Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 101
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 279-281 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, glass ; Packed column ; Retention data ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 102
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 328-332 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica (capillary) columns ; Bonded (cross-linked ) phases ; Hydrocarbon analysis ; Retention index data ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 103
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Automated analysis ; Solvent vapor ; Gas sampling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Solvent vapors in air may be measured with capillary gas chromatographic columns. By using large diameter columns and sample loops of approximately the same internal diameter, the column may be connected directly to the gas sampling valve. This approach eliminates the use of a splitter or cryogenic trapping and allows low levels to be measured. By operating the column at high velocity, column efficiency is sacrificed for increase in speed.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 104
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Residue analysis ; Fenvalerate ; Fabric protectant ; Woolen cloth ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for the determination of fenvalerate (cyano(3-phenoxyphenyl)methyl 4-chloro-α-(1-methylethyl)-benzeneacetate) residues on woolen cloth. The fenvalerate was Soxhlet-extracted from the treated fabric with acetone for four hours at a reflux rate of six solvent exchanges per hour. The fenvalerate residue was determined by gas-liquid chromatography with a flame ionization detector. The results were quantitated by comparing integrator counts obtained from extracts of treated samples with those obtained from known standards. The method was sensitive to 0.00054% fenvalerate by weight. Recoveries from fabric treated with 0.00054% to 0.215% averaged 94.8%. The response of the detector was linear over a 400-fold range of fenvalerate concentrations.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 105
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 232-235 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Inlets ; Solvent effect ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 106
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 390-391 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Dispersive interactions ; Inductive interactions ; Polycyclic aromatic hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 107
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 392-393 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Hydrogen carrier gas ; Pt-Ir tubing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 108
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 480-487 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Residue mixtures ; Inlet characteristics ; Injection procedure ; Repeatability ; Linearity ; Quantification ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Residue mixtures of pesticides in foods which were difficult to separate by packed-column gas chromatography were determined by capillary gas chromatography and electron capture detection. Manual injections of sample and reference standard were made with a 10 μL syringe on a septum-enclosed, split/ splitless inlet system. Optimal peak height repeatability (± 3%( was achieved with three-μL injections which were made within time periods of four hours or less. The average linearity coefficient (slope( obtained for detector response as a function of solution concentration was 1.1.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 109
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 504-507 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Effluent splitting ; Polyimide ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 110
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 510-511 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Optically active compounds ; Determination of trace amounts ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 111
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 507-509 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, glass ; GC/MS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 112
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 561-563 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary ; On-column injection ; Rotary valve ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 113
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 621-622 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Multiplex GC ; Vacancy chromatograms ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 114
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 623-624 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 115
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 684-685 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Post column trap ; Alumina ; Halocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 116
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 4-10 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Ion mobility detector ; Plasma chromatography ; Selective detection ; Quantitative analysis ; Halogenated compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An ion mobility detector that has been specifically developed for interfacing with capillary gas chromatography is investigated in the negative ion mode. Like the electron capture detector, to which this instrument is closely related, the ion mobility detector shows an enhanced response to low molecular weight halogenated compounds when a small quantity of oxygen is doped into the make-up gas flow. Under O2 doping conditions, the device can operate in a reactant ion monitoring mode responding universally to compounds capable of capturing thermal electrons and in a tunable selective product ion mode providing increased selectivity over that achieved by the ECD. At an oxygen concentration of 0.5%, minimum detectable amounts as low as 600 femtograms have been realized for carbon tetrachloride. Selectivity of chloro- versus bromo- compounds is demonstrated using a mixture of p-dichlorobenzene and p-dibromobenzene.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 117
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 34-35 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Samples with varying water content ; Retention times correlated with water content ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 118
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 213-215 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; HPLC sample work-up ; Valeriana celtica L ; Essential oil ; Nepetalactone, isovaleric acid ; Feline attractant ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 119
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 228-231 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Sample introduction ; Splitless injection ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 120
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Dynamic versus static leaching ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: It is well known that removal of metal ions from the glass surface greatly improves both the thermal stability and the adsorption characteristics of glass capillary columns. Usually metal ions are removed from a glass surface by acid leaching; in particular, the static leaching procedure with hydrochloric acid is used very often for the preparation of glass capillary columns. This paper discusses the results of an investigation into dynamic leaching. Special attention is paid to those factors which affect the adsorption properties of the leached surface. The importance of the non-specific adsorptivity of the capillary surface due to changes of surface properties induced by the leaching process is pointed out.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 121
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 317-319 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, fused silica ; Drug screening ; Fused silica capillary column ; Toxicology ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 122
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 319-321 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Supercritical fluid chromatography ; Small diameter capillary columns ; Static coating at elevated temperature ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 123
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 247-254 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Screening for basic drugs with retention indices differing by only four units ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary columns offer the toxicologist several advantages over packed columns. We have presented a highly reproducible screening procedure based on the retention index system and have shown the use of capillary columns for routine quantitation. We are currently expanding the use of these columns in our laboratory and predict that they will be in routine use by most toxicologists in the near future.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 124
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 422-426 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Stationary phase, polar ; DEGA ; Residue analysis of pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Polydiethylene glycol adipate (DEGA) has been successfully used as stationary phase for residue analysis by glass capillary gas chromatography. A specially stabilized version of the phase yields a good polar column which is stable up to 250°C when used in temperature programmed cycles. The paper lists 90 pesticides that have been successfully chromatographed in ng quantities on a DEGA column.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 125
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 436-440 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Superox-4 pretreatment, deactivation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 126
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 442-443 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Cyclodextrin polymer beads ; Double retention mechanism ; Interaction energy ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 127
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 444-445 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Open-tubular columns ; Reduced diameter ; High pressure ; Coating reservoir ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 128
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 448-450 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Solute focussing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 129
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 501-504 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Van Deemter curves ; Thick film columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 130
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 497-500 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, fused silica ; On-column injection ; Solvent polarity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 131
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 564-565 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Splitless injection ; Trace analysis ; EPA phenols ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 132
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 567-568 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Solvent effect ; Headspace analysis ; Trace analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 133
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 595-604 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; GC/MS ; Pyrolysis GC ; Pyrolysis MS ; Headspace sampling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Pyrolysis gas chromatography (P/GC) has been successful in differentiating coal tar pitches which are used in the manufacture of high temperature graphite materials [1,2]. In the present study, coal tar and petroleum pitches received from five suppliers were readily differentiated using three distinct methods of polymer analysis: dynamic headspace and pyrolysis gas chromatography mass spectrometry (DH/GC/MS and P/GC/MS, [3]), and pyrolysis mass spectrometry (P/MS, [4,5]). All of these methods are appropriate for the analysis and pattern recognition study of coal and petroleum products; however, methods which incorporate GC usually necessitate long analysis times and are subject to problems associated with gas chromatographic reproducibility (e.g. active sites [6], and nonconstant retention times). As a fingerprint analysis method, P/MS is rapid and ideally suited to computerized pattern recognition study of pitches due to the simple format of P/MS data (computer tabulation of normalized intensities versus masses); whereas, in the present study, the normalized peak area versus retention time date from DH/GC/MS and P/GC/MS analyses were not suitable for direct input to a computerized pattern recognition analysis program, (due to non-constant retention times and improper data format). One limitation is that P/MS does not provide positive identification of thermally evolved products (as can DH/GC/MS and P/GC/MS) due to the complexity of the spectra of a mixture of compounds produced by P/MS. Within the limits of the commercial instrumentation and computer programs used in this study, a combination of all three techniques provided the greatest capability for the differentiation of the five coal tar and petroleum based pitches studied.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 134
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 661-665 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Injector systems ; On-column injection ; Liquid chromatography, HPLC ; Dibenzothiophene oxide and dioxide ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Analytical methods are described for identification and monitoring of the oxygenated metabolites of dibenzothiophene. Since such compounds are thermolabile, GC analysis is seen to be hardly feasible with conventional injectors such as all-glass moving needle or splitless injectors. Only on-column injection gives no degradation products. In addition, reversed-phase HPLC is particularly suitable for the analysis of the sulfone or sulfoxides of dibenzothiophenes.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 135
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 680-682 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary column ; Split injector ; Herbicides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 136
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 690-693 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Selective on-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 137
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 36-37 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Cryogenic focusing ; On-column, pre-column trapping ; Volatile aroma compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 138
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 11-15 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; ECD ; Halocarbons in water, 0.1-10 ppb ; 0.5-2 μl injected on-column ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Interest in monitoring halogenated organics in drinking water and natural surface and ground water in the low ppb range continues to grow. There is a tendency to include still more volatile halocarbons, the trace determination of which is known to be rather demanding. This prompted us to re-examine the feasibility of large-volume direct aqueous injection onto capillary columns, coupled with ECD. A primary problem was to avoid simultaneous elution of water with halocarbons, since water suppresses the ground current of the ECD. The following measures contributed to the solution of this problem.Apolar, extremely inert, columns are required to elute water completely, and even before very light halocarbons. Their coatings have to be far thicker (≍ 5 mUm) than commonly employed thick films since they must permit isothermal analysis at a column temperature around 100°C in order to ensure rapid and complete elution of water. Finally, it is essential that sampling be carried out on-column for two reasons: diffusion of water vapor in the injector, resulting in delayed elution, is then eliminated, and peak distortion during splitless injection is avoided.Although we now know that persilylated columns with immobilized coatings withstand routine water injections, more longterm experience is needed to provide detailed recommendations for the handling of these columns.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 139
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 40-42 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Splitless Injection ; Drug analysis ; Concentration dependence of retention values ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 140
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 386-387 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; On column injection ; Movable injector ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 141
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 42-44 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Mg(NO3)2 .6H2O as stationary phase ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 142
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 60-63 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Cold silanization ; Medium polarity columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Silane-coupling agents, commonly used for fiberglass reinforced plastics (FRP), were applied for deactivation of silanol sites in glass capillary columns prior to coating with mediumpolarity phases such as Carbowax and Superox. The columns, prepared in a two-stage process in the case of glass (acidic leaching and drying, dynamic cold silanization followed by static coating with the phase) or a one stage process in the case of fused silica, gave the best results when deactivation and hence wettability were induced by glycidoxypropyltrimethoxy silane.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 143
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 241-246 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; Cobalt-60 gamma radiation ; Immobilized phase ; Crosslinking ; Column activity ; Temperature Stability ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fused silica capillaries deactivated with D4 and coated with OV-1 were subjected to cobalt-60 gamma radiation in order to elucidate the effect of incident radiation on column performance. The chromatographic performance of these open tubular columns in which OV-1 was polymerized in situ was found to be dependent on the dosage of radiation and was evaluated before and after the irradiated columns were rinsed with solvent. Of the radiation dosages employed, 3 MRad produced superior chromatographic performance coupled with very favorable residual surface activity.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 144
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 185-188 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Injection ; Inlets ; Volume overloading ; Concentration overloading ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 145
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 281-282 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Si-OR, bonded stationary phase ; Change of physical state ; Retention mechanism ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 146
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 255-263 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass, fused silica ; Two-dimensional technique ; Residue analysis in food ; Organophosphorus pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two-dimensional gas chromatography with two capillary columns of different polarity (SP 2100 and OV 225) is used for pesticide residue analysis in food samples. By means of “live chromatography” applying pneumatic switching technique according to Deans, unequivocal identification of 57 organophosphorus pesticides in food samples is achieved at trace concentrations. The instrument is equipped with only one injection port and one flame photometric detector. On-line data processing is very helpful, especially in calibration and checking the system's reliability with the multitude of test compounds. The complete pesticide residue analysis including clean-up of about six food samples can be completed by one person in 8 hours.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 147
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 366-370 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary column ; Chiral phase ; Amino acid enantiomers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Heliflex Chirasil-Val, a modified form of the original Chirasil-Val phase coated on fused silica capillary, has been investigated with regard to its resolution efficiency and the separation profile for various enantiomeric derivatives of amino acid. The best results could be obtained with TFA-Et derivatives by reason of the relatively low column temperature required.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 148
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 388-389 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary micro-packed columns ; Separation characteristics ; Application ; Separation of hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 149
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 273-274 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Solvent effect ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 150
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 292-299 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; GC/MS/DS ; Cryotrapping of organics ; Cryofocusing of organics ; Trace organic analysis ; Priority pollutants ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A 30 m, 0.25 mm ID, fused silica capillary column at temperatures from -60 to -100°C has been shown to be a quantitative trap for organic compounds with volatilities ranging from that of 1, 1 -dichloroethene that of chlorobenzene. This type of “whole column cryotrapping” provided sharp peaks (peak width approximately 4-7 seconds) for all compounds at a trapping temperature of -80°C and with high carrier gas pressures and linear velocities (30 psi and 110 cm/s, respectively). Whole column cryotrapping possesses great simplicity, chromatographic efficiency (no trapping loop connections), and a built-in indicator of quality assurance for trapping efficiency (i.e., peak shape). These advantages are extremely attractive and are indicative of the fact that the potential of this approach has not yet been fully appreciated.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 151
    Electronic Resource
    Electronic Resource
    Springer
    Naunyn-Schmiedeberg's archives of pharmacology 321 (1982), S. 293-297 
    ISSN: 1432-1912
    Keywords: Alcoholism ; Cerebrospinal fluid ; Ethanol ingestion ; Gas chromatography ; Mass spectrometry ; 5-Hydroxytryptophol ; Urine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The serotonin metabolite 5-hydroxytryptophol was determined in cerebrospinal fluid and urine of alcoholics and healthy subjects, by a glass capillary gas chromatographic-mass spectrometric method. The urinary excretion rate (14.6±2.9 pmoles/μmoles creatinine) and urine (109±20 pmoles/ml) and cerebrospinal fluid (4.12±0.21 pmoles/ml) concentrations in healthy subjects were established. Only 1% of the 5-hydroxytryptophol in urine occurred in free form. Ethanol ingestion (80, 120 g) by healthy subjects lead to a 20–100-fold increase in the urinary excretion rate of 5-hydroxytryptophol. In cerebrospinal fluid the increase was about 60%. Alcoholics had increased urinary excretion rates and cerebrospinal fluid levels during intoxication, which were in the same range as in intoxicated healthy subjects. During recovery from intoxication, the 5-hydroxytryptophol level in alcoholics decreased, but the CSF levels were still higher than in healthy subjects.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 152
    Electronic Resource
    Electronic Resource
    Springer
    Psychopharmacology 78 (1982), S. 170-175 
    ISSN: 1432-2072
    Keywords: Acetylcholine ; Choline ; Soman ; Organophosphate ; Anticholinesterase ; Toxicity ; Lethality ; CNS ; Brain areas ; Rats ; Gas chromatography ; Mass spectrometry ; Time course ; Cholinergic function
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The time course of changes in rat brain levels of acetylcholine (ACh) and choline (Ch) was investigated following a single SC injection of soman (0.9 LD50, 120 μg/kg) to understand the relationship between central neurotransmitter alteration and soman toxicity. Of the animals exposed to the dose of soman, 46% died within 24 h, with maximum mortality occurring during the first 40 min following soman administration. In a second group, surviving rats were killed at various times after treatment by a beam of focused microwave radiation to the head, and ACh and Ch levels were determined by gas chromatography-mass spectrometry. Soman produced a maximal ACh elevation in the brain stem at 20 min (34.4%), in cerebellum at 40 min (51.9%), in cortex and striatum at 2 h (320.3% and 35.2%, respectively), and in hippocampus and midbrain at 3 h (94.5% and 56.8%, respectively). ACh levels remained above normal approximately 30 min in the brain stem; 2 h in the midbrain, cerebellum, and striatum; 8 h in the cortex; and 16 h in the hippocampus. Ch levels were elevated in all areas except the striatum. Ch maxima occurred at 10–40 min and returned to control levels approximately 3 h after injection. Results suggest that perturbation of ACh levels due to soman was not uniform throughout the brain and that soman toxicity may reflect ACh changes in multiple areas, rather than changes in any given area. These data further suggest a possible relationship between elevated Ch levels and soman toxicity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 153
    Electronic Resource
    Electronic Resource
    Springer
    Research in experimental medicine 181 (1982), S. 19-25 
    ISSN: 1433-8580
    Keywords: Gas chromatography ; Serum level ; Azathioprine ; 6-Mercaptopurine ; Immunosuppression
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The knowledge of serum levels of azathioprine or its metabolite 6-mercaptopurine is important for the monitoring of the immunosuppressive therapy after kidney transplantation, especially when kidney function is low. For this reason, the work of Bailey et al. was modified. 6-Mercaptopurine was extracted from the serum with a mixture of isopropanol-ethylacetate (1:1 v:v), derivatized with trimethylaniliniumhydroxyde and measured gaschromatographically. Sulfhydryl-protecting reagents were added to prevent loss of substance. Oxyethyltheophylline was used as the internal standard. The extraction and clean-up method recovered 80% of the 6-mercaptopurine present, the lower limit of sensitivity was 20 ng/ml, i.e., ten times lower than that of Bailey et al. The method could be realized on eight patients treated with azathioprine, the half life of the drug was about 20–40 min within the first hour after i.v. application.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 154
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 60-62 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Amines ; Derivatization ; Chloroformate esters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The gas chromatographic analysis of amines after conversion to electron capture sensitive carbamates in two-phase systems has been studied. Hydrophilic compounds, for instance methylamine, are reacted with 2,2,2-trichloro-tert. butyl chloroformate. Quantitation below 10−7 M can be made by thermionic or electron capture detection. A hydrophobic amine, namely N,N-dimethyl-n-octylamine, was derivatized with 2,4,6-tribromophenyl chloroformate with addition of iodide ion to the aqueous phase. The favorable effect of iodide ion as well as the choice of pH and chloroformate ester is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 155
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Crystal hydrates as stationary phases ; Mobile Phases containing water ; Selective retentions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of crystallohydrates, crystallohydrate solutions and melts as stationary phases in gas chromatography has been proposed. Crystallohydrates have been shown to display high selectivity in the separation of polar organic compounds when use is made of water vapours as the mobile phase. Some aspects of gas-liquid chromatography in water vapours and with the stationary phase comprising crystallohydrates have been studied, and the preliminary results obtained point to the desirability of further progress in this field.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 156
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 245-248 
    ISSN: 1612-1112
    Keywords: Chromatoscopy ; Gas chromatography ; Graphitized carbon black ; Molecular structure and retention ; Aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A molecular-statistical calculation of the retention volumes at zero sample size on graphitized thermal carbon black is carried out for quasi-rigid molecules of fluorene, indene, 1-methylindene, 2-methylindene and three dimethylindenes. A reasonable agreement is observed between the calculated and the available experimental gas chromatographic data. The potential barrier to internal rotation and the torsional angle in styrene molecules are estimated by comparing theoretically calculated and measured retention volumes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 157
    ISSN: 1612-1112
    Keywords: Phthalides ; Gas chromatography ; Chromosorb W ; Isomerization ; Ligustilide
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary During GLC of naturally occurring mixtures of phthalides on packed columns an artefact was sometimes detected that originated from Z-ligustilide. Active sites of Chromosorb W were responsible for the formation of the artefact, that was assumed to be E-ligustilide as GC-MS revealed that its mass spectrum was identical with that of Z-ligustilide. No isomerization was observed when freshly coated Chromosorb W was used or the support was deactivated by benzoyl chloride or melamine. The identity of the artefact was confirmed by UV irradiation experiments.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 158
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 521-524 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index ; Connectivity index ; Van der Waals' volume ; Alkanes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The relationships between retention index and Van der Waals' volume and between retention index and connectivity index have been studied for 58 different alkanes (C1−C9) on squalane. The correlation coefficient for the former is higher than for the latter. From these equations a linear relationship between Van der Waals' volume and connectivity index is obtained which indicates that the two parameters are equivalent. A simple method for calculating the Van der Waals' volume of alkanes is proposed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 159
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 117-124 
    ISSN: 1612-1112
    Keywords: Various packed GC column ; Gas chromatography ; Porous layer beads ; GC/MS analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Theoretical comparisons of various packed GC column types are presented with respect to analysis time, efficiency, sample dilution, and sample capacity for a given maximum inlet pressure. In particular, totally porous particles, porous layer beads, and glass beads are compared with one another. It is shown that 30 μm porous layer beads offer a useful compromise between analysis time and plate count with relatively good sample capacity. Moreover, when using 1 mm i.d. columns (microbore), outlet flow rates that are reasonable for direct coupling to magnetic sector mass spectrometers are achieved making these columns suitable for GC/MS. Using 30 μm Zipax porous layer beads, columns yielding 8,000 to 10,000 plates/meter have been produced with inlet pressures of 13 to 26 atm. A simple modification of the injection port converts the maximum inlet pressure of a commercial gas chromatograph to 26 atm. With such pressures, columns in excess of 20,000 plates can be achieved. Chromatograms are presented illustrating the promise of these microbore columns for GC and GC/MS analysis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 160
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 351-354 
    ISSN: 1612-1112
    Keywords: Supported catalysts ; Reserved-flow GC ; Drying step ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Application of reversed-flow gas chromatography to study the drying step in the preparation of supported catalysts is proposed. It is demonstrated that this technique can be applied to investigate the kinetic law followed, as well as to obtain kinetic parameters of drying (rate constants, activation energies and frequency factors). Amaterial illustrating this application is γ-Al2O3 impregnated with usual organic solvents (n-C5H12,n-C6H14,n-C7H16, CH3COCH3 and CH3CH2OH). It was found that in all cases above a simple first-order law based onone kind of active site is followed. Moreover, it was observed that the activation energyE a of the drying process increases almost linearly with the relative molecular mass of the solvent, whereas for the same solventE a increases with the amount used. The operation of a kinetic compensation effect suggests “similar” activated complexes of the various solvents used.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 161
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 546-558 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Capillary columns ; Quantitative analysis ; Sample inlet systems ; High-speed analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The attainment of precise quatitative analytical data using open-tubular (capillary) columns in standard, commercially available gas chromatographic instrumentation is demonstrated. Key elements in the design and proper utilization of the instrumentation are discussed. The function of the various sample introduction systems is elaborated and their quantitative performance demonstrated. The extra-column contribution to band-spreading is determined and the resultant data is used assessing the suitability of commercial instrumentation for highspeed capillary gas chromatography. The quantitative analysis of a sample containing some eleven components in less than thirty seconds is shown.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 162
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 312-314 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Injection-port modification ; Oxygen and nitrogen traces
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The paper presents a new device modifying normal injection port of a gas chromatograph for eliminating air contamination thus enabling determination of traces of oxygen or nitrogen. Further modification is also proposed which enables the analysis to be carried out with a limited quantity of sample gas. Potential application of this device in the analysis of reactive gases like florine has been indicated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 163
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 765-768 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Preparative scale chromatography ; Capacity ; Dual-stage separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The capacity of different versions of single- and dual-stage separation of mixtures on a preparative scale is considered. It has been shown that dual-stage separation with intermediate condensation considerably enhances the capacity of the installation as compared with a single-stage process.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 164
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Silicone liquid phases ; Oxidation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The on-column oxidation of apolar and polar silicones used as gas chromatographic stationary phases is investigated. Even at 225° the effects of oxidation are found to be slight. Of the materials investigated the methylphenylsilicones are the most stable.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 165
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 26-31 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Ionization detectors ; Gaia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper is an account of the development of the gaia hypothesis as seen through the eyes of a gas chromatographer. Gaia is a radical notion about the Earth which postulates the climate and chemical composition to be regulated at an optimum by and for life. Gas chromatography played an important role in the gathering of evidence for the hypothesis but most significantly the art of inventing detectors lead to the developement of a planetary life detector through which gaia was revealed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 166
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 180-182 
    ISSN: 1612-1112
    Keywords: Acidic fermentation products ; Characterisation ; Gas chromatography ; Methyl esters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A rapid and simple method for the identification of acidic fermentation products is described. Methyl esters of volatile and non-volatile acids are separated on a single chromatographic column. Retention time data for a number of acids are tabulated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 167
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 183-185 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Analysis of ethylbenzene hydroperoxide ; Time normalization method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A gas chromatographic method, based on the time normalization technique, is described for the analysis of ethylbenzene hydroperoxide in mixtures containing ethylbenzene, acetophenone, 1-phenylethanol, benzaldehyde and phenol. Different liquid phases were tested and the best results were obtained with tricresyl phosphate and neopentyl glycol sebacate. The influence of the support, the liquid loading and the gas velocity are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 168
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 30-32 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Arsenic ; Inorganic materials
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the quantitative chlorination and extraction of arsenic as arsenic trichloride from a number of alloys. The conditions for the quantitative gas chromatographic measurement of the volatile chloride have been studied. The proposed method for inorganic materials is very fast giving results within 10 min; sensitive, 1.5·10−13 g As can be detected, simple and accurate. At the ng level of As the error is about 20% with a standard deviation less than 20%, and at the 10pg level the error is about 36% with a standard deviation of 44%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 169
    ISSN: 1612-1112
    Keywords: Graphizized carbon black traps ; Organic air pollutants ; Work areas ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of traps containing graphitized carbon black for the collection and pre-analysis of atmospheric pollutants in industrial areas is presented. The working conditions, in terms of trapping capability and effectiveness of release by thermal desorption are discussed. Some practical applications are also given.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 170
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Van der Waals' volume ; Polarity of stationary phase ; Retention index
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Equations for Retention Index (I) versus Van der Waals, volume (Vw) on squalane are studied for alcohols, carbonyls, esters and ethers. Each equation includes linear and branching substances with different positions of the functional group in the carbon chain. The study is extended to stationary phases with polarities from 4.29 to 91.54 on the Tarjan et al. scale. Variations of the slope and origin ordinate values with the polarity of the stationary phase are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 171
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 517-520 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Carbon-silica adsorbents ; n-Octadecanol film ; Phase transitions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The properties of the n-octadecanol film on carbon-silica adsorbent (Carbosil) were investigated. It was found that n-octadecanol forms an oriented film on the Carbosil's surface. If the surface of the basic silica gel is not completely covered with carbon, then the phase transition takes place in this film at a temperature higher than the melting temperature of n-octadecanol. One may distinguish two forms of this film, characterised by the different structures and the temperatures of the phase transitions. The first exists on the surface of silica gel unblocked by carbon. This part of the film is a monolayer, in which the alcohol molecules are vertically oriented. The solid compact-liquid expanded type phase transition at the well-defined temperature occurs in this film. In the second part of the film formed on the carbon surface, there is a multilayer of n-octadecanol. Its molecules are probably parallely oriented in relationship to the adsorbent surface. This film desintegrates progressively when the temperature increase. Maximum temperature of this phase transition is lower than the temperature of its analogue on pure silica gel surface.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 172
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 201-203 
    ISSN: 1612-1112
    Keywords: Phenols ; Whisky ; Gas chromatography ; Aroma compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Twelve volatile phenols were identified in whisky by combined gas chromatography-mass spectrometry. Of these phenols 2,4-dimethylphenol was found for the first time in the aroma of whisky. The content of phenol, o-, m-, and p-cresol, guaiacol, p-ethylphenol, p-ethylguaiacol and eugenol in whiskies originating from different countries was determined by gas chromatography as their 2,4-dinitrophenyl ethers using electron capture detection. The results show that Scotch whiskies differ from others in the content of o-, m-, and p-cresol. The odour threshold values of phenols studied were determined in a 10% (v/v) ethanol-water mixture and in some cases also in the whiskies. Cresols have been found to make contribution to the aroma of Scotch whisky.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 173
    ISSN: 1612-1112
    Keywords: Glass capillary ; Gas chromatography ; Methyl chloroacetates ; Methyl chloropropanoates ; Methyl chlorobutanoates
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The gas chromatography of all chlorinated methyl acetates, methyl propanoates and methyl mono- and dichlorobutanoates has been studied on Carbowax 20M and SE-30 glass capillary columns under various running conditions. The order of elution on a non-polar column was largely determined by the boiling point of esters, whereas on a polar column it was much influenced by the structure of compounds. Complete separation of the combined mixture of all 27 compounds could not be achieved, however, methyl 3,3-dichlorobutanoate was the only ester overlapped on both columns in spite of the various column temperatures used. The best separation of the mixture was on Carbowax 20M with a temperature program from 50°C at 8°C/min, isothermal running conditions leading either to poor separation of volatile components or long analysis time and broad peaks of higher chlorinated esters. The relative retention times for compounds at the various column temperatures are given and the retention order on a polar and on a non-polar column discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 174
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 107-111 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Thermionic ionization ; Catalytic flame ionization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A newly designed thermionic detector was operated in two modes of thermionic ionization detection (TID), and a third mode of catalytic flame ionization detection (CFID). Operating modes were varied by changing the composition of the electrically-heated thermionic/catalytic source, and the composition of gases supplied to the detector. A TID-2 source activated by a low concentration of Cs/ceramic was operated in a dilute H2/air environment and provided specific responses to nitrogen and phosphorus compounds. A TID-1 source activated by a high concentration of Cs/ceramic was operated in a N2 environment and provided very high specificities and picogram detectivities to compounds containing electronegative functional groups such as the NO2 group. A CFID source formed from Ni/ceramic was operated in a H2/air flame environment and provided universal responses to all organics with enhanced responses to some heteroatom compounds.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 175
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Fused silica capillaries ; New polar phases: OV-1701 and RSL-310 ; Immobilization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The possibilities of OV-1701 and RSL-310, two new stationary phases, have been evaluated for capillary gas chromatography in fused silica columns. OV-1701 is a cyanopropylphenyldimethyl polysiloxane of moderate polarity possessing excellent chromatographic characteristics. The phase exhibits high coating and chromatographic efficiencies, high temperature stability and is suitable for cross-linking. RSL-310 is a polar liquid stationary phase yet to be permanently bonded in a capillary column. The selectivity of both phases extends the applicability of fused silica columns.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 176
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 98-102 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Rectangular channel ; Efficiency ; Capacity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas chromatographic experiments have been performed in a truly rectangular channel with a 60∶1 cross-sectional aspect ratio, constructed according to the field-flow fractionation technology. It is shown that the peak broadening is controlled by the thickness of the channel while the maximum load is determined by the largest cross-sectional dimension. However, even with its elongated configuration, the side walls contribute significantly to the band broadening of solutes with a high diffusivity. Good agreement is found between the experimental plate height data and the recent theoretical calculations of Golay [13] taking into account the side-wall effect.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 177
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Modified thermal energy analyzer ; Selective detection of nitrogen compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A modification to the TEATM Analyzer is described, which allows it to be used as a highly selective GC detector for nitrogen compounds as well as for N-nitrosamines and nitro compounds. The modified Analyzer is as sensitive as the AFID, but has a much higher selectivity towards nitrogen compounds than the AFID. Its response appears to be molar, with an output that is dependent only on the number of nitrogen atoms present. The performance of the modified Analyzer for the analysis of ammonia, amines,N-nitrosamines, nitriles and organonitro compounds is reported and discussed, as is its application to the detection of these compounds in bacon and beer samples.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 178
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Capillary columns ; Fused silica capillaries ; Capillary drawing ; Glass capillaries
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A compact description is given of a simple and reliable method of drawing flexible fused silica capillary for gas chromatography. Some emphasis is given to the fact that the practices of drawing optical fibres should not be followed too slavishly so this leads to unnecessarily complicated and expensive equipment. Satisfactory capillary column silica tubing can be made with straightfoward extension of the method developed earlier for drawing thick walled capillary. A simple glass/silica hydrogen oxygen diffusion flame bumer is described for fusing the preform tubing at the draw point which is enclosed by a water cooled glass enclosure to trap evaporated silica and maintain the operation under dust free conditions. The uniformity of the capillary diameter is better than 5% which is adequate for most gas chromatographic purposes. The second part of the paper yet to be published will cover the methods developed for coating the capillary both internally and externally.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 179
    ISSN: 1612-1112
    Keywords: Teflon capillary columns ; Chemically modified teflon ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The preparation of teflon capillary columns employing direct coating of the stationary phase to the chemically modified teflon surface and the role of the chemically modified teflon in the separation mechanism are described. Two types of contributions from the modified teflon have been observed: nonspecific adsorption of the carbon surface and specific interactions of polar groups in the carbon skeleton. The use of polar liquid phases can eliminate adsorption due to the presence of polar groups in the modified teflon.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 180
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 704-706 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Isopropyliden-sorboses ; TMS-derivatives ; GC-MS combined technique ; Mass spectra
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method has been developed using gas chromatography — electron impact mass spectrometry for the determination of the di-0-isopropylidene-sorbofuranose and mono-0-isopropylidene-sorbofuranose. The compounds are separated as their trimethylsilyl derivatives on a capillary column coated with the stationary phase SE-52. The mass spectra show that the silylation reaction is quantitiative and that the isopropylidene groups does not change.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 181
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 125-132 
    ISSN: 1612-1112
    Keywords: Capillary columns ; Fast analysis ; Gas chromatography ; Instrumental effects ; Optimization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The efficiency of fast GC columns depends largely on the quality of the chromatograph. A theoretical and experimental study shows the relative importance of the various phenomena involved and permits the optimization of a GC System. Extremely good performances, exceeding 2,500 plates per second have been routinely obtained.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 182
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 241-244 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Monosaccharides ; Polyols ; GC of TMS derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper describes the gas chromatographic separation of the mixture of isopropylidene monosaccharides, and their trimethylsilyl derivatives. Based on the total analysis time and resolution the best stationary phase was SF-96 using Chromosorb G as the solid support and temperature programming.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 183
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 282-285 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Naphtha analysis ; Gasoline analysis ; Hydrocarbon type analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two different gas chromatographic methods are used for the determination of hydrocarbon type distribution in naphtha and gasoline samples with final boiling points up to 275 °C. The methods are based either on a single capillary column or on a valve-switched packed column system. Both methods give extensive information on paraffins, olefins, naphthenes and aromatics in total as well as by carbon-number. In each case the analysis is fully automated with a computer controlling the entire analysis from injection to results presentation. The advantages and limitations of both methods are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 184
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 322-324 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Graphitized carbon black supports ; Determination of hydroxyacids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Acid-washed graphitized carbon black (Carbopakc B) modified with trimesic adic and PEG 20M has proved to be effective for quantitative analysis of underivatized low molecular weight hydroxyacids. Calibration data revealed good linear relationships between relative peak area and concentration for lactic and 3-hydroxybutyric acids down to 0.05 mmol/l. The packing material was suitable for the analysis of aqueous solutions of hydroxyacids as it is tolerant to injections of water over a prolonged period of use. The GC system developed has been applied to the analysis of some hydroxyacids of biomedical interest in blood plasma and lactic acid contained in wine and beer.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 185
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 625-630 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular (capillary) columns ; Comparison of liquid phases ; Influence of temperature ; Retention index data
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The influence of temperature and liquid phase film thickness of open-tubular (capillary) columns on the retention index values of hydrocarbons on methylsilicone liquid phases is discussed. Data obtained on methylsilicones and squalane are compared. Retention index values of 43 hydrocarbons between 40 and 70 °C on OV-101 liquid phase are listed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 186
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 50-51 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass, fused silica ; Connection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 187
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 52-53 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Instrumentation in gas chromatography ; Capillary Injector ; Injector ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 188
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary ; SD-E enrichment ; Pesticide residues ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A simple method is described for the quantitative determination of organochlorine pesticides and polychlorinated biphenyls (PCB's) in water at the sub-ppb level. A micro gas-phase extractor advantageously replaces other preconcentration and purification techniques. The extract is analyzed by capillary gas chromatography without further enrichment. The recovery at the ppb level was nearly 100% for organochlorine pesticides and more than 80% for PCB's. The complete procedure including sample preparation, steam distillation-extraction, and capillary gas chromatographic analysis is carried out in less than four hours.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 189
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 80-84 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Triglycerides in cocoa butter, hazelnut oil ; Separation according to the number of unsaturated fatty acids (N.U.F.A.) ; Ozonolysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Structure determination of triglycerides according to their number of unsaturated fatty acids (N.U.F.A.) is more easily achieved after ozonolysis of their mixtures (fats and oils) than by capillary gas chromatographic analysis of the mixture as such. Analyses performed before and after ozonolysis of cocoa buttel, hazelnut oil, and a mixture of both fats illustrate the potential of this approach to the structure elucidation of triglycerides by chromatographic techniques.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 190
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 156-157 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Cold trapping ; Use of ABT concept in evaluating effect of trapping on peak ; shape ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 191
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 165-166 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Pulse flow reaction chromatography ; Two-detector system ; Reactions in a two-detector system ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 192
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 175-181 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Discrimination factor non-vaporizing on-column/vaporizing splitless injection for underivatized steroids ; Quantitation feasible for most underivatized steroid hormones except corticosteroids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Recent developments in the preparation of capillary columns by persilanization of the glass surfaces have resulted in highly inactive, heat-stable columns. With this type of column certain steroid hormone classes can be analyzed without derivatization; these include the 17-keto steroids, 11-oxo compounds, estrogens, and progesterone metabolites. It has been found that good quantitative analysis calls for non-vaporizing, on-column injection, as normal vaporizing injection results in breakdown of thermolabile compounds such as estriol and 17-OH progesterone metabolites. The gas chromatographic method described was used to obtain urinary steroid profiles.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 193
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 432-434 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Glass capillary columns ; Radiation induced polymerization ; Crosslinking ; Immobilized phases ; Column activity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 194
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 685-686 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Liquid chromatography ; Capillary vs. packed columns ; Performance ; Efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 195
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 48-49 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Headspace analysis ; Damping of electopneumatic dosing system ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 196
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 154-155 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; On-column injection ; Gas-flushed syringe ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 197
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Effluent splitter ; Selective detectors: NPD, Hall™ electrolytic conductivity detector ; Chloro- and chloronitroanilines ; POTW sludge extracts ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Simultaneous detection with a 700-A Hall™ and an NPD detector is an effective technique for characterizing chloro-and chloronitroanilines in highly complex Publicly Owned Water Treatment Works (POTW) sludges. The utilization of a modified Varian effluent splitter and a SE-54 fused silica capillary column permitted the detection of mid-picogram quantities of the polar chloroanilines without sacrificing peak shape. The response of the Hall™ detector in the halogen mode was roughly proportional to the number of chlorine atoms present, while the response of the Hall™ in the nitrogen mode and the NPD was less predictably influenced by the presence of one or more nitro groups. When combined with retention time data, the ratio of the NPD response to the Hall™ response has been found to substantiate the presence of chloro- and chloronitroanilines in sludge extracts.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 198
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 98-99 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Polyaromatic hydrocarbons ; Airborn Particulates ; Aircraft turbines ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 199
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 119-123 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Static coating ; Filling with mechanical closure ; Description of an easy and safe technique ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The static technique is commonly accepted as the most universal and scientific method of coating. At the same time, however, it is said to be experimentally demanding. Great efforts have therefore been made to render the method easier and safer, resulting in a wealth of recommendations confusing non-experts. Over a period of two years we have practically applied most of the reported procedures with the aim of studying their practical convenience. We do not doubt that most procedures are comparably suitable in the hands of expert users, i. e. once the initiation efforts have been forgotten, or are otherwise of little interest. We have attempted to describe a method which is specifically suited for easy and quick introduction to beginners. The method is based on mechanical column closure. The principles of the method are discussed, and a comprehensive description of its practical application is given.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 200
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 321-321 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Pyrolysis studies ; Cryofocusing device ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...