrices are resistant to archaeological environmental conditions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 22
    ISSN: 1612-1112
    Keywords: Gas chromatography ; [60] Fulleropyrrolidine polysiloxane ; High temperature stationary phase
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In this paper, a new type of [60]fulleropyrrolidine functionalized polysiloxane in which the fullerene moieties were incorporated in the main polysiloxane chain was synthesized the first time and used as a stationary phase for capillary gas chromatography. It demonstrated high column efficiency (2600–2866 plates m−1, on a 250 μm diameter column, for naphthalenek=3.1–3.2, 120 °C), a wide operational temperature range (90–360 °C) and outstanding thermostability. It can be used at 360 °C with a baseline drift of 5∼8×10−15A. Benzene homologues, aromatic hydrocarbons, polar compounds such as alcohols, esters, ketones, anilines and phthalic diesters can be seperated well on this column.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 23
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Supercritical fluid chromatography ; Solvating gas chromatography ; Polybutadiene coated zirconia ; CO2 mobile phase
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In this paper, practical considerations of column efficiency, separation speed, thermal stability, and column polarity of capillary columns packed with polybutadiene-coated zirconia were investigated under solvating gas chromatography (SGC) conditions using carbon dioxide as mobile phase. When compared with results obtained from conventional porous octadecyl obtained from conventional porous octadecyl bonded silica (ODS) particles, PBD-zirconia particles produced greater change in mobile phase linear velocity with pressure than conventional ODS particles under the same conditions. The maximum plate number per second (Nt) obtained with a 30 cm PBD-zirconia column was approximately 1.5 times higher than that obtained with an ODS column at 100 °C. Therefore, the PBD-zirconia phase is more suitable for fast separations than conventional ODS particles in SGC. Maximum plate numbers per meter of 76,900 and 63,300 were obtained using a 57 cm×250 μm i.d. fused silica capillary column packed with 3 μm PBD-zirconia at 50 °C and 100 °C, respectively. The PBD-zirconia phase was stable at temperatures up to 320 °C under SGC conditions using carbon dioxide as mobile phase. Polarizable aromatic compounds and low molecular weight ketones and aldehydes were eluted with symmetrical peaks from a 10 cm column packed with 3 μm PBD-zirconia. Zirconia phases with greater inertness are required for the analysis of more polar compounds by SGC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 24
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Solid-phase microextraction ; Fibre coating ; Volatile organic compounds ; Semi-volatile organic compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The efficiency of direct solid-phase microextraction (SPME) was determined for 27 selected volatile and semivolatile organic compounds (BTEX, chloro- and bromobenzenes, chlorinated pesticides and PCBs). The fibres used were 7μm polydimethylsiloxane (PDMS), 30μm PDMS, 100μm PDMS, 65μm PDMS-divinylbenzene, 85μm polyacrylate, 65μm Carbowax-divinylbenzene, 75μm Carboxen-PDMS and a new 65μm C8 fibre. Extraction yields for these compounds were calculated under standardised conditions: 75μm Carboxen-PDMS was found to be the most efficient fibre for compounds with low boiling points. Although 65μm C8 can be used for extraction of all compounds studied, in no one case is it the most effective coating. 100μm PDMS and the more polar coatings can be used for a broad range of compounds, whereas application of 7μm and 30μm PDMS cannot be recommended. Inter-fibre comparison revealed significant differences between three different Carboxen-PDMS fibres. The results enable suitable coatings to be chosen for each of the 27 compounds and for substances with similar properties.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 567-571 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Mixed stationary phase ; Calixarenes ; Crown ethers ; Cyclodextrins
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Mixed stationary phases containing of 25,27-dibutoxy-5,11,17,23-tetra-tert-butyl-26,28-diundecenyloxy calix [4]arene (C[4]B)+ω-undecylomethyl-18-crown-6 polysiloxane (PSO-11-18-C-6) and C[4]B polysiloxane (PSO-C[4]B)+permethyl-β-cyclodextrin (PM-β-CD) were investigated in capillary gas chromatography. By comparing their selectivity for positional isomers with that of the corresponding individual pure stationary phases, synergistic effects were found.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 26
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Electron capture detector ; Anti-picornaviral agent in dog serum ; Enteroviruses
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A gas chromatographic assay for the determination of SCH 48973, a potent broad spectrum anti-picornaviral agent, was developed and validated in dog serum. The method involved extraction with organic solvent followed by separation on a capillary column (DB-1) with quantitation by an electron-capture detector. The method was sensitive with a limit of quantitation of 10 ng mL−1. The linearity of the method was satisfactory as indicated by correlation coefficients of 〉0.999 and visual examination of the calibration curves. The method was precise with a coefficient of variation ranging from 2.3 to 13.2% and accurate with a bias ranging from −9.1 to 7.9%. Moreover, SCH 48973 was stable in dog serum after being subjected to three freeze-thaw cycles. The assay was shown to be sensitive, specific, accurate and precise, and reliable for use in pharmacokinetic or toxicokinetic studies.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 27
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Sorptive preconcentration ; Air monitoring ; Nicotine ; Hospital air
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A novel method for the enrichment of nicotine from gaseous samples is presented. It is based on the sampling of 6 liters of air onto a cartridge packed with 100% polydimethylsiloxane (PDMS) particles. The analytes are dissolved (partitioned) into the PDMS phase which results in much better recoveries and reproducibilities compared to those obtained on common adsorbents. The PDMS tube is then placed in a thermal desorption (TD) unit connected to a CGC-NPD or CGC-MS system. The procedure was employed for routinely monitoring air in a hospital. Nicotine was typically found at levels ranging from 5 to 250 μg m−3 (ppb) depending on the location and number of smokers present. Additionally, the efficiency of nicotine filters was determined by sampling simultaneously at the filter in- and outlet and was found to be 46%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Lebensmittel-Untersuchung und -Forschung 206 (1998), S. 48-51 
    ISSN: 1431-4630
    Keywords: Key words Carbohydrates ; Myo-inositol ; Orange juice quality ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract  A gas chromatographic method using a capillary column is described for the quantitative analysis of fructose, glucose, sucrose and myo-inositol in orange juice. The method is evaluated for precision and recovery using phenyl-β-glucoside as an internal standard. The results support the suitability of the method. Carbohydrates (fructose, glucose, sucrose and myo-inositol) were determined in different kinds of orange juice. The determination of carbohydrate composition and ratios of the carbohydrate constituents provide a method to assess orange juice quality, especially the myo-inositol content and myo-inositol/fructose ratio. These new indices, which were found to be lower in samples made from concentrates, provide information on the quality and genuineness of orange juice.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Lebensmittel-Untersuchung und -Forschung 206 (1998), S. 77-82 
    ISSN: 1431-4630
    Keywords: Key words Anticarcinogen ; CLA ; Conjugated linoleic acid ; Daily intake ; Foods ; Gas chromatography ; Lipids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract  The quantities of the biologically active isomer of conjugated linoleic acid (CLA) – C18:2 c9t11 – in 139 German foods were analysed by capillary gas chromatography (results are given as a % of all identified fatty acid methyl esters). The CLA content ranged from 0.40% (Gouda) to 1.70% (Jurassic cheese, Old Emmentaler) in dairy products, from 0.11% (rabbit) to 1.20% (lamb) in meat, and from 0.01% (pike-perch) to 0.09% (carp) in fish. CLA could be detected in neither vegetable fats or oils nor in margarines (CLA 〈0.01%). Crisps, chocolates, cakes and pastries, and other foods have only a negligible CLA content. The average estimated CLA intake in Germany was calculated to be 0.35g CLA/day for women and 0.43g CLA/day for men.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Lebensmittel-Untersuchung und -Forschung 206 (1998), S. 213-216 
    ISSN: 1431-4630
    Keywords: Key words Milk fat ; Mixed fat ; Milk fat content ; Butyric acid ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract  The analysis of butyric acid (C4) is of importance for the determination of the proportion of milk fat in mixed fats. Three gas chromatographic methods were compared with regard to their precision for the measurement of C4, i.e. analysis of butyric acid methyl ester after trans-esterification of fat by sodium methylate (method A) or trimethyl sulphonium hydroxide (method B), as well as analysis of free butyric acid (method C), using an internal standard with each method. The examination of 30 milk fats which varied greatly in terms of their C4 content, using methods A, B and C, resulted in mean values of C4 of 3.42 g/100 g fat, 3.71 g/100 g fat and 3.06 g/100 g fat, respectively. The value determined using method B seemed too high, and this may have been due to the presence of co-eluting artefacts, whereas the value determined using method C was clearly too low, and can probably be attributed to losses during sample preparation. The standard deviation (SD) of 0.015 obtained from repeated analyses using method A was quite good. Results obtained using methods B and C had SDs of 0.029 and 0.074, respectively. Different levels of free fatty acids did not affect the results obtained using method A. When method A was checked by analysis of the reference fat, CRM 164, the C4 level determined was found to deviate from the certified C4 content of 3.49 (± 0.06) g/100 g fat by only 0.05 g C4/fat 100 g. Thus method A proved the most suitable for the determination of the proportion of milk fat in mixed fats by analysis of butyric acid.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Springer
    Journal of biomedical science 5 (1998), S. 415-420 
    ISSN: 1423-0127
    Keywords: Isoprostanes ; Oxidative stress ; Lipid peroxidation ; Gas chromatography ; Mass spectrometry ; Human disease
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract The development of a specific, reliable and noninvasive method for measuring oxidative stress in humans is essential for establishing the role of free radicals in human diseases. Currently, accurate techniques to assess oxidant injury in vivo are extremely limited although a number of approaches are being investigated. Of these, the measurement of specific products of nonenzymatic lipid peroxidation, the F2-isoprostanes (F2-IsoPs), appears to be a more accurate marker of oxidative stress in vivo in humans than other available methods. The purpose of this brief review is to acquaint the reader with the IsoPs from a biochemical perspective and to provide information regarding the utility of quantifying these compounds as indicators of oxidant stress.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Lebensmittel-Untersuchung und -Forschung 207 (1998), S. 180-181 
    ISSN: 1431-4630
    Keywords: Key words UHT milk ; Storage ; Monosaccharides ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract  Changes in the free monosaccharide fraction and non-casein nitrogen during the 3-month storage of five batches of commercial UHT milk were studied. Batches with high residual proteolytic activity showed a considerable increase in galactose, N–acetyl glucosamine and N–acetyl galactosamine levels during the storage period, whereas their glucose and myo-inositol contents remained unaltered. In batches with slight or negligible proteolytic activity no changes in the free monosaccharide fraction were observed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 24 (1998), S. 415-421 
    ISSN: 1432-1238
    Keywords: Key words Acetone ; Gas chromatography ; Isoprene ; Lipid peroxidation ; Microwave desorption ; N-pentane
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: Application of a new method for analysis of exhaled gas in critically ill patients. Design: Open study. Setting: Surgical intensive care unit of an university hospital. Patients: Thirty-seven consecutive, critically ill, mechanically ventilated patients. Interventions: None. Measurements and results: Chemical analysis of the patient's exhaled gas was based upon substance adsorption and concentration onto activated charcoal, microwave desorption and gas chromatographic separation. Patients with acute respiratory distress syndrome (ARDS) exhaled less isoprene than those without ARDS [9.8 (8.2–21.6) vs 21.8 (13.9–41.4) nmol/m2 per min [median (95 % confidence interval)], p = 0.04]. In patients who developed pulmonary infection, pentane elimination increased from 0.4 (0.0–5.4) to 2.7 (0.6–6.1, p = 0.05) nmol/m2 per min and isoprene elimination decreased from 5.2 (0–33) to 5.0 (0–17, p = 0.05) nmol/m2 per min, resulting in a significant increase in pentane/isoprene ratio from 0.1 (0–0.3) to 0.4 (0–15, p = 0.007) when compared to patients without pulmonary infection. Conclusions: The new method allows quantitative analysis of human gas samples with low substance concentrations and is well suited for clinical studies which involve the investigation of metabolic processes in the lung and the body.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Springer
    Space science reviews 84 (1998), S. 199-206 
    ISSN: 1572-9672
    Keywords: Nuclear reactions ; Nucleosynthesis ; Abundances ; Stars:Evolution ; Interior ; Rotation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We first recall the observational and theoretical facts that constitute the so-called 3He problem. We then review the chemical anomalies that could be related to the destruction of 3He in red giants stars. We show how a simple consistent mechanism can lead to the destruction of 3He in low mass stars and simultaneously account for the low 12C/13C ratios and low lithium abundances observed in giant stars of different populations. This process should both naturally account for the recent measurements of 3He/H in galactic HII regions and allow for high values of 3He observed in some planetary nebulae. We propose a simple statistical estimation of the fraction of stars that may be affected by this process.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 35
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Stationary phases ; Calix[4]arene derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two new kinds of calix[4]arene derivatives, 5,11,17,23-tetra-tert-butyl-25,27-bis(isopropylcarbamoyl-methoxy)-26,28-diundecenyloxy calix[4]arene (C[4]A) and 25,27-dibutoxy-5,11,17,23-tetra-tert-butyl-26,28-diundecenyloxy calix[4]arene (C[4]B), have been synthesized for use as stationary phases in capillary gas chromatography with OV1701. These stationary phases demonstrate high column efficiencies, wide operating temperature ranges, good thermal stability and excellent selectivity for aromatic isomers, especially phenol compounds. Their inclusion properties are also discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 36
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Pyrolysis GC ; Residual polystyrene ; Streptomycin ; Vitamin B1
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Residual synthetic adsorbent, cross-linked polystyrene, used in drug purification has been analyzed quantitatively by Curie-point pyrolysis gas chromatography. The peaks of intact polystyrene adsorbent in the pyrogram were used as key peaks for quantitative measurement of residues of the adsorbent in vitamin B1 and streptomycin sulfate. It was shown that them-ethylstyrene orp-ethylstyrene peaks in the pyrolyzates were suitable for determination of polystyrene adsorbent content. The levels of residual adsorbent in the drugs were found to be 〈0.1 %, the value stipulated by the International Conference on Harmonization (ICH). In quantitative evaluation of an adsorbent content of 0.1 % the precision was 3.6 % and 2.7 % for vitamin B1 and streptomycin sulfate, respectively.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 37
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Cholesterol oxides ; Cholesterol oxidation products (COPs) ; Meat products
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method of extraction, purification and gas chromatographic analysis of five cholesterol oxidation products (COPs) (7β-hydroxycholesterol, 5α, 6α-epoxycholesterol, 25-hydroxycholesterol, 7-ketocholesterol and cholestane-3β, 5α, 6β-triol) has been developed. The method is aimed at the determination of COPs in meat and meat products, in particular dry sausages, where large differences in the content of cholesterol and its oxidation derivatives may occur. Linearity of response of trimethylsilyl ethers was defined. The minimum concentration tested was 2.5 μg g−1 in the injected solution. The main feature of the present work is the addition of a purification step of unsaponifiables by SPE on silica cartridges. Extraction recoveries of COP standard mixtures, performed with or without the SPE step, are evaluated. The introduction of the clean-up step results in high purity samples without further losses in the entire process.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 38
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Column liquid chromatography ; Solid-phase microextraction ; Local anaesthetic lidocaine ; Optimisation of extraction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Solid-phase microextraction (SPME) has been combined with gas chromatography (GC) and liquid chromatography (LC) for the determination of lidocaine in human urine. A polydimethylsiloxane (PDMS) coated fibre was directly immersed into buffered urine. Extraction conditions such as time, pH, ionic strength, temperature, and agitation were optimised. The extracted lidocaine was thermally desorbed in a split/splitless injector for analysis with a GC-FID system or desorbed with liquid in a specially designed SPME-LC interface for analysis with an LC-UV system. After optimisation the method developed was evaluated and validated. Extraction yields of 22% were obtained in about 45 min. The reproducibility of the method is 〈5% (relative standard deviation). For five-times diluted urine, linear ranges were found from 5–1000 and 25–1000 ng·mL−1 for SPME-GC and SPME-LC, with detection limits of 5 ng·mL−1 for SPME-GC and 25 ng·mL−1 for SPME-LC. SPME can be used as a simple sample pretreatment method for the determination of lidocaine in urine by GC and LC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 39
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Solid-phase extraction ; Graphitized carbon black ; Volatile organic compounds ; Workplace air
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A fast, simple, and reliable method is presented for the determination of atmospheric semi-volatile organic pollutants at μg m−3 levels. The method has been used to monitor potentially carcinogenic toxic compounds to which workers are exposed in workplaces, and to measure the same compounds in outdoor air.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 685-688 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Headspace sampling ; Safrole ; Asarum species
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The development of a headspace GC method (HS-GC) to determine the safrole content in differentAsarum species from China and Europe, using eugenol as internal standard, is presented in this paper. The best results could be achieved by thermostating the samples at 100°C for 30.0 min, adding 10 μL of water to each sample. Optimum pressurisation and injection time showed to be 3.0 min and 12 s, respectively. GC separation was performed on an SE-54 column. The HS-GC results for safrole were in good agreement with those obtained by direct GC analysis of the dichloromethane (DCM) plant extracts. The investigated Asarum samples showed great deviations concerning the safrole content even within the sameAsarum species, e.g.Asarum himalaicum from Sichuan contained 0.0051% of this compound, the same species from the province of Hebei 0.53%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 724-726 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Phthalate esters ; PVC ; Plastic toys
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method for the analysis of 10 phthalate esters in plastic toys is described. The samples are soxhlet extracted in dichloromethane and phthalate esters in the extract are analysed by GC. Detection limits of dimethyl phthalate, diethyl phthalate, dibutyl phthalate, bis(2-ethylhexyl) phthalate, di-n-octyl phathalate, di-n-nonyl phthalate, benzyl butyl phthalate and benzyl octyl phthalate were approximately 5 ppm. The detection limits of diisononyl phthalate and diisodecyl phthalate, which are mixtures of several isomers, were approximately 200ppm. Analysis of 17 plastic toys revealed that only PVC-toys contained phthalate esters. Bis(2-ethylhexyl) phthalate, diisononyl phthalate and diisodecyl phthalate in concentrations up to 40% were present in the PVC-toys.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 42
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Solid-phase microextraction ; Headspace sampling ; Cyanide in blood
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Cyanide can be extracted from whole blood samples by headspace solid-phase microextraction (SPME) with a Carbowax/divinylbenzene-coated fiber. During heating a vial of a whole blood sample containing cyanide and acetonitrile as internal standard (IS) at 50°C in the presence of Na2SO4, a Carbowax/divinylbenzene-coated SPME fiber was exposed in the headspace of the vial for 45 min to allow adsorption of cyanide and IS. The fiber needle was then injected into a capillary gas chromatography (GC) instrument equipped with nitrogen-phosphorus detection. The headspace SPME-GC with a Supel-Q PLOT fused silica capillary column gave large peaks for cyanide and IS; almost no interfering peaks appeared. Recoveries of cyanide dnd IS from human whole blood were 3.02–4.06% and 0.21%, respectively. The calibration curve for cyanide added to human blood showed excellent linearity in the range of 0.04–4.0 μg mL−1; the detection limit was about 0.02 μg mL−1. The coefficients of intra-day and inter-day variation were not greater than 7.1 and 9.2%. Good correlation (r 2=0.999) was found between the present SPME-GC method and the conventional microdiffusion colorimetric method. Data on determination of cyanide in rat blood after intraperitoneal administration are also presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 43
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Mixed stationary phases ; Dibenzo-18-crown-6 ether ; MPBHpB ; Synergistic effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The synergistic effect is investigated in mixed gas chromatographic stationary phases containing dibenzo-18-crown-6 +MPBHpB [o-methyl-p-phenylene-bis-(p-heptoxy benzoate)], [o-methyl-p-phenylene-bis-(p-heptoxy benzoate)], with benzene/cyclohexane, cyclokexanes, phenols, alcohols and aniline derivatives as sample compounds pairs. Some of the separations reveal positive or negative synergistic effect. This effect depends on the temperature, the mixing ratio and the linear velocity of the carrier gas.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 44
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Organochlorine and organophosphorus pesticides ; Herbal medicine ; Essential oils ; Sulfuric acid treatment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A rapid and new clean-up method utilizing sulfuric acid treatment is demonstrated to identify and quantify the level of organochlorine (OC) and organophosphorus (OP) pesticide residue concentrations in herbal essential oils by gas chromatography (GC). Essential oils fortified with pesticides, that are extracted from herbs by steam distillation are partitioned with 65% acetonitrile/water(v/v) and treated with sulfuric acid at different reaction times and sulfuric acid concentrations. Optimal conditions, to avoid interference from essential oils in gas chromatographic analysis, is 17% (v/v) of a mixed phase ratio of sulfuric acid to organic solvent (hexane/ethyl ether=9∶1, v/v) and a reaction time of 30s. The response of the flame ionization detector (FID) is linear for all pesticides determined. Recovery of pesticides from fortified herbs studied are in the range of 75% to 111% (RSD, 4% to 11%) for OC, and 72% to 116% (RSD, 2% to 11%) for OP. Although sulfuric acid treatment destroys carbamate and some organophosphorus pesticides, this method has efficiently reduced matrix interference and provides a rapid, economical clean-up method with excellent linear data having low coefficients of variation for the GC analyses of BHC isomers, DDD, DDE, DDT, chlorothalonil, chloropyrifos, tetradifon, fenitrothion, malathion, and parathion in matrices of herbal essential oils.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 45
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Gas chromatography ; Enantiomeric separation ; Chiral derivatization ; Unusual secondary aromatic amino acids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary High-performance liquid chromatographic and gas chromatographic methods were developed for the separation of unusual secondary aromatic amino acids. Amino acids containing 1,2,3,4-tetrahydroisoquinoline, 1,2,3,4-tetrahydronorharmane-1-carboxylic acid and 1,2,3,4-tetrahydro-3-carboxy-2-carboline moieties were synthetized in racemic or chiral forms. The high-performance liquid chromatography was carried out either on a teicoplanin-containing chiral stationary phase or on an achiral C18 column. In the latter case the diastereomers of the amino acids formed by precolumn derivatization with the chiral reagents 2,3,4,6-tetra-O-acetyl-β-D-glucopyranosyl isothiocyanate or 1-fluoro-2,4-dinitrophenyl-5-L-alanine amide were separated. The gas chromatographic analyses were based on separation on a Chirasil-L-Val column.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 86-88 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Solid phase extraction ; Methoxime-silyl derivate ; Urinary steroids ; Women with effluvium
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Urinary steroid metabolites were measured by capillary gas chromatography in 25 women (aged 33.3±12.0 years) with effluvium and 16 control healthy laboratory workers women (aged 34.6±8.4 years). There was significant elevation in the level of a number of steroids and steroid metabolites. The elevation of most steroid metabolites refers to the increased steroid secretion of the adrenal and the high cortisol metabolites levels may be do to stress in some of the patients with effluvium.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 163-165 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Solid-phase extraction ; Urinary steroids ; Terbutaline treatment ; Asthmatic children
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Steroid metabolites have been measured by capillary gas chromatography in the urine of 38 children aged 3–6 years. The children comprised three groups: those with asthma being treated with Terbutaline (13), children with asthma but not undergoing treatment (17), and control children in hospital but free from endocrine diseases (8). There were significant (P〈0.05) differences between the amounts of steroids excreted by the different groups of children. Terbutaline therapy led to elevated levels of tetrahydrocortisone, androstenediol, 11-ketopregnanetriol and a reduced ratio of androgen to cortisol metabolites compared with those for untreated asthmatic children. We assume that Terbutaline does not have a steroid-like mechanism of action but acts by modification of the activity of several adrenocortical enzymes. We suggest a hypothesis whereby the antiasthmatic effect of Terbutaline could not only be a connected with its well-known mechanism of action, but it might be explained as a result of the modification of the production of certain glucocorticoids and androgen hormones.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 728-738 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Stationary phases ; Prototypical phases ; Retention model ; Retention value ; Dipolarity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Stationary phases are characterised in a multilinear retention model by retention data of a set of selected prototypical substances. Prototypical stationary phases confirm the application of prototypical substances in the retention model. For comparison, 27 stationary phases are characterized with solute descriptors of the solvation model. New adjusted substance factors are calculated for 33 selected compounds for a new characterization of GC stationary phases in the extended retention model with retention values, calculated from retention indices and b-values of the n-alkane equation. Substance dipolarityD N-factors are separated from πN, the adjusted dipolarity-polarisability. New substance factors give satisfying correlation results and new explanatory factors as phase descriptors for 27 stationary phases.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 758-762 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Butyric acid ; Milk fat content ; Mixed fats
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Quantitation of the milk fat content in mixed fats is of interest in food analysis. It can be achieved by calculation from the butyric acid (C4) content in the mixed fat and a mean C4 content for pure milk fats. Alternatively, instead of applying a C4 mean value, the C4 content in the actual milk fat can be used if this reference sample is available. A recently improved analytical method based on gas chromatography of butyric acid methyl ester using an internal standard has been applied to determine the milk fat content in mixtures with beef tallow, lard, soybean oil, olive oil, sunflower oil, palm kernel oil and palm oil ranging from 1 to 90% milk fat content. Within the whole range of mixtures, mean absolute deviations between the determined and the actual milk fat content were below 0.5% and the maximum absolute deviation was not more than 1.0% when using the reference sample. The overall mean absolute deviation was 0.04% for milk fat contents of 1 to 10% and 0.28% for milk fat contents of 10 to 90%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 50
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Solid phase extraction ; Brazilian sugar cane spirit ; Lower fatty acids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A gas chromatographic method for the analysis of seventeen acids in a water/ethanol matrix is described. The diluted samples were first concentrated by solid phase extraction. Nonanoic acid was the internal standard. A good separation profile was obtained for all compounds, including the isomers: n and iso-butyric acids, n and isovaleric acids and n and iso-caproic acids. The method is fast, sensitive (20–30 μg L−1) and has a good reproducibility (4–7 %). The recovery was in the range of 94%–116% for the medium chain acids (C7-C16). This method allowed the identification of fourteen acids in caninhas and other spirits. The total acid content and the profile of the exportation type caninhas are similar to the ones obtained for several international beverages.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 51
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Metal complexes ; Chemically bonded phases ; Thermodynamic parameters ; Specific interactions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Results are presented of studies of packings containing copper (II) acetylacetonate (acac), hexafluoroacetylacetonate (hfac), and chloride, chemically bonded via β-dik-etonate groups. The retention parameters retention factor (k) specific retention volume (V g), and molecular retention index (M e) were measured and used to calculate the thermodynamic parameters free energy of adsorption (ΔG a) heat of adsorption (−ΔH a), and entropy of adsorption (ΔS a). These parameters enable, characterization of specific interactions between aromatic and cyclic hydrocarbons, ethers and thioethers and metal complexes chemically bonded, to a silica surface.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 52
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Atomic emission and MS detection ; Solid-phase extraction ; Aqueous samples
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A procedure is described for the (non-target) screening of hetero-atom-containing compounds in tap and waste water by correlating data obtained by gas chromatography (GC) using atomic emission (AED) and mass selective (MS) detection. Solid-phase extraction (SPE) was coupled on-line to both GC systems to enable the determination of microcontaminants at the 0.02–1 μg L−1 level in 7–50 mL of aqueous sample. The screening was limited to compounds present in at least one heteroatom-selective GC-AED trace above a predetermined concentration level. These compounds were identified by their partial formulae (AED) and the corresponding mass spectra, which were obtained from the GC-MS chromatogram via the retention index concept. The potential of the approach was demonstrated by the identification of target compounds as well as all unknowns present in tap and waste water above the predetermined threshold of 0.05 μg L−1 (tap water) or 0.5 μg L−1 (waste water).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 53
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Solid-phase extraction ; Rapeseed oil ; Sterols
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A capillary gas chromatographic method is described for the determination of major plant sterols and cholesterol in edible oils and fats. In the sample preparation procedure reversed-phase, solid-phase extraction with C18 adsorbent was used to extract the unsaponifiable matter and for sample cleanup after saponification. Sterols were quantitated as their trimethylsilylether derivatives using an internal standard method (betulin). The method was validated by recovery tests and analysis of two reference materials representing vegetable oil mixture and milk fat matrices. Average recoveries of spiked cholesterol and cholesterol acetate in rapeseed oil were 103±4% (n=12) and 101±3% (n=10), respectively. The sterol values determined in the reference materials were found to be in a good agreement with their given certified or indicative values. Applied to edible oils and fats, plant sterols and cholesterol at levels〉20 mg kg−1 could be accuratively quantitated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 817-822 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Crown ether capped cyclodextrin ; Chiral separations ; Isomer separations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The solution of a new synthesized compound, mono-6-(1'-benzo-aza-15-crown-5)-2, 3, 6- permethyl-β-cyclodextrin, in the moderately polar polysiloxane OV-1701 was coated onto fused silica capillary column. The chromatographic characteristics including column efficiency, polarity and selectivity were studied. Excellent selectivity for the separation of enantiomers and positional isomers was obtained. The results show that the combined effect between the special caves of β-cyclodextrin and crown ether plays a significant role in the separation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 55
    ISSN: 1612-1112
    Keywords: Gas chromatography ; UV-Vis detection ; Gas phase absorption spectrometry ; Alcohols
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This article describes a theoretical/practical study of the parameters which affect the chromatograms obtained when using a molecular diode-array spectrometer as the detector in gas chromatography. The objective is to offer some rules which permit the identification of the optimum signal/noise relation. To achieve this, we study the effect of the different parameters which affect the noise and how to reduce their impact, as well as alternatives for increasing the signal. All the options tested can be applied by correctly programming the spectrometer with BASIC programs, within reach of any use who has even a small understanding of programming. Finally, we consider the effect that the selection of the acquisition conditions may have on the chromatographic resolution. All the studies are carried out using a mixture of alcohols and phenols.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 56
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Liquid crystal stationary phase ; Packed columns
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The separation ofm-, p-, o- xylenes andm-, p- ethyltoluenes was studied on a packed column with 2,5% of 4-[(4-chlorobenzyl)oxy]-4′-cyanoazobenzene (CBOCA) on Chromosorb W HP 100–120 mesh. The synthesis and study of the mesomorphic behaviour of CBOCA are presented. Temperature range for the separation ofm-, p-, o- xylenes (in this order of elution) is 125–85°C, at cooling. The best separation was achieved at about 90°C. The separation temperature domain ofm-ethyltoluene fromp- ethyltoluene is 160–85°C.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 131-131 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: No Abstract
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 123-130 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: This paper presents the electrode separation method for the boundary condition of a-Si TFT mixed-level simulation. The Poisson equation and the continuity equation are formulated into equivalent circuits. So, a circuit simulator can be used to handle the two-dimensional numerical simulation of a-Si TFT. The boundary condition problem between a semiconductor and an external circuit is solved by the electrode separation method. An electrode is separated into two nodes to fit Kirchhoff's current law and the semiconductor equations, respectively. A simple a-Si TFT/LCD circuit is taken as an example for the electrode separation method. For mixed-level simulation this technique is very useful. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 133-151 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: Most traditional theories of speech production are currently based on plane waves. However, it is well known that, for acoustic waveguides, higher acoustical modes start to propagate and can become predominant above cut-on frequencies. This paper thus presents the transmission line matrix method, a numerical method initially designed for electromagnetic waves, and its adaptation to acoustic waveguides. The method, and in particular the representation of boundary conditions, is validated by comparison with known analytical theories. It is then used to show the dramatic effect of higher order modes upon the radiation characteristics of uniform ducts, as well as the importance of source location. Finally, first applications to bent and bifurcating rectangular ducts are presented, and the transfer function of a vowel [a] is shown to display frequency patterns typical of those measured on human subjects and that cannot be explained by one-dimensional propagation only. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 20 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 189-205 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: The atomic mixing model that forms the basis of the IMPETUS software is described in detail. The model simulates the mixing and particle emission that occurs when a solid is bombarded with energetic particles, such as in SIMS or SNMS. The methods employed for computing the deposition of the bombarding particles and their energies along with the modelling of the particle yield and the surface recession speed are described.The material volume concentrations are governed by a set of partial differential equations. A description of the finite element method that is employed for their solution is given. Results from the application of IMPETUS II to a number of typical structures are given. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 3-19 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: This paper presents an efficient space domain integral formulation of planar dielectric structures based on the concepts of multiresolution analysis (MRA) theory. Battle-Lemarie multiresolution expansions are utilized in the moment method solution of a volume integral equation for the unknown electric field. The generation of sparse moment matrices is explained in view of the cancellation property of wavelet basis functions. The formulation is then applied to two- and three-dimensional dielectric structures including waveguides and resonators, and the numerical results and consequences of matrix sparsity are discussed in detail. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 21-40 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: An efficient wavelet-packet-based time-frequency technique is proposed in this paper. This technique has found applications in inverse synthetic aperture radar (ISAR). It combines the Wigner-Ville distribution (WVD) of each sub-band signal partitioned from an input signal by the wavelet-packet transform (WPT). These distributions are used to estimate the parameters in Doppler processing. Similar parametric compensation is carried out in range processing so that a specific scatterer is focused in both range and cross-range. The end result uses the Fourier imaging method to obtain a high-resolution radar image. This technique is primarily based on estimation and compensation of the Doppler scattering parameters of the dominant scatterers for improved focus. It can be of great value to the scattering-oriented ISAR imaging. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 273-274 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: No Abstract
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 255-257 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: We re-examine the potential drop method to give a direct estimation of the absolute error in transmission-line matrix (TLM) diffusion modelling. In particular, the open-circuit boundary is taken into account. Promising results are presented with a structure relevant to thermal analysis of semiconductor devices. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 259-271 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: There is a class of material processing simulators which require solution of the diffusion equation over a surface which is evolving due to some physical or chemical process related to the concentration of the diffusing species. Because of its explicit and unconditionally stable nature, the transmission line matrix (TLM) method is well suited to efficiently solve the diffusion equation in these instances. However, the methodology for using TLM on a dynamic problem space is not well established.This paper describes the development of algorithms to handle the insertion, deletion and motion of TLM nodes along the one-dimensional surface of a two-dimensional thin film process simulator called GROFILMS. These routines are completely compatible with concurrent time scaling to increase computational efficiency. Central to this development is the use of an asymmetric TLM cell which provides more flexibility for representation and minimizes the disturbance effects of these nodal operations. The scaling routines apply conservation of charge and continuity of current into the affected region to recompute the scattered or the incident pulses as a result of the evolving network. Verification of these results through comparison with known analytic solutions is achieved where possible. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 41-54 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: The local support and vanishing moment property of wavelet bases have been recently used to obtain a sparse matrix representation of integral equations in the spatial domain. In this paper, an application of the cubic spline and the corresponding semi-orthogonal wavelets in the spectral domain is proposed for the evaluation of the reflection coefficient for open/short transmission lines. Because of the nearly optimal time (space)-frequency (wavenumber)-window product of the cubic spline and wavelet, the double spectral integrals appearing in the formulation can be computed more efficiently than with the commonly used piecewise sinusoidal (PWS) or triangular basis functions. It is shown that the time-frequency-window product of the triangular and PWS function are close to each other, whereas those of the cubic spline/wavelet are close to 0·5, the lowest possible value corresponding to functions of Gaussian class. Both the PWS and wavelet bases are applied to microstrip and coplanar waveguides with isotropic and anisotropic substrates, and the results are compared with published theoretical and experimental data. It is observed that even though the number of splines/wavelets required for an accurate representation of the current distribution in the transmission line is almost twice as high as the number of PWS functions, the overall computation time decreases significantly in the former case. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 69-84 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: The use of wavelet expansions in numerical solutions of electromagnetic frequency-domain integral equation formulations is steadily growing. In this paper we review the recently suggested impedance matrix compression (IMC) method for a more effective integration of wavelet-based transforms into existing numerical solvers. The difference between the IMC method and the previous approaches to applying wavelets in computational electromagnetics is twofold. Firstly, the transformation is effected by means of a digital filtering approach. This approach renders the transform algorithm adaptive and facilitates the derivation of a basis which best suits the problem at hand. Secondly, the conventional thresholding procedure applied to the impedance matrix is substituted for by a compression process in which only the significant terms in the expansion of the (yet-unknown) current are retained and hence a substantially smaller number of coefficients has to be determined. A few numerical results are included to demonstrate the advantages of the presented method over the currently used ones. The feasibility of ensuring a slow growth in the number of unknowns even when there is a rapid increase in the problem complexity is shown by an illustrative example. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 87-103 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: An efficient novel algorithm is introduced for ground wave propagation problems. First, ground wave propagation characteristics for a vertically polarized short electric dipole over a smooth spherical earth are reviewed, reducing the vector electromagnetic problem for the three-dimensional spherical geometry to an equivalent two-dimensional rectilinear scalar potential problem which is solved by spectral analysis and synthesis. Alternative evaluations of the spectral integral yield ray optical and normal mode solutions, which are conventionally referred to as the Norton and Wait formulations, respectively. Combining these formulations in an efficient manner yields a hybrid algorithm which is constructed so as to account adaptively for the characteristics of ground wave propagation in interference, intermediate and diffraction regions (including mixed paths) for various source and/or receiver heights. Numerical comparisons are made with reference results obtained via the parabolic equation (PE) method, in parametric ranges where PE is reliable; this permits assessment of the effectiveness of the hybrid approach. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 183-184 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: No Abstract
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 153-166 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: Most methods for the numerical calculation of inverse Laplace transformations f(t) = L-1[F(s)] have serious limitations concerning the class of functions F(s) that can be inverted or the achievable accuracy. The procedures described in the paper can be used to invert rational as well as irrational or transcendental functions of the complex variable s. The required accuracy of the results can be enhanced without changing the algorithm, only at the cost of a longer computation time. The described methods were verified with many examples including transients in lumped/distributed systems with sections of lossy multiconductor transmission lines or with distributed RC elements. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 71
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: No abstract
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 167-181 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: In this study, a software package is described which has been developed for the simulation of detection and tracking in surface wave high frequency (SW-HF) radars. The aim is to investigate the problems related to detection and tracking of surface targets at beyond the horizon ranges. In SW-HF radars target detection and tracking involves stochastic features such as target RCS fluctuations, atmospheric, galactic and/or man-made ambient interference components, and the sea clutter with the dominant resonant Bragg returns which affect target detection are all incorporated in the package. In the model, first, terrain data are fed into the simulator by means of a specially designed graphical user interface. Then, a scenario is prepared where the radar's location, coverage and operational parameters can be defined, together with different targets and their sailing routes. The radial propagation paths for angular resolution cells are extracted from the terrain data with the lengths of (possible) sea-island transitions. The surface wave path losses are calculated over the smooth spherical earth's surface with finite conductivity. Surface roughness and mixed-path propagation effects are also included in these calculations. The target detection is performed in the frequency domain after calculation of the noise floor, signal to noise (SNR) and clutter to noise (CNR) ratios. Since SW-HF radars yield coarse range and azimuth but accurate velocity measurements, different Kalman filter techniques are applied for the target tracking, and algorithms are added to improve the track-measurement data correlation. Various simulation tests are performed and the results are presented. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 187-187 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: No abstract
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 277-287 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: The solution of Maxwell's equations is considered using the finite difference time domain (FDTD) method and the client-server software paradigm on a heterogeneous network of distributed computers. The performance of compilers is evaluated and the PVM 3.3 message-passing harness, in both its conventional and TCP mode of operation, is compared with direct calls to the lesser known TCP/IP routines on the operating system. An example is given showing the impact of using different floating-point representations, in each subdomain, when computing field updates. As far as we are aware to date, there has been no discussion of the actual content of the communication between concurrent FDTD processes; accordingly we have defined one such protocol. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 307-316 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: This paper presents an FE modelling approach for the calculation of transient eddy currents in thin conductive layers, where the complexity of the geometry prohibits both a detailed FE modelling and the use of analytical tools. The method allows an estimation of the maximum values of eddy currents at a highly reduced modelling effort and the use of a commercial FE software package. A prerequisite is a slowly varying magnetic field that can be assumed to be unaffected by the eddy currents. It is shown that neither the source of the magnetic field nor the insulating environment has to be modelled. The model is built up exclusively from 2D elements and is excited via the magnetic vector potential. The spatial distribution of the latter is calculated separately in a magnetostatic calculation based on Biot-Savart's law. It is then applied in time-varying form as a dynamic boundary condition at every node of the model. The method was applied to a simple problem for which the results of a detailed FE calculation were available, to document its validity. Further numerical results are presented for the plasma vessel and the heat radiation shield of the Wendelstein 7-X fusion experiment in the case of an emergency discharge. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 55-68 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: Multiresolution time domain (MRTD) analysis is applied directly to Maxwell's equations to model inhomogeneous dielectric material. In our approach, scaling and wavelet functions are used as a complete basis for the method of moments. The MRTD scheme is used to analyze different types of resonant cavity structures with varying dielectric perturbations in one, two and three dimensions. The results presented here agree very well with those obtained by FDTD, FEM and integral equation methods. MRTD allows for considerable savings in memory and computation time in comparison to FDTD, while maintaining the same accuracy of the results. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 1-1 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: No Abstract
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 105-121 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: This paper describes a computationally efficient diakoptic algorithm for the solution of closed-mesh electrical network equations. The algorithm is designed for use with time-varying and/or discontinuous equations describing limited size power supply systems, allowing them to be torn into smaller subdivisions in a manner that is independent of their structure. The efficiency of the algorithm is demonstrated by comparing its performance with that obtained when using a more conventional sparse matrix technique, on the basis of the number of floating point operations required for the solution of a range of typical network problems. Mention is made of the parallel processes inherent in the resultant equation structure. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 207-219 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: The IMPETUS II code simulates the atomic mixing and particle emission that occurs when a solid is bombarded by energetic particles (as in SIMS or SNMS). The underlying model consists of a system of partial differential equations that are solved by a finite difference method (FDM). Special techniques are also employed to model thin layers and sharp interfaces, to deal efficiently with wide homogeneous layers (when the solution is tending to a steady state), to model linear diffusion in order to smooth the sharp interfaces before they enter to domain of the FDM.In this paper the special techniques are described in detail. Results from test problems, demonstrating these techniques, are shown. An algorithm that describes the way the IMPETUS II code is structured is given. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 221-229 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: This paper presents a physical-mathematical model for abrupt heterojunction transistors and its solution using numerical methods with application to InP/InGaAs HBTs. The physical model is based on the combination of the drift-diffusion transport model in the bulk with thermionic emission and tunnelling transmission through the emitter-base interface. Fermi-Dirac statistics and bandgap narrowing distribution between the valence and conduction bands are considered in the model. A compact formulation is used that makes it easy to take into account other effects such as the non-parabolic nature of the bands or the presence of various subbands in the conduction process. The simulator has been implemented for distributed memory multicomputers, making use of the MPI message-passing standard library. In order to accelerate the solution process of the linear system, iterative methods with parallel incomplete factorization-based preconditioners have been used. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 273-273 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: No Abstract
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 82
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 233-242 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: The propagation factors of buried microstrip lines are considered. The associated eigenvalue problems are solved by the edge-based vectorial finite element method (VFEM). To improve the higher-order VFEM solutions, the problem infinite domain is truncated by second-order absorbing boundary conditions (ABCs). This reduces the number of unknowns and, consequently, the numerical effort. Owing to the many advantages of both the edge-based VFEM and the second-order ABCs, this full-wave method is implemented by a general computer program for solving unbounded domain problems involving complex geometries and inhomogeneous media. The examples presented show the validity of this technique. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 243-254 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: Various local absorbing boundary conditions are implemented in the TLM method and their corresponding reflections are compared as a waveguide termination. The instability in different ABCs is discussed and reflections from the terminating walls are computed. An improvement for the matched termination wall is proposed and reflection of this absorbing condition is compared with ordinary matched termination. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 317-318 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: No Abstract
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 289-298 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: Oscillatory flow present in the melt during InSb single crystal growth using an RF-heating Czochralski method has been numerically investigated by means of the finite difference method using the HSMAC algorithm. The thermal boundary conditions required for the numerical simulation model were obtained experimentally by measuring the temperature profile along the crucible of a Czochralski system by means of thermocouples mounted in the crucible. Results of numerical simulations showed that the use of a third-order upwind discretization scheme was necessary to catch the oscillatory behaviour of the fluid flow in the melt. It was shown that this oscillatory behaviour strongly depends on the crystal rotation rate. Indeed, the oscillation period increases when the crystal rotation rate is above a critical rotation rate. In order to avoid such oscillations, crystal rotation rates lower than this critical value of crystal rotation rate must be selected for the growth of high quality crystals free of striations. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 11 (1998), S. 299-306 
    ISSN: 0894-3370
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: The application of the FDTD algorithm on generalized non-orthogonal meshes, following the basic ideas of Holland (1983), has been investigated by many authors for several years now, and detailed dispersion analysis as well as convergence studies have been published. Already in 1992 also a general stability criterion was given for the time integration using the standard leap-frog scheme (Lee et al.). Many authors, however, still propose some damped time stepping algorithms to work around unexpected instabilities in the discretization method. In this paper the origin of this type of instability is revealed, and a technique to obtain a stable discretization of Maxwell's equations on non-orthogonal grids is proposed. To obtain more insight into the stability properties of the method, it is reformulated according to the matrix-vector notation of the Finite Integration Technique. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 21 (1998), S. 25-42 
    ISSN: 0170-4214
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: Considered is the rotation of a robot arm or rod in a horizontal plane about an axis through the arm's fixed end and driven by a motor whose torque is controlled. The model was derived and investigated computationally by Sakawa and co-authors in [7] for the case that the arm is described as a homogeneous Euler beam. The resulting equation of motion is a partial differential equation of the type of a wave equation which is linear with respect to the state, if the control is fixed, and non-linear with respect to the control.Considered is the problem of steering the beam, within a given time interval, from the position of rest for the angle zero into the position of rest under a certain given angle.At first we show that, for every L2-control, there is exactly one (weak) solution of the initial boundary value problem which describes the vibrating system without the end condition.Then we show that the problem of controllability is equivalent to a non-linear moment problem. This, however, is not exactly solvable. Therefore, an iteration method is developed which leads to an approximate solution of sufficient accuracy in two steps. This method is numerically implemented and demonstrated by an example. © 1998 by B. G. Teubner Stuttgart-John Wiley & Sons Ltd.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 21 (1998), S. 59-91 
    ISSN: 0170-4214
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: A time-dependent Ginzburg-Landau-type model of a superconducting-normal-superconducting junction is presented. The existence and the uniqueness of the solutions are proved. When the data of the model are symmetric of some kinds, the solutions turns out to be symmetric of some kinds. In this symmetric case, an approximate model with the small thickness of the normal material in the middle of the junction as coefficients of a differential system is established for the sake of numerical computations. And also the existence and the uniqueness of the solution to this approximate model are set up. © 1998 by B. G. Teubner Stuttgart-John Wiley & Sons Ltd.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 21 (1998), S. 165-185 
    ISSN: 0170-4214
    Keywords: boundary integral equations ; boundary finite element ; free edge polygonal plate ; hypersingular kernels ; Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: We consider the problem of a polygonal plate with free edges. It is a boundary value problem for the biharmonic operator on a polygon with Neumann boundary conditions. Its resolution is studied via boundary integral equations. A variational formulation of the boundary problem obtained by a double-layer potential is given. Finally, we implement the method and give numerical results. © 1998 B. G. Teubner Stuttgart-John Wiley & Sons Ltd.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 21 (1998), S. 227-249 
    ISSN: 0170-4214
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: Integral equations associated with the basic boundary value problems for the Laplace and Stokes equations are considered. The integral operators for these integral equations are interpreted as the pseudodifferential operators, and their principal symbols are calculated. The symbols are obtained in terms of the principal curvatures and the coefficients of the first quadratic form of the boundary. As a consequence, the initial approximation is suggested for the iterative methods solving the integral equations. © 1998 by B. G. Teubner Stuttgart-John Wiley & Sons Ltd.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 21 (1998), S. 375-392 
    ISSN: 0170-4214
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: In this work we analyse a model for radiative heat transfer in materials that are conductive, grey and semitransparent. Such materials are for example glass, silicon, water and several gases. The most important feature of the model is the non-local interaction due to exchange of radiation. This, together with non-linearity arising from the well-known Stefan-Boltzmann law, makes the resulting heat equation non-monotone. By analysing the terms related to heat radiation we prove that the operator defining the problem is pseudomonotone. Hence, we can prove the existence of weak solution in the cases where coercivity can be obtained. In the general case, we prove the solvability of the system using the technique of sub and supersolutions. © 1998 B. G. Teubner Stuttgart-John Wiley & Sons Ltd.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 21 (1998), S. 463-477 
    ISSN: 0170-4214
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: We consider the time-harmonic Maxwell equations in the high-frequency case for a heterogeneous medium, i.e., a medium which is composed by a conductor and a perfect insulator, or, in other words, a loaded cavity. As a consequence of a suitable compactness result, we prove that Fredholm alternative holds for such a problem. Since the kernels of the considered operator and of its adjoint are proven to be trivial, a unique solution exists for each given datum. © 1998 B. G. Teubner Stuttgart-John Wiley & Sons Ltd.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 21 (1998), S. 501-517 
    ISSN: 0170-4214
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: In this paper an initial-boundary-value problem in one-space dimension is studied for the Broadwell model extended to a gas mixture undergoing bimolecular reactions. Techniques of semigroup of bounded positive operators in a suitable Banach space are used to prove existence and uniqueness of the solution on bounded time intervals whose length depends on the initial data. © 1998 B. G. Teubner Stuttgart-John Wiley & Sons Ltd.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 21 (1998), S. 589-603 
    ISSN: 0170-4214
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: In the paper we study the problem of control by means of a heat source g for a thermoelastic system of equationsutt - ρ∇·p(θ, ∇u) - νΔut + DΔ2 u = f, cv(θ, ∇u)θt - κΔθ - ρθ[pθ (θ, ∇u)·∇ut] - ν∣∇ut∣2 = g, in a two-dimensional domain, where both viscosity ν and rigidity D are positive. Such a system has been considered in our former papers, and existence of solutions as well as uniqueness have been obtained. Here we prove the continuity and differentiability of solutions under somewhat stronger assumptions. An example of a control problem and necessary optimality conditions are presented. The system has an interpretation as a plate reinforced with shape memory alloy (SMA) wire mesh. © 1998 B. G. Teubner Stuttgart-John Wiley & Sons Ltd.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 21 (1998), S. 619-651 
    ISSN: 0170-4214
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: We consider acoustic scattering from an obstacle inside an inhomogeneous structure. We prove in the paper that if the outside inhomogeneity is known then the obstacle and possible inside inhomogeneity are uniquely determined by the fixed energy far field data. The proof is based on new mapping properties of layer potentials in spaces that specify one point. © 1998 B. G. Teubner Stuttgart-John Wiley & Sons Ltd.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 21 (1998), S. 685-700 
    ISSN: 0170-4214
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: In the present work, the problem of electromagnetic wave propagation in three-dimensional stratified media is studied. The method of decoupling the electric and magnetic fields is implemented, and the spectral approach is adopted, componentwise, to the vector equation involving the electric field. Operational calculus of self-adjoint, positive operators in suitable Hilbert spaces is used to solve the corresponding initial value problems. The spectral families of these operators for the cases of the whole space and of a finite layer are constructed. A discussion on the applicability of the obtained results to physical problems is also included. © 1998 B.G. Teubner Stuttgart-John Wiley & Sons Ltd.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 21 (1998), S. 757-780 
    ISSN: 0170-4214
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: In this paper we prove under the assumption of small initial data the global existence of a classical solution to the equations in viscoelasticity, associated with a free damping boundary condition. We also show that if we choose the initial data large enough, blow up will occur in finite time. © 1998 B. G. Teubner Stuttgart-John Wiley & Sons Ltd.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 21 (1998), S. 1115-1148 
    ISSN: 0170-4214
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: We apply the Child-Langmuir asymptotics of the Vlasov-Poisson system to the case of a bipolar diode, i.e. a vacuum diode where two species of particles of opposite electric charge are flowing. This leads to a simplified model which, if at least one of the two injected currents is not too large, has a unique solution. Moreover, in that case, the currents flowing inside the diode are limited by the so-called bipolar Child-Langmuir currents. In the case of large currents, other solutions may appear, and the formation of virtual electrodes may occur inside the diode. © 1998 B. G. Teubner Stuttgart - John Wiley & Sons, Ltd.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 21 (1998), S. 1149-1183 
    ISSN: 0170-4214
    Keywords: free boundary fluid motion ; Cauchy problem ; Hamilton structure ; Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: The Cauchy problem for the motion of a liquid drop under surface tension is solved locally in time on the basis of a general abstract existence theorem for Hamiltonian systems which seems to be of interest also in other areas. © 1998 B. G. Teubner Stuttgart - John Wiley & Sons, Ltd.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 21 (1998), S. 969-983 
    ISSN: 0170-4214
    Keywords: Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: We study the problem of the scattering by a periodic, inhomogeneous, penetrable medium. Using the Dirichlet-to-Neumann operator from the classical formulation of the problem we derive a variational equation and give regularity result to show the equivalence of both formulations. We present certain uniqueness results, which by the Fredholm alternative yield existence of the solution and its continuous dependence on the incoming wave. We prove existence of a solution for special incident waves even if there is no uniqueness. A result about analytical dependence of the solution on the wave number and the incident angle is given. © 1998 B. G. Teubner Stuttgart - John Wiley & Sons, Ltd.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...